Lucknow Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Lucknow Development Authority - LDA Tender

Works
Civil And Construction
Excavation
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Oct 2024
Closing Date5 Nov 2024
Tender Amount₹ 12,59,56,685 
Notes
Download

Costs

Summary

Remaining Work (development Work And Electrification Work) Of Sanskriti School Under

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
C. G. CITY YOJNA KE ANTERGAT NIRMANADHEEN SANSKRITI SCHOOL KE AWASHESH KARYA (VIKASH KARYA EVAM VIDHYUTIKARAN KA KARYA)
C. G. CITY YOJNA KE ANTERGAT NIRMANADHEEN SANSKRITI SCHOOL KE AWASHESH KARYA (VIKASH KARYA EVAM VIDHYUTIKARAN KA KARYA)
C. G. CITY YOJNA KE ANTERGAT NIRMANADHEEN SANSKRITI SCHOOL KE AWASHESH KARYA (VIKASH KARYA EVAM VIDHYUTIKARAN KA KARYA)
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement content in M-30 is @ 340 Kg/Cum. Excess/Less cement Used as per design mix is separately.DSR 16.43.2

805.13

7160

5765052.85

... More
Providing and fixing in position pre-moulded joint filler in expansion joints.DSR 16.45

110

165

18150

... More
Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD SOR 504

16.1

54000

869400

... More
PARKING

-

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. DSR 16.1

6014.11

90

541871.31

... More
Construction of granular sub-base by providing close graded Material spreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. PWD

902.12

3220

2904826.4

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. DSR 16.91.2

6014.11

638

3842715.58

... More
Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. DSR 16.63

213.09

382

81411.03

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment. (Precast C.C. kerb stone shall be approved by Engineer-in-charge). DSR 16.69

18.93

5012

94889.46

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.DSR 2.8.1

2527.43

166

420564.35

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) DSR 4.1.8

117.88

4478

527884.32

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level DSR 5.33.1

437.31

6446

2819097.05

... More
Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD 504

10.93

54000

590220

... More
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) DSR 13.7.1

50

226

11340

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25.2

74.93

85

6440.23

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work DSR 13.61.1

5

78

392

... More
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge. DSR 23.9

1198.84

959

1150107.15

... More
COLUMN UPTO 10 FT

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6.

171.12

467

80058.49

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work,including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto plinth level DSR 5.37.1

23.44

6713

157366.78

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1

171.12

468

80101.27

... More
RETAINING WALL

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. DSR 2.8.1

124.02

166

20636.93

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

77.4

125

9733.05

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34

540

185

100413

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1

48.6

131

6410.34

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size). DSR4.1.6

6.84

4814

32931.52

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1

22.93

193

4447.27

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. DSR 5.9.2

114.99

669

76991.55

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6

-

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1

39.78

6713

267067.01

... More
Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level

6.89

54000

372060

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1

52.3

468

24481.63

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm DSR 22.23.2

21

362

7609.35

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone. DSR 22.1.1

590.73

1017

601097.31

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone DSR 22.2.1

1016.23

1253

1273641.06

... More
SKYLIGHT & BRICK WORKS

-

-

-

... More
Providing & fixing of roof with multilayer standing seam polycarbonate panel system of 18mm thickness (min) including all standard fixing accessories on top of the supporting structure (paid extra) complete & as per the direction of the engineer in charge. The panels should work on angular daylighting concept with translucent and opaque combination of louvers inside, for better thermal insulations and diffusion of light especially with white and clear combination designed for tropical regions & shading throughout the day for better ambient temperature below the roof. Panels shall have minimum seven layers with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. The entire panel system shall be with a width from min 1200mm. Bigger width and minimal junctions should be preferred for better performance. Panels shall be manufactured with vertical offset standing seam at both sides of the panel. Panels have to be fixed on purlin with snap on connectors with grip lock double tooth locking mechanism and will be secured on MS Structure/ purlins (will be paid separately) with HDSS Fastener and double tooth polycarbonate connector for best stability and having a pull-out load of min 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Panels cell structure be in truss bridge design or commonly called X structure for better strength and stability. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on polycarbonate panel which have been exposed to UV for a min. of 500 hours as per ASTM G155. Panels shall not have yellowness Index as per ATSMD 1925 of 15 units when tested on a sample exposed to UV for 500 hours as per ASTM G 155. U value shall not be more than 2.0W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cp/ Aluminium U/F profile/ Glazing Bar (all mill finish) for ends as required. Trained and factory authorized layout with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: as per approval.

919.96

3600

3311856

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

18399.29

67

1243792

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2

12.48

5582

69673.97

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR 13.4.2

54.25

168

9127.56

... More
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) DSR 13.5.2

54.25

194

10557.05

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

150.1

87

13111.23

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) DSR 13.46.1

150.1

96

14417.11

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1

919.96

112

103311.51

... More
CHAIN LINK FENCING

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. DSR 2.8.1

81.12

166

13498.37

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

65.34

125

8216.51

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34

326.67

185

60744.29

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1

29.4

131

3877.86

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) DSR 4.1

2.94

4478

13165.76

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1

82.8

193

16059.06

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6

196.8

467

92072.88

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1

12.84

6713

86202.62

... More
Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level

2.83

54000

152820

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade DSR 16.70.2

236.05

594

140367.13

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel rimer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes DSR 10.16

2840.43

93

266716.38

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1

109.09

112

12250.81

... More
M.S. GRILL WORKS

-

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding DSR 9.48.1

1308.91

67

88482.32

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece DSR 10.5.2

7.77

2761

21459.96

... More
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.

20.54

66

1355.64

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25

756

85

64978.2

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1

126.06

112

14156.54

... More
BASEMENT WORK

-

-

-

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

3452.03

199

688472.86

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34

21675.69

185

4030594.56

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1

7586.87

131

1000708.15

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). DSR 4.1.10

1038.7

4209

4371940.24

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick DSR 11.26.1

7586.87

1158

8786354.15

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

758.69

1238

939409.96

... More
BASKETBALL COURT

-

-

-

... More
Concrete Base:- Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation .

192

700

134400

... More
Synthetic Specification: - Providing and laying of ITF Classified material. 8 layers System Synthetic Acrylic for Synthetic Basketball Court:- (1 layer) Conrete Primer (2 layer) Resurfacer (3 layer) Cushion Rubber (4 layer) Top Coat White Line Marking as per standard

192

861

165312

... More
Basketball pole fix type 6” round pipe , Projection 2*20 Acrylic board 20mm Malaysia with dunking ring (3 spring)

1

70000

70000

... More
Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P.

1

320000

320000

... More
Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit.

1

260000

260000

... More
SPORTS FACILITIES

-

-

-

... More
LAWN TENNIS COURT

-

-

-

... More
Concrete Base:-Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation .

1328.58

65

86357.7

... More
Synthetic Specification: -Providing and laying of ITF Classified imported material (AcryCoat Made In Europe) 8 layers System Synthetic Acrylic for Synthetic Court :- • (1 Layer) Concrete Primer • (2 layers) Acrylic Resurfacer • (3 layers) Cushion • (2 layers) Top Coat • Line Marking

1328.58

80

106286.4

... More
Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P

2

320000

640000

... More
Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit.

