Lucknow Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Lucknow Development Authority - LDA Tender

Works
Coronavirus COVID 19
Eprocure
Opening Date24 Dec 2019
Closing Date7 Jan 2020
Tender Amount₹ 3,91,48,532 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Bijnaor Marg Par Sharda Nagar Vistar Yojna mein Pradhanmantri Awas Yojna ke Antergat Bhawano avam Bhukhando Hetu 2 x 5 MVA 33/11 KV Vidhyut Sub Station ka Nirman Karya
Bijnaor Marg Par Sharda Nagar Vistar Yojna mein Pradhanmantri Awas Yojna ke Antergat Bhawano avam Bhukhando Hetu 2 x 5 MVA 33/11 KV Vidhyut Sub Station ka Nirman Karya.
Bijnaor Marg Par Sharda Nagar Vistar Yojna mein Pradhanmantri Awas Yojna ke Antergat Bhawano avam Bhukhando Hetu 2 x 5 MVA 33/11 KV Vidhyut Sub Station ka Nirman Karya.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
H.V. PANEL (33 KV - VCB PANEL)

-

-

-

... More
SITC of Indoor arc-proof Draw-Out Vacuum Circuit Breaker Panel, rated for 33kV, 1250Amp, 31.5kA/3-sec, comprising of 2no. Incomer, 1 No. Bus Coupler and 04Nos. Outgoing fully encapsulated pole VCB Panels, confirming to IEC 62271-200, Internal Arc Classified IAC AFLR – 31.5kA for 1sec, Accessibility Class LSC2B-PM Class, comprising of 1250Amp, continuous rated Copper busbars and droppers, 01nos. Rack-In-Rack-Out Handle, structure made from AluZinc/GI sheets to prevent corrosion and rusting. The complete panel incl. HT and LT chamber shall be manufactured by approved OEM at its own facility, and same will be verified via stage/final inspection. License parter, system integrator, panel builder, half-panel concept is not allowed. The Board shall consist of following panels: (Make : ABB/Schneider/Simense/CGL ) (PSR)

-

-

-

... More
(A) INCOMER : 2 NOS. 1250 AMP VCB (i) 33kV, 1250Amp, 31.5kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03 Nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC) (ii) Current Transformers 33kV, 800-400/1-1, Core1: Class 5P10, 5VA, Core2: Class 0.5, 5VA, - Set of 03nos. The 'PS' core will be of suitable knee point voltage and ratio so as to succesfully implement Transformer Differential protection scheme for the upstream power transformer. (iii) Potential Transformers, rear and bottom Draw-out type for easy maintenance, 33kV/rt3:110V/rt3, 25VA, Cl.0.5 with associated gun-type HRC fuses and MCBs for HT/LT isolation - Set of 03nos. (iv) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having 04CT+05PT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like

2

-

1020000

... More
(1) directional over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) residual and three-phase under-voltages/over-voltages (4) Synchronism and Energizing Check before breaker closing to prevent un-syncronized mixing of supplies (5) circuit-breaker-failure alarm, (6) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Line-Voltage etc. and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with power & frequency measurements and suitably labelled status LEDs. TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.

-

-

-

... More
(v) Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) (vi) Indications - LED for Breaker ON/OFF/TRIP/Spring-Charged/R-Y-B, 08-Window Annunciator with hooter (vii) Control Equipment incl. 01 x TNC Switch, 01 x Emergency Trip Push Button, MCBs for AC/DC isolation as required (viii) Other accessories incl. Space Heater with thermostat for breaker, busbar, LV panel and cable chamber, 3-Pin socket with switch, CFL lamp. (ix) Suitable Disconnecting Link type terminal arrangement shall be provided for interfacing PS-Class CTs installed in the panel with Transformer differential relay situated in the 33kV CRP for achieving the required protection.

-

-

-

... More
(B)OUTGOINGS : 4 NOS. 1250 AMP VCB - (PSR)

4

-

943000

... More
(i) 33kV, 630Amp, 31.5KA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC) (ii) Current Transformers 33kV, 200/1-1, Core1: Class 5P10, 5VA, Core2: Class 0.5, 5VA - Set of 03nos.

