Meerut Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Meerut Development Authority Tender
Civil And Construction
Civil Works Others
Agriculture or Forestry Works
Eprocure
Opening Date13 Nov 2024
Closing Date10 Dec 2024
Tender Amount₹ 3,97,78,000
Costs
EMD
₹ 7,96,000Document Cost
₹ 5,700Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MDAUP_973735_1Tender No
01_1757_1 Dated 09 November 2024Tender Authority
Meerut Development Authority ViewPurchaser Address
-Website
http://https://mdameerut.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(AR) - Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 of MORT& H specifications and as per direction of the enginner-in charge.DSR/
215.1
12598
2709829.8
(AR) - Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 DSR/
1300.16
3425
4453048
DSR Code 4.1.3 - Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (0.7418x7878.50)
53.86
5844
314790.67
DSR-2023/item no. 13.4.1 - 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
3900.9
265
1034050.57
DSR-2023 Code 16.91.2 - Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper bedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. (0.7418x1091.50)
2363.73
809
1913841.27
(AR) /item no. 6.1.1- Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 12.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
1058.85
5740
6077771.74
DSR-2023/item no.5.22A.6 - Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
4022.34
80
321787.2
(DSR) 2023/ No - 2.6.1 - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 0.00 Το 1.50M. Depth DSR Code 2.6.1 (0.7418x177.50)
4215.02
131
554991.68
DSR Code 2.2.1 - Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m: All kinds of soil (0.7418x395.30
4325.94
293
1268495.39
(AR) - Providing and applying primer coat with 60/70 bitumen emulsion on prepared surface of granular base including cleaning the road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means including supply of all materials, labour, T&P etc. required for proper comletion of the work as per clause 502 of MOSRT&H specifications and as per direction of the Engineer-in-charge DSR /
7170
50
358500
(AR) - Providing and applying tack coat with bitumen emulsion slow type using emulsion pressure distributor at the rate of 0.35 kg. per sqm on the prepared bitumeneous / granular surface cleaned with mechanical broom including supply of all materials, labour T&P etc. required for proper completion of the work as per clause 503 of MORT&H specification and as per dierction of the Engineer in charge.DSR/
7170
12
89625
(DSR 2023 - 2.6.1 + DSR 2.26.1) - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil )1.50Μ Το 3.00M. Depth DSR Code 2.26.1 0.7418x(177.50+126.80)
550
225
124151.5
DSR-2023/item no. 2.20.1 - Open timbering in trenches including strutting and shoring complete (measurements to be taken of the face area timbered): 1 0.00 To 1.50M Depth (0.7418x72.05))
2584.5
53
138141.53
DSR Code 2.20.2 - Open timbering in trenches including strutting and shoring complete (measurements to be taken of the face area timbered): 1.50M To 3.00M. Depth (0.7418x81.60)
2530.28
60
153157.85
DSR Code 19.6.3 - Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia.RCC. pipe. 0 to 1.5 (0.7418x899.80)
821.25
667
548159.74
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia.RCC. pipe. DSR Code 19.6.3 1.5 to 3.00
1363.75
667
910262.21
(AR) - Construction of brick masonary Slab Type manhole having internal size 0.90Mx1.20M and depth 1.50M below as per design & drawing including excavation, 22.5 cm thick cement concrete in 8:4 1 graded brick ballast 40 mm nominal size, coarse sand and cement, brick work in 1:5 cement and coarse sand,quinet in 1:2:4 cemen, coarse sand and 2cm gauge approved stone grit and 12 mm thick plinth plaster 1:3 cement & coarce sand mortor. Including supply and fixing of F.C. manhole cover F.C. foot step complete as per type of design. including supply of all materials laour T & Petc. required for proper completion of the work. Analysed
50
24354
1217712.5
(AR) - Construction of brick masonary Slab Type manhole having internal size 0.90Mx1.20M and depth 1.50M below as per design & drawing including excavation, 22.5 cm thick cement concrete in 8:4 1 graded brick ballast 40 mm nominal size, coarse sand and cement, brick work in 1:5 cement and coarse sand,quinet in 1:2:4 cemen, coarse sand and 2cm gauge approved stone grit and 12 mm thick plinth plaster 1:3 cement & coarce sand mortor. Including supply and fixing of F.C. manhole cover F.C. foot step complete as per type of design. including supply of all materials laour T & Petc. required for proper completion of the work. Analysed
98
12449
1220016.7
(AR) - Same as above Item No-X but for regulating shaft manhole size 1.00M depth. Analysed
8.77
8992
78860.37
(AR) - Same as above Item No-X but for regulating shaft Chamber size 1.00M depth. Analysed
15.97
6103
97479.12
DSR code 2.10. 1.2 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : pipes , cables etc. exceeding 80 mm dia but not exceeding 300 mm dia(0.7418x352.15)
1682.45
261
439489.59
(AR) - Providing and fixing PVC Pipe confirming to IS Make working pressure 6Kg/cm2 including testing labour T&P and all complete fittings. 110mm dia (Analysed (Rate)
2185
440
961400
DSR Code 18.31.1.2 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): Class II (0.7418x4985.85) 100 mm dia
5
3698
18492.5
DSR Code 18.34.1 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement: 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10(1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1) cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design: With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (0.7418x18896.70) 90x90x100 cm (inside)
5
14017
70087.85
DSR Code No. 5.3.3 - Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).(0.7418x11505.50)
34.16
8534
291505.41
DSR Code No. 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil
1963.16
131
258489.64
DSR Code No. 4.1.3 (0.7418x7878.50) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources
354.56
5844
2072137.07
DSR Code No. 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level : 1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived fromnatural sources)
376.54
5053
1902684.07
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%