Lucknow Development Authority Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

Lucknow Development Authority - LDA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date24 Mar 2025
Closing Soon9 Apr 2025
Tender Amount₹ 1,27,79,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
HUSSAINABAD CHETRA STHITH MUSIUM BLOCK HETU BAHAYA VIDHUTIKARAN AND DG SET KI AAPURTI AND STHAPANA KA KARYA
HUSSAINABAD CHETRA STHITH MUSIUM BLOCK HETU BAHAYA VIDHUTIKARAN AND DG SET KI AAPURTI AND STHAPANA KA KARYA
HUSSAINABAD CHETRA STHITH MUSIUM BLOCK HETU BAHAYA VIDHUTIKARAN AND DG SET KI AAPURTI AND STHAPANA KA KARYA
HUSSAINABAD CHETRA STHITH MUSIUM BLOCK HETU BAHAYA VIDHUTIKARAN AND DG SET KI AAPURTI AND STHAPANA KA KARYA
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S.I.T.C. 400 KVA, 11KV / 433V, 50Hz, 3 phase Delta / Star connected ONAN out-door type oil filled transformer with Dyn-11 vector group suitable for floor mounting. The transformer shall have Off Load Tap Changer in steps of 2.5 % from +10 % to -10% and shall conform to IS: 1180 / IS: 2026, 1977, Level II, (latest edition). Transformer shall be complete with: : Oil conservator, Oil cooling fins/tube radiaters fitted on either side of the oil tank containing the HT & LT windings. The windings shall be with copper layered for LT side and Cu foil for HT side with class A insulation. : Transformer - IS : 1180 (Part I) : 2014 : Oil - IS : 335 : 1993 : HT side of the transformer shall be suitable for cable termination with porcelain bushing conforming to I S: 2099, complete with cable end-box & cable disconnecting chamber and the LT side suitable for Cables termination with Epoxy bushing conforming to I S: 3347 as follows: (MR)

1

1039814

1039814

... More
: H. T. Side : 1 x 3 C x 120 sq. mm. X LPE cable.

-

-

-

... More
: L. T. Side : 2 x 3.5 C x 185 sq. mm. X LPE cable.

-

-

-

... More
: Transformer shall be provided with Winding Over temperature indication and trip devices.

-

-

-

... More
: Transformer shall be provided with a Marshalling box with all the wiring for safety, measuring and indicating devices wired and terminated in it.

-

-

-

... More
H T CABLE & TERMINATION :

-

-

-

... More
Supply and laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc. (506)

100

1480

148000

... More
: 3 C x 120 sq. mm. A2XFY cable.

-

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : (DSR 2022-10.4.2

4

4674

18696

... More
: 3 C x 120 sq. mm.

-

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : (DSR 2022-10.5.2)

2

5209

10418

... More
: 3 C x 120 sq. mm. A2XFY cable.

-

-

-

... More
DIESEL GENERATING / SERVO SYSTEM :

-

-

-

... More
S.I.T.C. 415 V, 3 ph, 50 Hz Radiator cooled diesel generator (D G set) used for standby electrical energy generation. The D G Set shall be SILENT type and shall comprise of:

-

-

-

... More
 DIESEL ENGINE :

-

-

-

... More
- Vertical; multi-cylinder diesel engine of suitable b h p conforming to IS : 10002,

-

-

-

... More
: Turbo charged type, : Electronic Governer : Air cooled with water cooled radiator.

-

-

-

... More
 ALTERNATOR :

-

-

-

... More
: Directly coupled alternator conforming to IS: 4722 generating 415 V, 3 phase, 50 Hz, power,

-

-

-

... More
 Fly-wheel,

-

-

-

... More
 Common base-frame.

-

-

-

... More
 Suitable anti-vibration pads of required quantity & size,

-

-

-

... More
 Silencer shall be residential type,

-

-

-

... More
 Fuel tank (Day tank) suitable for eight hours operation - complete with fuel level indicator, filler cap, drain valve etc..

