Kanpur Electricity Supply Company Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Kanpur Electricity Supply Company Limited - KESCO Tender

Goods
Civil And Construction
Road Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Oct 2024
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Rdss Modernization System Augmentation Work

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 33/11 kV outdoor 20 MVA ONAF Power Transformer with OLTC, RTCC panel & other standard accessories as per technical specifications and relevant IS.

6

-

-

... More
33 kV Switchgear

-

-

-

... More
Supply of 33 kV GIS Panels with 2 line bays, 2 transformer bays, one bus coupler bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control including PT raiser panel, any other equipment required for commissioning.

1

-

-

... More
Supply of 30 kV, 1-Phase, 10 kA Lightning Arrestor for GIS with all accessories as per TS

6

-

-

... More
Supply of 36 kV 1250 A Outdooor Vacuum Circuit Breaker confirming to IEC 62271-100, IEC 62271-200 with breaking capacity of 25 kA for 3s and making capacity of 62.5 kA with all required mounting structure and standard accessories along with CT structure.

49

-

-

... More
Supply of 36 kV 1250 A Indoor Vacuum Circuit Breaker with CRP (Outgoing)

32

-

-

... More
Supply of 36 kV 1250 A Indoor Vacuum Circuit Breaker with CRP (Incomming)

28

-

-

... More
Supply of 36 kV 1250 A Indoor Vacuum Circuit Breaker Bus coupler with adopter panel/trunk chamber

14

-

-

... More
Supply of Control & Relay Panel for 33 kV Feeder with IEC 61850 SCADA protocol compatible & numerical O/C and E/F protection

12

-

-

... More
Supply of Control & Relay Panel for Double Power Transformer with IEC 61850 SCADA protocol compatible differential protection

9

-

-

... More
Supply of Control & Relay Panel for Single Power Transformer with IEC 61850 SCADA protocol compatible numerical differential protection

19

-

-

... More
Supply of 33 kV Gapless Metal Oxide outdoor Lightning Arrestor, 30 kV rms Arrestor Rating

281

-

-

... More
Supply of 33 kV Single Phase, Dead Tank Type Out Door Current Transformer (400/200/1-1 A) having 0.5 Accuracy Class confirming to IS:2705-1992 (Part I-IV)/IEC- 185, IEC-60044

98

-

-

... More
Supply of 33 kV Single Phase, Dead Tank Type Out Door Current Transformer (200/100/1-1-1 A) having 0.5 Accuracy Class confirming to IS:2705-1992 (Part I-IV)/IEC- 185, IEC-60044.

139

-

-

... More
Supply of 33 kV /110V Single Phase, Dead Tank Type Out Door Oil Cooled Potential Transformer confirming to IS 3156

160

-

-

... More
Supply of outdoor type 33 kV, 3-phase, triple pole, double break, gang operated, centre rotating 800 A Line isolators on double rod turn & twisting system confirming to S: 9921(Part I to V) & IEC Publication No. 129

12

-

-

... More
Supply of outdoor type 33 kV, 3-phase, triple pole, double break, gang operated, centre rotating 800 A Bus isolators on double rod turn & twisting system confirming to IS: 9921(Part I to V) & IEC Publication No. 129

18

-

-

... More
Supply of 33 kV 400Amp D.O. fuse set along with channel & clamps

23

-

-

... More
Supply of outdoor type 33 kV, 3-phase, triple pole, double break, gang operated, centre rotating 800 A Line isolators for Mid Line Four Pole Structures

46

-

-

... More
11 kV Switchgear

-

-

-

... More
Supply of 11 kV GIS Panels with 6 line bays, 2 transformer bays, 1 station transformer bay & one bus coupler bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel, any other material required for commissioning. (SCADA Compatible & 61850 protocol compliant protection relays)

1

-

-

... More
Supply of 12 kV, 350 MVA, 1600 A, 25 kA Incommer Panel VCB (600-300/1-5-5A Three Core CT) (SCADA Compatible & 61850 protocol compliant protection relays)

