Madhyanchal Vidyut Vitran Nigam Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender

Works
Electrical and Electronics
Eprocure
Opening Date8 Jan 2025
Closing Soon16 Jan 2025
Tender Amount₹ 11,76,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
33 KV 3x300 sq mm XLPE O/D J/Kit

4

-

-

... More
11 KV 3x300 sq mm XLPE Cable

150

-

-

... More
11 KV 3x300 sq.mm Cable Jointing Kit I/D

2

-

-

... More
11 KV 3x300 sq.mm Cable Jointing Kit O/D

2

-

-

... More
11 KV 3x185 sq mm XLPE Cable

400

-

-

... More
11 KV 3x185 sq mm XLPE St/Th J/Kit

2

-

-

... More
11 KV 3x185 sq mm XLPE O/D J/Kit

4

-

-

... More
11 KV 3x185 sq mm XLPE I/D J/Kit

4

-

-

... More
Single core cable 1x400 sq mm

15

-

-

... More
Panther Conductor

0.1

-

-

... More
33 KV VCB 800 Amp 750 MVA

1

-

-

... More
Single T/F Control Panel

1

-

-

... More
11 KV VCB I/C CTR 600/300/5 amp, 350 MVA

1

-

-

... More
11 KV VCB O/G CTR 200/100/5 amp, 350 MVA

2

-

-

... More
Bus Coupler 350 MVA

1

-

-

... More
33 KV LINE ISOLATOR 400/800 A

1

-

-

... More
33 KV Lightening Arrestor

3

-

-

... More
33 KV BUS ISOLATOR 400/800 A

2

-

-

... More
33 KV CT 200/100/1 amp

3

-

-

... More
ST Pole 11 Mtr Long (Galvanised Bottom)

4

-

-

... More
11 KV Pin Insulator

18

-

-

... More
11 KV Pin with Nut

18

-

-

... More
MS earthing rod 20x2500 mm

4

-

-

... More
LT PVC Cable 1x240 sq mm

36

-

-

... More
Rail 105 Lbs 9 Mtr Long

1

-

-

... More
Steel Section

1665

-

-

... More
MS Round of 32 mm dia

893

-

-

... More
33 KV 3x300 XLPE Cable laying D/C in normal soil by digging of trench 1050 mm deep 750 mm wide including supply of required material as fine sand ,1st class bricks, stone slab.The inter axial spacing between two cable should be in between 0.32 M to 0.40 M. (As per JE instruction) and back filling the trench by soil (All the material required for laying will be supplied by the contractor except 33 kV XLPE cable)

90

-

-

... More
11 KV 3x300 & 11 KV 3x185 Cable laying D/C in normal soil by digging of trench 900 mm deep 750 mm wide including supply of required material as fine sand ,1st class bricks, stone slab.The inter axial spacing between two cable should be in between 0.32 M to 0.40 M. (As per JE instruction) and back filling the trench by soil (All the material required for laying will be supplied by the contractor except 33 kV XLPE cable)

215

-

-

... More
Cable laying in trench S/C.(All the material shall be provided by the contractor except cables)as per RESSPO norms.

40

-

-

... More
Hoisting of Cable on D/P with GI Pipe dia 6" dia 3 M long.The MS/GI pipe will be clamped with proper support of pole and its jumpering with clamps & nut bolts.(All the material shall be provided by the contractor except cables & O/D J/K. )as per RESSPO NORMS

4

-

-

... More
Hoisting Cable on cable stand & switchgear its jumpring complete with clamps , nuts and bolts .(All the material shall be provided by the contractor except cables & O/D J/K. )as per RESSPO NORMS

12

-

-

... More
PLINTH OF 33/11 KV T/Fs :-Construction of plinth of size 3x4 M for Power T/F having 0.4 M above ground level and 0.9 M below ground level . The work including excavation of foundation base concreting in CC 1:6:12 ratio (cement ,fine sand & brick ballast)first class brick work in cement mortar of ratio 1:4 foundation CC in 1:4:8 ratio (cement ,fine sand & brick blast) and RCC working ratio 1:2:4 (cement ,coarse sand and stone grit of 20mm gauge using MS Bars of 10mm dia( tor ) in reinforcement including its cutting ,bending & binding in required shape .The work also includes laying of 2 No 4 Mts. long each rail pieces complete with cutting & proper fitting etc. The plinth will be plastered/ finished on top and sides of the plinth.