-

-

-

... More
 Electrical starting and control equipment for electrical starting of D. G. Set with:

-

-

-

... More
: Battery charger,

-

-

-

... More
: Heavy duty battery set. Battery shall be suitable for at least 3 successive cold starts.

-

-

-

... More
 Control Panel for control, monitoring & protection of D G Set.

-

-

-

... More
NOTE: As per the Government notification, D G Setshall be enclosed in a canopy meeting the specified NORMS for sound pollution.

-

-

-

... More
: 82.5 KVA SDG (MR)

1

1512500

1512500

... More
: 200 KVA SDG (MR)

1

2843500

2843500

... More
S.I.T.C. of Automatic Servo Voltage Stabilizer (AVR) of 250KVA capacity with by Pass Arrangement / Panel suitable for UNBALANCED LOAD with automatic voltage control. It shall be indoor, floor mounted and cooled with transformer oil and shall conform to the requirements of latest edition of I S: 9815-pt-1, 1994, I S: 2026-pt-1&2, 1977 and I S: 5142, 1969. AVR shall comprise of Buck–Boost transformer, 3 nos. single phase Servo Controlled Voltage Regulators and Solid state controls, enclosed in a steel container complete with rollers, cables termination arrangement and all the controls mounted in a separate sheet steel enclosure. The AVR shall have following features: (MR)

1

786500

786500

... More
: The input power shall be at 415 - 20% + 10%V, 3 Phase, 4 Wire, 50 Hz.

-

-

-

... More
: The Out-put voltage shall be 415 V, Regulation : ± 1 %.

-

-

-

... More
: Speed of voltage correction : 17 V / sec or better.

-

-

-

... More
: Over load & Short circuit protection with O/L alarm and its acceptance arrangement.

-

-

-

... More
: Protection cut-off against Over/Under Voltage.

-

-

-

... More
: Single phase protection

-

-

-

... More
: Cable terminal Boxes suitable for In-comer & Out-going cables of 2x3.5Cx185 sq mm A2XFY cables or as required.

-

-

-

... More
METERING & CONTROLS:

-

-

-

... More
: Digital ammeter with selector switch : 2 Nos (I/P-1No + O/P – 1No)

-

-

-

... More
: Digital Voltmeter with selector switch : 2 Nos(I/P-1No + O/P – 1No)

-

-

-

... More
: Frequency meter : 1No

-

-

-

... More
: 3 nos. phase indication lamps.

-

-

-

... More
: Auto / manual selector switch.

-

-

-

... More
: 3 nos phase voltage correction (increase/decrease) swiches in manual mode.

-

-

-

... More
: Out put voltage setting switch in Auto mode

-

-

-

... More
: AVR bypass arrangement

-

-

-

... More
: Servo-stabilizer shall be complete with first fill of Oil.

-

-

-

... More
- 250 KVA Servo stabilizer by pass arrangement

-

-

-

... More
- Servo-stabilizer shall be Oil Cooled with first fill of 1000 ltr. Oil. Make: Powertron / Servel / Piyush (PACT)

-

-

-

... More
L. T. PANELS

-

-

-

... More
D. G. AMF WITH LOAD MANAGEMENT PANEL

-

-

-

... More
S.I.T.C Automatic mains failure panel with load management arrangement (PLC-AMF-LM) for 82.5 x 200 KVA DG sets as per SLD. : The Panel shall be free standing, floor mounted, indoor, compartmentalized cubicle, bolted construction, dust & vermin proof, made of Sheet steel (2 mm for doors & 1.6 mm other faces), surface treated with 7 tank process and painted with anticorrosion paint / powder coated in an approved shade. The enclosure shall be IP 52 protected as per BIS. Electrolytic grade Aluminum bus bars shall be insulated with colored heat shrinkable PVC sleeves & supported on SMC / DMC molded supports with anti-tracking barriers. Each section of the AMF-LM panel shall comprise of the metering, annunciation, protection and control functions as required.(MR)

1

2268750

2268750

... More
: The controls of the AMF panel and the load management sequence as per the SLD, shall be PLC based. The mains failure shall be sensed on incoming side of mains ACB and initiate the starting cycle of D.G. set after an adjustable 0-6 sec delay. The switch over of power between the Mains power and the D G power shall take place with suitably sized (EDO) ACBs in the PLC Panel. After the D.G. set has taken the load, on restoration of mains power, the load shall be connected back to the Mains, however, D.G. set shall continue to run for an adjustable time of 0-10 minutes before switching off.

-

-

-

... More
: The PLC shall be compatible to each other and together, control all the D G sets as per the actual load as required.

-

-

-

... More
All MCCBs shall have: : Ics = Icu = 100% for the breakers. : MCCB's upto 200A shall be with thermal - magnetic releases and beyond 200A shall be with micro-processor based releases. : MCCB's shall be with extended rotary handle.

-

-

-

... More
 INCOMER:

-

-

-

... More
MCCBs shall be as per SLD as follows with required controls: : 415 V, 500 A, 4Pole, 50 Hz, MCCB : 2 Nos. (i/c+b/c) : 415 V, 500 A, 4Pole, Contactor : 2 Nos. (i/c+b/c) : 415 V, 320 A, 4Pole, 50 Hz, MCCB : 1 Nos. (DG i/c) : 415 V, 320 A, 4Pole, Contactor : 1 Nos. (DG i/c) : 415 V, 160 A, 4Pole, 50 Hz, MCCB : 1 Nos. (DG i/c) : 415 V, 160 A, 4Pole, Contactor : 1 Nos. (DG i/c)

-

-

-

... More
BUS BARS: : 500A TP + N Aluminium suitable for 1.1 K V with a fault level with-stand: 16 K A for 1 second in two parts as per SLD. The Earth Bus shall be of CU & run contnuously throughout the width of the panel.

-

-

-

... More
 OUTGOINGS :

-

-

-

... More
: 415 V, 250 A, 4Pole, 50 Hz, MCCB : 2 Nos.

-

-

-

... More
: 415 V, 200 A, 4Pole, 50 Hz, MCCB : 6 Nos.

-

-

-

... More
: 415 V, 63 A, 4Pole, 50 Hz, MCCB : 3 Nos.

-

-

-

... More
: 415 V, 200 A, 3Pole, 50 Hz, MCCB : 1 Nos.

-

-

-

... More
: Protection of the feeders as required.

-

-

-

... More
: All controls, Annunciations and indications for safe and trouble-free operation of the D G Set. : The operational sequence shall be PLC controlled as per the scheme in the SLD.

-

-

-

... More
: 100 KVAR TP Capacitor Bank, Delta connected in (=2*25+4*10+2*5) KVAR units with 7% de-tuned reactor, 440V, 50Hz complete with digital APFC Relay and automatic switching arrangement, suitably sized protection MCCBs/MCBs, Contactors, Auto / Manual selector switches and indicators for selecting the operating mode - all factory wired. Capacitor bank shall be suitable for heavy duty, 480V, 50 Hz, 3 Ph, 4 Wire system.

-

-

-

... More
: Class B surge arrester with nominal discharge current(In as per IEC 61643-1) 30KA (for 8/20ms) & Impulse current 7KA(for 10/350ms) between phase to neutral. & 50KA (8/20ms) impulse current for neutral to earth. Maximum continuous operating voltage shall be 320V. Response time (ta) shall be less than 25ns for phase to neutral. Voltage protection level shall be less than 900V at 5KA (8/20ms) for phase to neutral & 1.2KV for neutral to earth. (OBO Bettermann make or equivalent). : 1 No.

