Madhyanchal Vidyut Vitran Nigam Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Dec 2024
Closing Soon26 Dec 2024
Tender Amount₹ 25,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
11 KV CAT-A ENERGYMETER

2

-

-

... More
SUPPLY OF FOLLOWING MATERIALS FOR 11 KV WORK

-

-

-

... More
SUPPLY OF 11 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT

5

-

-

... More
SUPPLY OF 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT

5

-

-

... More
SUPPLY OF HT HRC FUSE FOR PT OF APPROPRIATE RATING

10

-

-

... More
SUPPLY OF HRC FUSE OF DIFFERENT RATING

50

-

-

... More
SUPPLY OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING

10

-

-

... More
SUPPLY OF MCB OF APPROPRIATE RATING

10

-

-

... More
SUPPLY OF AUXILLARY SWITCH OF APPROPRIATE RATING

15

-

-

... More
SUPPLY OF ANTIPUMPING RELAY

5

-

-

... More
SUPPLY OF SPOUT

10

-

-

... More
SUPPLY OF BUSBAR AS PER REQUIREMENT/DRAWING

20

-

-

... More
SUPPLY OF JAW FOR 11 KV VCB TROLLEY

10

-

-

... More
SUPPLY OF INDICATOR

20

-

-

... More
SUPPLY OF AMPERE METER

10

-

-

... More
SUPPLY OF VOLT METER

5

-

-

... More
SUPPLY OF TNC SWITCH

10

-

-

... More
SUPPLY OF LOCAL /REMOTE SWITCH

5

-

-

... More
SUPPLY OF BUZZER

4

-

-

... More
SUPPLY OF CLOSING COIL (24 V D.C)

5

-

-

... More
SUPPLY OF TRIPPING COIL (24 V D.C)

5

-

-

... More
SUPPLY OF VACCUM INTERRUPTOR for Suitable for diff. make 11 KV Switch gear pannel.

5

-

-

... More
Erection of 11 KV work

-

-

-

... More
REPLACEMENT OF DEFECTIVE 11 KV CURRENT TRANSFORMERfor suitable for different Switch gear Pannels of Diff. ratio and make

16

-

-

... More
REPLACEMENT OF DEFECTIVE 11 KV POTENTIAL TRANSFORMER

3

-

-

... More
REPLACEMENT OF DEFECTIVE 11 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT

5

-

-

... More
REPLACEMENT OF DEFECTIVE 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT

5

-

-

... More
REPLACEMENT OF DEFECTIVE HT HRC FUSE FOR PT OF APPROPRIATE RATING

10

-

-

... More
REPLACEMENT OF DEFECTIVE HRC FUSE OF DIFFERENT RATING

50

-

-

... More
REPLACEMENT OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING

10

-

-

... More
REPLACEMENT OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING

10

-

-

... More
REPLACEMENT OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING

15

-

-

... More
REPLACEMENT OF DEFECTIVE ANTIPUMPING RELAY

5

-

-

... More
REPLACEMENT OF DEFECTIVE SPOUT

10

-

-

... More
REPLACEMENT OF DEFECTIVE BUSBAR AS PER REQUIREMENT/DRAWING

20

-

-

... More
REPLACEMENT DEFECTIVE JAW FOR 11 KV VCB TROLLEY

10

-

-

... More
REPLACEMENT OF DEFECTIVE INDICATOR

20

-

-

... More
REPLACEMENT OF DEFECTIVE AMPERE METER

10

-

-

... More
REPLACEMENT OF DEFECTIVE VOLT METER

5

-

-

... More
REPLACEMENT OF DEFECTIVE TNC SWITCH

10

-

-

... More
REPLACEMENT OF DEFECTIVE LOCAL /REMOTE SWITCH

5

-

-

... More
REPLACEMENT OF DEFECTIVE BUZZER

4

-

-

... More
REPLACEMENT OF DEFECTIVE CLOSING COIL (24 V D.C)

5

-

-

... More
REPLACEMENT OF DEFECTIVE TRIPPING COIL (24 V D.C)

5

-

-

... More
REPLACEMENT OF DEFECTIVE VACCUM INTERRUPTOR for Suitable for diff. make 11 KV Switch gear pannel.

5

-

-

... More
SERVICING AND REPAIRING OF MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 11 KV BREAKER of diff makes .