2

260000

520000

... More
Pole socket type 80*80 mm , thickness (4 mm) with net

2

18500

37000

... More
SKATING RING

-

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. DSR 16.1

528

90

47572.8

... More
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). DSR 16.75

105.6

6912

729923.04

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25.2

1401.75

85

120480.41

... More
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign mater;al etc. and lining out complete. New work (Two or more coats) DSR 16.47.1

46.32

104

4858.97

... More
HORTRICULTURE AND LANSCAPING

-

-

-

... More
Supply and stacking of of good earth at site including royaltyand carriage up to 1 Km DSR 2.2

124.21

332

41306.04

... More
Supply and stacking of sludge at site including royalty and carriage up to 1 Km DSR 2.3

124.21

235

29257.67

... More
Supply and stacking of dump manure from approved source at site including carriage up to 1 Km DSR 2.4.3

124.21

209

25978.52

... More
Rough dressing the trenched ground including breaking of clods DSR 2.5

1863.2

-

1676.88

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.6

931.6

2

2701.64

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.7

1863.2

2

4005.88

... More
Spreading of sludge, dump manure and or good earth and mixing as per direction of engineer incharge DSR 2.8+2.9

1863.2

52

97445.36

... More
Grassing with selection No-1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn. free from weeds and fit for moving and disposal of rubbish as directed DSR 2.10.1

1242.13

10

12918.15

... More
Half brick circular treeguard in brick 1.25 m internal dia and of ht 1.20 m above ground and 0.20 m below ground..... DSR 2.15

10

1419

14197

... More
Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. DSR 2.54

248

47

11804.8

... More
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. DSR 2.56

1242.13

7

8757.02

... More
Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag of size 25 cm as per direction of the officer-in-charge DSR 7.5

5

60

300

... More
Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge DSR 7.24

5

60

300

... More
Supply and stacking of Ficus bengalensis (Bargad) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR 7.28

3

60

180

... More
Supply and stacking of Ficus elastica Decora (Rubber plant) plant of height 45-60 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.DSR 7.31

10

60

600

... More
Supply and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-incharge DSR 7.63

12

650

7800

... More
Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180- 195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge. DSR 7.75

18

100

1800

... More
Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge DSR 2.28

300

267

80130

... More
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge DSR 2.33

600

203

122340

... More
Plumbing Detail

-

-

-

... More
SANITARY FIXTURES

-

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. DSR 17.1.1

3

3392

10178.4

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. DSR 17.78

9

10100

90908.1

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.. DSR 17.80

10

16724

167249.5

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31

10

794

7940

... More
Providing and fixing toilet paper holder : C.P. brass DSR 17.34.1

9

416

3744

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer.

12

6500

78000

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm. DSR 17.10.1.1

1

7052

7052

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore DSR 18.53.1

12

508

6096

... More
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore DSR 18.51.1

12

261

3132

... More
Providing and fixing brass stop cock of approved quality : 15 mm nominal bore DSR 18.16.1

24

261

6264

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72

5

219

1095

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. MR

9

850

7650

... More
Providing and fixing of SS coat hook complete in all respect as approved by Engineer In Charge MR

5

200

1000

... More
Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. DSR 17.70.1

12

495

5940

... More
Providing and fixing of SS grab bar complete in all respect as approved by Engineer In Charge MR

1

1800

1800

... More
Providing and fixing urinal partition chinaware complete in all respect MR

9

750

6750

... More
Providing and fixing of sink mixer complete in all respect. MR

12

4500

54000

... More
Providing and fixing SS labourtory sink as per detail MR

1

4500

4500

... More
Providing and fixing laboratory sink mixer complete in all respect.MR

1

3000

3000

... More
Providing and fixing drinking water sink complete in all respects MR

1

6000

6000

... More
SOIL , WASTE AND VENT SYSTEM

-

-

-

... More
Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as per IS:15905 with stainless steel coupling with EPDM rubber complete in all respect including all required fittings: 75 mm dia

175

1150

201250

... More
Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as per IS:15905 with stainless steel coupling with EPDM rubber complete in all respect including all required fittings : 100 mm dia

1050

1450

1522500

... More
Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as per IS:15905 with stainless steel coupling with EPDM rubber complete in all respect including all required fittings : 150 mm dia

525

1900

997500

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Hubless : 100 mm inlet and 100 mm outlet DSR 17.60.1

1

983

983

... More
Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia. DSR 18.58.1.1

1

49

49

... More
Providing and fixing floor clean out plug consist of CI bend & GI socket heavy class with Brass cap & key for opening male threaded cap etc. including lead caulked to CI pipescomplete in all respects as per drawing / sample approved by Engineer -in -ChargeFCO (floor clean out plug shall be flushed with floor finish : 100 mm dia/150 mm dia

1

600

600

... More
Water Supply system

-

-

-

... More
Inside Toilets

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work. DSR 18.9

-

-

-

... More
15 mm nominal outer dia. Pipes.

800

143

114920

... More
20 mm nominal outer dia. Pipes.

750

163

122475

... More
25 mm nominal outer dia. Pipes.

450

209

94275

... More
Distribution lines

-

-

-

... More
Providing and fixing of GI Pipes medium class IS :1239 including all required fittings etc. DSR 18.12

-

-

-

... More
20 mm dia. nominal bore

90

209

18895.5

... More
25 mm dia. nominal bore

100

257

25730

... More
32 mm dia. nominal bore

175

281

49183.75

... More
40 mm dia. nominal bore

175

334

58476.25

... More
50 mm dia. nominal bore

450

399

179775

... More
65 mm dia. nominal bore

225

524

117956.25

... More
80 mm dia. nominal bore

150

637

95557.5

... More
100 mm dia. nominal bore

530

1350

715500

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore DSR 18.13.1

100

367

36775

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore DSR 18.13.2

25

761

19027.5

... More
Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). DSR 18.14

1

315

315

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore: DSR 18.17

30

428

12865.5

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. DSR 18.17.2

30

501

15046.5

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore DSR 18.17.3

35

585

20492.5

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore DSR 18.17.4

4

750

3003

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore DSR 18.17.5

8

1287

10302

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore DSR 18.17.6

5

1920

9603

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore DSR 18.18.1

45

288

12982.5

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore DSR 18.18.2

45

409

18445.5

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore DSR 18.18.3

20

449

8999

... More
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.

1

193

193

... More
Providing and fixing submrsible vertical drainage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control. Status (w+s) 1 working + 1 stand by solid hanldling 40 mm size.discharge 5 lps and head-15 mtr

4

55000

220000

... More
Providing and fixing submrsible vertical sewage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control. Status (w+s) 1 working + 1 stand by solid hanldling 40 mm size.discharge 5 lps and head-15 mtr

3

65000

195000

... More
RAIN WATER SYSTEM

-

-

-

... More
Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 100 mm dia

100

950

95000

... More
Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 150 mm dia

400

1500

600000

... More
Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 200 mm dia

100

1800

180000

... More
Making of 600x600 mm size khurah complete in all respects including water proofing etc.

30

1250

37500

... More
EXTERNAL SEWARAGE AND DRAINAGE

-

-

-

... More
GARDEN IRRIGATION

-

-

-

... More
Providing and fixing HDPE pipes conforming to IS:4984 PE 63 Class IV (6 kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and screwed adoptors, welded joint as per manufacturers recommendations.

-

-

-

... More
a) 32 mm O.D.

48

200

9600

... More
b) 40 mm O.D.

48

250

12000

... More
c) 63 mm O.D.

100

350

35000

... More
Providing and fixing uPVC Schedule 40 pipes conforming to ASTM D-1785 complete with uPVC Schedule 40 fittings including necessary cutting of pipes, jointing with HDPE pipe with sadddle fitting complete with testing and commissioning of pipe lines : (a) 1" nominal size

10

450

4500

... More
Providing and fixing 25 mm brass dia quick coupling valve fitting with auto-close lid, SS spring, brass valve, complete in all respects (Harit model HT-71B or eq.).

10

1105

11050

... More
Providning and fixing bronze ball valve with screwed female/flanged ends with stainless steel valve and spindle, glass fileed tefelon seating and gland packing, quarter turn lever operate full bore design, hydraulically tetsed to 20 kg/sqcm

-

-

-

... More
a) 25 mm nominal bore

6

911

5466

... More
b) 40 mm nominal bore

3

1726

5178

... More
a) 50 mm nominal bore

2

2157

4314

... More
Providing and fixing cast iron flanged wafer type butterfly Valve with quarter turn operation complete in all respects confirming to IS:13095 PN1.0: (a) 65 mm dia

1

4794

4794

... More
Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. cover 500x450 mm R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design.

4

5945

23780

... More
Providing and fixing 15 mm N.B. air release valve alongwith FTA I/c 1 no. ball valve for fixing to HDPE pipeline complete

8

1725

13800

... More
Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. surface box 100 mm top dia 160 mm bottom dia and 180 mm deep (inside) with chained lid and R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design.

8

5178

41424

... More
SEWERAGE

-

-

-

... More
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia.

849

153

129897

... More
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (b)Extra over 1 (a) above for excavation over 1.5 m depth .

450

158

71100

... More
Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (a) 200 mm OD

559

950

531050

... More
Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (b) 250 mm OD

160

1250

200000

... More
Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (c) 300 mm OD

130

1850

240500

... More
Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. :(a) 200 mm OD

100

500

50000

... More
Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. (b) 250 mm OD

50

650

32500

... More
Providing and fixing square mouth S.W. gully trap grade 'A' complete with C.I. Grating brick masonary chamber with bricks of class designation 75 and water & gas tight SFRC Cover with frame of 260x260 mm size clear opening, frame of size 390x390 mm with weight of frame to be not less than 10 Kg and cover of size 300x300 mm with weightof cover not to be not less than 9 Kg as per standard design: (a) 180X 150 mm size P type with F.P.S. bricks of class designation 75

15

3500

52500

... More
Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks

10

6000

60000

... More
Extra for depth beyond 45 cm of brick masonary chamber : for 455X610 mm size : With F.P.S. bricks

0.5

3068

1534

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar1:3 ( 1 cement :3 coarse sand ) finished with floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement 3 Coarse sand: 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement all complete as per standard design: 0.91 m deep with SFRC cover and frame ( Heavy duty HD-20 grade designation) 560mm internal diameter conforming to IS:12592 total weight of cover and frame to be not less than 182 kg, fixed in cement concrete1:2:4 (1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. (excavation, foot rests and 12 mm thick cement plaster at the surface shall be paid seperately): with F.P.S. bricks class desigantion 75

34

10067

342278

... More
Extra depth for circular type manhole 0.91 m internal dia (at bottom) with beyond 0.91 m to 1.67 m, with F.P.S. bricks class designation 75

12

3452

41424

... More
DRAINAGE SYSTEM

-

-

-

... More
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia.

842

153

128826

... More
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (b) Pipes, cables etc. exceeding 300 mm dia.

100

158

15800

... More
Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (a) 200 mm OD

237

950

225150

... More
Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (b) 250 mm OD

334

1250

417500

... More
Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (b) 300 mm OD

271

1850

501350

... More
Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (a) 200 mm OD

50

500

25000

... More
Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (b) 250 mm OD

75

650

48750

... More
Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size ) neatly finished with a floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (a) Inside size 90X80 cms and 60 cms deep including SFRC cover with frame (heavy duty) 500 mm dia clear opening

15

8629

129435

... More
Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size ) neatly finished with a floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (b) Inside size 120X90 cms and 90 cms deep including SFRC cover with frame (Extra heavy duty) 560 mm dia clear opening.

11

15000

165000

... More
Extra for additional depth of manholes: (a) Size 90X80 cms beyond 60 cms depth

5

3500

17500

... More
Extra for additional depth of manholes: (b) Size 120X90 cms beyond 90 cms depth

4

4500

18000

... More
Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks

5

7670

38350

... More
Constructing brick masonary road gully chamber 50X45X60 cm with bricksof class designation 75 in cement mortar 1:5 (1 cement: 5 fine sand) including 500X450 mm precast RCC horizontal grating with frame complete as per standard design:With F.P.S. bricks

95

5500

522500

... More
Making connection of stormwater lines with existing municipal manhole including breaking into and  making good the walls,  floors  with  cement concrete 1:2:4 mix (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement and making  necessary channels for the drain etc. complete: (a) For pipes 250 to 450 mm diameter

1

10000

10000

... More
FIRE FIGHTING WORKS

-

-

-

... More
FIRE FIGHTING

-

-

-

... More
Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C' (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. 'Providing protection to embedded M.S pipes and fittings by wrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(a) 80 mm dia ( 4.85mm thickness)

60

1200

72000

... More
Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C' (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. 'Providing protection to embedded M.S pipes and fittings by wrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(b) 100 mm dia ( 5.40mm thickness)

10

1550

15500

... More
Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C' (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. 'Providing protection to embedded M.S pipes and fittings by wrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(c) 150 mm dia ( 5.40mm thickness)

450

2000

900000

... More
Supply, Installation, Testing and Commisioning of butterfly valve suitable for working pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts & gaskets complete required.:(a) 100 mm dia

6

4500

27000

... More
Supply, Installation, Testing and Commisioning of butterfly valve suitable for working pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts & gaskets complete required.:(b) 150 mm dia

10

5500

55000

... More
Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitable for working pressure of 15 Kg/Sqcm & test pressure 30kg/sqcm with flanges, Nut, bolts & washers, painting etc. complete as required.:(a) 100 mm dia

2

4500

9000

... More
Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitable for working pressure of 15 Kg/Sqcm & test pressure 30kg/sqcm with flanges, Nut, bolts & washers, painting etc. complete as required.:(b) 150 mm dia

5

6000

30000

... More
Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:( a) 65 mm dia

2

5200

10400

... More
Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:(b) 150 mm dia

5

9200

46000

... More
Supply, Installation, Testing and Commisioning of C.I.`Y' strainer with bronze perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers, complete as required.: (a) 150 mm dia

5

15500

77500

... More
Supply, Installation, Testing and Commisioning of SS single head fire hydrant valve with 80 mm N.B. flanged inlet, brass spindal, one no. 63 mm dia female instantaneous outlet type. G.M. coupling,blank cap, chain. Conforming to IS:5290. Including tapping from wet riser complete as required.

10

4500

45000

... More
Supply, Installation, Testing and Commisioning of Hose pipe, 63 mm dia and 15 mts long, duly reinforced, rubber lined suitable for brusting pressure not less than 22 Kg/Sqcm. conforming to IS 636-1988 type A with gun metal heavy duty instantaneous type coupling ( Pair male & female parts) conforming to IS 903. Complete as required.

20

4200

84000

... More
Supply, Installation, Testing and Commissioning of 63 mm dia instantaneous pattern branch short SS pipe, 16 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.

10

1500

15000

... More
Supply, Installation, Commisioning of standard firemans axe with heavy rubber handle.

10

500

5000

... More
Supply, Installation, Testing and Commissioning of inlet breaching having C.I. body four way SS 63 mm dia instantaneous inlets conforming to IS 903 fitted with non return valves, 25 mm dia gun metal drain cock, blank cap, brass chains and 150 mm dia flanges with all accessories suitable for local fire tender complete as required.

5

7500

37500

... More
Supply, Installation, Testing and Commissioning of SS Fire Brigade adopter assembly with 150 mm dia outlet, suitable for local fire tender complete as required.

1

6500

6500

... More
Supply, Installation, Testing and Commissioning of weather proof cabinet of size not less than 0.6 x 0.6 x 0.45 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside 'with the letters "FIRE HOSE" including necessary locking arrangement and painting in red colour suitable to accomodate, external yard hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle and fire man's axe. It shall be mounted on boundary wall complete as required.

10

1950

19500

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.: Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.: M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head

1

367296

367296

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump): Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.: 2280 lpm at 70 m Head

1

610297

610297

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) : Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.: Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.: M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.: Suitable cement concrete foundation duly plastered and with anti vibration pads. : 180 lpm at 70 m Head

1

102391

102391

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :

-

-

-

... More
INCOMING: 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc: LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING: ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.

-

-

-

... More
Jockey Pump : 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL

-

-

-

... More
Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

245730

245730

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe

1

13822

13822

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

1

18009

18009

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

2

1508

3016

... More
FINISHING WORK

-

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) DSR 21.1.1.2

279.09

384

107310.11

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Powder coated aluminium (minimum thickness of powder coating 50 micron)DSR 21.1.2.2

45.36

444

20180.66

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides DSR 21.2.2

23.18

866

20087.79

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness: DSR 21.3.2

30.9

1003

31022.06

... More
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125x75x4 mm: DSR 9.95.1

16

118

1891.2

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm: DSR 9.96.1

8

212

1699.6

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm: DSR 9.97.1

8

99

797.6

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm: DSR 9.100.1

8

51

408.8

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.: Twin rubber stopper: DSR 9.101.2

4

38

152

... More
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.: Two or more coats on new work: DSR 13.42.1

307.3

53

16333

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. (Material shall conform to ASTM 6063). : Floor Joint of 100 mm gap: DSR 5.44.1

1008.5

4741

4781348.93

... More
Providing and fixing of expansion joint system related with wall joint (internal / external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.) : Wall Joint of 100 mm gap:DSR 5.45.1

295.2

3928

1159545.6

... More
Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) : Roof Joint of 100 mm gap : DSR 5.46.1

136

4392

597393.6

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

342

450

154019.7

... More
CONNECTING BRIDGE

-

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR 10.2

120791.14

67

8165481.06

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25

2506.58

85

215440.55

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62

5393.37

112

605675.45

... More
ROOF SKYLIGHT -18 mm THK POLYCARBONATE SHEET Supply and Installation of polycarbonate multi-layered, Multicell Xfix Connectible modular panel system for, a complete assembly of coextruded UV protected polycarbonate panels incorporated into a complete system. Standing seam polycarbonate panel system of minimum 18 mm thick (Min.) Panels with bigger width will be preferred for reducing number of joints in the roof. Panels shall be with grip lock double tooth locking mechanism with interlocking connectible connectors running lengthwise at both sides of the panel. Panels shall be fixed on Purlins of MS tructure (will be paid Separately) with self-drilling screws and specials Trapezoidal Heavy Duty Fastener/ Al- Cleat to ensure a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005. The min width of the panel system shall be 900mm (min.).

-

-

-

... More
Panels shall be uniform in color UV protected in combination with seven layers for required lux level, along with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels with more layers will be preferred for better insulation and improved shading coefficient. Prices includes All accessories including Aluminum profiles with EPDM Gaskets, at alternate edges with taper cutting to achieve the required profile, aesthetics and performance criteria. U value shall not be more than 1.8 Watt/m2K as per EN ISO 1077- 2:2018 and respective third Party test certificate shall be produced before procurement.

-

-

-

... More
Panels shall have an X cell structure also called truss bracing design to have more strength and flexibility simultaneously. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G155.Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factoryauthorized labour with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge.

280.38

3600

1009368

... More
LEVELLING

-

-

-

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. SOR 2.31

24830.12

199

4952119.13

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.32

32570.01

7

234504.07

... More
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.33

32570.01

3

118880.54

... More
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. : Beyond 60 cm girth upto and including 120 cm girth: SOR 2.33.2

30

972

29181

... More
EXTERNAL ELECTRICAL

-

-

-

... More
COMPACT SUB STATIONS - 01 (with OLTC)

-

-

-

... More
Supply, Installation, testing and Commissioning of 11 kV / 0.415 KV Compact Sub Station (with OLTC) outdoor plinth mounted type designed for natural cooling having type tested equipment comprising distribution transformers, SF6 insulated VCB compact switchgear (RMU) having metal enclosed robotically sealed/welded stainless steel tank , L T Panel, interconnection between HT switchgear & Transformer using single core cables and Transformer to LT switchgear using Al bus bars/Cables factory built / ready for connection type, other associated equipment etc. complete as required conforming to detailed specification.

-

-

-

... More
The enclosure shall have modular construction using G.I. sheets and shall be painted with polyurethane paint from the exterior of approved shade. The enclosure for LT switchgear & HT switchgear shall be provided with IP54 ingress protection. The transformer compartment will have IP23 ingress protection. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment.Transformer compartment door shall be interlocked with HT breaker. The transformer used shall be specially designed for low losses and shall be hermetically sealed & with corrugated tank.

-

-

-

... More
The L T ACB shall have inbuilt microprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases with Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947

-

-

-

... More
L T Panel BUS : 415 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C.

