Madhyanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Eprocure
Opening Date19 Oct 2024
Closing Date25 Oct 2024
Tender Amount₹ 16,58,000
Costs
EMD
₹ 17,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MVVNL_959982_2Bid Award Id
ViewTender No
31/SE/EWC/AYO/2024-25Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
33 KV VCB 800A, 750 MVA
1
-
-
33 KV Bus Isolator
6
-
-
33 KV Fuse set
9
-
-
33 KV P.T Outdoor
15
-
-
24 Volt Battery & Battery charger
5
-
-
33 KV Double T/F control pannel
1
-
-
C.T. O/D 33 KV CTR 200/100/1-1A
27
-
-
ACSR Dog Conductor
0.3
-
-
M.S. Channel 125x65 (for Structures)
1061.25
-
-
M.S. Angle 75x75x8 (for Structures)
509
-
-
Installation of Lightening Arrestors
Assembling and installation/ mounting of Lightening Arrestors on the L.A. structure/ complete with making earth connection ( Separate ) and line connections. The work includes fabrication for proper fixing if required.
24
-
-
Installation of Fuse set
Installation of Fuse set on the fuse set structure . The work includes fabrication for proper fixing if required.
9
-
-
Fabricatin Of Fuse set
Fabrication of fuse set Structure as per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.9 x0.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr X 0.9 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure's in proper allignment level and plumb. Plinths of all the structure shall be properly finished with champering of edges etc. (All the material will be supplied by the contractor except Steel Section)All the erection ,installation maitenance etc.will be done at requied places
9
-
-
Installation Of PT Assembling and installation/ mounting of P.T on the P.T structure/ complete with making earth connection ( Separate ) and line connections. The work includes fabrication for proper fixing if required.
15
-
-
Installation Of CT Installation of CTs of ratio 200/100/1A on the CTs structure. The work includes fabrication for proper fixing if required.
27
-
-
Installation of 33 KV VCB
Installation of 33 KV 750 MVA 800 Amp VCB on 33 KV VCB structure along with earthing by G.I. strip 50x6 mm size with main earthmat of Switchyards complete in all respect including commissioning.
1
-
-
Installation of Bus Isolators & Iine Isolators
Assembling and installation of Bus isolator and line on the Isolator structure , adjusting of opening mechanism in proper alignment and grising and oiling so as to ensured smooth operation of the same. In case of line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.
7
-
-
Plinth for 33KV VCB
Construction of plinth of size 2.0x1.5x0.9 (Mtr) suitable for erection of super structure for 33 Kv VCB including grouting of Anchor bolts in proper allingment and level. Scope of work includes excavation of foundation base concreting in CC 1:6:12 ( cement, fine sand and brick ballast) 1st class brick work in cement mortor of ratio 1:4 CC in Ratio 1:4:8 and RCC work in ratio 1:2:4 ( Cement, coarse sand and stone grit of 20 mm gauge) as per Drawing
1
-
-
Supply & Laying of 4x2.5 sq.mm. Sq. control cable from power T/F to controle board in the ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material.
900
-
-
Supply & Laying of 2x2.5 sq.mm. Sq. control cable from power T/F to controle board in the ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material.
700
-
-
Shifting carefully and installation of Single/double Transformer Control pannel in control room and opening the connection from old & existing control panel and do prope control connection into the new control panel and check & test the buccholz o/c alarm, E/F ,OYI, WTI etc. connectuion is healthy and ensure earthing of new control panel.
1
-
-
LighteningArrestor Structure
Fabrication of Lightening Arrestor per drawing No. RES 39 Digging of two Nos. Pits of size 1.075 x 0.3 x0.3 Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structure in CC ( cement, coarse sand and stone grit of 20 mm gauge) of ratio 1:4:8 in block of 1.075 Mtr X 0.3 Mtr x 0.3 Mtr including supply of all T&P complete in all respect. The work includes dragging, Shifting upto 40 Mtr. Raising and erecting the two legs with Top frame above structure's in proper allingment level and plumb. Both plinths of the structure shall be properly finished with champering of edges etc.
2
-
-
Special Earthing by way of boring and lowering of "B" class G.I. pipe 50 mm Dia 20mtr long from ground upto the water level and it will be connected to the G.I. strip 50X6 mm ( Providing & laying of G.S. strip including cutting, welding, bending etc.) for equipments(L.A,T/F,C.T., VCB.etc). The earth strip will be welded to the G.I. Pipe. The work also includes Cap & Clamps for pouring water, the cost of all material with all labour & T&P etc. Complete in all respect. (All the material will be supplied by the contractor)
32
-
-
Commissioning (testing control wiring etc) of, .33 kV VCB & 33 KV T/F control panel and its eqipments,etc. installed in switchyards and 11 KV Incoming and Outgoing Pannels complete in all respect upto energising.
15
-
-
33 KV Bay Bus Bar & Stringing.
Stringing of 33KV Bay Bus Bar by using and laying of ACSR Dog, Panther Conductor including making Vertical/Horizontal (Y-shape) jumper connection through PG clamps and connecting all the equipments ( Bus isolator, P.I. , C.T. , VCB, L.A & T/F) with each other through connecting clamps. (All the material will be supplied by the contractor)
1
-
-
Reparing and maintenance if required do replacement of electrical and machnical components of Isolator, T/F control pannel & 33 kv VCB ( i.e, Tripping coil, Tripping rod, MCB, Vaccum interrupter, Relay, replacement of damage internal wiring etc.) and do over overhaling of all mechanical parts of 33 KV VCB for proper mechanism work.
4
-
-
Battery and Battery charger (Materials will be supplied by the contractor with all accessories except Battery and Battery charger)
1
-
-
Installation of 24 Volt Battery 200 AH ( 01 set=12 Nos, 2 Volt each with ISI 1651, IS nomenclature T 200 P) With its proper connection.
1
-
-
Installation of Input voltage 230 V, AC one phase 50 hertz, output 24 Volt , 40 Amp DC Battery charger with its proper connection.
1
-
-
Stand / cabinet for battery set for proper stacking and storage
1
-
-
Providing of Rubber matting one side chequered and other side plane size1800x900x12 mm
8
-
-
providing of Hand gloves As per IS 4770 and tested potential 33 Kv.
4
-
-
Delta type Earthing of Power T/F Neutral Earthing of Power T/F Neutral by providing 03 No. of "B" class G.I. pipe 50 mm Dia 20 feet long from ground upto the water level (Delta type) and Providing and laying G.S. strip 50 x 6 mm including cutting, welding, bending etc. complete in all respect. (All the material will be supplied by the contractor)
6
-
-
Supply and fixing of P.G clamp for dog /panther and connector
52
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements