Kanpur Electricity Supply Company Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Kanpur Electricity Supply Company Limited - KESCO Tender

Works
Civil And Construction
Eprocure
Opening Date31 Jul 2020
Closing Date18 Aug 2020
Tender Amount₹ 8,23,495 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Repairing of damaged S.T. Pole by providing M.S. Angle 50x50x6mm, 3 Nos. each of 1 meter long by clamping at 2 points and its welding including its all related work.

2

-

-

... More
Erection of old/new S.T. Pole size 9.0 Mtr. to 13.00 Mtr. including digging of Pit back filling and ramming.

2

-

-

... More
Dismentalling of damaged S.T. Pole of very critical position with the help of crane after removing all the accessories from damaged pole and its all related work including digging of pit or by cutting with gas cutter.

3

-

-

... More
Mounting of New/old H.T./L.T. X-arm/bracket on the pole/rail.

12

-

-

... More
Dismounting of 33KV/11KV pin insulator and G.I. Pin on the pole after opening of binding.

12

-

-

... More
Repairing of 33/11KV damaged X-arm and proper shaping including drilling of holes whatsoever is required with the help of gas healing and welding.

6

-

-

... More
Laying, stringing, tensioning & binding ACSR dog conductor for 3Ø 3 wire 33KV O.H. line.

4

-

-

... More
Resagging of conductor on old/new line after replacement of damaged pole/erection of new pole and all related work.

3

-

-

... More
Dismounting of damaged disc insulator of disc insulator string after replacement of damaged insulators including, removing of conductor from disc fitting.

6

-

-

... More
Mounting of 33/11KV Pin insulator with G.I. Pin including binding of conductor with insulator.

6

-

-

... More
Fixing and grouting of stay rod including digging of pit, binding of stay wire and its all related work including cost of cement.

6

-

-

... More
Dismentalling of Aearail Bunched Cable from L.T./H.T. O.H. (damaged) line.

50

-

-

... More
Loading, Carriage and unloading of Aearial Bunched Cable (HT/LT) from store to work site and vice-versa.

50

-

-

... More
Laying of Aearial Bunched Cable for Erection of L.T./H.T. O/H Line.

50

-

-

... More
Mounting and erection of Single Phase Distribution box.

20

-

-

... More
Mounting and erection of Three Phase Distribution box.

10

-

-

... More
Opening and reconnection of consumer connection for shifted/replaced of pole.

20

-

-

... More
Fixing of angle/guarding channel on S.T. Pole/Rail Pole for laying of guarding.

6

-

-

... More
Laying, Stringing, tensioning and final sagging of Earth Wire/G.I. wire.

200

-

-

... More
Cross lacing of guarding by G.I. wire (approximate 5 lacing of each span)

4

-

-

... More
Fabrication and erection of Distribution T/F fencing of frame size 3x2.4 Mtr. including cost of M.S. Angle size 40x40x5 and M.S. Flat size 35x5, fixing of welded steel wire fabric on steel frames by welding of 10 SWG wire fabric, including Painting of two coats of paint on iron based surfaces with ready mixed paint to give bus green shade including cleaning of oil & dust.

28.8

-

-

... More
Taking out new/old cable from cable drum and then after transportation from store to work site or vice-versa.

-

-

-

... More
H.T. Cable

40

-

-

... More
L.T. Cable

20

-

-

... More
A.B. Cable of different size.

50

-

-

... More
Digging of cable trench in size of 30 cm wide and 60 to 90 Cm meter deep as per site requirement for laying of cable-

-

-

-

... More
Normal Soil

10

-

-

... More
Kharanja Road

10

-

-

... More
Metallic Road

18

-

-

... More
Tiles Road

10

-

-

... More
Laying of cable in the above digging, trench, covering with bricks, sand and back filling.

-

-

-

... More
H.T. Cable

40

-

-

... More
L.T. Cable

40

-

-

... More
Laying of H. T. cable through Hume/C.I./MS. pipe in digged trench and back filling.

-

-

-

... More
H.T. Cable

16

-

-

... More
L.T. Cable

16

-

-

... More
Taking out (old & used) H.T. cable by digging of trench from site and then rolling in to bundles.

-

-

-

... More
H.T. Cable

20

-

-

... More
L.T. Cable

20

-

-

... More
Laying, stringing, tensioning & final sagging of 33 KV/11 KV XLPE Cable (Size 3x50 to 3x300 Sq.mm) pole to pole as O/H line.