-

-

-

... More
The Transformer losses should confirm to IS - 1180 Part-1 (2014) efficiency Level - 2 [ 1.86 KW at 50% load & 5.3 KW at 100% load shall not exceeds by 5.0% of the maximum total loss values.

-

-

-

... More
The combination of CSS shall be as per details below:-

-

-

-

... More
(a) Supply of 3 way 11kV , 3Phase, 50Hz, 3 wire , earthed neutral, Indoor type floor mounted, non extensible, having hinged arc proof cable doors, breaking capacity 18.4 kA, VCB Ring Main Unit enclosed in robotically laser welded stainless steel tank having IP67 degree of protection consisting of following:-

-

-

-

... More
(i) 1 Nos. 630Amps Fault making load breaking spring assisted SF6 Ring Switches, fitted with fixed type voltage indicator device as per IEC 61958 along with associated sensor and fault passage indicator. (ii) 2 No. 630Amps tee off spring assisted type vacuum circuit breaker unit with self powered series trip microprocessor based numerical over current and Earth fault relay for protection, fitted with fixed type voltage indicator device as per IEC 61958, along with associated sensor and fault passage indicator and ring core type protection Current transformer along with LV compartment with Ammeter with selector switches. (iii)Air Insulated Metering panel connected along with above unit , 18.4 kA , 630 amps, having Potential transformer, connected jumpers / Bus Bar, LV Compartment to incorporate Votmeter and Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI as per the requirement (at incoming VCB) (Please refer SLD).

-

-

-

... More
(b)1 No. 11 KV/415 V, 630 KVA three phase (with %Z is 4.5%) , 50 HZ, DYn11, +10% to -10% in 2.5% equal steps ON LOAD TAP CHANGER (OLTC), oil cooled, outdoor mounting type, hermitically sealed, corrugated wall design low loss transformer with Cu winding and standard fittings.(minimum 240 Sq MM HT (E) XLPE AL cable are used for the connectivity between transformer & HT Breaker)

-

-

-

... More
LT Bus Bars : 1000 AMP, 500 Volts, 3 phase 50 HZ TPN. The current density of bus bar shall not exceed 1.0 sqmm / Amp

-

-

-

... More
Neutral Bus : - Separate 2 nos 32 x 6 mm Copper insulated strip (with conductivity mim 99%) directly connected from neutral point of transformer.

-

-

-

... More
(c )Incoming cum Outgoing - 415 Volt L.T. breaker Panel having 1000 Amp FP ACB, 50 kA fixed type, with microprocessor based O/L, E/F, S/C, Inst. S/C releases with CT/PT, ammeter with ASS, Voltmeter with VSS, PF meter, Hz meter, energy enalyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI, phase indicating lamps, On/Offf/Trip indication. 630 KVA Compact Sub Station.

2

2275000

4550000

... More
DIESEL GENERATING SET

-

-

-

... More
Supply, Installation, testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization / PLC based load manager, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following.

-

-

-

... More
Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.

-

-

-

... More
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :

-

-

-

... More
Start stop switch with key Water temperature indication Lubrication oil pressure indication. Lubrication oil temperature indication. Battery charging indication RPM indication Over speed indication Low Lube oil trip indication Engine hours indication

-

-

-

... More
Alternator - Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required.

-

-

-

... More
Note : - Alternator should have with all other accessories as per specified in Technical specfications.

-

-

-

... More
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer. Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete. Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required. Exhaust Silencer - Exhaust manifold with residential silencer. The D G set should be supplied with required hardware for external PLC based auto load management system. Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH. Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.

-

-

-

... More
550 KVA

1

6300000

6300000

... More
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The measurement shall be done on the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will be confirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval): 300 mm dia (wall thickness - 4.85 mm) (for 625 KVA DG sets)

240

5000

1200000

... More
Supply & fixing of SS Bellow of following diameter : 300 mm dia (for 500 KVA DG sets)

21

22500

472500

... More
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation.

3000

60

180000

... More
FUEL PIPING

-

-

-

... More
Providing and fixing in position the following MS pipes class"C" (As per IS : 1239) cut to required lenghts and installed with screwed joints including providing and fixing in position the necessary fittings like elbows, tees and reducers, sockets, MS supports and accessories including digging and refilling earth where required for buried pipes / suspended from ceiling including pipe hanger / clamped from wall including hardware complete as per site requirement.: 25 mm NB MS pipes (IS: 1239, 4.0 mm thick)

75

345

25875

... More
Providing & fixing of hand lever operated forged brass body full way ball valve type isolating valve having forged brass hard chrome plated mirror finish ball, steel handle with PVC grip, teflon seat, screwed ends tested to a pressure of 10 kg/sqcm suitable for HSD complete.:25 mm nominal bore

3

825

2475

... More
Supply, installation, testing and commissioning of Fuel Level sensor (for Low & high level)

3

4000

12000

... More
MAIN LT PANEL & SUB DISTRIBUTION PANELS

-

-

-

... More
Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.

-

-

-

... More
INCOMING- 800 Amp. MCCB-1 Nos. OUTGOINGS - 1 nos. 200 AMPS TP MCCB. (25 KA) 2 no. 100 AMPS TP MCCB. (25 KA) 2 nos. 63 AMPS TP MCCB. (25 KA) 1 nos. 200 AMPS TP MCCB. (25 KA) (for spare) 1 nos. 100 AMPS TP MCCB. (25 KA) (for spare) 1 nos. 63 AMPS TP MCCB. (25 KA) (for spare)

2

584400

1168800

... More
AUTOMATIC POWER FACTOR CORRECTION PANEL (CAPACITOR PANEL)

-

-

-

... More
Supply, Installation, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 200 KVAR A P F C Panel consisting of 5 / 10 / 15 / 20 / 25 / 50 KVAR at 415 Volts (rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 All outgoings MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release. All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified is Ics value. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's, etc

-

-

-

... More
Capacitor duty contactors should be used for switching individual capacitor banks. The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec. Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose. The capacitor panel shall be integrated with the main L T Panel as per schematic diagram

-

-

-

... More
INCOMING Incomer circuit breaker has been included in the main panel. 1 set- 3 CTs , ratio 600/5A Class 1.0 accuracy 15 VA burden for metering. 1Nos- (0-600A) digital Ammeter with selector switch Micro processor based automatic power factor control relay (3 phase) (including power factor meter) in 9 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be provided with in the scope of work. Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit. BUS BARS 600 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar with conductivity on min 57 to 58% of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints. The current density of bus bar shall be minimum 1.0 sq mm / amp. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature.