23

-

-

... More
Supply of 12 kV, 350 MVA, 1600 A, 25 kA Incommer Panel VCB (800-400/1-5-5A Three Core CT) (SCADA Compatible & 61850 protocol compliant protection relays)

6

-

-

... More
Supply of 12 kV, 350 MVA, 1600 A, 25 kA Outgoing Panel VCB (400-200/5-5A Two Core CT) with same make Vacuum Interrupter. (SCADA Compatible & 61850 protocol compliant protection relays)

155

-

-

... More
Supply of 12 kV, 350 MVA, 1600 A, 25 kA Outgoing Bus-coupler Panel VCB (400-200/5-5A Two Core CT) with same make Vacuum Interrupter. (SCADA Compatible & 61850 protocol compliant protection relays)

18

-

-

... More
Supply of adapter panels for inter-connection of Bus Bar of 11 kV VCBs of different designs

30

-

-

... More
Supply of 11 kV 100 Amp D.O. fuse set along with channel & clamps

715

-

-

... More
Supply of outdoor type 11 kV, 3-phase, triple pole, double break, gang operated, centre rotating 400 A Line isolators (To be mounted on Pole) on double rod turn & twisting system along with GI Pipe and handle confirming to relevant IS

30

-

-

... More
Supply of 9 kV, 1-Phase, 10 kA Lightning Arrestor for GIS with all accessories as per TS

18

-

-

... More
Power Cables

-

-

-

... More
Supply of 19/33 kV 3Cx400 sq. mm XLPE Cable

124.16

-

-

... More
Supply of 19/33 kV 3Cx300 sq. mm XLPE Cable

0.96

-

-

... More
Supply of 33 kV 1Cx400 sq. mm XLPE Cable

1

-

-

... More
Supply of 6.6/11 kV 3Cx300 sq. mm XLPE Cable

34.41

-

-

... More
Supply of 6.6/11 kV 3Cx185 sq. mm XLPE Cable

0.96

-

-

... More
Supply of 6.6/11 kV 3Cx70 sq. mm XLPE Cable

7.22

-

-

... More
Heat Shrinkable Joints

-

-

-

... More
Supply of Heat Shrinkable Indoor Cable Termination Kit for 11 kV 3Cx300 sq.mm. cable

393

-

-

... More
Supply of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV 3Cx300 sq.mm. cable

489

-

-

... More
Supply of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV 3Cx185 sq.mm. cable

24

-

-

... More
Supply of Heat Shrinkable Indoor Cable Termination Kit for 33 kV 3Cx400 sq.mm. cable

8

-

-

... More
Supply of Heat Shrinkable Outdoor Cable Termination Kit for 33 kV 3Cx400 sq.mm. cable

392

-

-

... More
Supply of Heat Shrinkable Outdoor Cable Termination Kit for 33 kV 3Cx300 sq.mm. cable

24

-

-

... More
Supply of Heat Shrinkable Indoor Cable Termination Kit for 11 kV 3Cx70 sq.mm. cable

56

-

-

... More
Supply of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV 3Cx70 sq.mm. cable

1474

-

-

... More
Supply of Heat Shrinkable Straight through Jointing Kit for 33 KV XLPE 3x400 sqmm

100

-

-

... More
Supply of Heat Shrinkable Straight through Jointing Kit for 11 KV XLPE 3x300 sqmm

9

-

-

-

-

-

... More
Supply of 13 m long Steel Tubular Poles with welded steel base plate and of designation 410 SP-71 (IS 2713 Pt I, II, III) and Bottom Galvanised as per IS 2629 (1985)

1970

-

-

... More
Supply of 11 m long Steel Tubular Poles Bottom Galvinized with welded steel base plate and of designation 410 SP-55 (IS 2713 Pt I, II, III) and Bottom Galvanised as per IS 2629 (1985)

4973

-

-

... More
Supply of 9.5 m long Steel Tubular Poles with welded steel base plate and of designation 410 SP-37 (IS 2713 Pt I, II, III) and Bottom Galvanised as per IS 2629 (1985)