20

-

-

... More
SERVCING AND REPAIRING OF ELECTRICAL SYSTEM FOR PROPER METERING, OPENING, CLOSING & TRIPPING OF 11 KV BREAKER INCLUDING PROVIDING OF NECESSARY INTERNAL WIRING, LUGS, FUSES, FERRULES OF APPROPRIATE RATING AND COLOUR CODING AND OTHER NECESSARY ACCESSORIES. BATTRERY AND BATTERY CHARGER OVERHAULING & MAINTENANCE.

20

-

-

... More
The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of UNDER EUDC Bareilly Approx. distance upto 0-30 Km. Including safe loading and unloading.

-

-

-

... More
33 KV BUS ISOLATOR

1

-

-

... More
ACSR DOG CONDUCTOR

50

-

-

... More
33 KV LIGHTENING ARRESTOR

3

-

-

... More
33 KV FUSE SET

1

-

-

... More
33 KV LINE ISOLATOR

1

-

-

... More
33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1

3

-

-

... More
SUPPLY OF FOLLOWING MATERIALS FOR 33 KV WORK

-

-

-

... More
SUPPLY OF 33 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT

2

-

-

... More
SUPPLY OF 33 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT

2

-

-

... More
SUPPLY OF 33 KV PANEL AUXILARY Relay WITH RETROFITTING ARRANGEMENT

2

-

-

... More
SUPPLY OF CLOSING COIL (24 V D.C)

5

-

-

... More
SUPPLY OF TRIPPING COIL (24 V D.C)

5

-

-

... More
SUPPLY OF MAIN CONTACT BLOCK OF BREAKER

5

-

-

... More
SUPPLY OF TNC SWITCH

10

-

-

... More
SUPPLY OF CONTROL CABLE FORM PANEL TO VCB 2*2.5 SQ MM ARMOURED CABLE

100

-

-

... More
SUPPLY OF CONTROL CABLE FORM PANEL TO VCB 4*2.5 SQ MM ARMOURED CABLE

100

-

-

... More
SUPPLY OF VCB CHARGING MOTOR OF APPROPRIATE RATING

2

-

-

... More
SUPPLY OF MCB OF APPROPRIATE RATING

10

-

-

... More
SUPPLY OF AUXILLARY SWITCH OF APPROPRIATE RATING

5

-

-

... More
SUPPLY OF ANTIPUMPING RELAY

5

-

-

... More
DEFECTIVE LED INDICATOR

50

-

-

... More
SUPPLY OF AMPERE METER

4

-

-

... More
SUPPLY OF VOLT METER

2

-

-

... More
SUPPLY OF LOCAL /REMOTE SWITCH

4

-

-

... More
SUPPLY OF BUZZER

2

-

-

... More
SUPPLY OF WTI METER

5

-

-

... More
SUPPLY OF OTI METER

5

-

-

... More
SUPPLY OF MAGNETIC OIL GAUGE OF POWER TF

1

-

-

... More
SUPPLY OF BUCHOLTZ RELAY

1

-

-

... More
SUPPLY OF MAIN CONTACT BLOCK OF TRANSFORMER

4

-

-

... More
SUPPLY OF BREATHER WITH SILICA GEL

4

-

-

... More
SUPPLY OF NO,NC CONTACT SUITABLE FOR 33 KV Breaker .

5

-

-

... More
SUPPLY OF SILICA GEL

10

-

-

... More
ERECTION OF 33 KV WORK.

-

-

-

... More
ERRECTION OF 33 KV BUS ISOLATOR

1

-

-

... More
STRINGING OF ACSR DOG CONDUCTOR

50

-

-

... More
ERRECTION OF 33 KV LIGHTENING ARRESTOR

3

-

-

... More
ERRECTION OF 33 KV FUSE SET

1

-

-

... More
ERRECTION OF 33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1

3

-

-

... More
INSTALLATION OF 33 KV line isolator 33 KV

1

-

-

... More
REPLACEMENT OF DEFECTIVE 33 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT

2

-

-

... More
REPLACEMENT OF DEFECTIVE 33 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT

2

-

-

... More
REPLACEMENT OF DEFECTIVE 33 KV PANEL AUXILARY Relay WITH RETROFITTING ARRANGEMENT

2

-

-

... More
REPLACEMENT OF DEFECTIVE CLOSING COIL (24 V.D.C.)