20

-

-

... More
Laying of Cable through trench less method (HDD) without HDPE Pipe

10

-

-

... More
Laying of L.T. Cable through moling method.

10

-

-

... More
Restoration of Metallic/RCC road after proper repairing with appropriate materials.

10

-

-

... More
Making of HT AB Cable box/cable box for 33 KV/11 3x50 to 3x300 mm2 for XLPE/PILCA cable (Jointing kit will be provided by Kesco.)

2

-

-

... More
Mounting of 11 KV HT AB Cable box/ 33 KV/11 KV cable box on pole as well as on H.T.P.B./Outdoor Metering Cubical/H.T.M.C. the work includes proper clamping of cable box on both ends.

-

-

-

... More
Without pipe

2

-

-

... More
Making Plinth for H.T.P.B. By brick work in size of 1.2x1 .2x1.0 meter as well as plastering of 12 mm thick on all the exposed sides of the plinth.

2

-

-

... More
Loading, Carriage and unloading of H.T.P.B. form store to work site and then after erection on the relay constructed plinth.

2

-

-

... More
Providing and erection of HTPB/LTPB and making its plinth by brick work size 1.2x1.2x1 Mtr including 11 mm thick plastering on all exposed sides of the plinth.

2

-

-

... More
Making Plinth for L.T. P.B. By brick work in size of 1.2x0.75x1.0 meter as well as plastering of 12mm thick on all the exposed sides of the plinth.

2

-

-

... More
Distribution T/F work

-

-

-

... More
Loading, carriage & unloading of distribution Transformers (Up to 630 K.V.A.) from store to site & vise-versa.

3

-

-

... More
Erection of Distribution T/F on plinth/D/pole structure.

3

-

-

... More
Connection of H.T. Jumper from fuse set to H.T. Busing of the transformer.

3

-

-

... More
Fitting of L.T. D.B. by brackets & clamps on double pole structure & L.T. Cable Connection from T/F bushing to L.T.D.B.

2

-

-

... More
Connection of L.T. cable from L.T.D.B to L.T.O.H.

4

-

-

... More
Erection of O/D type Metering unit :-

-

-

-

... More
Loading, carriage & unloading of O/D type metering unit from store to site & vice-versa.

2

-

-

... More
Erection of O/D type Metering unit on D/P Structure.

2

-

-

... More
Connection of H.T. Jumper to HT Bushing of O/D type Metering unit.

2

-

-

... More
Making of 11 KV H.T. Section points by brackets, clamps & Insulator, tightening of Line, binding of conductor & proper connection.

4

-

-

... More
Disconnection of H.T./L.T. Lines, Shifting of T/F from ground to a safe place for construction of T/F plinth.

4

-

-

... More
Shifting of T/F from ground to plinth and re-connection of H.T. L.T. Lines as well as earthing for proper completion.

4

-

-

... More
Stringing of H.T./L.T. Cable in different sizes as same as H.T./L.T. overhead line :

-

-

-

... More
Single Core L.T. Cable

20

-

-

... More
3 ½ Core L.T. Cable

20

-

-

... More
11 KV H.T. Cable

20

-

-

... More
Supply of 40mm dia Class 'B' G.I. Pipe 40' long including M.S. flat 50x6 mm along with all related materials required for distribution T/F earthing work.

2

-

-

... More
Boring 39' deep & connection of neutral bushing with G.I. Pipe through M.S. flat/earth wire with proper connection arrangement.

2

-

-

... More
Providing of one jeep gang with T & P on duty on special accessories.

3

-

-

... More
Providing one pedal gang with T & P on duty on special accessories.

3

-

-

... More
Construction of T/F plinth, suitable for mounting of distribution transformer. Size of the plinth will be 1.2 x 1.2 x 1.2 meter solid with brick work. 75 mm thick C.C. in ratio 1:4:8 with cement, coarse sand and brick ballast laid on the base and 75 mm thick done on all the exposed sides to the plinth.

3.46

-

-

... More
Dismentalling of 11 KV TPMO from existing Double pole.

2

-

-

... More
Erection of 11 KV TPMO on Double pole.

2

-

-

... More
Attending L.T. defective Air Circuit Breaker to make it functional by making adjustment in alignment or by replacing defective MCCB (MCCB will be provided by Kesco.).

5

-

-

... More
Attending defective L.T. A Panel/B Panel of under ground cable network either by making proper adjustment or replacing defective part other than MCCB.

5

-

-

... More
Earthing of support by sagging of M.S. earthing rod 20mm and connecting with earth wire and related work.

