Madhyanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Civil And Construction
Eprocure
Opening Date12 Jun 2024
Closing Date5 Jul 2024
Tender Amount₹ 17,14,000
Costs
EMD
₹ 17,140Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MVVNL_920075_2Tender No
77/EWCL/2023-24Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
33 KV Lightening Arrester
3
-
-
33/11 KV 05 MVA Transformer
1
-
-
33 KV VCB 800 Amp., 750 MVA
1
-
-
33 KV CT 200/100/1 Amp.
3
-
-
33 KV Single T/F Control Pannel
1
-
-
11 KV VCB I/C CTR 600/300/5 AMP, 350 MVA
1
-
-
11 KV VCB O/G CTR 200/100/5 AMP, 350 MVA
2
-
-
Bus Coupler
1
-
-
11 KV 3x300 SQ MM XLPE
70
-
-
11 KV 3x120 SQ MM XLPE
150
-
-
MS Channel 125x65
571.8
-
-
MS Angles 50x50x6mm
596.25
-
-
MS Angles 75x75x8
231.4
-
-
MS Angles 75x75x6mm
68
-
-
Panther Conductor
150
-
-
PCC Pole 8.5mtr long
4
-
-
90 Lbs Rail
309
-
-
MS Channel 100x50 mm for Cable Stand
90
-
-
MS Channel 100x50x2028 mm (Dropper for Fuse Set)
4
-
-
MS Channel 100x50x2240mm Top Channel
2
-
-
MS Channel 100x50x2028m for TPMO
4
-
-
MS Angle 40x40x5 mm
20.76
-
-
11 KV Polymeric Disc Insulator T & C
6
-
-
11 KV Disc fitting T & C type 4500 Kg.
6
-
-
11 KV Composite Polymeric Pin Insulator
6
-
-
Earthing of pole by MS Earthing rod 20x2500 mm & 6 SWG earthing wire etc Complete
98
-
-
MS Angle 65x65x6mm 2028 mm For Cable Support
2
-
-
Complete Stay (GI Stay rod 16x1800 mm, Stay 7/10 SWG 5 Kg.)
52
-
-
11 KV 3x300 SQ MM XLPE Cable Outdoor
1
-
-
11 KV 3x300 SQ MM XLPE Cable Indoor
1
-
-
11 KV 3x120 SQ MM XLPE Cable Outdoor
2
-
-
11 KV 3x120 SQ MM XLPE Cable Indoor
2
-
-
STP Pole 11 mtr long
17
-
-
PCC Pole 8.5mtr long
77
-
-
V-type cross arm 65x65x6 mm
80
-
-
11KV Disc Insulator T&C. Type 4500 Kg.
66
-
-
Disc Fittings Dog/ Racoon 4500 Kg
66
-
-
11KV Polymeric Pin Insulator
273
-
-
MS Channel 100x50 mm for Cable Stand
120
-
-
M.S. Angle Iron 65x65x6mm, 2700 mm long for Braching
5
-
-
M.S. Angle Iron 65x65x6mm, 2400 mm long for Cable stand
2
-
-
MS Channel 100x50x2240mm Top Channel
5
-
-
GI wire 8 SWG for guarding along the line
75
-
-
GI wire 8 SWG for guarding across the line
11
-
-
Guarding Angle 65x65x6mm
119
-
-
Single Core PVC Cable 1x240/1x400 Sq. MM
20
-
-
ACSR Rabbit Conductor
15
-
-
Plinth of 5MVA 33/11KV T/F: Construction of plinth of size 3.46 x4.46 Mtr. For 5MVA T/F having 0.4 Mtr. above ground level. The work includes excavation of foundation, base concretion of CC 1:4:8 ratio (cement, fine sand & brick ballast) first class brick work in cement morter of rtio1:4 foundation CC in 1:4:8 ratio(cement, find sand & brick ballast) and RCC work in ratio 1:2:4 (cement, coarse sand and stone grit of 20mm gauge using MS bar of 10mm dia(tor) in reinforcement including its cutting, bending & binding in required shape. The work also includes laying of 2 No. 3.46 mtr. long rail pieces complete with cutting, welding & proper fitting etc. The plinth will be made as per drawing and shall be plastered/ finished on top and sides of the plinth.
1
-
-
Fabrication, Errection & Grouting of Substation Structure:
-
-
-
Isolator Structure: Fabrication of Isolator Structure 3.5 mtr in height as per Drg. digging of two no. pits of size 1.075x0.9x0.3 mtr. providing Stone Pad at the bottom of the pit and grouting of two legs of the isolator structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of 1.075x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the isolator structure shall be properly finished with smoothing of edges.
