Madhyanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Electrical and Electronics
Eprocure
Opening Date22 Mar 2024
Closing Date6 Apr 2024
Tender Amount₹ 49,75,000
Costs
EMD
₹ 49,750Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MVVNL_919959_1Bid Award Id
ViewTender No
91/EWC(B)/2023-24Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
33 KV 3X300mm2 XLPE Cable jointing kit O/D
34
-
-
33 KV 3X300mm2 XLPE Cable jointing kit S/through
2
-
-
ST pole 11 Mtr. Long
8
-
-
33 KV pin insulator
36
-
-
33 KV pin with nut
36
-
-
M.S. Earthing rod
4
-
-
M.S angle 65x65x6mm, 2700mm
8
-
-
Top channel 125x65x6mm 3200mm
4
-
-
T- Off Channel 125x65x1300mm
8
-
-
ACSR Dog conductor
0.07
-
-
Erection of the following support including cutting, making holes, fixing of all types of accessories digging pits complete in all respect as per RESSPO drawing. All types of clamps nuts & bolts,stone pad, washer would be provided by contractor.
-
-
-
Double pole cable exposer of ST pole
4
-
-
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
8
-
-
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
4
-
-
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete the job.
-
-
-
Double pole cable exposer of ST pole
4
-
-
Fixing of danger board and number plate on each location and G.I barbed wire including proper clamping and providing anti climbing device by using including supply of the above items.
8
-
-
Cable laying by drill method single circuit in HDPE Pipe.
120
-
-
Cable laying by drill method single circuit.
2200
-
-
Laying of single circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
400
-
-
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
34
-
-
Fixing of 33 KV O/D or S/Th Cable Jointing Kit
36
-
-
Fixing of cable route marker.
15
-
-
Part- (B) WORK SPECIFICATION FOR RECONDUCTORING OF 08 KM OVERHEAD 33 KV MAHANAGAR LINE FROM 132 KV S/S BALIPUR
-
-
-
Carriage of following line materials for 33 KV line from any Store Centre of Bareilly zone, Bareilly to site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
-
-
-
ST pole 11 Mtr. Long
10
-
-
ST pole 13 Mtr. Long
45
-
-
33 KV cross arm
55
-
-
33 KV pin insulator
165
-
-
33 KV pin with nut
165
-
-
M.S. Earthing rod
55
-
-
M.S. Angle 50x50x6mm
3000
-
-
M.S. Angle 75x75x6mm
1500
-
-
ACSR Dog conductor
24.72
-
-
11 KV disc insulator B&S type 70 KN
180
-
-
Disc fitting Dog/Racoon 70 KN
24
-
-
Complete Stay set complete
28
-
-
Gaurding angle 65x65x2950
25
-
-
G.I wire 8 Swg
700
-
-
Erection of the following support including cutting, making holes, fixing of all types of accessories digging pits complete in all respect as per RESSPO drawing. All types of clamps nuts & bolts,stone pad, washer would be provided by contractor.
-
-
-
Single support of ST Pole 11mtr long
10
-
-
Single support of ST Pole 13mtr long
45
-
-
Erection/fixing for stay set with stay wire and clamp as per RESSPO drawing including binding, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand before back filling of the pits as per RESSPO schedule all clamps, nuts & bolts, cement, brick, concrete etc would be provided by contractor.
28
-
-
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
55
-
-
Supply of suspension type clamp for Dog conductor.
90
-
-
Laying and sagging of 3 phase ACSR Dog conductor from tower of 66KV of existing Mahanagar line at Green Park colony to 132 KV S/S Balipur substation including jumpering, hoisting, fixing of all type of insulators,armor rod, ferrule, binding, jointing and its clamping etc. in all respect.
8
-
-
Safe dismentling of old & rotten ACSR Raccon conductor of existing 33 KV Mahanagar Line on 66 KV tower without damage of any insulator, clamp etc.
6
-
-
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
55
-
-
Dismantaling of old damage x-arm (10No.) and insulators (20No.) and erection of new 33 KV X-arm (10 No.) and Pin insulators(20 No.) in place of damage X-arm and insulators.