6

-

-

... More
Laying of control cable including digging of trench and back filling.

100

-

-

... More
Dismentalling of damaged 33 KV O/D Type C.T./P.T. from structure, dismentalling of wiring and earthing and its all related work.

4

-

-

... More
Mounting of 33KV O/D Type C.T./P.T. on erected structure in proper position its wiring and earthing and its all related work.

4

-

-

... More
Dismentalling of damaged 33KV lighting arrestors from structure and its all related work as opening of clamps etc.

4

-

-

... More
Mounting of 33KV lighting arrestor on erected structure including its re-fabrication for matching holes, mounting in proper alignment itsearthing and its all related work as connecting to lower bus-bar.

4

-

-

... More
Fabrication of earth electrode from 36mm/40mm M.S. Round bars 3 meter long making one end pointed upto 15cm. including cutting of round bar.

8

-

-

... More
Erection of earth electrode 36mm/40mm by making pit of size 2’x2’ then pegging the earth electrodes with filling the pit with water and hammering the electrodes by hammer upto 0.5 meter proper below ground level.

4

-

-

... More
Earhting of yard/structure/S/G with M.S. Flat 50x6mm connecting with main Mate/Risers/Earth electrodes after its bending shaping and welding the strip including cost of M.S. Flat.

40

-

-

... More
Chopping of tree branches lying in the route of existing line touching the tree branches to the phase line conductor making fault to the feeder, for 3” to 18” dia or as per requirement of site.

20

-

-

... More
Carriage of following stock materials from store to site of work as and when required or back to store from site (Old and damaged material):-

-

-

-

... More
S.T. Pole 9.0 meter to 13.00 meter.

10

-

-

... More
M.S. Rail 10.0 Mtrs. To 13.0mtr.

2

-

-

... More
33KV Lighting arrestors

2

-

-

... More
33KV C.T./P.T. Outdoor Type

2

-

-

... More
33KV Isolator

2

-

-

... More
33KV Metering Cubical

2

-

-

... More
11KV Switchgear Panel

2

-

-

... More
33KV M.O.C.B/V.C.B./I.D. Panel

2

-

-

... More
33KV Control Relay Panel

2

-

-

... More
Repairing of 33 KV Old Isolator by replacing the jaws and blades or by oiling and greasing of moving parts or by adjustment of moving mechanism or by leveling the whichever is required for smooth operation of isolator and its all related work.

1

-

-

... More
Dismentalling of old and damaged 33KV Isolator from structure by cutting the old bolts and nuts and removing all mechanism with the help of Gas Cutter. It includes removing of jumpers with Isolator clamps and all related work.

1

-

-

... More
Erection of 33KV Isolator on erected Isolator structure in proper alignment fitting its complete moving mechanism its proper adjustment, leveling and oiling, greasing including cost of nuts and bolts what so ever required including any type of fabrication required for the work.

1

-

-

... More
Dismentalling of old & damaged lower bus bar of Dog/Panther conductor, dismentalling of clamps connectors from all concerning equipment

1

-

-

... More
Dismentalling of old & damaged upper of ACSR Dog/Panther Conductor, Dismentalling of Disc Insulator string.

1

-

-

... More
Fabrication of Busbar Gantry.

1

-

-

... More
Erection & Grouting of Busbar Gantry.

1

-

-

... More
Shifting of 11KV S/G New/Damaged Panels/Control relay panel from unloading point to C/R or C/R to loading point.

2

-

-

... More
Erection of New/Old 11KV switchgear panel in control room building in proper alignment, grouting of Anchor bolts matching of switchgear with each other matching of bus bar and related work and its earthing including cost of cement and M.S. Flat.

2

-

-

... More
Shifting of 33KV S/G Panel from unloading to C/R building at place of erection or place of erection to loading point.

2

-

-

... More
Erection of new (Old 33KV) Indoor S/G Panel in control room building in proper alignment, grouting of Anchor Bolts, matching of base channel holes of switchgear and its all related work as grouting of panel and its earthing. It includes cost of cement and M.S. Flat.

2

-

-

... More
Dismentalling of old/damaged existing 33KV S/G Panel including opening of internal connection.

2

-

-

... More
Providing and fixing of flexible copper bond 30mm vide 30cm long and connecting with neutral support structure to T/F neutral bushing and proper tightening

2

-

-

... More
Erection of new lower bus-bar with ACSR Dog/Panther conductor from T/F 33KV Terminal to upper bus-bar connecting with all intermediate equipment and its all related work.