-

-

-

... More
MDBS & DBS

-

-

-

... More
S.I.T.C. Main Distribution Board (MDB) indoor, floor / wall-mounted type, conforming to I S : 13032 (Latest Edition) with key-lockable door; complete with the bus-bars components and accessories mounted and wire connections terminated in the board as per SLD & as follows:

-

-

-

... More
All MCCBs shall have: : Ics = Icu = 100% for the breakers. : MCCB's upto 200A shall be with thermal - magnetic releases and beyond 200A shall be with micro-processor based releases. : MCCB's shall be with extended rotary handle.

-

-

-

... More
MDB L+P+LIFT (MR)

1

163350

163350

... More
 INCOMER:

-

-

-

... More
: 160A (10KA), 4P, 415 V, 50 Hz. MCCB : 1 No. MCCB shall be with digital Voltmeter & Ammeter & LED phase indications as per SLD.

-

-

-

... More
 BUS BARS :

-

-

-

... More
: 160A TP + N Aluminium suitable for 1.1 K V with a fault level with-stand: 10 K A for 1 second. The Earth Bus shall be of CU & run contnuously throughout the width of the panel.

-

-

-

... More
 METERING:

-

-

-

... More
 OUTGOINGS :

-

-

-

... More
: 415 V, 50 Hz, 63 A (10KA), 4Pole MCB : 14 Nos.

-

-

-

... More
: Class B+C surge arrester Panel Make: Vidyut Control (I) Pvt Ltd / Ambit Switchgear / Tricolite

-

-

-

... More
MDB INVERTER (MR)

1

62920

62920

... More
 INCOMER:

-

-

-

... More
: 63A (10KA), 4P, 415 V, 50 Hz. MCB : 1 No. MCB shall be with digital Voltmeter & Ammeter & LED phase indications as per SLD.

-

-

-

... More
 BUS BARS :

-

-

-

... More
: 63A TP + N Aluminium suitable for 1.1 K V with a fault level with-stand: 10 K A for 1 second. The Earth Bus shall be of CU & run contnuously throughout the width of the panel.

-

-

-

... More
 METERING:

-

-

-

... More
 OUTGOINGS :

-

-

-

... More
: 230 V, 50 Hz, 40 A (10KA), 2Pole MCCB : 10 Nos.

-

-

-

... More
: Class B+C surge arrester Panel Make: Vidyut Control (I) Pvt Ltd / Ambit Switchgear / Tricolite

-

-

-

... More
L T CABLE SYSTEM :

-

-

-

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (pwd 2018/501)

-

-

-

... More
4 sq. mm 4 core

-

-

-

... More
6 sq. mm 4 core

-

-

-

... More
10 sq. mm 4 core

175

327

57225

... More
16 sq. mm 4 core

700

343

240100

... More
25 sq. mm 3-1/2 core

-

-

-

... More
35 sq. mm 3-1/2 core

-

-

-

... More
50 sq. mm 3-1/2 core

-

-

-

... More
70 sq. mm 3-1/2 core

75

613

45975

... More
95 sq. mm 3-1/2 core

300

700

210000

... More
120 sq. mm 3-1/2 core

-

-

-

... More
150 sq. mm 3-1/2 core

350

957

334950

... More
185 sq. mm 3-1/2 core

300

1140

342000

... More
240 sq. mm 3-1/2 core

-

-

-

... More
300 sq. mm 3-1/2 core

75

1613

120975

... More
400 sq. mm 3-1/2 core

-

-

-

... More
6 sq. mm 3 core

550

284

156200

... More
12C x 2.5 sq. mm. 2XWY

-

-

-

... More
Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge.(pwd 2018/503)

-

-

-

... More
4 sq. mm 4 core

-

-

-

... More
6 sq. mm 4 core

-

-

-

... More
10 sq. mm 4 core

10

87

870

... More
16 sq. mm 4 core

16

87

1392

... More
25 sq. mm 3-1/2 core

-

-

-

... More
35 sq. mm 3-1/2 core

-

-

-

... More
50 sq. mm 3-1/2 core

-

-

-

... More
70 sq. mm 3-1/2 core

2

199

398

... More
95 sq. mm 3-1/2 core

4

222

888

... More
120 sq. mm 3-1/2 core

-

-

-

... More
150 sq. mm 3-1/2 core

4

305

1220

... More
185 sq. mm 3-1/2 core

8

397

3176

... More
240 sq. mm 3-1/2 core

-

-

-

... More
300 sq. mm 3-1/2 core

2

505

1010

... More
400 sq. mm 3-1/2 core

-

-

-

... More
6 sq. mm 3 core

22

76

1672

... More
Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. (pwd 2018/504)

