Madhyanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Eprocure
Opening Date22 Sep 2021
Closing Date28 Sep 2021
Tender Amount₹ 25,00,000
Costs
EMD
₹ 25,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MVVNL_622937_1Bid Award Id
ViewTender No
96/EDC(H)/2021-22Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
11 KV XLPE cable of size 3x185 sq.mm.
1470
-
-
... More
G.I Wire
210
-
-
... More
Line Material
7
-
-
... More
11 KV Indoor Metering cubicle
7
-
-
... More
11/0.4 KV T/F 100 KVA
2
-
-
... More
11/0.4 KV T/F 63 KVA
2
-
-
... More
11/0.4 KV T/F 25/16/10 KVA
7
-
-
... More
11 KV outdoor, pole mounted CT/PT. unit.
7
-
-
... More
ACSR Weasel Conductor
13500
-
-
... More
Cable box 3X185 Indoor & Outdoor
30
-
-
... More
Work
-
-
-
... More
Erection of PCC 8.5 mtr long with Grouting & with all accessories
30
-
-
... More
Erection of STP 11 mtr long with Grouting & with all accessories
7
-
-
... More
Erection of PCC 8.5 mtr long double pole with Grouting & with all accessories
19
-
-
... More
Erection of STP 11 mtr long double pole with Grouting & with all accessories
14
-
-
... More
Fabrication & Erection of cable stand made of two nos MS Channel 100x50x3 mtr. Long jointed to each other by means of 5nos MS Strip 50x6mm of size 150mm long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamps also. All the materials i.e. clamps nut bolts will provide by contractor.
10
-
-
... More
Grouting and Nozzling of 11 KV stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (sand, brick blast & cement). All material except stay wire shall be supplied by the contractor.
50
-
-
... More
Ordinary earthing by 11 KV MS earth Rod 2500 mm long as per RESPO schedule. All material except earthing rod shall be supplied by the contractor.
90
-
-
... More
Complete jumpering with help of GI pipe as per RESPO norms GI pipe and other required material shall be supplied by contractor.
30
-
-
... More
Laying of 11KV 3x185 sqmm XLPE cable by digging of trench size 500 mm wide 900 mm after laying of cable boxing with brick, sand and stone slab.
1470
-
-
... More
Installation of 11 KV CT/PT double metering unit of constructed double pole structure as per RESPO norms. Only 11 KV CT/PT unit shall be supplied by department.
7
-
-
... More
Fixing & commissioning of 11 KV pilfer Resistance meter (25/5Amp.) All material except pilfer Resistance metering cubical shall be supplied by the contractor.
7
-
-
... More
Earthling by way of Boring and lowering the "B" class GI pipe (Gindal ) of 50mm dia from ground upto water level not less than 20mtr as per standard practice
3
-
-
... More
Construction of T/F plinth of size 2x2x1.5 m on a padding 0.25M deep in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr hight & 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick. brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be filled from the ground level up to 15 centimetre below from the top of wall, Cement, sand & brick Ballasts should be filled up to 15 centimetre. Two no. of channel 100x50 in length 1500mm will be grouded.0.35 CM.RCC will be done with cores sand, cement and stone ballast in the ratio of 1:2:4.The T/Fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand.(All the material to be arranged by the contractor .)
2
-
-
... More
Placement of 11/0.4 KV T/Fs from dump place to newly constructed T/Fs plinth & installation, commissioning of 100 KVA T/Fs of T/F Plinth and including jumpering with the system ( All the required martial for above job shall be provided by contractor except T/Fs)
2
-
-
... More
Fabrication erection & commissioning of 100 KVA T/F on Double pole with all accessories. All material except 63 KVA T/F shall be supplied by the contractor.
2
-
-
... More
Fabrication erection & commissioning of 63 KVA T/F on Double pole with all accessories. All material except 63 KVA T/F shall be supplied by the contractor.
2
-
-
... More
Fabrication erection and commissioning of 25/16/10 KVA T/F on double/single pole with all accessories. All material except 25/16/10 KVA T/F shall be supplied by the contractor.
7
-
-
... More
Stringing of three phase 11 kv line
4.5
-
-
... More
Construction of toe wall around the 11/0.4 kv S/S, fuse unit size 0.75 Mt. At Base and 0.23 Mt. At top as per RESSPO Norms by lst class bricks in the ratio 1:6, Base concreting of the wall to be done in ratio 1:6:12 and plaster 12 mm thick in ratio 1:4.& fabrication of fencing with wire mesh 10SWG(37mmx50mm)(all material to be arranged by contractor).
24
-
-
... More
Looping & chopping of tree branches for clearance of HT/LT line after clearance of line throughout pieces of tree branches of site (Approx 3 Km).
38
-
-
... More
Instalation of cable box 11 KV Indoor & Outdoor
30
-
-