5

-

-

... More
REPLACEMENT OF DEFECTIVE TRIPPING COIL (24 V.D.C.)

5

-

-

... More
REPLACEMENT OF DEFECTIVE MAIN CONTACT BLOCK OF BREAKER

5

-

-

... More
REPLACEMENT OF DEFECTIVE TNC SWITCH

10

-

-

... More
LAYING OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 2*2.5 SQ MM ARMOURED CABLE

100

-

-

... More
LAYING OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 4*2.5 SQ MM ARMOURED CABLE

100

-

-

... More
REPLACEMENT OF VCB CHARGING MOTOR OF APPROPRIATE RATING

2

-

-

... More
REPLACEMENT OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING

10

-

-

... More
REPLACEMENT OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING

5

-

-

... More
REPLACEMENT OF DEFECTIVE ANTIPUMPING RELAY

5

-

-

... More
REPLACEMENT OF DEFECTIVE LED INDICATOR

50

-

-

... More
REPLACMENT OF DEFECTIVE AMPERE METER

4

-

-

... More
REPLACMENT OF DEFECTIVE VOLT METER

2

-

-

... More
REPLACMENT OF DEFECTIVE LOCAL /REMOTE SWITCH

4

-

-

... More
REPLACMENT OF DEFECTIVE BUZZER

2

-

-

... More
REPLACEMENT OF DEFECTIVE WTI METR

5

-

-

... More
REPLACEMENT OF DEFECTIVE OTI METER

5

-

-

... More
REPLACEMENT OF DEFECTIVE MAGNETIC OIL GAUGE OF POWER TF

1

-

-

... More
REPLACEMENT OF DEFECTIVE BUCHOLTZ RELAY

1

-

-

... More
REPLACEMENT OF DEFECTIVE MAIN CONTACT BLOCK OF TRANSFORMER

4

-

-

... More
REPLACEMENT OF DEFECTIVE BREATHER WITH SILICA GEL

4

-

-

... More
REPLACEMENT OF SILICA GEL

10

-

-

... More
Replacement of defective NO,NC CONTACT SUITABLE FOR 33 KV Breaker .

5

-

-

... More
SERVICING AND REPAIRING OF MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV VCB

5

-

-

... More
SERVICING OF ELECTRICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS INCLUDING PROVIDING NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING & SERVICING MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS & SERVICING 33 KV PANEL FOR PROPER OPERATION OF OPENING, CLOSING, TRIPPING, ALARM, INDICATION OF BREAKER INCLUDING PROPER INTERNAL WIRING OF PANELS AND PROPER WIRING BETWEEN PANELS, DC CHARGER, 33 KV BREAKER, Control cable, 33 KV CTs, 33 KV PTs, POWER TRANSFORMER OIL TEMPRATURE INDICATOR, WINDING TEMPRATURE INDICATOR, OIL LEVEL INDICATOR, BUCHOLTZ RELAY ETC WITH PROPER CONTOL CABLE, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR. MAINTENANCE OF LIGHTING ARRANGEMENT IN SWITCHYARD & CONTROL ROOM ALSO AND OTHER IMPORTANT WORKS RELATED TO 33/11KV SUBSTAION

6

-

-

... More
REPLACEMENT OF JARJAR CONDUCTOR INCLUDING HEAVY DUTY PG CLAMP, HEAVY DUTY CONECTOR, ISOLATER JAW ETC COMPLETE

2

-

-

... More
RECTIFICATION OF LEAKAGE OF 05 MVA TRANSFORMER

2

-

-

... More
RECTIFICATION OF LEAKAGE OF 10 MVA TRANSFORMER

2

-

-

... More
Centrifuging of 10 MVA T/F

2

-

-

... More
Centrifuging of 5 MVA T/F

2

-

-

... More
Painting of All structure of switch yard such as terminal gantry, Bus gantry, Line Isolator, Bus Isolators, Fuse sets, CT Structures, Breaker Structures, LA Structures, etc. with one code of red oxide and two cote of Aluminium paint

2

-

-

... More
Note:- All the above quantity of each work is assumed as per previous experience .The Quantity of any item of work may very from 0 to maximum number within the value of tender

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.