-

-

-

... More
OUTGOINGS - 2 nos. of 125 AMPS TPN 25 KA MCCB and 150 amps AC3 duty contactor with 50 KVAR heavy duty MPP type at 415 V capacitor bank (rated Voltage 440 Volts) , auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 2 nos. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 duty contactor with 25 KVAR heavy duty MPP type at 415 V capacitor bank (rated Voltage 440 Volts) , auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 1 no. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 duty contactor with 20 KVAR heavy duty MPP type at 415 V capacitor bank (rated Voltage 440 Volts) , auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 1 no. of 40 AMPS TPN 25 KA MCCB and 50 amps AC3 duty contactor with 15 KVAR heavy duty MPP type at 415 V capacitor bank (rated Voltage 440 Volts) , auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 1 no. of 32 AMPS TPN 25 KA MCCB and 40 amps AC3 duty contactor with 10 KVAR heavy duty MPP type at 415 V capacitor bank (rated Voltage 440 Volts) , auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 1 no. of 16 AMPS TPN 25 KA MCCB and 20 amps AC3 duty contactor with 5 KVAR heavy duty MPP type at 415 V capacitor bank (rated Voltage 440 Volts) , auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 1 SET 200 KVAR CAPACITOR PANEL

2

312000

624000

... More
Electrical Panel-1 (Block-1) Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. INCOMING- 400 Amp. MCCB-1 Nos. OUTGOINGS - 100 AMP MCCB 2 nos. 63 AMP MCCB 8 nos. 40 AMP MCCB 8 nos. 63 AMP MCCB 1 no. (spare) 40 AMP MCCB 1 no. (spare)

1

199172

199172

... More
Electrical Panel-2 (Block-2) Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving andmounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. INCOMING- 200 Amp. MCCB-1 Nos. OUTGOINGS - 100 AMP MCCB 2 nos. 63 AMP MCCB 5 nos. 40 AMP MCCB 6 nos. 63 AMP MCCB 1 no. (spare) 40 AMP MCCB 1 no. (spare)

1

138070

138070

... More
Electrical Panel-3 (Block-3) Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and otherparameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 813 (E) INCOMING- 400 Amp. MCCB-1 Nos. OUTGOINGS - 100 AMP MCCB 2 nos. 63 AMP MCCB 8 nos. 40 AMP MCCB 8 nos. 63 AMP MCCB 1 no. (spare) 40 AMP MCCB 1 no. (spare)

1

199172

199172

... More
Electrical Panel-4 (Block-4) Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/ 812 (C) INCOMING- 200 Amp. MCCB-1 Nos. OUTGOINGS - 100 AMP MCCB 2 nos. 63 AMP MCCB 6 nos. 40 AMP MCCB 6 nos. 63 AMP MCCB 1 no. (spare) 40 AMP MCCB 1 no. (spare)

1

138070

138070

... More
Electrical Panel-5 (Block-5) Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/813(E) INCOMING- 400 Amp. MCCB-1 Nos. OUTGOINGS - 100 AMP MCCB 2 nos. 63 AMP MCCB 6 nos. 40 AMP MCCB 6 nos. 63 AMP MCCB 1 no. (spare) 40 AMP MCCB 1 no. (spare)

1

199172

199172

... More
Lighting Panel for Basement : Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 / 811 (C) INCOMING- 100 Amp. MCCB-1 Nos. OUTGOINGS - 63 AMP MCCB 2 nos. 40 AMP MCCB 5 nos. 63 AMP MCCB 1 no. (spare) 40 AMP MCCB 1 no. (spare)

1

109943

109943

... More
UPS O/G Panel: Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as perIS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/811 (C) INCOMING- 100 Amp. MCCB-1 Nos. OUTGOINGS - 63 AMP MCCB 2 nos. 40 AMP MCCB 2 nos. 40 AMP MCCB 18 no. 25 AMP MCCB 18 no. 40 AMP MCCB 1 no. (spare) 25 AMP MCCB 1 no. (spare)

3

109943

329829

... More
CO2 Gas Flooding System For Main LT Panel Supply, installation, testing and commissioning of Polymer Tube Detection based CO2 Gas Flooding System For Main LT Panel, Consisting of the following components: CO2 Cylinder, 4.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility).

1

41381

41381

... More
CO2 Cylinder, 2.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility).

1

48514

48514

... More
Filling adopter

2

2553

5106

... More
D/I Adopter for converting the indirect valve to function as Direct System.

2

4774

9548

... More
FET End of Line adapter with Pressure gauge for Automatic fire uppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Fitting made by brass (plated / unplated), Stainless steel, Elastomeric Sealings, Copper Nickle plated, Temperature range TS -20 Deg C till + 60 Deg C, Maximum working pressure 25 Bars, made as per PED Pressure Equipment Directives.

2

4774

9548

... More
Pressure Switch to monitor Pressure drop in the tube, switch point 11 Bars.

2

6195

12390

... More
Flexible Polymer Detection Tube made by special modified Polyamide (PA), Color Red, High grade quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM, Melting Point approx. 220 degrees Celsius when heating up with 10 K/minute, Steady load tested upto max. 80° C. The lowest operating temperature is stipulated at minus 40°C. Service Pressure 20 Bar, Burst Pressure at 20 Deg C approx 120 Bars, Release Temperature : Rapid heat increase in temperature at 20 bars pressure approx 150 Deg to 180 Deg C (Without Flame)

75

766

57450

... More
Master Control Unit for connecting each system with electronic hooters and productivity input to Scada /Fire Alarm system including all necessaries +electrical wiring to make each entire system functional.(Indeginous)

2

13405

26810

... More
Containing all required fitting and fixing

2

2553

5106

... More
Installation & Commissioning Charges includes complete setup of the system, Installation of Cylinders on specially designed brackets, Laying of sensor tubes using tube attachments and Cable ties, fixing end of line plugs and end of line adapters, pressurizing tube @ 15-18 Bars using Nitrogen pressurizing agent.

2

9603

19206

... More
Supplying and fixing and connection of the following rating, four Pole MCCB (25 KA), 415 volts, at the incomer / outgoing in seperate enclosure, complete with connections, testing and commissioning etc. as required : 100 AMP FP MCCB (25 KA) micro processor based.

3

18000

54000

... More
(VI) INVERTOR Supply, installation, testing and commissioning of on line UPS with builtin parallal redundancy, as per following details Technology : Micro processor based controls, True on line, Double conversion type, should have cold start facility. Input :- (mains / local D G set compatibility) a) Voltage : 415 V / 3 Phase b) Voltage Variation : - 20% to + 20% c) Input Frequency : 50 Hz. d) Frequency Variation : + 10% e) Automatic phase sequence correction facility Output :- a) Voltage : 230 V / 1 Phase, 415 V / 3 Phase b) Voltage Variation : + 1% c) Frequency Variation : 50 Hz. + 0.1% Overall Efficiency : 90% Charger : Should have built in charger to suit system requirement. Battery type : Sealed Maintenance Free - SMF (Global Yuasa / Exide) Battery Backup = 15 min. External battery backup will be used Display : Should have LCD display with event logging facility. Upgradeability : Should be upgradeable to work as parallel redundant UPS in load sharing mode. Software Communication : Should have SNMP (Simple Network Management Protocol) compatibility Rating : 30 KVA

3

350000

1050000

... More
SUB-HEAD - 1 : S/F MODULAR TYPE SWITCH / SOCKET & SUBMAINS

-

-

-

... More
Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.DSR 1.57

369

533

196677

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. DSR 1.14

-

-

-

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (DSR 1.14.4)