1
-
-
Repairing of existing tower base of 33 KV line with welding of newly MS angle (provided by department)
16
-
-
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete the job.
-
-
-
Single Pole of S.T Pole .
55
-
-
Fixing of danger board and number plate on each location and G.I barbed wire including proper clamping and providing anti climbing device by using including supply of the above items.
55
-
-
Loading. unloading and safe carrige of old & rotten Raccon conductor (almost 18 km.) from site to Store center, Bareilly (Distance upto Approx 2 km).
1
-
-
Part- (C) WORK SPECIFICATION FOR RECONDUCTORING OF 1.1 KM OVERHEAD 33 KV PARSAKHERA LINE FROM 220 KV S/S C.B. GANJ
-
-
-
Carriage of following line materials for 33 KV line from any Store Centre of Bareilly zone, Bareilly to site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
-
-
-
33 KV 3X300mm2 XLPE Cable
180
-
-
33 KV 3X300mm2 XLPE Cable jointing kit O/D
4
-
-
33 KV 3X300mm2 XLPE Cable jointing kit S/through
2
-
-
ST pole 11 Mtr. Long
6
-
-
ST pole 13 Mtr. Long
6
-
-
33 KV cross arm
15
-
-
33 KV pin insulator
48
-
-
33 KV pin with nut
48
-
-
M.S. Earthing rod
11
-
-
M.S angle 65x65x6mm, 2700mm
2
-
-
Top channel 125x65x6mm 3200mm
1
-
-
ACSR Dog conductor
3.4
-
-
11 KV disc insulator B&S type 70 KN
72
-
-
Disc fitting Dog/Racoon 70 KN
18
-
-
Complete Stay set complete
12
-
-
Gaurding angle 65x65x2950
20
-
-
G.I wire 8 Swg
560
-
-
Erection of the following support including cutting, making holes, fixing of all types of accessories digging pits complete in all respect as per RESSPO drawing. All types of clamps nuts & bolts,stone pad, washer would be provided by contractor.
-
-
-
Single support of ST Pole 11mtr long
4
-
-
Single support of ST Pole 13mtr long
6
-
-
Doudle pole structure on 11 Mtr. ST Pole.
1
-
-
Erection/fixing for stay set with stay wire and clamp as per RESSPO drawing including binding, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand before back filling of the pits as per RESSPO schedule all clamps, nuts & bolts, cement, brick, concrete etc would be provided by contractor.
12
-
-
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
12
-
-
Laying and sagging of 3 phase ACSR Panther conductor from Double pole upto the gentry at 132KV substation / 33KV substation including jumpering, hoisting, fixing of all type of insulators,armor rod, ferrule, binding, jointing and its clamping etc. in all respect.
1.1
-
-
Safe dismentling of old & rotten ACSR Raccon conductor of existing 33 KV DD Puram Line without damage of any insulator, cross arm, clamp etc. of existing 33 KV line.
1.1
-
-
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
11
-
-
Dismantaling of old damage x-arm (5No.) and insulators (15No.) and erection of new 33 KV X-arm (5No.) and Pin insulators(15 No.) in place of damage X-arm and insulators.
1
-
-
Fabrication and fixing of guarding angle on Single/double poles, Stringing and sagging of three nos. Earth/GI wire with cardle guarding of above 33 KV line as per RESSPO Norms including provision of all necessary clamps and hooks. Shifting of existing line conductor of 11 KV/LT line to maintain proper clearance in between both lines (all required material will be provided by the contractor except guarding angle and earth/GI wire).
20
-
-
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete the job.
-
-
-
Single Pole of S.T Pole .
10
-
-
Double pole of ST Pole
1
-
-
Fixing of danger board and number plate on each location and G.I barbed wire including proper clamping and providing anti climbing device by using including supply of the above items.
12
-
-
Laying of single circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
120
-
-
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
4
-
-
Fixing of 33 KV O/D or S/Th. Cable Jointing Kit
6
-
-
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of Incharge.
1.1
-
-
Loading. unloading and safe carrige of old & rotten Raccon conductor (almost 3.3 km.) from site to Store center, Bareilly (Distance upto Approx 2 km).
1
-
-