1

-

-

... More
Erection and installation of 33/11kV, 5 or 10 MVA transformer in a levelled position on the plinth. The work includes shifting of transformer to the site of installation within the substation premises, assembling fixing and fitting of all accessories and filling of transformer oil to the desired level and ensuring that there is no leakage. Providing & fixing Copper.L-piece 07 No for transformer. All the jumpering & connection are included in the scope of work. (All materials shall be provided by the contractor)

1

-

-

... More
PLINTH FOR VCB Construction of plinth of size 2.0 mtr x 1.5 mtr x 0.9 mtr suitable for erection of upper structure for 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC 1:6:12(cement, fine sand & brick ballast ),1st class brick work in cement mortar of ratio 1:4 CC in ratio 1:4:8 and RCC work in ratio 1:2:4(cement coarse sand and stone grit of 20mm gauge )as per drawing.

1

-

-

... More
INSTALLATION OF VCB Installation of 33KV VCB complete work including commissioning.

1

-

-

... More
FABRICATION ,ERECTION & GROUTING OF ISOLATOR STRUCTURE:- Fabrication of isolator structures 3.5 Mtr. In height as per drawing No. RES 39.Digging of two Nos.pits of size 1.075x0.9x0.3 Mtr. Providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC (cement coarse sand and stone grit of 20m.m gauge)of the ratio 1:4:8 in block of 1.075 Mtrx0.3 mm including supply of all T&P complete in all respect. Both plinths of the isolator structure shall be properly finished with smoothening of edges.

3

-

-

... More
INSTALLATION OF ISOLATORS Assembling and installation of line /bus isolator on the isolator structure adjusting of opening mechanism in proper alignment so as to ensure smooth operation of the same in case of line isolator proper operation of earth links shall also be insured. The work includes fabrication for proper flxing if required.

3

-

-

... More
LIGHTENING ARRESTOR /C.T.STRUCTURE:- Fabrication of lightening arrestor/CT structure/.as per drawing No. Res-39 Digging of two Nos.pits of size 1.075x0.3x0.3Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structures in CC (Cement, coarse sand and stone grit of 20mm gauge ) of ratio 1:4:8 in block of 1.075Mtr X0.3Mtr including supply of all civil material complete in all respect. Both plinths of the structures shall be properly finished with champering of edges etc.

2

-

-

... More
INSTALLATION OF LIGHTENING ARRESTORS Assembling and installation Mounting of 3Nos (1 set) lightening arrestors on the L.A.Structure/ complete with making earth connections(separate)and line connections the work includes fabrication for proper fixing if required.

3

-

-

... More
INSTALLATION OF CT Installation of 3 Nos.(1 set) CTs on the /CTs structure . Along with C.T. J/B. The work includes fabrication for proper fixing if required.

3

-

-

... More
Shifting carefully, installation & commissioning of 33KV Single/Double circuit TF/ feeder control panel in control room including grouting of above.& painting of Feeder/TF Name

1

-

-

... More
INSTALLATION OF SWITCHGEARS IN CONTROLROOM Shifting carefully & safely 11KV Incoming/ Outgoing/Bus Coupler switchgear from outside of the switchgear room, including grouting the two No.100x50x6mm channels pieces (each 800mm long including cutting to size) and foundation bolts in 1;2:4 CC (including cutting of CC of the floor and finishing of floor) as per direction of Engineer in charge placing and fixing of switchgear on foundation providing G.I.Nuts & Bolts of proper size in proper position and alignment and checking, complete work with Mounting of P.T on incoming S/G. (All material shall be provided by the contractor)

4

-

-

... More
Fabrication and erection of cable support made of two pieces of M.S channel 100x50mm,3.0 Mtr. Long joined to each other by means of 5 Nos.M.S Flat 50x6mm pieces of size 150mm long each by welding at equal intervals as per drawing and grouting in a block of size300x300x700mm complete with one coat of ready mixed primer and two coats of aluminium paint. This includes providing of four nos M.S clamp made of M.S flat holding the cable including nuts and bolts and fixing of XLPE Cable. (All material shall be provided by the contractor except M S Channel)

3

-

-

... More
Fabrication & erection of cable exposure type double pole with the provision of separate bus bar for each cable with fixing of necessary clamps and other accessories like danger board, number plate, barbed wire, 9 No pin insulators with pins,2 No channels 100x50 mm (1600mm each),1 NoMS channel 100x50 mm(3200mm in length) and 2 NoMS angle 65x65x6 mm (each 3200mm in length ) for supporting the hoisting of cable etc. Its jumpering by single core PVC aluminium cable with proper size of lug as per RESSPO norms.(All material to be arranged by contractor except STP, MS Channel, MS Angle, Pin Insulator, Pin with nut &PVC cable).