1266

-

-

... More
Supply of 9 m long PCC pole (M42 Concrete Grade)

7885

-

-

... More
Supply of Lattice M+4 Galvanized MS Tower Structure

26

-

-

... More
Supply of Hot Dipped Galvanized Rolled Joist Poles 152x152x 11.9 mm with Base Plate 7 m ( H-Beam/Joist Girder) and holes punched at required positions

60

-

-

... More
Supply of Hot Dipped Galvanized Rolled Joist Poles 152x152 x11.9 mm with Base Plate 4 m ( H-Beam/Joist Girder) and holes punched at required positions

1184

-

-

... More
Distribution Transformers & accessories

-

-

-

... More
Supply of 11/0.4 kV 63 kVA T/F with breather, conservators, arcing horns, attached MCCB with CRCA protective casing and other standard accessories

6

-

-

... More
Supply of 11/0.4 kV 250 kVA T/F with breather, conservators, arcing horns, attached MCCB with CRCA protective casing and other standard accessories

385

-

-

... More
Supply of 11/0.4 kV 400 kVA T/F with breather, conservators, arcing horns, attached MCCB with CRCA protective casing and other standard accessories

50

-

-

... More
Supply of 11/0.4 kV 250 kVA T/F with breather, conservators, arcing horns and other standard accessories

381

-

-

... More
Supply of 11/0.4 kV 400 kVA T/F with breather, conservators, arcing horns and other standard accessories

50

-

-

... More
Supply of 11/0.4 kV 400 kVA Compact Sub-Station with inbuilt HT/LT protection and all standard accessories

25

-

-

... More
Supply of Bushing boots for distribution transformer

2145

-

-

... More
Supply of T/F fencing of frame size 3x2.4 mtr. with gate and latch(size of fencing may vary as per site conditions) including cost of M.S. Angle size 40x40x5 and M.S. Flat size 50x6, fixing of welded steel wire fabric on steel frames by welding of 10 SWG wire fabric, including Painting of two coats of paint on iron based surfaces with ready mixed paint to give bus green shade including cleaning of oil and dust. Additional MS Strips 40x5 sqmm having height same as that of fencing to be placed vertically on the steel wire fabric at a distance of 0.5 m from one another for additional reinforcement.

16385

-

-

... More
Supply of T/F fencing of frame size 3x2.4 mtr. with gate and latch(size of fencing may vary as per site conditions) including cost of M.S. Angle size 40x40x5 and M.S. Flat size 50x6 including Painting of two coats of paint on iron based surfaces with ready mixed paint to give bus green shade including cleaning of oil and dust. Additional MS Strips 40x5 sqmm having height same as that of fencing to be placed vertically on the steel wire fabric at a distance of 75 mm from one another for additional reinforcement.

7022

-

-

... More
Supply of GI cable tray for housing of LT & HT cables of size 300m wise x 1500m long

296

-

-

... More
Supply of L.T. circuit 500 V /500 A( Tail-Less Unit)

1632

-

-

... More
Conductors

-

-

-

... More
Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - ACSR Dog Conductor