17435

227

3957745

... More
2 X 16 sq. mm + 1 X 6 sq. mm earth wire (DSR 1.14.6)

350

408

142800

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire (DSR 1.14.9)

330

395

130350

... More
4 X 10 sq. mm + 2X6 sq. mm earth wire (DSR 1.14.10)

427

536

228872

... More
SUB-HEAD - 2 : DISTRIBUTION BOARDS & CIRCUIT BREAKERS

-

-

-

... More
S/F of surface / flush mounting SPN Distribution board with additional metal door without MCB complete in all respects as directed at site by Engineer-in-charge. a) 12 WAYS CAT A (UPSOR 1025(A)

7

2250

15750

... More
S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. (a) 4 WAYS CAT A (UPSOR 1026 (A)

6

3610

21660

... More
S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. 6 WAYS : CAT A (UPSOR 1027(A)

6

4370

26220

... More
S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. : 8 WAYS: CAT A (UPSOR UPSOR 1028(A)

1

5210

5210

... More
Supply & fixing of 6/10/16/20/25/32 amp. SP MCB (10 KA) : CAT A(UPSOR 1002

46

260

11960

... More
Supply & fixing of 63 Amp DP MCB (10 KA) :CAT A : UPSOR 1011

7

1180

8260

... More
S/F of 63 amp FP MCB (10 K.A.) :CAT A : UPSOR 1020 (A)

13

2290

29770

... More
S&F and making connection of 63A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.UPSOR 394

7

2950

20650

... More
S&F and making connection of 63 Amp. 4 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. UPSOR 398

13

2960

38480

... More
Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. UPSOR 1109

7

85

595

... More
S&F single pole MCB blanking plate UPSOR 1034(B)

242

25

6050

... More
SUPPLY AND LAYING OF CABLES & ACCESSORIES

-

-

-

... More
Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor byclamps etc UPSOR (501)

-

-

-

... More
6 sqmm 3 core

1

284

284

... More
10 sqmm 4 core

1

327

327

... More
16 sqmm 4 core

10

343

3430

... More
25 sqmm 3 1/2 core

250

373

93250

... More
35 sqmm 3 1/2 core

150

422

63300

... More
50 sqmm 3 1/2 core

85

492

41820

... More
95 sqmm 3 1/2 core

120

700

84000

... More
120 sqmm 3 1/2 core

285

824

234840

... More
150 sqmm 3 1/2 core

10

957

9570

... More
185 sqmm 3 1/2 core

250

1140

285000

... More
240 sqmm 3 1/2 core

2552

1379

3519208

... More
300 sqmm 3 1/2 core

1315

1613

2121095

... More
deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required.

5000

-170

-850000

... More
Supply fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge (UP SOR 504)

-

-

-

... More
6 sqmm

1

18

18

... More
10 sqmm

1

20

20

... More
16 sqmm

2

21

42

... More
25 sqmm

68

27

1836

... More
35 sqmm

18

31

558

... More
50 sqmm

8

48

384

... More
70 sqmm

4

67

268

... More
95 sqmm

16

88

1408

... More
120 sqmm

86

117

10062

... More
150 sqmm

18

146

2628

... More
185 sqmm

30

193

5790

... More
240 sqmm

132

272

35904

... More
300 sqmm

54

392

21168

... More
Supply and fixing brass nickle plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor UPSOR 503

-

-

-

... More
6 sqmm 3 core

1

76

76

... More
10 sqmm 4 core

1

87

87

... More
16 sqmm 4 core

2

87

174

... More
25 sqmm 3 1/2 core

4

123

492

... More
35 sqmm 3 1/2 core

6

178

1068

... More
50 sqmm 3 1/2 core

2

178

356

... More
95 sqmm 3 1/2 core

2

222

444

... More
120 sqmm 3 1/2 core

14

243

3402

... More
150 sqmm 3 1/2 core

2

305

610

... More
185 sqmm 3 1/2 core

10

397

3970

... More
240 sqmm 3 1/2 core

44

473

20812

... More
300 sqmm 3 1/2 core

18

505

9090

... More
Supply of ISI marked Copper conductor PVC insulated cable as per IS 1554 armoured, served, sheathed 1100 volts grade. : 25 sqmm 1 core

540

350

189000

... More
Laying and testing of aluminium / copper conductor cable PVC / XLPE insulated armoured, served, sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray or inside existing RCC / HDPE DWC pipe complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) / end terminations to the cable leads, insulating with tape and making connections with brass / nickle plated flame proof double compression glands, providing cable tags complete in all respect upto the satisfaction of Engineer-incharge. (The supply of terminations and glands shall be under seperate item): (a) 25 sqmm 1 core

540

50

27000

... More
Supply and laying of ISI marked Copper conductor PVC insulated control cable as per IS 1554 PVC sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections complete in all respect including end termination, double compression glands, supply of clamps, lugs, tape etc complete upto the satisfaction of Engineer-incharge. Armoured

-

-

-

... More
6 x 2.5 sq mm armoured (DG to Main LT panel interfacing)

100

212

21200

... More
12 x 2.5 sq mm armoured (2 runs DG controlling)

100

356

35600

... More
12 x 2.5 sq mm armoured ( For Transformer contro wiring)

100

350

35000

... More
2 x 4 sq mm armoured (for Battery charging)

50

150

7500

... More
Supply of 3 core stranded aluminium conductor 11 KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments) a) 240 sq. mm 3 core

35

1280

44800

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of following size in the existing masonry open duct etc. as required. a) Size exceeding 120 sq. mm. But not exceeding 400 sq. mm.

35

56

1960

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core

5

6457

32285

... More
Supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories includinglugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core

1

9464

9464

... More
CABLE TRAY

-

-

-

... More
Supply and erection of Perforated type cable trays made out of prefabricated Galvanized sheet steel including tees, bends, crossings, reducers, couplings to be laid in cable trenches or installed over head on wall or hanged from ceiling including all neccessary supports, brackets at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts & bolts complete in all respects.: The support for 1000mm, 900 mm and 750 mm wide cable tray will be by 50 x 50 x 6 mm MS angle, for 600mm and 450 mm wide cable tray will be by 40 x 40 x 5 mm MS angle, for 300mm wide cable tray will be by 32 x 32 x 5 mm MS angle, for 150mmwide cable tray will be by 25 x 25 x 4 mm MS angle.

-

-

-

... More
900 mm (W) X 50 mm (H) X 2 mm (T)

10

1500

15000

... More
750 mm (W) X 50 mm (H) X 2 mm (T)

10

1250

12500

... More
600 mm (W) X 50 mm (H) X 2 mm (T)

25

1000

25000

... More
450 mm (W) X 50 mm (H) X 2 mm (T)

65

850

55250

... More
300 mm (W) X 35 mm (H) X 1.5 mm (T)

60

750

45000

... More
150 mm (W) X 35 mm (H) X 1.5 mm (T)

160

500

80000

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required..