-

-

-

... More
(iv) Main Protection Relay shall be a Numerical Drawout Transformer Differential IED Relay communicable on IEC 61850 GOOSE platform over RJ-45 port, microprocessor based protection scheme for detecting, indicating and tripping the breaker on various faults like (a) Transformer Differential, (b) Restricted Earth Fault protection, The Relay shall have complete bay control features incl. Large LCD display for displaying Feeder SLD (position indication), integrated ON/OFF control function, three phase current measurement, disturbance recorder, event log and fault record with non-volatile memory, self-supervision. The relay shall have sufficient analogue channels to receive all CT-inputs to achieve Differential and REF protection (i.e. atleast 07nos), with internal summation and vector matching capability. The relay shall have sufficient binary inputs and outputs to receive and issue external commands. The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. Breaker On/Off/Spring.Chrgd, Line-Current, Master Trip, Trip Circuit Failure (from TCS relay), OTI Alarm/Trip, WTI Alarm/Trip, Buccholz Alarm/Trip, PRV Trip, Low Oil Level Alarm and display locally on a built-in back-lit LCD screen as a Single-Line-Diagram with parameters as advised. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.

-

-

-

... More
(v) Back up Protection Relay shall be numerical IED Relay confirming to IEC60255, having microprocessor based protection scheme for tripping the breaker on various faults like (1) over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) thermal runaway in cables monitored via simulated temperature control, (4) circuit-breaker-failure alarm, (5) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. The relay shall be fully integrated with the feeder, internally capturing feeder statuses and Line-Currents and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with current measurements and suitably labelled status LEDs. TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.

-

-

-

... More
(v) Metering Equipment incl. 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) (vi) Indications - LED for Breaker ON/OFF/TRIP/Spring-Charged, 12-Window Annunciator with Ackn/Test/Reset push button and Hooter to indicate following alarms :- (a) OTI Alarm/Trip (b) WTI Alarm/Trip (c) Buccholz Alarm/Trip (d) PRV Trip (e) Low Oil Level Alarm (f) OC Trip Alarm (g) EF Trip Alarm (h) Trip Circuit Failure (k) Transformer Differential Trip Alarm (l) Restricted Earth Fault Trip Alarm (vii) Control Equipment incl. 01 x TNC Switch, 01 x Emergency Trip Push Button, MCBs for AC/DC isolation as required (viii) Other accessories incl. Space Heater with thermostat for breaker, busbar, LV panel and cable chamber, 3-Pin socket with switch, CFL lamp.

-

-

-

... More
(C) BUS COUPLER CUM BUS RISER: (B) 01 x BusCoupler Panel, each comprising of :- (i) 33kV, 1250Amp, 31.5KA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC) (ii) Current Transformers 11kV, 600/1-1, Core1: Class 5P10, 5VA, Core2: Class 0.5, 5VA Set of 03nos.

1

-

1570000

... More
NOTE :- The all above panel consist of the followings:-

-

-

-

... More
(i) Complete panel will be ready for future SCADA integration via industrial grade ethernet switch capturing feeder data via respective IED numerical relays which will also allow peer-to-peer communication over IEC 61850 GOOSE platform, resulting in implementation of required inter-panel interlocks/inter-tripping measures as required by engineer-in-charge. (ii) Foundation frames shall be inclusive in the scope of supply of OEM. (iii) Suitable Disconnecting cum Shorting Link type terminal arrangement in Incomer panels shall be provided for interfacing PS-Class CTs installed in the panel with upstream Transformer differential relay situated in the 33kV CRP for achieving the required protection. Knee point voltage, CT-Ratio and other details to be submitted by manufacturer.

-

-

-

... More
(iv) All Incomers and BusCouplers will have suitable schemes in place to prevent mixing of un-syncronized supplies using Line/BusPT signals. Any such attempt will be reported by a suitable alarm. This facility should be implemented over soft-logic, and can be disabled by authorized personnel without requiring any on-site re-wiring. (v) All Outgoing VCBs will have inter-tripping logic in place to ensure that Incomer breaker immediately trips in case of failure of opening of outgoing VCB experiencing feeder fault. Special and dedicated Alarm shall be in place to issued the user. This facility should be implemented over soft-logic, and can be disabled by authorized personnel without requiring any on-site re-wiring.