1

-

-

... More
Dismentalling of old/damaged existing 11KV S/G Panel including opening of inter connection.

2

-

-

... More
Making of 33KV M.O.C.B./V.C.B. plinth in size of 1.5x2.4x1.0 meter with brick work cement, sand ratio 1:6 making proper pockets for anchor bolts grouting its plastering around with smooth finish including cost of cement.

1

-

-

... More
Erection of new Upper Busbar with ACSR Dog/Panther Conductor including mounting of disc insulator string.

1

-

-

... More
Shifting of 33KV M.O.C.B./V.C.B./M.C.B. from unloading point to place of erection of 33KV switch yard and dismentalling of its wooden packing of shifting of damaged equipment's as above from plinth to loading point.

1

-

-

... More
Erection and grouting of 33KV MOCB/VCB structure on MOCB/VCB plinth in 1:2:4 ratio with stone ballast.

1

-

-

... More
Dismentalling of 33KV M.O.C.B./VCB from erected structure with the help of crane.

1

-

-

... More
Erection of 33KV M.O.C.B./VCB on erected structure with the help of crane in proper alignment and its all related work.

1

-

-

... More
Making all control cable connection in C.T., M.O.C.B./VCB mechanism, C.T. Junction Box, Transformer Control relay panel D.C. Battery Charger, ACDB Transformer indication board 11KV switchgear including proper termination ferruling and dressing with related work whichever is required.

1

-

-

... More
Erection of 33KV metering cubicle/33KV control Relay Panel in control room in proper alignment including its earthing and related work.

1

-

-

... More
Dismentalling of H.T./L.T. Jumpers from line to each phase.

8

-

-

... More
Taking out 33/11KV XLPE/PILCA cable from drum/complete drum of cable from store its loading carriage and safe unloading by truck/bullock cart at site of work or from site to store.

100

-

-

... More
Digging of suitable pit for making joint of cable for straight through joints and to manage the cable jointer for above joint with complete meggering and all related work and covering the bricks and backfilling. The jointing kit will be provided by Dept. size total 1.5x4 meter and 2 meter deep.

2

-

-

... More
Excavation of old H.T. cable from ground and carrying it upto Kesco Store.

20

-

-

... More
Dismentalling of connected cable box on pole/S/G Panel/Cable support structure.

4

-

-

... More
Mounting of cable box on pole, S/G panel cable support structure with handling of concerning cable and its proper fixing.

4

-

-

... More
Making jumpers from cable box to line, cable support switchgear panels, section poles of each phase.

10

-

-

... More
Painting of Steel Tubular Poles after rubbing, cleaning with emery paper and coating one coat of redoxide on full length of pole and then two coat of Aluminium paint upto X-arm from top including cost of paint and redoxide paint used should be ISI mark Ist class enamel paint.

2

-

-

... More
Making plinth of single pole of 400 mm dia, 600 mm height (200mm underground) with C.C. in ratio 1:4:8 of cements, stone ballast and coarse sand including cost of cement, stone & sand etc.

2

-

-

... More
Grouting of pole with cement brick ballast and coarse sand as per standard specifications.

2

-

-

... More
Digging of cable trench for taking out old/damaged XLPE/PILCA, 3x50 to 3x300sqmm 33/11KV cable & taking out the above Cable from digged trench and back filling of digged trench.

20

-

-

... More
Fabrication of following structure with M.S. Channel, M.S. Angle, M.S. Flat etc. in required size & length including cutting drilling, holes, welding and assembling.

-

-

-

... More
Cable Support Structure

2

-

-

... More
Neutral Support Structure

2

-

-

... More
Fuse Set Unit

2

-

-

... More
Erection and grouting of following structure with 1:4:8 C.C. 25mm brick ballast in required size as proper alignment and making plinth of all structure in 1:2:4 CC mix with 20mm stone grit, 15cm above ground level to smooth finish and proper curing including cost of cement.

-

-

-

... More
Cable Support Structure

2

-

-

... More
Neutral Support Structure

2

-

-

... More
Fuse Set Unit

2

-

-

... More
Unloading of following power T/F main tank filled with oil, along with its all accessories like radiators, conservator tank T/F oil vent pipe etc. from Truck by crane and proper stacking.

-

-

-

... More
10/8/6 MVA, 33/11/6.6 KV T/F

2

-

-

... More
5/3/1.5 MVA, 33/11/6.6 KV T/F

2

-

-

... More
Dismentalling of following power T/F including draining of T/F oil from radiators if necessary dismentalling of all accessories, as Radiators, vent pipe conservator Tank from main Tank of T/F (Either one or all) and its proper stacking.

