Kanpur Electricity Supply Company Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Kanpur Electricity Supply Company Limited - KESCO Tender
Eprocure
Opening Date14 Jul 2020
Closing Date10 Aug 2020
Tender Amount₹ 8,93,798 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 10,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_KESCO_492910_1Bid Award Id
ViewTender No
18/Const./2020-21Tender Authority
Kanpur Electricity Supply Company Limited ViewPurchaser Address
-Website
http://https://kesco.co.in/wss/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Loading, Carriage and unloading of poles from store to work site.
50
-
-
Loading, Carriage and unloading of damaged poles from work site to store.
50
-
-
Dismentalling of binding wire from insulators and loosening of the conductor on each pole then lowering down the conductor & rolling in to bundles.
160
-
-
Loading, carriage and unloading of conductor from store to work site and vice versa
160
-
-
Erection of Old/new Steel Tubular pole for H.T. O.H./ L.T. O.H. line and fitting of X-Arms/L.T. Brackets, insulators and other hardware fittings.
100
-
-
Dismentalling of Aerial Bunched Cable from L.T./H.T. O/H (damage) line.
100
-
-
Loading, carriage and unloading of Aearial Bunched Cable (HT/LT) from store to work site and vice versa.
100
-
-
Laying of Aerial Bunched Cable for Erection of L.T./HT O/H Line.
100
-
-
Mounting & Erection of single phase distribution box.
40
-
-
Mounting & Erection of three phase distribution box.
20
-
-
Opening and reconnection of consumer connections for shifted/replaced of pole.
40
-
-
Re-sagging of conductor, on old line after erection of pole, binding of conductor etc.
10
-
-
Earthing of supports/ metering cubical/ HTPB/ACB etc. as per standard specifications.
40
-
-
Erection of stud pole/fly stay and fixing of stay wire etc. for complete erection.
8
-
-
Fixing of stay rod and its erection by fitting of stay clamp. Stay wire and its proper binding and tightening etc.
40
-
-
Laying, stringing, tensioning and binding of Weasel conductor for H.T./L.T. O.H.
200
-
-
Laying, stringing, tensioning and binding of Dog conductor for H.T./L.T. O.H.
200
-
-
Fixing of guarding angle/guarding channel for laying of guarding
6
-
-
Laying, stringing, tensioning & final sagging of Earth wire/G.I. wire
500
-
-
Cross lacing of guarding by G.I. wire (approximate 5 lacing of each span)
4
-
-
Opening of H.T. Jumpers from the existing 3 Phase 3 Wire H.T. O.H. line for erection work.
20
-
-
Opening of L.T. Jumpers from the existing L.T. O.H. line for erection work.
20
-
-
Painting of Steel Tubular Poles after rubbing, cleaning with emery paper and coating one coat of redoxide on full length of pole and then two coat of Aluminum paint upto X-arm from top including cost of paint and redoxide paint used should be ISI mark Ist class enamel paint.
50
-
-
Making plinth of single pole of 400 mm dia, 600 mm height (200mm underground) with C.C. in ratio 1:4:8 of cements, stone ballast and coarse sand including cost of materials.
50
-
-
Making plinth of Double Pole structure in size of 450x2250x600mm (200mm depth underground) with C.C. ratio 1:4:8 of cement, stone ballast and coarse sand including cost of materials.
4
-
-
Increasing the pole length to Cross H.T./L.T. OH line by welding of M.S. pipe.
4
-
-
Fabrication and erection of Distribution T/F fencing of frame size 3x2.4 Mtr. including cost of M.S. Agnle size 40x40x5 and M.S. Flat size 35x5, fixing of welded steel wire fabric on steel frames by welding of 10 SWG wire fabric, including Painting of two coats of paint on iron based surfaces with ready mixed paint to give bus green shade including cleaning of oil & dust.
4
-
-
Taking out new/old cable from cable drum and then after transportation from store to work site or vice-versa.
-
-
-
H.T. Cable
60
-
-
L.T. Cable
40
-
-
Digging of cable trench in size of 30 cm wide and 60 to 90 Cm meter deep as per site requirement for laying of cable-
-
-
-
Normal Soil
20
-
-
Kharanja Road
20
-
-
Metallic Road
36
-
-
Laying of cable in the above digging, trench, covering with bricks, sand and back filling.
-
-
-
H.T. Cable
40
-
-
L.T. Cable
40
-
-
Laying of H. T. cable through Hume/C.I./MS. pipe in digged trench and back filling.
-
-
-
H.T. Cable
16
-
-
L.T. Cable
16
-
-
Taking out (old & used) H.T. cable by digging of trench from site and then rolling in to bundles.
-
-
-
H.T. Cable
40
-
-
L.T. Cable
40
-
-
Laying, stringing, tensioning & final sagging of 11 kV XLPE Cable (Size 3x50 to 3x300 Sq.mm) pole to pole as O/H line.
40
-
-
Construction of T/F plinth, suitable for mounting of distribution transformer. Size of the plinth will be 1.2 x 1.2 x 1.2 meter solid with brick work. 75 mm thick C.C. in ratio 1:4:8 with cement, coarse sand and brick ballast laid on the base and 75 mm thick done on all the exposed sides to the plinth.
2
-
-
Laying of Cable through trench less method
20
-
-
Restoration of Metallic/RCC road after proper repairing with appropriate materials.