905.02

-

-

... More
Supply of ACSR Panther Conductor

1.3

-

-

... More
Supply of AL59 ACS covered Dog conductor

516.45

-

-

... More
LT XLPE Cables

-

-

-

... More
Supply of 3.5 CX25 Sq mm. XLPE

0.3

-

-

... More
Supply of 3.5 CX240 Sq mm. XLPE Armoured cable

96

-

-

... More
Supply of 3.5 CX300 Sq mm. XLPE Armoured cable

183.2

-

-

... More
Supply of 3.5 CX120 Sq mm. XLPE Armoured cable

36.4

-

-

... More
Supply of 3.5Cx70 sq mm XLPE Armoured cable

50

-

-

... More
Supply of 1Cx400 Sqmm.XLPE

76.82

-

-

... More
Supply of 2Cx6 Sqmm.XLPE Armoured service cable

76.8

-

-

... More
Supply of 2Cx10 Sqmm.XLPE Armoured service cable

27.6

-

-

... More
Supply of 2Cx16 Sqmm.XLPE Armoured service cable for street light

192

-

-

... More
Supply of 4Cx16 Sqmm.XLPE Armoured service cable

67.2

-

-

... More
Supply of 4Cx25 Sqmm.XLPE Armoured service cable

96

-

-

... More
Supply of 1Cx25 Sqmm.XLPE

52.65

-

-

... More
Supply of LT Cable Ferrules for consumer identification, cable tracing, etc. per DT

96

-

-

... More
Supply of AERIAL BUNCHED XLPE CABLE 3x120+1x95+1x16 sqmm

360.15

-

-

... More
Supply of AERIAL BUNCHED XLPE CABLE 3x150+1x125+1x16 sqmm

375.9

-

-

... More
Control Cables

-

-

-

... More
Supply of Control Cable 2 Cx2.5 mm²

23.35

-

-

... More
Supply of Control Cable 4 Cx2.5 mm²

23.5

-

-

... More
Supply of Control Cable 6 Cx2.5 mm²

12.5

-

-

... More
Supply of Control Cable 10 Cx2.5 mm²

0.15

-

-

... More
Sub-Station Accessories

-

-

-

... More
Supply of CO2 cylinder 4 nos of 4.5 kgs supply and fixing of CO2 type fire extinguishers capacity confirming to IS 2878 made ISI mark (1 set)

12

-

-

... More
Supply of ISI make ABC Power MAP 2 kg Fire extinguisher Mono ammonium phosphate power 50, stored pressure type, complete with pressure guage and all accessories applicable on class A,B,C electrically started fler as per building SSR.

12

-

-

... More
Supply of Synthetic Rubber mats as per IS 15652 in control room 2.5 mm thick

33.94

-

-

... More
Supply of 24 V, 80AH, Ni-Cd sealed type battery set and all other accessories complete.

53

-

-

... More
Supply of Float-cum-boost battery charger (SMPS based ) with full wave, full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery along with DCDB, connectors, surge protection device, etc. complete and connection with 24 V, 80AH Battery set and single phase AC input supply.

6

-

-

... More
Supply of Float-cum-boost battery charger (SMPS based ) with full wave, full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery

46

-

-

... More
Supply of 415V AC Distribution Board/Panel of sheet steel enclosed cubical with surge protection device floor mounting type for catering auxiliary power supply of the substation etc.

6

-

-

... More
Supply of 415V AC Distribution Board/Panel of sheet steel enclosed cubical without surge protection device floor mounting type for catering auxiliary power supply of the substation etc.

65

-

-

... More
Supply of 24V DC Distribution Board/Panel of sheet steel enclosed cubical

65

-

-

... More
Supply of sand bucket stand with 6 Nos. buckets.

6

-

-

... More
Supply of CT /PT Junction box

158

-

-

... More
MS Items/Galvanized Items

-

-

-

... More
Supply of Pre-fabricated Galvanized steel items like V cross arm, top clamp, F/E Bracket, clamps, cross bracings,strain plate, guarding channels, back clamp, transformer mounting structure, Terminal gantry structute etc made of MS Channels (100x50x6mm), MS angle (65x65x6mm), M.S./G.I. Strip (50x6 mm),M.S. Strip (75x8 mm), any other MS material not inluded elsewhere. All materials shall be of the approved size duly galvanised for over head structures as per technical specification, approved drawings and scope of work. (Including required fabrication work, if any)

286.51

-

-

... More
Supply of Pre-fabricated Non-Galvanized steel items like MS Channel, MS angle , M.S./G.I. Strip (50x6 mm),M.S. Strip (75x8 mm), MS Rail Pole Non Galvanzied (For Power Transformer placement) MS Round(non-galvanized) of 40 mm dia and 3000 mm long, any other MS material not inluded elsewhere. All materials shall be of the approved size as per technical specification, approved drawings and scope of work. (Including required fabrication work, if any)

122.79

-

-

... More
Supply of MS Nuts, Bolts with Washers(duly galvanised) as per technical specification, approved drawings and scope of work (off size).