-

-

-

... More
10/8/6 MVA, 33/11/6.6 KV T/F

2

-

-

... More
5/4/3 MVA, 33/11/6.6 KV T/F

2

-

-

... More
Shifting of T/F Tank Empty/filled by dragging or by crane of following running/damaged T/F from unloading point to plinth of T/F or from T/F plinth to shifting/loading point distance upto 25 meters and its placing in proper alignment on plinth of Transformer.

-

-

-

... More
10/8/6 MVA, 33/11/6.6 KV T/F

2

-

-

... More
5/4 MVA, 33/11/6.6 KV T/F

2

-

-

... More
3/1.5 MVA, 33/11/6.6 KV T/F

2

-

-

... More
Loading carriage & unloading of main tank of T/F alongwith radiators &its all accessories & material of following T/F from store to site of work or worksite to store in between 20 Km. distance.

-

-

-

... More
10/8/6 MVA, 33/11/6.6 KV T/F

1

-

-

... More
5/4/3 MVA, 33/11/6.6 KV T/F

2

-

-

... More
10/8/6 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with no of two cranes and trolla.

1

-

-

... More
Erection of radiators, conservator tank vent pipe and all other accessories on main tank of following T/F including oil filling and all related work.

-

-

-

... More
10/8/6 MVA, 33/11/6.6 KV T/F

4

-

-

... More
5/4/3 MVA, 33/11/6.6 KV T/F

4

-

-

... More
Dismentalling of earthing of running/damaged transformer at two points with the help of gas cutter.

6

-

-

... More
Dismentalling and taking out the cable support structure by cutting with gas cutter for shifting of T/F including cutting of earthing of cable support structure wherever is required including its all related work.

6

-

-

... More
Dismentalling and taking out the neutral support structure by cutting with gas cutter alongwith removing of flexible copper bond and its proper stacking.

6

-

-

... More
Erection and welding of cable support structure with the help of welding including earthing of support in proper alignment and all related work.

4

-

-

... More
Erection & welding of neutral support structure with the help of welding including earthing in proper alignment and all related work and fixing of flexible copper bond.

6

-

-

... More
Earthing of T/F at two points by extending the existing M.S. Flat with main earthmate by welding.

6

-

-

... More
Fabrication of neutral support structure with M.S. Angle and M.S. Flat.

4

-

-

... More
Erection and grouting of neutral support structure with 1 : 4 : 8 CC ratio in proper alignment and plinth 15 Cm. above ground level and smooth finish.

4

-

-

... More
Disconnecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.

6

-

-

... More
Connecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.

6

-

-

... More
Fabrication of isolator structure as per standard design.

2

-

-

... More
Erection and grouting of Isolator structure in proper alignment and making plinth 15 Cm. above ground level with smooth finish.

2

-

-

... More
Construction of power T/F plinth suitable for 5/10 MVA 33 KV T/F in size of 3 x 3 x 1.5 Mtr. Digging of pit in size of 3.5 x 3.5 x 1.2 Mtr. Of CC work at bottom in size of 3.5 x 3.5 x .15 Mtr. With ratio of 1:4:8 its proper ramming and curing thereafter brick work in size of 3 x 3 x 0.8 Mtr. with 1 : 6 CC Sand ratio, thereafter CC work on top in size of 3 x 3 x .25 Mtr. thereafter plastering all around the open portion, grouting of rail and M.S. Angle in top CC work and its proper curing.

1

-

-

... More
T/F Flexible copper bond 30mm vide 30 Cm long & connecting with neutral support to T/F neutral bushing & proper tightening.

2

-

-

... More
Providing of one jeep gang with T.& P on duty on special accessories.

2

-

-

... More
Providing one padel gang with T.& P on duty on special accessories.

2

-

-

... More
Loading carriage & unloading of Rail Pole Pcs. 3 Mtr. long from store to site for power Transformer.

2

-

-

... More
Fitting of 3 Mtr. long Rail Pole on plinth under Power Transformer base.

2

-

-

... More
Dismentalling, erection of Switch yard fencing, civil work such as mounting and dismounting of Piller, Ten set and others

1

-

-

... More
Transportation charges of centrifuging machine to and fro for execution of work.

1

-

-

... More
Transportation charges of T/F oil from store to site.

500

-

-

... More
Erection of Double Pole Structure by digging of Pit.

2

-

-

... More
Providing of copper bus bar for making L for T/F bushing and fabrication & fitting of L connection and related work.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.