Meerut Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Meerut Development Authority Tender
Electrical and Electronics
Eprocure
Opening Date27 Feb 2024
Closing Date9 Mar 2024
Tender Amount₹ 1,54,00,000
Costs
EMD
₹ 3,08,000Document Cost
₹ 5,700Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MDAUP_906687_1Bid Award Id
ViewTender No
05_618 Dated 24 February 2024Tender Authority
Meerut Development Authority ViewPurchaser Address
-Website
http://https://mdameerut.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and Fixing 3 Watt Ingrovnd Foucs Light/burial Uplighter. (Lustre, JAQUAR, VSTP OR Equivalent) As per Direction of E/I.
110
550550
5005
Supply and Fixing 10 Watt Under Water Foucs Light. (Lustre, VSTP JAQUAR OR Equivalent) As per Direction of E/I.
21
381150
18150
Supply and Fixing 15 Watt LED Floor Light. (Lustre, VSTP JAQUAR OR Equivalent) As per Direction of E/I.
104
1016288
9772
Supply and Fixing 6 Watt well Mounted Steps/ Ramp Light. (Lustre, VSTP JAQUAR OR Equivalent) As per Direction of E/I.
18
48312
2684
Supply and Fixing 15 Watt Bollard Light. (Lustre, VSTP, JAQUAR OR Equivalent) As per Direction of E/I. (SOR/2018 SI No.-1442)
120
1029600
8580
Supply and Fixing 100 Watt Signage Light. (Lustre, VSTP, JAQUAR OR Equivalent) As per Direction of E/I.
4
14960
3740
Supply and Fixing 6 Watt tree uplight. (Lustre, VSTP, JAQUAR OR Equivalent) As per Direction of E/I.
65
145145
2233
Supply and Fixing 6 Watt Shrub upligter. (Lustre, VSTP, JAQUAR OR Equivalent) As per Direction of E/I.
50
118250
2365
Supply and Fixing 50 Watt VE and Under Seat Light (Strip light) (Lustre, VSTP, JAQUAR OR Equivalent) As per Direction of E/I.
200
105600
528
Supply and Fixing 150 Watt HT Seculpture Mashal Clump of 3 H Focus Uplighter High Illuminance. (Bajaj, Philips, Cropton, Lustre) As per Direction of E/I. (SOR/2018 SI No-1454 Cat-AA)
24
228960
9540
Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 min/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and Conly. sI no- 801/2018
-
-
-
Incoming 100 Amp TPN-1 No
-
-
-
Outgoing
32 Amp. TPN- 3 Nos
10
636000
63600
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. S.I No.-501/2018 (If Cable are Laying in HDPE Pipe Rate will be Deduct 170 per mtr.
-
-
-
10 sqmm x 4 Core (H)
4200
1373400
327
16 sqmm x 4 Core (I)
2450
840350
343
25 sqmm x 3.5 Core (J)
1150
428950
373
50 sqmm x 3.5 Core (L)
475
233700
492
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. SI NO. 504/2018
-
-
-
10 sqmm (C)
1600
32000
20
16 sqmm (D)
350
7350
21
25 sqmm (E)
150
4050
27
50 sqmm (g)
48
2304
48
S/F of 40A TPN, capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting Of time switch TSO 100 serics with contactor, HRC fuse, isolated switch metring instrument and instrument box with CTs etc. in case of TPN, complete in all respect. SI NO. 807 F (ii)/2018 As per Direction of E/I.
8
234400
29300
S/L of 63mm HDPE pipe for road crossing etc. (PSR) As per Direction of E/I.
2650
424000
160
Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing SI No-701/2018
20
81520
4076
Supply and Fixing of End Cover for 400 Amp sandwich Al bus bar trunking complete in all respect. SI No-944/2018 As per Direction of E/I.
4
24800
6200
Supply and Fixing 25 mm PVC Pipe. (DSR 2022 145 - 18 % G.S.T. Rs 32.68 = 112.32 As per Direction of E/I.
950
106704
112.32
Supply and Fixing 6 AMP to 32 AMP Sp MCB (10 KA) C Curve SI No-1002/2018 As per Direction of E/I.
475
123500
260
Supply and laying 2.5 x 2 Core Copper Wire (PSR) As per Direction of E/I.
950
52250
55
Making Maunal Trench less/ Road Cutting (PSR) As per Direction of E/I.
200
93600
468