Meerut Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Meerut Development Authority Tender

Works
Machinery and Tools
Eprocure
Opening Date15 Feb 2019
Closing Date25 Feb 2019
Tender Amount₹ 11,39,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Coupling Guard

-

-

-

... More
Common Base Frame

-

-

-

... More
Specifications

-

-

-

... More
Self Priming Mud Pump fitted with Mech Seal SucxDis: 150X150mm, Power Rating:20HP/1450RPM Flow: 180000/hr, head: 25 mtr Negative upto 2.5 Meter MOC: Wetted Parts: CI, Bearing Housing: CI Or Equivalent or as per direction of E/I.

2

290890

145445

... More
Supply and fixing of fully automatic star delta starter of ABB/L&T/Siemens Make Suitable For 10 Hp Moter With Kit-Kat & Copper Cable Lead Fitting

3

146775

48925

... More
S/F of MS Column Pipe 150mm x 6.0 mm Outlet Line 6 Mt Long With Both end Flanged. Including Jointing Material Gaskit With Nutbolt

150

427500

2850

... More
S/L of 150mm MS pipe inlet for req for site with NRV&Flexible Pipe

1

9250

9250

... More
S/F of 150 mm MS pipe Outlet 2 Mt Long With Flanged

1

8925

8925

... More
S/F of 150mm CI DF Band 90

8

30800

3850

... More
Excavation in foundation. In ordinary soil (Loan, clay or sand) including lift upto 1.50 M. and lead upto 30M. And including filling watering and ramming of excavted earth (into the trenches or into the space between the building and the sides of foundation treaches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in charges upto a distance of 30M. from the foundation trenches. (where machine can not move).

67.5

5535

82

... More
Supply and Erraction of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel base with bottom and top cable entries Electrical control panel with TPN MCCB's ( four pole 36 KA With thermal magnatic release) Switches complete and instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameter (KVA,P.F,KW etc)in each phase with touch type selector switches for different readings, instrument fuse, current transformer etc. The pannel board shall have suitable capacity electrolytic aluminium busbar as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp incoming etc.

1

92600

92600

... More
The Job including the grounting of the board as per direction of Engineer-in charge. All out going of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.

-

-

-

... More
Incoming

-

-

-

... More
100 Amp MCCB-1No

-

-

-

... More
Outgoing

-

-

-

... More
63 Amp. MCCB-2 Nos.

-

-

-

... More
Cat.B. Pannel Cubicle Type.

-

-

-

... More
S/B of safe Earthing Electrod T-19 Cu-copper coated, length 300 mm, outer pipe 48.4mmx 3.2mm, inner pipe 26.9mm X 2.6, terminal Dia 12mm, Coating 80-100 micron filled with crystalling conducting mixtur (CCM) having Anti Corrosive & conductive property with 50 Kg activated soil (BFC) capable reducing capacity along with 30 cm square C.I frame with hinged cover and manonry housing. (from electrode terminal to switch board, cost of 25 x 3 copper strip will be extra) Make: As approved in U.P.P.W.D., & C.P.R.I. Certified.

3

45240

15080

... More
S/L of 25mmx3mm G.I. Strip from earth elecrode directly in the ground as required complete in all respect.

25

2250

90

... More
S/L of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75mm. Thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be property connected with the earth conductor by clamps etc.

130

79690

613

... More
70 sqmm 3-1/2 core

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.