If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Electrical Generators And Transformers
Eprocure
Opening Date6 Sep 2024
Closing Date17 Sep 2024
Tender Amount₹ 13,84,000
Costs
EMD
₹ 14,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MVVNL_921590_4Bid Award Id
ViewTender No
94/EDCB/2023-24Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
11/0.4 KV 250 KVA T/F
3
-
-
PCC Pole Support 8.5 Mtr. Long
103
-
-
11 KV MS T-Off Channel
42
-
-
Top Channel (125x65x2240 mm)
42
-
-
S/S Base Angle (75x75x6x2028mm) bolt & Nut
84
-
-
11 KV Disc Insulator Composite 45 KN (T&C Type)
126
-
-
11 KV Pin Insulator Composite
344
-
-
11 KV X-Arm V Type
4
-
-
11 KV TPMO
27
-
-
ACSR Weasal Conductor
2.69
-
-
LT XLPE Cable 3.5x70 Sqmm
426
-
-
Stay Complete
110
-
-
Earthing Complete
71
-
-
ABC Cable (3x50+1x35+1x16) sqmm
3.14
-
-
3 Phase Distribution Box
59
-
-
L.T. Cable 1x400 Sqmm
48
-
-
Construction of 250 KVA T/F plinth 1.5x1.5x2 Mtr. for mounting T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect as per RESSPO Norms.
3
-
-
Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
1
-
-
Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A Class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5m length is inserted at the bottom, Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work contractor will provide all material, manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE)
4
-
-
Dismentaling of following Transformer as per norms complete in all respect
-
-
-
11/0.4 KV 100 KVA T/F
3
-
-
11/0.4 KV 16 KVA T/F
10
-
-
11/0.4 KV 10 KVA T/F
34
-
-
Construction/Erection of Double Pole (except pole) Suitable for following T/Fs including fitting of all accessories (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms).
-
-
-
11/0.4 KV 25 KVA T/F
23
-
-
11/0.4 KV 63 KVA T/F
21
-
-
Mounting of following T/F,s as per norms complete in all respect -
-
-
-
11/0.4 KV 25 KVA T/F
23
-
-
11/0.4 KV 63 KVA T/F
21
-
-
11/0.4 KV 250 KVA T/F
3
-
-
Erection of Single PCC 8.5 Mtr. Long in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms).
59
-
-
Grouting of PCC 8.5 Mtr. Long with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/C.C. & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor).
96
-
-
Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms.
-
-
-
ACSR Weasal Conductor
2.69
-
-
L.T. LEAD LT XLPE Cable 3.5x70 Sqmm
426
-
-
ABC Cable (3x50+1x35+1x16) sqmm
3.14
-
-
L.T. Cable 1x400 Sqmm
48
-
-
Erection/Fixing of stay set with stay wire and clamp as per RESSPO norms including binding. climbing, clamping, tightening and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and C.C. and sand etc. as per RESSPO norms. All the grouting material shall be provided by the contractor.
110
-
-
The work of driving the earthing electrode and making connections with GI wire.
71
-
-
Installation, Fixing & Fabrication of 11 KV fuse set (Including Cost of Fuse set) Installed on midway of 11 KV double pole structure with mention material specification (MS Channel 100x50x2028mm), Iron Strip (50x5x305 mm) & Fuse wire of required capacity etc. shall be provided by the contractor for execution of work as per RESSPO Norms.
41
-
-
Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms. (Danger Board shall be provided by the contractor as per details given in S.No. 14 as per RESSPO Norms).
73
-
-
Erraction/Fixing of Tailess Unit (400A) (Tailess Unit shall be provided by the contractor as per RESSPO Norms). complete in all respect as per
2
-
-
Erraction/Fixing of Tailess Unit (600A) (Tailess Unit shall be provided by the contractor as per RESSPO Norms). complete in all respect as per
1
-
-
Erection & Fixing of 11 KV TPMO set with handle on existing double pole including providing of clamps and nut & Bolts and jumpering of both side by TPMO complete in all respect.
27
-
-
Errection and commissioning of 3 Phase Distribution Box on the LT Poles (All the material required shall be arranged by the contractor for errection and commissioning of distribution boxes except distribution box).
59
-
-
The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom).
-
-
-
Holding Clamps for S/s with Bolt & Nuts
191
-
-
Holding Clamps for LT T-OFF
55
-
-
Holding Clamps for Cost of MS Channel (100x50x2028mm) for fuse set
4
-
-
11 KV F Clamp with Nut & Bolt
2
-
-
PG Clamp
50
-
-
Stone Pad
73
-
-
Danger Board
73
-
-
Barbed Wire
76
-
-
3 Phase Distribution Box Clamps
44
-
-
Piercing Connector
156
-
-
LT Shackle Insulator
51
-
-
N&B for Shackle Insulator
15.6
-
-
LT Clamps with N&B for Shackle Insulator
51
-
-
Al. Lugs for 240 KV Sqmm Cable
12
-
-
LUGS OF Suitable Size (70 sqmm)
168
-
-
Stay Insulator
85
-
-
LT Tailess Unit (400A)
2
-
-
LT Tailess Unit (600A)
1
-
-
Safe back carriage of Following item (if any) from work site to Store Center, Nawada, Budaun approx distance upto 0-60 Km including loading & unloading.
-
-
-
11/0.4 KV 100 KVA T/F
3
-
-
11/0.4 KV 16 KVA T/F
10
-
-
11/0.4 KV 10 KVA T/F
34
-
-