-

-

-

... More
4 sq. mm

-

-

-

... More
6 sq. mm

66

18

1188

... More
10 sq. mm

40

20

800

... More
16 sq. mm

64

21

1344

... More
25 sq. mm

-

-

-

... More
35 sq. mm

2

31

62

... More
50 sq. mm

4

48

192

... More
70 sq. mm

10

67

670

... More
95 sq. mm

12

88

1056

... More
120 sq. mm

8

117

936

... More
150 sq. mm

14

146

2044

... More
185 sq. mm

24

193

4632

... More
240 sq. mm

-

-

-

... More
300 sq. mm

6

392

2352

... More
400 sq. mm

-

-

-

... More
CABLE TRAYS

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.(DSR-2022)

-

-

-

... More
: 600 mm width X 50 mm depth X 2.0 mm thickness (4.1.7 DSR)

20

1126

22535.2

... More
: 450 mm width X 50 mm depth X 2.0 mm thickness (4.1.6 DSR)

20

937

18757.4

... More
: 225 mm width X 50 mm depth X 1.6 mm thickness (4.1.3 DSR)

20

568

11366.6

-

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR-2022)

-

-

-

... More
: 50 mm (1.21.5 DSR)

10

234

2342.6

... More
: 32 mm (1.21.3 DSR)

100

151

15177

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.(DSR-2022)

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal) (14.16.1 DSR)

100

203

20374

... More
120 mm dia (OD-120 mm & ID-103 mm nominal) (14.16.3 DSR)

650

303

197307.5

... More
EARTHING & LIGHTNING PROTECTION

-

-

-

... More
Supply and burying of 600 mm x 600mm x 6.0mm long G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I pipe and G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonary housing alternate layers of charcoal/coke and salt at alteast 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects.(pwd 218/703)

12

5380

64560

... More
Supply and burying of 600 mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonary housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respects. (pwd 2018/705)

6

10450

62700

... More
Supply & burrying of 32 mm x 6 mm G I strip from earth electrode directly in ground as required complete in all respects.(pwd 2018/717)

190

150

28500

... More
Supply & burrying of 32 mm x 6 mm copper strip from earth electrode directly in ground as required complete in all respects.(pwd 2018/718)

90

1110

99900

... More
INTERNAL LIGHTING

-

-

-

... More
Supply and fixing of recess mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. (Pwd 2018/1402) Make: Havells / Signify / LT / Regent / Jaquar

10

1350

13500

... More
Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Make: Havells / Signify / LT / Regent / Jaquar (Pwd 2018/1403)

10

1870

18700

... More
Supply and fixing of Pendent mounting having 1' X 4' Size 36 to 46 Watt seamlessly intergrateds LED luminier with acrylic sheet diffuser and intergral electronic driver complete in all respects. (Pwd 2018/1416) Make: Havells / Signify / LT / Regent / Jaquar

18

6200

111600

... More
Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect. (Pwd 2018/1417) Make: Havells / Signify / LT / Regent / Jaquar

10

1400

14000

... More
Supply and fixing of 3 Watt LED Path / Walkover Wall Recessed luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. (Pwd 2018/1441) Make: Litolux / Havells / Signify / LT / Regent / Jaquar

45

1810

81450

... More
S.I.T.C. of 60 kva UPS monolithic with isolation transformer inbuilt, model GI - 60 K, 3 Phase input and 3 Phase output witH 150 AH Battery backup 60 minutes, required suitable size wire complete in all respect as per direction of E/I (M.R.)

1

1245000

1245000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.