-

-

-

... More
90 mm dia (OD-90 mm & ID-76 mm nominal) (DSR 14.16.2)

700

163

114100

... More
160 mm dia (OD-160 mm & ID-135 mm nominal) DSR 14.16.4)

100

313

31300

... More
MISCELLANEOUS ITEMS EXTERNAL ELECTRICAL

-

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm x 150 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.21)

6

149

894

... More
Providing and fixing H.V. danger notice plate of 250 mm x 200 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.22

4

163

652

... More
S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M) UPSOR 1134

2

235

470

... More
Supply and fixing of Fist aid box as approved by Indian red cross conforming to IS : 2217.

2

1000

2000

... More
Supply of rubber gloves of 11 KV grade as per IS : 4770.

2

500

1000

... More
Supply and fixing of cable route maker as directed by Engg-incharge. UPSOR 505

4

340

1360

... More
Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality. to withstand 30 KV dielectric strength as per IS 15652 complete in all respects. (For LT Panels) UPSOR 1136

13

2525

32825

... More
Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality to withstand 45 KV dielectric strength as per IS 15652 complete in all respects. (For 11 KV Panels) UPSOR 1136

2

2525

5050

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.a) 300 mm dia. DSR 14.14.4

400

592

236800

... More
Supply and erection of pregalvanized Ladder type cable trays made out 25mm x 75mm x 25mm x 2.5mm GI Section all along (as runner) and 20mm x 30mm x 20mm x 2.5 mm GI Section (as rungs) at every 250mm interval c/c including tees, bends, crossings, reducers, couplings to be laid over head on wall or hanged from ceiling including all neccessary supports, brackets (50x50x6 MS Angle) at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts & bolts complete in all respects.

-

-

-

... More
900 mm (W) X 75 mm (H)

30

1500

45000

... More
750 mm (W) X 75 mm (H)

15

1250

18750

... More
EARTHING

-

-

-

... More
BODY / SAFETY EARTHING (FOR BODY OF ALL ELECTRICAL EQUIPMENTS LIKE RISING MAINS, TRANSFORMER, DG SETS,LIFTS ETC.

-

-

-

... More
Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling. The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound. (borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6 mm. Further GI strips from equipments shall be connected to Copper strips by means of special bi-matellic connector (i.e. stainless steel). please refer submitted drawing.

34

5500

187000

... More
Providing & fixing 25mm x 5mm G.I. strip on surface, in recess or in ground including connections etc. as required (LT Panel,Cable Trays & Elevator). DSR 5.15

2420

129

312180

... More
Providing & fixing 32mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (Pig tail) UPSOR 717

60

150

9000

... More
Providing & fixing 50mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (SubstationGrid)

75

250

18750

... More
NEUTRAL EARTHING

-

-

-

... More
Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling. The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound.(borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6 mm. please refer submitted drawing.

10

5500

55000

... More
Providing & fixing 32mm x 6mm insulated Copper strip on surface, in recess or in ground including connections etc. asrequired.

135

2000

270000

... More
SOLAR PLANT

-

-

-

... More
ON-Line Solar Photovoltaic system plant including suitable rating Poly crystalline Silicon PV Modules having a efficiency of minimum 15% (without any power export arrangement), String combiner box, DC Distribution board etc. complete as required. Scope of work also includes supply, installation of GI structure, (80 micron) in suitable section complete with all accessories and hardware including civil work as required at site for mounting PV panels.: 15 kWp SET 1 70 415 V, 3 phase, 50 Hz AC power string inverter (Grid intractive) with stand & all protection and controls having overall efficeiency of not less than 95%. : 15 kWp (nominal) SET 1 71 AC distribution board made of 2 mm CRCA sheet, power coated having IP55 degree of protection (for indoor installation) for terminating 415 V, 3 phase, 50 Hz power suppled from inverter complete height with following multifunction: - Digital multifunction meter (EM 6400 of Schnieder or equal) - 40 Amp TPN MCB (10 KA) - Phase indicating lamps. SET 1 Lighting Arrestor SET 1 Surge Protector SET 1

1

1018080

1018080

... More
STREET / EXTERNAL LIGHTING

-

-

-

... More
Supply & fixing of 20 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 410 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. (UPSOR 653)

4

314000

1256000

... More
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect. Category AAA (UPSOR 1455)

24

22750

546000

... More
Supply and fixingof LED Street light Fitting having die cast aluminium body and diffuserwith driver set suitable for 45 watt to 50 Watt. Confirmingto IP 65 and above protectioncomplete in all respect. Category AAA (UPSOR 1443)

62

8410

521420

... More
Supply and fixingof 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminiumbody with drive set . Confirming to IP 65 and above Protection complete in all respect. Category AAA (UPSOR) MR

12

2470

29640

... More
Supply and fixingof 3 Watt to 4 Watt LED Spot/Spike light Confirming to IP 65 and above Protection complete in all respect. Category AAA (UPSOR 1441)

8

1850

14800

... More
Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 and above protection complete in all respect. Category AAA

50

6810

340500

... More
Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect.

62

15280

947360

... More
Supply installation, testing and commissioning of 3x2.5 sqmm flexible fire retardant copper connecting wire of required length from MCB in cable junction box of pole to luminaire along with MCB & Connector complete as required.

62

870

53950.54

... More
Supply & burrying of 40 mm dia x 4.50 m long G.I. pipe vertically for earthing having 12 mm dia holes spaced 75 mm apart drilled upto 2 meter brom the bottom complete with one earthing lead of no. 6 to 8 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switchboard (from apron to switch board the cost of GI pipe & GI wire will be extra), 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect.

10

3660

36600

... More
Supply & burrying of 600mm x 600 mm x 6.0 mm G.I. plate, vertically for pole earthing with its top at least 3 m below ground level complete 20mm dia. G. I. pipe and funnel for watering and one earthing lead of no. 8 to 10 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switch board (from apron to switch board the cost of GI pipe & GI wire will be extra) 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .

6

5380

32280

... More
Supplying & Laying of one number 8 SWG G. I. wire in 15 mm. dia. G. I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P and other material required for proper completion of the work as directed at site.

100

157

15700

... More
Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.

-

-

-

... More
INCOMER :

-

-

-

... More
f (ii) 40 AMP TPN MCB (10 KA)

1

29300

29300

... More
e (ii) 25 AMP TPN MCB (10 KA)

1

26500

26500

... More
OUT GOINGS :

-

-

-

... More
4 nos. 6-32 AMP DP MCB (10 KA)

-

-

-

... More
24 nos. 6-32 AMP DP MCB (10 KA)

-

-

-

... More
Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. 10 sqmm 3 core

3200

93

298912

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Size not exceeding 35 sq. mm.

2200

206

453200

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. Size not exceeding 35 sq. mm.

500

97

48500

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe etc. as required. Size not exceeding 35 sq. mm.

500

18

9000

... More
Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. e) 6 sqmm 3 core

2200

284

624800

... More
Deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required.

300

-170

-51000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.