-

-

-

... More
H.V. PANEL (11 KV - VCB PANEL)- (PSR)

-

-

-

... More
Supplying, installing, testing and commissioning of Indoor arc-proof Draw-Out Vacuum Circuit Breaker Panel, rated for 11kV, 1250Amp, 26.3kA/3-sec, comprising of 2no. Incomer, 01no. Bus Coupler and 12 Nos. Outgoing fully encapsulated pole VCB Panels and Bus PTs for each bus section, confirming to IEC 62271-200, Internal Arc Classified IAC AFLR – 26.3kA for 1sec, Accessibility Class LSC2B-PM Class, comprising of 1250Amp, continuous rated Copper busbars and droppers, 02nos. Rack-In-Rack-Out Handles, structure made from AluZinc/GI sheets to prevent corrosion and rusting. The complete panel incl. HT and LT chamber shall be manufactured by approved OEM at its own facility, and same will be verified via stage/final inspection. License parter, system integrator, panel builder, half-panel concept is not allowed. The Board shall consist of following panels:(Make :-ABB/Schneider/Simense/CGL )

-

-

-

... More
(A) Incomer Panel, each comprising of :- (i) 11kV, 1250Amp, 26.3kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03 Nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC) (ii) Current Transformers 11kV, 600/300/1-1-1, Core1: Class 5P10, 5VA, Core2: Class 0.5, 5VA, Core3: Class PS-X - Set of 03nos. The 'PS' core will be of suitable knee point voltage and ratio so as to succesfully implement Transformer Differential protection scheme for the upstream power transformer. (iii) Potential Transformers, rear and bottom Draw-out type for easy maintenance, 11kV/rt3:110V/rt3, 25VA, Cl.0.5 with associated gun-type HRC fuses and MCBs for HT/LT isolation - Set of 03nos. (iv) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having 04CT+05PT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like :-

2

-

580000

... More
(1) directional over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) residual and three-phase under-voltages/over-voltages (4) Synchronism and Energizing Check before breaker closing to prevent un-syncronized mixing of supplies (5) circuit-breaker-failure alarm, (6) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Line-Voltage etc. and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with power & frequency measurements and suitably labelled status LEDs. TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.

-

-

-

... More
(v) Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) (vi) Indications - LED for Breaker ON/OFF/TRIP/Spring-Charged/R-Y-B, 08-Window Annunciator with hooter (vii) Control Equipment incl. 01 x TNC Switch, 01 x Emergency Trip Push Button, MCBs for AC/DC isolation as required (viii) Other accessories incl. Space Heater with thermostat for breaker, busbar, LV panel and cable chamber, 3-Pin socket with switch, CFL lamp. (ix) Suitable Disconnecting Link type terminal arrangement shall be provided for interfacing PS-Class CTs installed in the panel with Transformer differential relay situated in the 33kV CRP for achieving the required protection.

-

-

-

... More
(B) 01 Nos BusCoupler Panel, each comprising of :- (i) 11kV, 1250Amp, 26.3KA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC) (ii) Current Transformers 11kV, 600/300/1-1, Core1: Class 5P10, 5VA, Core2: Class 0.5, 5VA Set of 03nos.

1

-

745000

... More
(iii) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having 04CT+05PT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like (1) directional over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults. (3) Synchronism and Energizing Check before bus-coupler closing to prevent un-syncronized mixing of supplies (4) circuit-breaker-failure alarm. (5) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Line-Voltage etc. and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with power & frequency measurements and suitably labelled status LEDs. TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.

