If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Sep 2024
Closing Date30 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 34,140Document Cost
₹ 3,540Tender Fee
Refer Documents
Summary
Execution of Works Supply and Repairing of necessary materials to be used in operating the distribution transformers and related other damaged equipment installed
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MVVNL_922313_7Tender No
97/EUDC-II/2023-24Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
T/F Size 250 & 400 KVA
90
-
-
T/F Size 630 KVA
28
-
-
Replacement of Old and Damaged L.T Bushing rod including Oil Seal/Gaskits etc. Removal of Old and damaged L.T Busing Rod from T/F and fixing of suitable size new L.T Bushing Rod
-
-
-
Busing rod made of Brass with all nuts and bolts etc. including replacement of all old/damaged Neoprene Oil seal/Gasket set by fixing suitable size New Neoprene Oil Seal/Gasket Set & as per site requirement, Complete Job in all respect. (Cable shall be provided by the department.)
-
-
-
T/F Size 25, 63 & 100 KVA
18
-
-
T/F Size 250 & 400 KVA
66
-
-
T/F Size 630 KVA
18
-
-
Stopping Oil leakage from T/F
-
-
-
Stopping of Major Oil leakage from T/F L.T/ H.T Side Bushing, Radiator, Conservator, Top Cover and Breather.Removing of all damaged oil Seal/Gasket Set/Cork sheet and fixing of suitable size new Neoprene Oil seal/Gasket set/Cork sheet and tightening of H.T/LT bushing rod Complete Job in all respect. ( All material will be provided by the contractor)
-
-
-
T/F Size 25, 63 & 100 KVA
22
-
-
T/F Size 250 & 400 KVA
78
-
-
T/F Size 630 KVA
20
-
-
Stopping of Minor Oil leakage from T/F fixing of suitable size new Neoprene Oil seal/Gasket set/Cork sheet and tightening
-
-
-
T/F Size 25, 63 & 100 KVA
26
-
-
T/F Size 250 & 400 KVA
95
-
-
T/F Size 6300 & 1000 KVA
19
-
-
Replacement of Old and Damaged LT PVC CABLE (All Material will be provided by department.)
-
-
-
Replacement of LT Aluminum unarmored XLPE/PVC Cable of different sizes from TF to LT fuse Unit
640
-
-
Replacement of LT Aluminum unarmored XLPE/PVC Cable of different sizes from LT fuse Unit to Pole
640
-
-
Replacement of Old and Damaged Suitable capacity of Aluminum Lugs (All Material will be provided by Contractor).
-
-
-
Supply and fixing of Aluminium Crimping Lugs(Made of 99.9% pure A grade Aluminium) suitable for 240sqmm cable, Wt 78gm. Old damaged lug removal and Proper lug crimping by crimping machine and suitable size Brass Nut and bolt to be provided by contractor.
600
-
-
Supply and fixing of Aluminium Crimping Lugs(Made of 99.9% pure A grade Aluminium) suitable for 400sqmm cable, Wt 170gm. Old damaged lug removal and Proper lug crimping by crimping machine and suitable size Brass Nut and bolt to be provided by contractor.
600
-
-
Supply and fixing of Aluminium Crimping Lugs(Made of 99.9% pure A grade Aluminium) suitable for 630sqmm cable, Wt 298gm. Old damaged lug removal and Proper lug crimping by crimping machine and suitable size Brass Nut and bolt to be provided by contractor.
300
-
-
Repairing of Old and Damaged Distribution Box. (All Material will be provided by contractor)
-
-
-
SMC L.T. Distribution Pillar box with one incomer and 3 sets of 300 Amps Kit Kat rewritable type fuse unit for outgoing circuits complete, connected on 800A bus bar.
50
-
-
Provision of fuse unit at LT side
-
-
-
Supply and Errection of complete Henely Type Tailess LT fuse unit 300 Amp consisting of 6 Nos Brass backentry, 6 Nos U type copper spring contact, Brass coupling with porcelain fitted on GI Sheet of 16 SWG with arrangement of 1 No neutral
24
-
-
Supply and Errection of complete Henely Type Tailess LT fuse unit 500 Amp consisting of 6 Nos Brass backentry, 6 Nos U type copper spring contact, Brass coupling with porcelain fitted on GI Sheet of 16 SWG with arrangement of 1 No neutral
24
-
-
Provision of fuse unit at HT side
-
-
-
To protect transformer by unbalancing and overloading, provision of fuse unit to be installed at HT side with suitable capacity of Fuse assembly ( All Material as fuse assembly, nut bolts etc. will be provided by contractor)
-
-
-
160, 250 KVA KVA T/F
54
-
-
400. 630 KVA and 1000 KVA T/F
42
-
-
Repair and Maintenance of Old and Damaged Transformer Earthing
-
-
-
Maintenance and repair of Transformer Body and Neutral Earthing by replacing damaged GI Strip 40x6mm earth and welding connection properly and earth resistance should be less then 01ohm.(All Material Provide by contactor)
77
-
-
Provision of Pipe earthing of body and neutral at two points
-
-
-
Provision of pipe earthing of transformer body and neutral seperately with 1.5 inch dia 60fit pipe. Contactor to ensure that earth connection properly should be tight and earth resistance should be less then 01ohm.(All Material Provide by contactor)
20
-
-
Maintenance & Repairing Of Damage T/F Plinth / L T Distribution box Plinth
-
-
-
Construction/Repairing & Maintenance of T/F Plinth by Using Bricks ,ballast or sand and Cement. (All Material will be provided by Contactor.
25
-
-