2

-

-

... More
Grouting & plinthing of STP in depth of 1/6th the length of pole in ratio 1:4:8 in cement sand and brick ballast and construction of pole plinth 300mm x 45mm above ground level in 1:2:4 in cement, coarse sand and stone grit as per RESSPO norms.

4

-

-

... More
Painting of STP with one coat of red oxide & two coats of best quality top 2 M PO Red paint and remaining al. Paint (ISI mark) as per RESPO norms.

4

-

-

... More
EARTHING OF 11KV & 33KV SWITCHGEARS Earthing of indoor/Outdoor equipment & structures by means of M.S strip 50X6mm & connecting to pipe type earthing as per RESPO norms. Joints will be welded with high quality are welding.( All the material shall be provided by the contractor )as per RESPO norms

1

-

-

... More
Earthing by way of boring and lowering of "B" Class GI pipe 50 mm dia from ground upto the water level (minimum 40 mtr. Deep )as per standard practice with painting of earthing with green color (All material shall be provided by the contractor except the supplied items )as per resspo norms.

8

-

-

... More
Fabrication and grouting of M.S Angle 75x75x6 or 65x65x6mm in L shape & in proper size and alignment to provide support for the separate earthing strips for power transformer neutral including supply and fixing of flexible copper bonds for neutral earthing. (Only Steel provided by dept.)

1

-

-

... More
Construction of cable trench of size 300x300 mm with welded frame type control cable trench cover suitable for trench including cost of MS/Torr Bar.

15

-

-

... More
Providing and Laying of following size copper ,control cable through underground /cable trench/trenching SGR interlinking through proper connections to transformer control panel/protection board /Battery and Batter Charger /Relays 33/11 KV Transformer junction box/ 33KV VCB, CT etc. as per conditions.

-

-

-

... More
2x2.5 mm2

200

-

-

... More
4x2.5 mm2

200

-

-

... More
6x2.5 mm2

150

-

-

... More
Fixing of cable Tray for support of copper control cable

15

-

-

... More
High pressure testing of XLPE cable .Testing equipment will be arranged by the contractor

2

-

-

... More
Jumpering of all equipment's in switch yard with Panther conductor P.G.clams & proper size aluminium lugs including stringing Busbar.(all meterials shall be provided by the contractor except conductor)

1

-

-

... More
Providing & fixing of connector for CT ,isolator etc.

1

-

-

... More
Painting of 33 kv feeder Name on the Cable stand as per instruction of site engineer

1

-

-

... More
Painting of all structures & equipment's & accessories. (All materials shall be provided by the contractor ).as per RESSPO Norms.

1

-

-

... More
Welding of riser strip with boring type earthing to transformer body & transformer neutral, 33 KV VCB, LA , CT & Bus/Line Isolator etc with G.I Strip 50x6 mm .

1

-

-

... More
Earth Laying of earth mat in the switchyard by laying of M.S. Round of 32 mm dia in 500 mm deep trenches with M.S. Round 32mm dia,3 Mtr. Long earth electrodes as per drawing. The work includes welding of the M.S. Round ,connecting all steel structures in the switchyard with the earth mat by means of G.I. strips of size 50x6mm as per item below.( M.S. Round bar 32mm provided by Department )

-

-

-

... More
Excavation of earth for laying mat

100

-

-

... More
Driving of earth electrode.

14

-

-

... More
Laying of earthmat (M.S.) Bar including cutting, shaping and binding etc)

100

-

-

... More
Preparation of joints, proper making and welding; of main earthmat bar joints and applying bitumen, bitumen impregnated on joints i.e. End Joints. Cross Joints, Lap Joints.

50

-

-

... More
Welding of riser strip with earthmat and structure body.

50

-

-

... More
All earthing strip shall be painted by green color (All Material Shall be arranged by the contractor)

1

-

-

... More
Providing & Fixing of rubber mat 2x1 sq. mtr.

1

-

-

... More
GST SHALL BE PAID EXTRA

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.