-

-

-

... More
(iv) Metering Equipment incl. 01 x Digital Ammeter (Acc.Cl.0.5) (v) Indications - LED for Breaker ON/OFF/TRIP/Spring-Charged, 08-Window Annunciator with hooter (vi) Control Equipment incl. 01 x TNC Switch, 01 x Emergency Trip Push Button, MCBs for AC/DC isolation as required (vii) Other accessories incl. Space Heater with thermostat for breaker, busbar, LV panel, 3-Pin socket with switch, CFL lamp. (viii) Min. 08-port ethernet switch to ensure star-coupler connection with numerical IED relays via CAT5/6 cables. - 02no. (ix) Suitable bus-riser panel with matching busbar to connect with the remaining bus-section comprising of BusPT 11kV/rt3:110V/rt3, 25VA, Cl.0.5 with associated gun-type HRC fuses and MCBs for HT/LT isolation - Set of 03nos. Space Heater with Thermostat included. The respective section bus-voltage will be measured using Digital Voltmeter (Acc.Cl.1.0) and R-Y-B Phase LED indications. Isolation MCB and related wiring included

-

-

-

... More
(C) Outgoing Panel, each comprising of :- (i) 11kV, 630Amp, 26.3KA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC) (ii) Current Transformers 11kV, 400/200/1-1, Core1: Class 5P10, 5VA, Core2: Class 0.5, 5VA - Set of 03nos.

6

-

536000

... More
(iv) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having microprocessor based protection scheme for tripping the breaker on various faults like (1) over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) thermal runaway in cables monitored via simulated temperature controle (4) circuit-breaker-failure alarm, (5) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. The relay shall be fully integrated with the feeder, internally capturing feeder statuses and Line-Currents and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with current measurements and suitably labelled status LEDs. TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.

-

-

-

... More
(v) Metering Equipment incl. 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) (vi) Indications - LED for Breaker ON/OFF/TRIP/Spring-Charged, 04-Window Annunciator with Hooter (vii) Control Equipment incl. 01 x TNC Switch, 01 x Emergency Trip Push Button, MCBs for AC/DC isolation as required (viii) Other accessories incl. Space Heater with thermostat for breaker, busbar, LV panel and cable chamber, 3-Pin socket with switch, CFL lamp.

-

-

-

... More
(D) 01Nos Bus PT Panel, each comprising of : (i) Suitable bus-riser with matching busbar to connect with the bus-section comprising of BusPT 11kV/rt3:110V/rt3, 25VA, Cl.0.5 with associated gun-type HRC fuses and MCBs for HT/LT isolation - Set of 03nos. Space Heater with Thermostat included. The respective section bus-voltage will be measured using Digital Voltmeter (Acc.Cl.1.0) and R-Y-B Phase LED indications. Isolation MCB and related wiring included-

2

-

492000

... More
NOTE :- The all above panel consist of the followings:-

-

-

-

... More
(i) Complete panel will be ready for future SCADA integration via industrial grade ethernet switch capturing feeder data via respective IED numerical relays which will also allow peer-to-peer communication over IEC 61850 GOOSE platform, resulting in implementation of required inter-panel interlocks/inter-tripping measures as required by engineer-in-charge. (ii) Foundation frames shall be inclusive in the scope of supply of OEM. (iii) Suitable Disconnecting cum Shorting Link type terminal arrangement in Incomer panels shall be provided for interfacing PS-Class CTs installed in the panel with upstream Transformer differential relay situated in the 33kV CRP for achieving the required protection. Knee point voltage, CT-Ratio and other details to be submitted by manufacturer.

-

-

-

... More
(iv) All Incomers and BusCouplers will have suitable schemes in place to prevent mixing of un-syncronized supplies using Line/BusPT signals. Any such attempt will be reported by a suitable alarm. This facility should be implemented over soft-logic, and can be disabled by authorized personnel without requiring any on-site re-wiring. (v) All Outgoing VCBs will have inter-tripping logic in place to ensure that Incomer breaker immediately trips in case of failure of opening of outgoing VCB experiencing feeder fault. Special and dedicated Alarm shall be in place to issued the user. This facility should be implemented over soft-logic, and can be disabled by authorized personnel without requiring any on-site re-wiring.

-

-

-

... More
33 KV / 11 KV TRANSFORMER Supply of Outdoor mounted type 33KV/11KV, 5 MVA Transfomer (as per IS : 2026), 3 phase, Dyn 11 vector group, 50 cycles, ONAN, with OLTC & RTCC panel, oil immersed naturally cooled, step down, double copper wound, temperature rise 50/55 degree C and other standard accessories as required including followings : (Make : Transfix India/Raychem RPG/Schneider/CGL ) -RA

2

-

6185025

... More
a) Cable Termination box with disconnecting facility for 33 KV XLPE cable at 33 KV side.

