Madhyanchal Vidyut Vitran Nigam Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender

Works
Electrical and Electronics
Eprocure
Opening Date10 Sep 2024
Closing Date19 Sep 2024
Tender Amount₹ 1,25,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
100 KVA

200

-

-

... More
Cutting/Opening of top cover plates & lifting of the transformers, draining of its oil & Detanking of core & coil Assembly.

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Dismantling of core & coil Assembly and cleaning of core and tank (inside) by using warm old oil and hot air making it dirt free/sludge free.

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Reconditioning of L.V leg coils strips including removing of old DPC covering then providing double paper covering and making of LV Leg coils of same size and No. of turns and dimensions as old one.

-

-

-

... More
25 KVA

6480

-

-

... More
63 KVA

2160

-

-

... More
100 KVA

2160

-

-

... More
Making of L.V leg coils from new DPC strips, of same size and No. of turns and dimensions as old one.

-

-

-

... More
25 KVA

9720

-

-

... More
63 KVA

3240

-

-

... More
100 KVA

3240

-

-

... More
Reconditioning/Making of H.V leg coils from new DPC or SE wire of same size and No. of turns and dimensions as old one.

-

-

-

... More
25 KVA

30600

-

-

... More
63 KVA

9600

-

-

... More
100 KVA

8400

-

-

... More
Assembly of core, channel (duly painted by zinc chromatic paint) & coil and fitting of other parts requiring replacements such as press board making supports between adjacent section by insulating spacers & tapping etc.

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Shifting and keeping the assembled core& coil etc. in OVEN from the repairing area

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Dragging of transformer tank to washing area and cleaning of rust/dirt etc from outer surface by using caustic soda & water solution.

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage.

-

-

-

... More
25 KVA

360

-

-

... More
63 KVA

60

-

-

... More
100 KVA

40

-

-

... More
Completely drying & Cleaning of T/F tank (inside and outside) by using hot air/cotton waste/sand paper etc completely and making it ready for painting

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint.

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Dragging/shifting out empty tank after painting to assembly area.

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Taking out core and coils assembly from the OVEN and shifting to repairing area & again tightening the assembly.

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Welding/fixing the top cover after tanking of core and coil assembly into painted tank and tightening of assembly into the tank and fitting all accessories of transformer and filling of oil.

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Spray painting of transformer tank from outside with super enamel synthetic Grey paint in two coats after providing primer of red oxide paint

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place.

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Unique number, (II) Capacity (III) Name of workshop (IV) Date of repair

-

-

-

... More
25 KVA

1800

-

-

... More
63 KVA

300

-

-

... More
100 KVA

200

-

-

... More
Part-B :- 160 KVA, 250 KVA, 400 KVA & 630 KVA

-

-

-

... More
Handling and Dragging of damaged Transformer from stacking yard to repairing hall with accessories

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Cutting/Opening of top cover plates & fittings of the transformers, draining of its oil & Detanking of core & coil Assembly.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Dismantling of core & coil Assembly and cleaning of core and tank (inside) by using warm old oil and hot air making it dirt free/sludge free.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Reconditioning of L.V leg coils strips including removing of old double paper covering and cleaning of strip than providing double paper covering

-

-

-

... More
160 KVA

3200

-

-

... More
250 KVA

11250

-

-

... More
400 KVA

9000

-

-

... More
630 KVA

3025

-

-

... More
Making of L.V leg coils from reconditioned strips/new DPC strips, of same size and No. of turns and dimensions as old one.

-

-

-

... More
160 KVA

3200

-

-

... More
250 KVA

11250

-

-

... More
400 KVA

9000

-

-

... More
630 KVA

3025

-

-

... More
Reconditioning of old damaged H.V. leg coils wire by removing old Double paper covering, cleaning of wire and providing new DPC insulation etc.

-

-

-

... More
160 KVA

5000

-

-

... More
250 KVA

17500

-

-

... More
400 KVA

13050

-

-

... More
630 KVA

5225

-

-

... More
Making of H.V leg coils from reconditioned/new DPC wire of same size No. of turns and dimensions as old one.

-

-

-

... More
160 KVA

5000

-

-

... More
250 KVA

17500

-

-

... More
400 KVA

13050

-

-

... More
630 KVA

5225

-

-

... More
Assembly of core, channel (dully painted by zinc chromatic paint) & coil and fitting of other parts requiring replacements such as press board making supports between adjacent section by insulating spacers & tapping etc.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Shifting and keeping the assembled core & coil etc. in OVEN from the repairing area

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Dragging of transformer tank to washing area and cleaning of rust/dirt etc from outer surface by using caustic soda & water solution.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Repairing of damaged T/F body/radiator by electric/gas welding complete in all respect for arresting oil leakage.

-

-

-

... More
160 KVA

20

-

-

... More
250 KVA

50

-

-

... More
400 KVA

18

-

-

... More
630 KVA

5

-

-

... More
Completely drying & Cleaning of T/F tank (inside and outside) by using hot air/cotton waste/sand paper etc completely and making it ready for painting

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Painting of inner side of T/F tank with heatproof zinc chromatic paints in two coats after providing primer of red oxide paint.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Dragging/shifting out empty tank after painting to assembly area.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Taking out core and coils assembly from the OVEN and shifting to repairing area & again tightening the assembly.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Tightening/Welding the top cover after tanking of core and coil assembly into tank and tightening of assembly into the tank and fitting all accessories of transformer and filling of oil.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Spray painting of transformer tank from outside with supper enamel synthetic Grey paint in two coats after providing primer of red oxide paint.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Dragging/shifting of repaired T/F near to the test cabin/testing place and dragging /shifting T/F to yard after testing and its stacking at identified place.

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-

... More
Punching and welding of M.S. plate of 100x50x3mm size on the outside of T/F containing following information. (I) Job number, (II) Capacity (III) Name of workshop (IV) Date of repair

-

-

-

... More
160 KVA

100

-

-

... More
250 KVA

250

-

-

... More
400 KVA

90

-

-

... More
630 KVA

25

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.