Madhyanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date20 Nov 2024
Closing Soon30 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 11,200Document Cost
₹ 3,540Tender Fee
Refer Documents
Summary
12/eucc-v/lesa/2024-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MVVNL_975374_1Tender No
12/EUCC-V/LESA/2024-25Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
33 KV VCB 800 Amp. 750 MVA
1
-
-
33 KV Control Pannel single circuit Transformer
1
-
-
33 KV Lightening Arrester
3
-
-
33 KV Bus Isolator
2
-
-
33KV Current Transformer 200/100/1
3
-
-
11 KV Bus Coupler
1
-
-
11 KV Incoming VCB 600/300/5A, 350 MVA
1
-
-
11 KV Outgoing VCB 200/100/5A, 350 MVA
2
-
-
ACSR Panther Conductor for Bus Bar
50
-
-
11 KV 3x300mm2 XLPE Cable
150
-
-
11 KV 3x300mm2 Outdoor Termination Kit
2
-
-
11 KV 3x300mm2 Indoor Termination Kit
2
-
-
Copper Control Cable 2x2.5 Sq. mm.
150
-
-
Copper Control Cable 4x2.5 Sq. mm.
300
-
-
Battery charger 24 Volt
1
-
-
Battery set 24 Volt
1
-
-
MS Channel 125x65mm 3.5m long 4 Nos Pieces 14M@13.1 Kg. Mtr. With wastage
620
-
-
MS Angle 75x75x6, 2.6M 2 Nos Total 5.2@6.8 Kg./M with wastage
96
-
-
MS channel 100x50 mm
180
-
-
MS Angle 75x75x6 mm
146
-
-
MS Angle 50x50x6 mm
600
-
-
Rail 105 Lb
416
-
-
M.S Angle 65x65x6 mm
50
-
-
MS Round of 32 mm dia for laying of main earthmat in switch yard & for panel earthing bridge 550m@6.21 Kg./M
350
-
-
MS Round of 32mm dia for making MS earth electrode 32x3000mm. 78No.x3.0M@6.21 Kg./M
300
-
-
Earthing of substation Switchyard.
-
-
-
Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all the material except MS Round Bar 32 MM)
1
-
-
Cutting ,fabrication and driving of earth electrode of size 32x3000 mm
20
-
-
Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor )
250
-
-
Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms.
1
-
-
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel).
2
-
-
Painting of all structures equipment.
1
-
-
Construction of Power T/F plinth suitable for 33/11KV 05 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6 M as 12 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8 using M.S bar of 12 mm dia for reinforcement the work includes laying of 2 nos rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department)
1
-
-
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB.
1
-
-
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt)
2
-
-
Lightning Arrestor/ CT structure : - Fabrication of lightning arrestor/CT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect.
2
-
-
Erection of structures, grouting, plinthing of ALL structures equipment.
1
-
-
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
-
-
-
33 KV VCB
1
-
-
CT 200/100/1-A
3
-
-
33 KV lightning Arrestors
3
-
-
Bus/Line Isolator
2
-
-
Fabrication & Erection of Neutral Stand structure with foundation
1
-
-
Erection, commissioning and Testing of 05 MVA T/F mounting of radiator conservator tank exposure vent etc. Filling of T/F oil in radiator conservator tank with complete work as per RESPO Norms.
1
-
-
Jumpering complete T/F bay with ACSR panther Cond. and required clamp with nut & Bolts from 33KV existing bus bar to T/F( Except Panther Conductor all required material provided by Contractor.)
1
-
-
Laying of double circuit 11 KV 3x300 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench.
70
-
-
Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand, panel with proper taping with the help of empire tape. PVC tape and connectors.
4
-
-
Laying of double circuit 33 KV 3x300 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench.
40
-
-
Hoisting, jumpering, clamping of 33 KV 3x300 sq mm XLPE cable on cable stand with proper taping with the help of empire tape. PVC tape and connectors.
4
-
-
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
20
-
-
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
40
-
-
Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system as per Site Condition with cleaning of Existing Trench. (Except Control Cable all the materials provided by Contractor).
-
-
-
Copper Control Cable 2x2.5 Sq. mm.
150
-
-
Copper Control Cable 4x2.5 Sq. mm.
300
-
-
Pipe boring type earthing minimum 20 mtr deep from ground level or upto water level with B class G.I. pipe 2 " dia. Connection of equipment with earthing by GI strip 50x6 mm included in the job as per specification/norms for power transformer, VCB, CT/LA and other. (All materials will be Provided by contractor)
10
-
-
Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement erection and grouting, commissioning & testing of the same as per RESPO Norms
-
-
-
33 kV T/F Control panel
1
-
-
11 KV Incoming VCB 600/300/5A
1
-
-
11 KV Out going VCB 200/100/5A
2
-
-
11 KV VCB Bus coupler, 350 MVA
1
-
-
Supply of following auxiliary material
-
-
-
Rabber mat 2x1.5 Mtr.
2
-
-
Erection of 24 V batteries set with charger including stand (Except batteries set with charger all material and stand shall be provided by contractor) & initial charging complete set.
1
-
-
High Pressure Testing
2
-
-
Provided NOC from Electrical Safety department for Energization of 5 MVA Transformer. (The amount willl be reimbursed as per actual expenditure/receipt issued by concerned department upto maximim limit of Rs. 50000.00)
1
-
-
Note :- Return balance materials to LESA store daliganj and other work in site area
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%