-

-

-

... More
b) Cable Termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side.

-

-

-

... More
c) On Load Tap Changer +/- 7.5 % @ 2.5 %

-

-

-

... More
d) Bi directional rollers

-

-

-

... More
e) Conservator with drain valve

-

-

-

... More
f) earthing terminals.

-

-

-

... More
g) double diaphragm explosion vent.

-

-

-

... More
h) Radiator with top & bottom shut off valve.

-

-

-

... More
I) First filling of oil including make up fill.

-

-

-

... More
j) Silica gel breather with oil seal.

-

-

-

... More
k) Rating and Diagram plate.

-

-

-

... More
l) Air release plug.

-

-

-

... More
m) Buchholz relay with shut off valve.

-

-

-

... More
n) Winding temperature indicator. (WTI)

-

-

-

... More
o) Oil temperature indicator. (OTI)

-

-

-

... More
p) Magenatic oil level gauge.

-

-

-

... More
q) Pressure relief device.

-

-

-

... More
r) Marshalling box.

-

-

-

... More
The work shall be complete in all respects up to the satisfaction of Engg-in-charge.

-

-

-

... More
Installing in correct aligned position effecting proper connections, testing & commissioning of Outdoor mounted type 33KV/11KV 5 MVA Transfomer complete with all interconnections, construction of foundation and masonry platform of suitable size in 1:4 Brick work and 1:2:4 cement conctere & fencing alround transformer as per standard design as per manufacturers specifications complete in all respects. (PSR)

2

-

250000

... More
TRANSFORMER 100 KVA -PSR

-

-

-

... More
Supply, storing, inspection, handling, assembling, installing in correct aligned position effecting proper connections, testing & commissioning of Outdoor mounted type 11KV/433V ,100KVA Transfomer (as per IS : 1180 Type-2), 3 phase, 5% impedance at 75 degree C, Dyn 11 vector group, 50 cycles, (ONAN) oil immersed naturally cooled, step down, double Alluminium wound, continuous duty, temperature rise 50/55 degree C and other standard accessories as required including followings (Make : Kotsons/ MEI/Mahindra )

1

-

192200

... More
a) Cable Termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side.

-

-

-

... More
b) Cable Termination box with disconnecting facility for required nos. LT cable at LT side.

-

-

-

... More
c) Off Load Changer +/- 7.5 % @ 2.5 %

-

-

-

... More
d) Bi directional rollers

-

-

-

... More
e) Oil Conservator with drain valve

-

-

-

... More
f) earthing terminals.

-

-

-

... More
g) double diaphragm explosion vent.

-

-

-

... More
h) Radiator with top & bottom shut off valve.

-

-

-

... More
I) First filling of oil including make up fill.

-

-

-

... More
j) Silica gel breather with oil seal.

-

-

-

... More
k) Rating and Diagram plate.

-

-

-

... More
l) Air release plug.

-

-

-

... More
p) Magenatic oil level gauge.

-

-

-

... More
r) Marshalling box.

-

-

-

... More
The work shall be complete in all respects up to the satisfaction of Engg-in-charge.

-

-

-

... More
Making Brick Work in 1:4 cement Core sand for 100 KVA transformer plinth of 1.2X1.2X1.0 Mt size (as per Attached design ) including 12 mm thick Plaster providing all the civil material, labour, T&P all as per Direction of E/Ic.- PSR

1

-

7740

... More
Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting, M.S. channel base with bottom and top cable entreis elctrical control panel with TPN MCCB's (Four pole 36 KA with thermal magnatic release) switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F., KW etc.) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium bus bars as per IS8623 or above instulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. - PSR The Job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above shall have an ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. cubicle type switch board shall be of cat A. & B. only.