20
-
-
Making of HT AB Cable box/cable box for 11/6.6 kV 3x50 to 3x300 mm2 for XLPE/PILLCA cable (Jointing kit will be provided by Kesco.)
2
-
-
Mounting of HT AB Cable box/cable box on pole as well as on H.T.P.B./Outdoor Metering Cubical/H.T.M.C. the work includes proper clamping of cable box on both ends.
-
-
-
With pipe (3Mtr. Long MS pipe will be provided by KESCo)
2
-
-
Without pipe
2
-
-
Making Plinth for H.T.P.B./A.C.B. By brick work in size of 1.2x1 .2x1.0 meter for HTPB and as per requirement for ACB as well as plastering of 12 mm thick on all the exposed sides of the plinth.
2
-
-
Loading, Carriage and unloading of H.T.P.B./ACB form store to work site and then after erection on the relay constructed plinth.
2
-
-
Making Plinth for L.T. P.B. By brick work in size of 1.2x0.75x1.0 meter as well as plastering of 12mm thick on all the exposed sides of the plinth.
2
-
-
Loading, Carriage and unloading of L.T.P.B. form store to work site and then after erection on the relay constructed plinth.
2
-
-
Construction of plinth for H.T. pilfer metering cubical.
2
-
-
Loading, carriage and unloading of H.T.M.C. from store to site or vice-versa.
2
-
-
Erection of H.T. metering cubical/ACB on plinth as per standard norms.
2
-
-
Dismentalling of H.T. pilfer metering cubical/ACB
2
-
-
Erection of L.T. metering cubical as per standard norms and connection of L.T. Cable including crimping of Lugs etc.
2
-
-
Grouting of pole with cement brick ballast and coarse sand as per Standard Specification.
20
-
-
Erection of double pole structure including fixing of T.P.M.O. (if available) top channel, fuse set on fuse set channel etc. as per standard specifications.
4
-
-
Making of a double pole structure by erection a single pole with a specific distance from existing single pole on a running H.T. Line, fixing of T.P.M.O. (if available) (Top channel, fuse set channel etc. as per standard specification)
4
-
-
Painting of double pole structure with one coat of red oxide and two coats of Alm. Paint above fuse set including cost of Ist Class enamel paint.
4
-
-
Erection of Tri-Pole structure including fitting of channels etc. and proper alignment.
2
-
-
Painting of Tri-Pole structure with one coat of red oxide and two coats of Alm. Paint from X-arm to above including cost of Ist Class enamel paint.
2
-
-
Erection of four pole structure including fitting of channels etc. as well as proper alignment of structure.
2
-
-
Painting of four pole structure with one coat of red oxide and two coats of Alm. Paint from X-arm to above including cost of Ist Class enamel paint.
2
-
-
Distribution T/F work
-
-
-
Loading, carriage & unloading of distribution Transformers (Up to 630 kVA.) from store to site & vise-versa.
4
-
-
Erection of Distribution T/F on plinth/D/pole structure.
4
-
-
Connection of H.T. Jumper from fuse set to H.T. Bushing of the transformer.
4
-
-
Fitting of L.T. D.B./A.C. Breakers by brackets & clamps on double pole structure & L.T. Cable Connection from T/F Cable to L.T.D.B.
4
-
-
Connection of L.T. cable from L.T.D.B/ A.C. Breakers to L.T.O.H.
4
-
-
Erection of O/D type Metering unit :-
-
-
-
Loading, carriage & unloading of O/D type metering unit from store to site & vice-versa.
2
-
-
Erection of O/D type Metering unit on D/P Structure.
2
-
-
Connection of H.T. Jumper to HT Bushing of O/D type Metering unit.
2
-
-
Making of H.T. Section points by brackets, clamps & Insulator, tightening of Line, binding of conductor & proper connection.
4
-
-
Making of L.T. Shackle point by brackets, clamps, G.I. Shakle strips and insulators, tightening of line, binding of conductors and proper connections.
4
-
-
Disconnection of H.T./L.T. Lines, Shifting of T/F from ground to a safe place for construction of T/F plinth.
4
-
-
Shifting of T/F from ground to plinth and re-connection of H.T. L.T. Lines as well as earthing for proper completion.
4
-
-
Cutting of tree branches for normal clearance of H.T. as well as L.T.O.H. Lines.
16
-
-
Fabrication/modifications of M.S. Items as per requirement of site conditions.
80
-
-
Jumpering of H.T. Lines from the existing H.T.O.H. line.
30
-
-
Jumpering of L.T. Lines from the existing L.T.O.H. line.
30
-
-
Stringing of H.T./L.T. Cable in different sizes as same as H.T./L.T. overhead line :
-
-
-
Single Core L.T. Cable
40
-
-
3 ½ Core L.T. Cable
40
-
-
11 kV H.T. Cable
40
-
-
Supply of 40mm dia Class 'B' G.I. Pipe 40' long including M.S. flat 50x6 mm along with all related materials required for distribution T/F earthing work.
4
-
-
Boring 39' deep & connection of neutral bushing with G.I. Pipe through M.S. flat/earth wire with proper connection arrangement.
4
-
-
Providing of one jeep gang with T & P on duty on special accessories.
3
-
-
Providing one pedal gang with T & P on duty on special accessories.
3
-
-
Digging by JCB for making straight through joint.
2
-
-