1
-
-
Lightening Arrestor, P.I. & CT Structure : Fabrication of Lightening Arrestor, P.I. & CT Structure 3.5 mtr. in height as per Drg. digging of two no pits of size 1.075x0.9x0.3 mtr. providing stone pad at the bottom of the pit and grouting of two legs of the Structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of 1.075x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the structure shall be properly finished with smoothing of edges.
3
-
-
Plinth of VCB : Construction of Plinth of size 2.0 mtrx1.5mtrx0.9mtr. suitable for erection of upper structure of 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC 1:3:6 (cement, find sand & brick ballast) 1st class brick work in cement mortor ratio 1:4:8
(cement, coarse sand and stone grit of 20mm gauge).
1
-
-
Erection and installation of 33/11KV 05 MVA T/F
-
-
-
Erection and installation of 33/11KV 05 MVA T/F in a levelled position of the plinth. The work includes shifting of T/F to the site & installation within the S/S premises, assembling, fixing and fitting of all accessories and filling of T/F oil to the desired level and ensuring that there is no leakage. All jumpering & connection are included in the scope of work.
1
-
-
Earthing for power T/F by way of boaring and lowering of 40mm dia, 2.9 mm thick GI Pipe from ground upto the water level (minimum 60 feet deep) as per standard practice as per REC Drg.
4
-
-
Fabrication and grouting (1:4:8) of MS Channel 100x50mm in L Shape & in proper size and alignment to provide support for the two separate earthing strips (50x6)mm size for power transformer neutral including supply & fixing of two no. flexible copper bonds for neutral earthing as per Drg.
1
-
-
Fabrication and erection of cable support made of two pieces of MS channel 100x50mm, 3.0 mtr. long joined to each other by means of 5 no. MS Fat 50x6mm pieces of size 150mm long each by welding at equal intervals as per drawing and grouting in block of size 300x300x700mm (1:4:8) complete with one coat of ready mixed primer and two coats of Al. Paint. This includes providing of four no. MS Clamp made of MS Flat holding the cable including nuts & bolts and fixing of XLPE cable.
1
-
-
Installation of Isolators: Assembling and installation of line/ bus isolator on the isolator structure adjusting of opening mechanis in proper alignment so as to ensure smooth operation of the same. In case of line isolator proper operation of earth links shall also be ensured. The work includes fabrication & proper connection with earthmat by G.I. erth strip 50x6mm for proper flexing if required.
1
-
-
Installation of P.I. & Lightening Arrestors : Assembling, installation & mounting of 3 No.(1set) L.A. & Post insulator on the L.A & P.I. Structure/complete with making earth connections (separate) and line connections. The work includes fabrication for fixing if required.
2
-
-
Installation of CT: Installation of 3 No.(1 set) CT on the CT Structure along with CT Junction Box. The work includes fabrication for proper fixing of C.T. If required and proper commissioning & testing.
1
-
-
Installation of VCB: Installation of 33KV VCB complete work including commissioning & testing.
1
-
-
Installation of Switchgears in Control Room:
-
-
-
Shifting carefully & installation safely 11KV I/C & O/G switchgears,Bus Coupler from outside the switchgear room placing and fixing of switchgear on foundation providing G.I. Bolt & Nuts of proper size in proper position and alignment and checking, complete work with mounting of P.T. on incoming S/G with proper testing & commissioning of switchgears.
4
-
-
Fixing and making Bus Bar connections in between all switchgears after cleaning and tapping with H.T. Tape, empire tape and PVC tape properly, providing and fixing of 6 mm thick Bakelite separators and plugging of all opening & holes with plastic compound complete work as per satisfaction of site incharge.
1
-
-
Shifting carefully and installation of 33KV Single Transformer Control Panel in Control Room including fixing, bolting & grouting of above as per requared and testing, commisioning satisfaction of site incharge.
1
-
-
Earthing of 11 KV, 33 KV Switchgears & Equipment: Earthing of 11 KV, 33 KV Switchgears equpiment by lowaring and boring of Chemical Earting outsite of switchyard and connecting through G.I. Strip 50x6mm with indoor/outdoor equipments. (All the matrial provided by the contrertor)
3
-
-
HT Cable Laying :
-
-
-
Laying & dressing of 11KV 3x300 Sq.mm U/G cable from 5MVA T/F to 11KV incoming Switchgear by excavation of earth in the trench 450mm wide, 900mm deep providing 150mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand & stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable. (All the matrical provided by the contrector Expect Cable).
50
-
-
Layng & dressing of 11KV 3x120 Sq.mm U/G cable from 5MVA T/F to 11KV incoming Switchgear by excavation of earth in the trench 450mm wide, 900mm deep providing 150mm fine sand cushion below & above the cable. The cable shall be duly protected by bricks, sand & stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable.(All the matrical provided by the contrector Expect Cable).