1

-

138070

... More
INCOMING- 200 Amp MCCB -1 Nos

-

-

-

... More
OUT GOINGS : 100 AMP MCCB -1 Nos, 63 AMP MCCB -3 Nos

-

-

-

... More
33 KV CABLES Supply / Laying of 3 core 300 sqmm stranded aluminium conductor 33KV grade XLPE (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable complete in all respect as per direction of E/I. (Make : Polycab / CCI / Havells/KEI) - PSR

400

-

2049

... More
Supply and making heat shrinkable type Indoor end termination Kit of 33 KV XLPE cable. (Make : Dansen / 3 M / Mseal / Raychem) ,3 x 300 sq. mm Indoor Kit complete in all respect as per direction of E/I.

8

-

25786

... More
Supply and making heat shrinkable type outdoor end termination Kit of 33 KV XLPE cable. (Make : Dansen / 3 M / M-seal / Raychem) 3 x 300sq. mm Outder Kit complete in all respect as per direction of E/I.

2

-

38089

... More
11 KV CABLES Supply / Laying of stranded aluminium conductor 11KV grade XLPE (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable complete in all respect as per direction of E/I. (Make : Polycab / CCI / Havells/KEI) - PSR

-

-

-

... More
(i) 70 sq. mm 3 core

100

-

591

... More
(ii) 240 sq. mm 3 core

1200

-

1214

... More
(III) 400 sq. mm 3 core

200

-

1757

... More
Supply and making heat shrinkable type Indoor end termination Kit of 11 KV XLPE cable.complete in all respect as per direction of E/I. (Make : Dansen / 3 M / M-seal / Raychem) -PSR (i) 70 sqmm 3 core

2

-

8706

... More
(ii) 240 sq. mm 3 core

12

-

10562

... More
(III) 400 sq. mm 3 core

8

-

11235

... More
Supply and making heat shrinkable type outdoor end termination Kit of 11 KV XLPE cable. (Make : Dansen / 3 M / M-seal / Raychem) -PSR

-

-

-

... More
(i) 70 sqmm 3 core

2

-

12016

... More
(ii) 240 sq. mm 3 core

12

-

14344

... More
LT CABLES S/L of 16 Sqmm 4 Core Aluminium conductor, PVC insulated, armoured, served, sheathed cable 1100 volts grade at a depth of 750mm below ground level lay in existing pipe(Pipe cost charged Extra)on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E\I. Complete in all respected. The armouring of the cable shall be properly connected with the earth conductor by clamps. SOR/2018/501-507 16 sqmm 4 core

400

-

173

... More
95 sqmm 3 1/2 core

100

-

530

... More
S/F of plain/pin type copper tin plated cable socket (Lugs) to the cable lead insulating with tape and making connection etc. complete in all respect.SI no. 504/18

-

-

-

... More
(i) 16 mm2

150

-

21

... More
(ii) 95 mm2

100

-

88

... More
COPPER EARTHING Supply & burrying of 600mm x 600mm x 6 mm copper plate, vertically for earthing with its top at least 3 meters below ground level complete with 20 mm G.I. pipe for watering funnel, 300 mm square C.I. frame with hinged cover, masonry housing, alternate layers of coke and salt at least 150 mm thick alround including excavation and back filling etc. complete in all respects.(PWD SI No-704 ,2018)

10

-

10170

... More
Providing & fixing 50 mm x 6mm Copper strip as earth mat / earth strip on surface, in recess or in ground including connections etc. as required.

100

-

958

... More
LIGHTNING PROTECTION OF BUILDING Supply & burrying of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 meters below ground level complete with 20 mm G.I. pipe for watering funnel, 300 mm square C.I. frame with hinged cover, masonry housing, alternate layers of coke and salt at least 150 mm thick alround including excavation and back filling etc. complete in all respects. PSR

15

-

5350

... More
Providing & fixing G.I.strip 32 mm x 6 mm thick on parapet or surface of wall for lighting conductor as required ( For horizontal / Vertical run ) (PWD SI No-717 ,2018)

150

-

150

... More
MISCELLANEOUS ITEMS Providing and fixing H.V. danger notice plate of 250 mm x 200 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required .- PSR

15

-

200

... More
S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work.(PWD SI Nos-1134/2018)

4

-

305

... More
Supply and fixing of First aid box as approved by Indian red cross conforming to IS : 2217.- PSR

4

-

1000

... More
Supply of rubber gloves of 11 KV grade as per IS : 4770. PSR

20

-

250

... More
Supply and erection of ISI marked portable fire extinguishers, wall mounted type, wall brackets complete in all respect, including fixing on walls as per the direction of engineer in charge. (MAKE : Minimax/Real Value/Firex/Safex) A B.C.. type. 6 KG.capacity (S.I. Nos -1131 A/2018)

6

-

9100

... More
Supplying and Fixing of CO2 gas type. 6.5 kg. capacity fire extinguisher along with all materials and labour for proper completion of work as per direction of E/I. (S.I.Nos-1132 A/2018)

6

-

19900

... More
Supplying and Fixing of 4 set of Fire buckets with MS pedestal stands suitable for supporting 4 fire buckets of approved quality, painted red confirming to IS:2546 with all accessories complete in all respects-.PSR

6

-

5000

... More
Supplying, Fixing, Testing, Commissioning of 1800 mm x 900 mm x 12mm thick chequered rubber matting of tested quality to withstand 11/ 33 KV dielectric strength complete in all respects.(PWD- SI Nos-1136/ 2018)

20

-

2550

... More
Supply, installation, testing and commissioning of lead acid Battery bank for 33 and 11 KV swith gear panels for 24 volts DC supply complete with necessary boost and float charger of rating 24 volt 110 AH with DC distribution Board with laid acide battery set, MCB's, necessary interconnecting FRLS grade copper wiring as required complete in all respects.-PSR

2

-

108280

... More
11 KV RING MAIN UNIT Providing 11 KV, 630 amp, 21 KA for 3 sec, outdoor mounting Ring Main Unit having hinged arc proof cable doors, cable termination from the front enclosed in robotically sealed/welded stainless steel tank having IP 67 degree of protection comprises of 11kV outdoor type non extensible CCV type Compact switchgear unit in SF6 enclosure having 2 No. 630 amp fault making type load break switches along with earthing switches and 1 Nos. 630 amp vacuum circuit breaker in SF6 enclosure with Self powered numerical relay (IDMTL O/C + E/F ) as HT switchgear along with earth switch. (Make : ABB/Schneider/Crompton ) -PSR

3

-

393645

... More
Installation, testing and commissioning of 11 KV Ring Main Unit complete with all interconnections, construction of foundation and masonry platform of suitable size in 1:4 Brick work and 1:2:4 cement conctere as per manufacturers specifications complete in all respects. -PSR

3

-

37490

... More
Providing, Laying and fixing following dia RCC pipe NP 2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 ( 1 cement : 2 fine sand ) including trenching (75 cm deep) and refilling etc. as required. -PSR 150 mm dia.

100

-

501.4

... More
Providing, Laying 150 mm thick PCC 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate) all round RCC pipes for cable laying. The PCC shall be cured as required.

-

-

-

... More
150 mm diameter RCC Pipe (0.192 CuM / RM)@Rs.6850/=(Civil PWD SOR ,2017-279b)

100

-

6000

... More
STREET LIGHT POLES AND LUMINAIRS CABLES ETC. S/F of 7m GI Octagonal poles with single Arm Bracket designed as per ILE TR7 & BS5649 for structural design & as per IS 875 (Part III) 1987 for Dynamic loading. The pole shaft shall be made single piece MS structure continuously tapered having polygonal (8/12 Sides) cross section and a single longitududinal welding.The welding will be done as per BS 5135/IS 9595. No circumferential welding shall be allowed In the pole shaft. The MS shall confirm to BSEN 100025/100027.The structure shall be single hot dip galvanized as per BS 729/IS 2629. A suitably designed door shall be provided at approximate 600mm height from the pole base. The door opening will be suitably reinforced for structural strength. The door shall be flushed with pole external surface and shall provide easy access for eletrical connections at a maintainable height. A suitable base flange and a top flange will be welded and suitable reinforcement will be provided. Foundation accessories will be as per IS 1367.(Including Plinth)(Make :Bajaj/Philips/Crompton/Vallmount ) SOR/641/2018

10

-

16500

... More
Dimensional Data:

-

-

-

... More
MS Sheet thickness : 3mm

-

-

-

... More
Galvanization thickness : 65 Microns (min)

-

-

-

... More
Door size : 250 mm X 65mm

-

-

-

... More
Pole Height : 7 m

-

-

-

... More
Top diameter : 75mm (min)

-

-

-

... More
Bottom diam : 130mm (min)

-

-

-

... More
Base Flange thickness : 16 mm (min.)

