Madhyanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Jan 2025
Closing Date20 Jan 2025
Tender AmountRefer Documents
Costs
EMD
₹ 76,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MVVNL_993496_1Bid Award Id
ViewTender No
68/EDC-(Lucknow Rural)/24-25Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
33 KV Composite Polymer Pin Insulator with pin
48
-
-
... More
33 KV XLPE Cable 3x300 sq.mm.
5870
-
-
... More
ID/OD cable Jointing Kits 33 KV 3x300 sq.mm
20
-
-
... More
33 KV 3x300 ST Jointing Kit
20
-
-
... More
33 KV Disc Insulator with fitting
6
-
-
... More
33 KV Line Isolator
1
-
-
... More
33 KV BUS Isolator
1
-
-
... More
33 KV Lightening Arrester 400 Amp.
3
-
-
... More
33 KV CT 400/200/1-1-1 A
3
-
-
... More
33 KV VCB 800 A, 750 A
1
-
-
... More
33 KV Control Pannel single Circuit feeder
1
-
-
... More
Control Cable 4x2.5 sqmm.
180
-
-
... More
Control Cable 2x2.5 sqmm.
185
-
-
... More
RAIL/STP Pole 9 To 13 MTR
2
-
-
... More
Well/Bore type earthing of with 80 Fit Deep boring and providing GI Pipe 1.5" dia ("B" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor.
5
-
-
... More
Laying of LT XLPE/PVC Cable 3.5X70/3.5X400/1x240/1x400/1x630 sq.mm. as per RESPO Norms. Only cable shall be supplied by department.
60
-
-
... More
Digging of pit suitable for 3x300 sq.mm 33 KV XLPE cable laying. After 33 KV XLPE cable laying refilling by Bricks & sand as Per RESPO Norms. Only 33 KV XLPE cable supplied by Department.
5200
-
-
... More
Cable Hosting of 33 KV 3x300 sq. mm XLPE Cable at the following including jumpering etc complete with help of GI Pipe as Per RESPO Norms. GI pipe and other required material shall be supplied by contractor.
14
-
-
... More
Laying of 3X300 sq.mm 33 KV XLPE cable by drill method (double circuit) as per RESPO Norms. Only 11 KV XLPE cable supplied by Department.
100
-
-
... More
High pressure testing of 33 KV 3x300 XLPE cable along with arrangement of High Pressure equipment.
6
-
-
... More
Assembling and installation of line /bus isolator on the isolator structure adjusting of opening mechanism in proper alignment so as to ensure smooth operation of the same in case of line isolator proper operation of earth links shall also be insured. The work includes fabrication for proper flexing if required.
2
-
-
... More
Supply and fixing of HDPE pipe as pper RESPO Norms.
100
-
-
... More
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting of structure complete.(only M.S channel and angle provided by the deptt)
2
-
-
... More
Lightning Arrestor/ CT structure/ PT structure : - Fabrication of lightning arrestor/CT structure/ PT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect and painting of structure complete.
2
-
-
... More
Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system.
-
-
-
... More
2x2.5 sq mm
185
-
-
... More
4x2.5 sq mm
180
-
-
... More
Construction and fixing of trench cover0.5 M wide 5 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench 800 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
50
-
-
... More
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
25
-
-
... More
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel).
3
-
-
... More
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
-
-
-
... More
33 KV VCB
1
-
-
... More
CT 200/100/1-A & CT 400/200/1A
3
-
-
... More
33 KV lightning Arrestors
3
-
-
... More
Bus Isolator
1
-
-
... More
Line Isolator
1
-
-
... More
Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement, erection, grouting, commissioning & complete testing of the same as per RESPO Norms
-
-
-
... More
33kv Feeder control panel Single circuit
1
-
-
... More
Laying of D/C 33 KV, 3x300 sq mm XLPE cable in normal soil by digging of trench of suitable size & it's boxing with brick & sand and properly levelling & ramming after laying of cable etc. (All required materials will be provided by contractor except 33 KV cable)
160
-
-
... More
Making of pit for ST Jointing Kit as pper RESPO Norms.
20
-
-
... More