Madhyanchal Vidyut Vitran Nigam Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender

Works
Eprocure
Opening Date17 Oct 2024
Closing DateCancelled
Tender Amount₹ 49,85,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SUPPLY & REPLACEMENT OF DEFECTIVE 11 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT

10

-

-

... More
SUPPLY & REPLACEMENT OF DEFECTIVE 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT

4

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE HT HRC FUSE FOR PT OF APPROPRIATE RATING

20

-

-

... More
SERVICING AND REPAIRING OF MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 11 KV BREAKER WARRANTY PERIOD WILL BE SIX MONTH

35

-

-

... More
REPLACEMENT AND SUPPLY OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING

20

-

-

... More
REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING

15

-

-

... More
REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING

10

-

-

... More
REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY

5

-

-

... More
REPLACEMENT AND SUPPLY OF DEFECTIVE SPOUT

28

-

-

... More
REPLACEMENT AND SUPPLY OF DEFECTIVE JAW (MALE/FEMALE) FOR 11 KV VCB TROLLEY

30

-

-

... More
REPLACEMENT & SUPPLY OF VACCUM INTERRPTOR

8

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE INDICATOR

150

-

-

... More
REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER

30

-

-

... More
REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER

9

-

-

... More
REPLACMENT & SUPPLY OF DEFECTIVE TNC SWITCH

18

-

-

... More
REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH

12

-

-

... More
REPLACMENT & SUPPLY OF DEFECTIVE BUZZER

6

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE CLOSING COIL (24 V D.C)

20

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE TNC SWITCH

10

-

-

... More
SERVCING AND REPAIRING OF ELECTRICAL SYSTEM FOR PROPER METERING, OPENING, CLOSING & TRIPPING OF 11 KV BREAKER INCLUDING PROVIDING OF NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING AND OTHER NECESSARY ACCESSORIES. BATTRERY AND BATTERY CHARGER OVERHAULING & MAINTENANCE. WARRANTY PERIOD SIX MONTH

20

-

-

... More
IN CASE OF EMERGENCY BREAKDOWN VCB REPAIRING ETC WORK LINE CLEANING AND FEFITTING AFTER REMOVAL OF FAULT WITH IN 1 HOUR AFTER GETTING INFORMATION AND WARRANTY PERIOD WILL BE SIX MONTH

18

-

-

... More
PROVIDING AND ERRECTION OF PIPE EARTHING VIA 2 INCH DIA GI PIPE (3MM) UPTO 40 FEET

8

-

-

... More
The work of safe carriage of the following material from Electricity store center Barabanki to work site under the jurisdiction of EDD-I Barabanki Approx. distance upto 30 Km. Including safe loading and unloading.

-

-

-

... More
33 KV O/D VCB 1250 A

4

-

-

... More
ACSR DOG CONDUCTOR

600

-

-

... More
ACSR WEASEL CONDUCTOR

3500

-

-

... More
LINE ISOLATOR 800A

6

-

-

... More
33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1

12

-

-

... More
11 KV POTENTIAL TRANSFORMER

5

-

-

... More
11 KV CAT-A ENERGYMETER

6

-

-

... More
ERECTION WORK

-

-

-

... More
INSTALLATION OF 33 KV O/D VCB 1250 A

1

-

-

... More
ACSR WEASEL CONDUCTOR

3500

-

-

... More
Replacement of Supply of OTI and WTI Meter.

10

-

-

... More
ACSR DOG CONDUCTOR

600

-

-

... More
INSTALLATION OF New 33 Kv CONTROL PANEL

1

-

-

... More
INSTALLATION OF 33 KV line isolator 33 KV (800 Amp.)

6

-

-

... More
REPLACEMENT OF DEFECTIVE 33 KV CURRENT TRANSFORMER 400/200/1

10

-

-

... More
REPAIRING OF DEFECTIVE 33 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT

5

-

-

... More
SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT

3

-

-

... More
SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL AUXILARY Relay WITH RETROFITTING ARRANGEMENT

2

-

-

... More
REPLACEMENT & Supply OF DEFECTIVE CLOSING COIL

9

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE TRIPPING COIL

9

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF BREAKER

1

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE TNC SWITCH

6

-

-

... More
REPLACEMENT OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 2*2.5 SQ MM ARMOURED CABLE

200

-

-

... More
REPLACEMENT OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 4*2.5 SQ MM ARMOURED CABLE

200

-

-

... More
REPLACEMENT AND SUPPLY OF VCB CHARGING MOTOR OF APPROPRIATE RATING

5

-

-

... More
REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING

10

-

-

... More
REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING

5

-

-

... More
REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY

2

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE LED INDICATOR

20

-

-

... More
REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER

2

-

-

... More
REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER

4

-

-

... More
REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH

5

-

-

... More
REPLACMENT & SUPPLY OF DEFECTIVE BUZZER

7

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE WTI of Power T/F

5

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE OTI of Power T/F

5

-

-

... More
REPAIRING & SUPPLY OF DEFECTIVE MAGNETIC OIL GAUGE OF POWER TF

2

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE BUCHOLTZ RELAY

1

-

-

... More
REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF TRANSFORMER

1

-

-

... More
SUPPLY AND ERRECTION OF SILICA GEL BREATHER COMPLETE FOR 10 MVA T/F. ALL REQUIRED MATERIAL WILL BE PROVIDED BY CONTRACTOR

2

-

-

... More
SUPPLY AND ERRECTION OF ARCHING HORN. ALL MATERIAL WILL BE PROVIDED BY CONTRACTOR.

40

-

-

... More
SUPPLY AND ERRECTION OF COPPERMESS FOR 11 KV SIDE CONNECTION NEUTRAL. ALL MATERIAL WILL BE PROVIDED BY CONTRACTOR

5

-

-

... More
REPLACEMENT AND SUPPLY OF DEFECTIVE BREATHER WITH SILICA GEL

10

-

-

... More
REPLACEMENT AND SUPPLY OF BATTERY & BATTERY CHARGER.

3

-

-

... More
SERVICING OF ELECTRICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS INCLUDING PROVIDING NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING & SERVICING MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS & SERVICING 33 KV PANEL FOR PROPER OPERATION OF OPENING, CLOSING, TRIPPING, ALARM, INDICATION OF BREAKER INCLUDING PROPER INTERNAL WIRING OF PANELS AND PROPER WIRING BETWEEN PANELS, DC CHARGER, 33 KV BREAKER, 33 KV CTs, 33 KV PTs, POWER TRANSFORMER OIL TEMPRATURE INDICATOR, WINDING TEMPRATURE INDICATOR, OIL LEVEL INDICATOR, BUCHOLTZ RELAY ETC WITH PROPER CONTOL CABLE, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR. MAINTENANCE OF LIGHTING ARRANGEMENT IN SWITCHYARD & CONTROL ROOM ALSO AND OTHER IMPORTANT WORKS RELATED TO 33/11KV SUBSTAION, WARRANTY WILL BE SIX MONTH.

10

-

-

... More
SUPPLY AND REPLACEMENT OF DAMAGED HEAVY DUTY PANTHER CONDUCTOR/ PG CLAMP IN SWITCH YARD

50

-

-

... More
SUPPLY AND REPLACEMENT OF DAMAGED ISOLATOR JAW IN COMPLETE

10

-

-

... More
RECTIFICATION OF POWER T/F LEAKAGE

10

-

-

... More
Centifusing of 10 MVA T/F

1

-

-

... More
Centifusing of 5 MVA T/F

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.