-

-

-

... More
Base plate Diemention : 260mm X 260 mm X 16mm

-

-

-

... More
Foundation Bolts:

-

-

-

... More
Nos. 4

-

-

-

... More
Length 750 mm

-

-

-

... More
Diam : M24

-

-

-

... More
Supply and fixing of 2 metres high cage fabricated with 3 mm thick expanded metal fixed on 50 mm x 50 mm x 6 mm angle iron frame having vertical members spaced at 1 to 1.25 mts. and horizontal members spaced at 1mt. The vertical members shall be grouted in floor and horizontal members in the wall to a depth of 300 mm with ends forked. The cage shall have 2000mm x 1000mm size one leaf door with locking device having door frame fabricated with 35mm x 35mm x 6mm angle iron and 3mm expanded metal duly fixed with the cage member with hinge etc. the cage shall be painted with red oxide primer and synthetic enamel paint. The job includes all materials, labour T & P etc. for proper completion of work.- PSR

15

-

1275

... More
Supply and fixing of LED street light fitting having die cast aluminium body and diffuser/reflector with driver set suitable for 90 watt. (100 luman per watt)Confirming to IP 66 protection complete in all respect. ENDURA PLUS of Havells or equivalent make approved in UPPWD .(PWd, SOR-1423/2018)

10

-

8850

... More
S\L of HDPE (DWC) pipe includind coupler for road crossing etc. (except for cable support on poles) at depth of 750mm below ground level for LT cable and 900mm below ground level for HT cable as cable carrier as per E/I (Make Dura – line or Reck) 50 mm (ID) .- (PSR)

300

-

110

... More
S/F of 40A. TPN capacity of automatic Street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 Series with contactors HRC fuses, isolating Switch metering instrument box with CTS etc. in case of TPN, Complete in all respect as per approval by E/Ic.(PWD, SOR-807- F/2018)

1

-

29300

... More
Supply and laying of 80mm dia G.I. 'B' class pipe as cable carrier as per direction and approval of E/Ic.- (PSR)

50

-

590

... More
S/F of 6 amp single pole MCB ,Havells make all complite as per direction of E/Ic CAT-A(PWd, SOR-1002/2018)

10

-

260

... More
For Boundry Wall Construction Of 33/11 Kv Substation Boundry Wall 1.5 Mtr. Height with 1:4 Cemant & Coarse Sand (1 cement : 4 Coarse sand) With One No.R.C.C.Column After 3 mtr All Complete As Per Direction By The E/IC.(PSR)

200

-

5506

... More
Mild steel or iron work in heavy sizes such as trusses built up gates, door frame, record racks, roof work,gates etc. wrought to required from including drilling holes, riveting or welding where necessary and also including supply of steel, bolts, nuts etc. & their fixing required for proper completion of the work.(For Two No.Gate)PWD sor no-503 year-2017

10

-

5850

... More
S/F of 1200 mm size ceiling fan Bajaj/Poler/Crompton/Havells make all complite as per direction of E/Ic. - PSR

10

-

2002

... More
cable trench Construction of cable trenches with bricks in cement mortal 1:4 (1 cement :4 coase sand) Base foundation concrete in 1:4:8 mix (1 cement :4 sand :8 graded stone aggregate 40 mm normal size) inside & top plastering of wall with 12 mm thick with cement mortal 1:3 ( 1 cement and including precast removable type RCC slab with 1:2:4(1 cement :2soarse sand and 4 gradedstone aggregate of 20 mm size) Including centering shuttering excvation refilling and disposal of surplus earth as directed all complete in all respect as per drawing and design as per direction by the E/Ic (as per approved desig) - PSR

50

-

5578



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.