80
-
-
Supply & Fixing of 11KV Cable Ends:
-
-
-
Hoisting of 11KV Cable with 100 mm dia 3 Mtr. long GI Pipe on the feeder cable before mounting the cable on the double pole, lifting, mounting and clamping of 11KV feeder cable boxes on the feeder double pole structure and making connection including supply of cable mounting clamps. The work includes the sealing of GI Pipes, lower end of the pipe is to be buried into the earth by about one foot. (All the matrical provided by the contrector).
2
-
-
Hoisting of 11KV Cable for 11 KV switchgears & 33/11KV T/F.
3
-
-
Making vertical/horizontal jumper connections using Panther/Dog Conductor with existing busbar gantry through PG Clamps and connecting all equipments with each other through connecting clamps. The work includes all the jumpes from busbar to T/F (1no. T/F bay)
1
-
-
Construction of Cable trench of size 300x300mm including brick work 1:4 in wall of the trench, brick ballast work in 1:5:10 on foundation plaster 12mm thick with coarse sand 1:4 and surface finishing with cement, providing MS Strip at an interval of 0.5 Mt. and MS Angle (25x25x5mm) running on both the edges of trench.
15
-
-
Construction of welded frame type control cable trench cover 0.5 Mt. long suitable for trench including cost of MS/Tor Bar.
30
-
-
Supply and laying of following size Armoured Copper Control Cable through underground/cable trench/trenching SGR interlinking through proper connections to T/F Control panel/protection board/Battery and Battery Charger/Bunch joints, Relay 33/11KV T/F junction Box/33KV VCB, CTs etc. as per site conditions: (All the matrical provided by the contrector).
-
-
-
Cable Tray
8
-
-
4x2.5 Sq.mm
300
-
-
6x2.5 Sq.mm
300
-
-
Painting of all structures and equipments.
1
-
-
(a) Excavation of foundation pit in mix soil/normal soil, soft & hard rack and its back filling and levelling etc. The size of the pit will be 800x900 mm and having a depth of 1/6 of the full length of the support. Erection of supports by providing stone pad, fixing all clamps and other accessories such as No. Plate, Danger Board, Barbed Wire (2Kg.), Painting etc. as per relevant RESPO/ RES. drawing . This includes any fabrication, if required.
(b) Grouting of above supports with cement, concrete (CC will be of cement coarse sand & brick ballast) Grouting will be done with the help of wooden/steel formers in a block of size 450 mm x 450 mm x 1/6 of the full length of the support in the CC 1:4:8 ratio as per RESPO/ RES. drawing including back filling and proper ramming.
(c) Making of plinth of STP 300 mm, dia & 300 mm above ground level in CC of 1:4:8 & plastering of the same with 12 mm thick plaster of cement & sand in 1:4 ratio.
(d) Earthing of supports with Earth Electrode 2.5 mtr. length including excavation of pit and driving M.S. Rod upto proper depth and connecting the earth electrode with the help of 8 SWG G.I. Wire and earthing lugs. RESPO/ RES. drawing.
-
-
-
ForO/G Double Support 8.5 Mtr. PCC :
2
-
-
For Single Support Section Pole on 11 Mtr STP
5
-
-
For Single Support Section Pole on 8.5 Mtr Pcc
5
-
-
For Single Support 8.5 mtr PCC :
65
-
-
For Single Support 11 mtr STP :
15
-
-
For End Type Section Double Support 11 Mtr. STP:
1
-
-
For Section Double Support 8.5 Mtr. PCC :
5
-
-
(a) Grouting of stay rods 1800x16 mm including all works of excavation grouting by , cement concrete in size 0.60x0.60x0.3 mtr. with ratio 1:4:8 as per relevant drawing including back filling of earth and proper ramming.
(b) Fixing, tightening & nuzzling of stay with the poles and required tension as per RESPO/ RES. drawing.
52
-
-
Laying, spreading, lifting, Stinging, jointing and final sagging of ACSR Dog Conductor in accordance with profiles and sag chart including binding, jumpering and fixing of all accessories in 3 nos. conductor in parallel with PG Clamp binding wire etc requested for job.
5
-
-
Guarding between two poles like single/double/Tri./Four Poles etc. to guardLT/11 KV/Telephone lines, Road/River Crossing etc. with G.I. Wire 6 SWG and G.I. Wire 8 SWG including fixing of guarding channel of requested site with clamps and nuts and bolts as per RESPO/ RES. drawing
6
-
-
Repairing ,Overhauling ,Centrifusing of Old & Used 5 MVA Power T/F .Change of Damaged OTI & WTI of Power T/F if Required.(OTI&WTI Be Provided By the Contractor.)
1
-
-
Tree cutting compensation
2
-
-
Supply and fixing of Rubber mat 8/10mm, 2x4mtr.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements