If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Oct 2024
Closing Date4 Nov 2024
Tender Amount₹ 1,10,95,000
Costs
EMD
₹ 1,11,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Summary
Turn Key Basis Work Against Deposit Scheme Under Edd-2, Nanpara
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MVVNL_963196_2Bid Award Id
ViewTender No
54/EDC(B)/2024-25Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
33 KV Pin Insulator with Pin
135
-
-
11 KV Disc Insulator with Fitting
6
-
-
33 KV Disc Insulator B&S Type 70 KN
156
-
-
33 KV Disc Fitting B&S Type 70 KN
39
-
-
ACSR Panther Conductor for Bus Bar
100
-
-
Stay Set Complete
36
-
-
Earthing Complete
43
-
-
Barbed Wire
100
-
-
Top Channel 125x65, 32
5
-
-
Top Channel 100x65, 32
2
-
-
X-Base Angle
7
-
-
33 KV Cable Jointing Kit O/D
6
-
-
11 KV Cable Jointing Kit I/D 3x300sqmm XLPE Cable
8
-
-
11 KV Cable Jointing Kit O/D 3x300sqmm XLPE Cable
8
-
-
11 KV Cable Jointing Kit I/D 3x185sqmm XLPE Cable
6
-
-
11 KV Cable Jointing Kit O/D 3x185sqmm XLPE Cable
6
-
-
Control Cable 6x2.5mmsq
150
-
-
Control Cable 4x2.5mmsq
300
-
-
Control Cable 2x2.5mmsq
300
-
-
Alluminium Binding Wire
18
-
-
Earth Wire Clamp
7
-
-
Alluminium Tape
2
-
-
11 KV XLPE Cable 3x300sqmm
300
-
-
11 KV XLPE Cable 3x185sqmm
440
-
-
PG Clamp for Dog/Panther Conductor
174
-
-
CT O/D 33 KV CTR 200/100/1-1A
9
-
-
CT O/D 33 KV CTR 400/200/1-1A
3
-
-
33 KV PT O/D 33 KV/110V
3
-
-
PT Structure
1
-
-
CT Structure
4
-
-
Structure for Bus Isolator
5
-
-
Structure for Line Isolator
1
-
-
Structure for Post Insulator
6
-
-
Structure for LA
4
-
-
Main Bus Bar with Structure
1
-
-
Danger Board
43
-
-
F-Bracket for 33 KV Line
36
-
-
PP & Clamp with Nut Bolts for X-Arm
36
-
-
Number Plate with clamp
43
-
-
Terminal Gantry
1
-
-
Single T/F Control Pannel
3
-
-
Feeder Control Pannel
1
-
-
33 KV Bus Isolator 800 Amp
5
-
-
33 KV Line Isolator 800 Amp
1
-
-
33 KV Post Insulator
18
-
-
Lightening Arrestor 33 KV
12
-
-
GI Pipe 6 inch Dia
18
-
-
Earth Mat of Switchyard of 33/11 KV S/S
1
-
-
Eathing of Indoor Equipment
2
-
-
Connector for L.I/B.I/L.A/VCB/CT/PT
108
-
-
Nut & Bolt
57
-
-
Painting of S/S Structure
1
-
-
Alluminium Paint
86
-
-
Red Oxid Paint
86
-
-
Cable Stand
4
-
-
Netural Stand
3
-
-
Copper L Piece M/O 50x8mm
12
-
-
T&P Kit for S/S
1
-
-
Sundrles
3
-
-
E-Braket for 33 KV Line
15
-
-
E-Braket for 11 KV Line
6
-
-
24 Volt Battery & Battery Charger with cabinet as per Market Value Industrial
1
-
-
PART-B (Erection Work)
-
-
-
Cartage, Fabrication & Erection of Single ST Pole (11 Mtr Long) for 33 KV, 11 KV & HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site with complete fitting. All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
40
-
-
Cartage, Fabrication & Erection of Double ST Pole (11 Mtr Long) for 33 KV, 11 KV & HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. All the materials for fabrication shall be arranged by the contractor as per RESPO Norms.
5
-
-
Grouting of Poles with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely. (All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
50
-
-
Supply, Grouting nozzling & binding of stay sets with stay clamp complete fittings. (All the materials for fabrication shall be arranged by the contractor as per RESPO Norms).
36
-
-
Conctreeing of Structures as per RESSPO Norms
32
-
-
Earthing Complete at HT/LT Pole as per RESSPO Norms.
43
-
-
Boring Type Earthing utpo water level Complete as per RESSPO Norms.
15
-
-
Chemical Earthing for Battery Charge as per RESSPO Norms.
1
-
-
Laying Stone in Switchyard as per Respo Norms
1
-
-
Carriage & Laying of 33 KV 3x300sqmm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks with Complete Fitting.
60
-
-
Laying of Double circuit 11 KV 3x300sqmm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks with Complete Fitting.
250
-
-
Laying of Double circuit 11 KV 3x185sqmm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks with Complete Fitting.
360
-
-
Cartage & Laying, stringing, sagging, binding & jumpering of ACSR Dog conductors of 33 KV, clamp and binding wire proper connector & Clamp (600 Mtr. For Bus Bar) (Complete Fitting.)
1200
-
-
Laying, stringing, sagging, binding & jumpering of Panther Conductors of 33 KV line of necessory clamp and binding wire proper connector & Clamp (Complete Fitting.)
0.03
-
-
GI Strip for Structure and equipment earthing Complete
140
-
-
Installation of 24 Volt Battery & Battery Charger with cabinet as per Market Value Industrial
1
-
-
Laying of Control with Complete Fitting
750
-
-
Fixing of 33 KV Cable Jointing kit O/D
6
-
-
Fixing of 11 KV Cable Jointing Kit I/D 3x300sqmm XLPE Cable
8
-
-
Fixing of 11 KV Cable Jointing Kit O/D 3x300sqmm XLPE Cable
8
-
-
Fixing of 11 KV Cable Jointing Kit I/D 3x185sqmm XLPE Cable
6
-
-
Fixing of 11 KV Cable Jointing Kit O/D 3x185sqmm XLPE Cable
6
-
-
Fixing of Single T/F Control Pannel
3
-
-
Fixing of Connector for L.I/B.I/L.A/VCB/CT/PT
108
-
-
Fitting of Feeder Control Panel
1
-
-
Erection & Fixing of Eathing of Indoor Equipment
2
-
-
Installtion of CT O/D 33 KV CTR 200/100/1-1A
9
-
-
Installtion of CT O/D 33 KV CTR 400/200/1-1A
3
-
-
Installtion of 33 KV PT O/D 33 KV/110V
3
-
-
Cartage & Installtion of 11 KV Incomeing Switch Gear 600/300/5A, 350 MVA
3
-
-
Cartage & Installtion of 11 KV Outgoing Switch Gear 200/100/5A, 250 MVA
3
-
-
High Pressure testing of XLPE cable, Testing equipment will be arranged by the contractor.
1
-
-
Insllation of Terminal Gantry as Per Assign Attached.
1
-
-
Cartage & Fixing of 11 KV Bus Coupler
1
-
-
Cartage & Fixing of 33 KV VCB 1250A
1
-
-
Cartage & Fixing of 33 KV VCB 800A
3
-
-
Fixing & Installation of PT Structure as per Resspo Norms.
1
-
-
Fixing & Installation of CT Structure as per Resspo Norms.
4
-
-
Fixing & Installation of Main Bus Bar Complete with Structure
1
-
-
Fixing & Installation of Structure for Bus Isolator
5
-
-
Fixing & Installation of Structure for Line Isolator
1
-
-
Fixing & Installation of Structure for Post Insulator
6
-
-
Fixing & Installation of Structure for LA
4
-
-
Fixing of Lightening Arrestor for 33 KV Line
12
-
-
Fixing of Interlocking Bricks in Switchyard & approach Road (1.5x60sqmm) as per norms
90
-
-
Providing & Fixing of Sign Board and other sundery items of Sub Station as per norms
3
-
-
Fixing of Cable Stand as per norms
4
-
-
Fixing of Netural Stand as per norms
3
-
-
Commissing of 5 MVA T/F and VCB
3
-
-
Plinth and Foundation of VCB as per Respo Norms.
4
-
-
Plinth for Transformer with Rail Piece as per Respo Norms.
3
-
-
Welded Mesh Fencing with Gate Complete (40x48M) per Resspo Norms.
1
-
-
Fixing of 33 KV Bus Isolator 800 Amp
5
-
-
Fixing of 33 KV Line Isolator 800 Amp
1
-
-
Fixing of 33 KV Post Insulator
18
-
-
Fixing of Number Plate with clamp
43
-
-
Alluminium Painting work (ISI Mark Paint)
86
-
-
Red Oxide Painting work (ISI Mark Paint)
86
-
-
Fixing of Earth Wire Clamp
7
-
-
Fixing of PG Clamp for Dog/Panther Conductor
174
-
-
Fixing of Alluminium Tape
2
-
-
Mounting of 33/11 KV 5 MVA T/F with complete fitting.
3
-
-
Repairing of Trench Inside Control Room
1
-
-
Painting work of Sub Station Structure
1
-
-
Construction of Trench with Cover for Control cable
30
-
-
Construction of Trench with Cover for Power/Control cable
25
-
-
Repairing of Control Room/Store Romm/JE Staff Room/Toilet/Fixing of Supply water supply (Civil/Electrical works) as per norms
1
-
-
Dismantling of 3x1.5MVA T/F
3
-
-
Dismnatling of 3 Nos 3.3 KV Incoming VCB and 03 Nos 3.3 KV Outgoing VCB Pannel with Bus Coupler
1
-
-
Dismnatling of T/F and Control Pannel to Electricity Store Centre, Brh
1
-
-
Evaluation Notes How It Works ?