24.4

-

-

... More
Supply of GI Pipe for external area of small cable to houses(50mm dia)

9.6

-

-

... More
Supply of GI Pipe for external area of small cable to houses (40 mm dia)

48

-

-

... More
Supply of GI Pipe for cable riser(150 mm dia)

3.98

-

-

... More
Insulators

-

-

-

... More
Supply of 11 KV Disc Fitting B & S type (70 KN) for bearing weight of dog Conductor

6290

-

-

... More
Supply of Polymeric 11 KV Disc Insulators B&S type 70 KN.

6387

-

-

... More
Supply of Porcelain 11 KV Disc Insulators B&S type 70 KN.

5073

-

-

... More
Supply of 11 kV Polymer Pin Insulators 10 kN with GI pin

6414

-

-

... More
Supply of 11 kV Porcelain Pin Insulators 10 kN with GI pin

5100

-

-

... More
Supply of 33 kV Polymer Pin Insulator with GI pin

3139

-

-

... More
Supply of 33 kV Porcelain Pin Insulator with GI pin

3227

-

-

... More
Supply of 33 KV Disc Fitting B & S type (70 KN) for bearing weight of Panther Conductor

48

-

-

... More
Supply of Disc Fitting for Covered Conductor

2527

-

-

... More
Supply of Disc Insulators for covered conductors

5965

-

-

... More
Supply of HDPE Spacers for Covered Conductors

51

-

-

... More
Supply of LT Pin Insulator with GI pin

3480

-

-

... More
Supply of LT shackle insulator with shackle strip

1160

-

-

... More
Pole Accessories

-

-

-

... More
Supply of Dead End clamps with Eye-Hook and holding clamp required for STP/PCC pole(Insulated)

7010

-

-

... More
Supply of Suspension clamps with Eye-Hook and holding clamp required for STP/PCC pole(Insulated)

10515

-

-

... More
Supply of LT insulated Piercing Connectors of 25-150 sqmm size for energizing distribution Kiosk/box

9500

-

-

... More
Supply of LT insulation Piercing Connectors of 25-120 sqmm size for energizing distribution Kiosk/box

9000

-

-

... More
Supply of New Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 2 No turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.

8333

-

-

... More
Supply of Spike Earthing 2540mm long made of 20mm GI solid Rod.

18794

-

-

... More
Supply of Suitable 33 kV Brackets/Cross Arms with adequate insulating materials and any other minor accessories required for single M+4 Tower

26

-

-

... More
Supply of 8 SWG GI wire

34.16

-

-

... More
Supply of L.T. Neutral Bare Connector.

10800

-

-

... More
Supply of CI Packing (Galvanised) as per site requirement.

314

-

-

... More
Supply of Danger Plate

16192

-

-

... More
Supply of G.I. Barbed Wire

30.81

-

-

... More
Supply of stone pad 300x300mm for PCC pole

7885

-

-

... More
Distribution Boxes

-

-

-

... More
Single Phase CRCA MS Deep Drawn Distribution Box with clamps with and all accessories.

3505

-

-

... More
Three Phase CRCA MS Deep Drawn Distribution Box with clamps with lug and all accessories.

1752

-

-

... More
Supply of CRCA MS deep drawn junction box with 1500 mm long GI pipe 40 mm dia with clamp and MS Angle stand (for street light connection)

1200

-

-

... More
Supply of Single phase SMC distribution box with clamps.

3505

-

-

... More
Supply of Three phase SMC distribution box with clamps.

1752

-

-

... More
Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubicle should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 400 KVA (Type A-2) (Incomer - 1 set of 800 amp. ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 6 sets of 250 amp. TP MCCB with spreader & Extended handle (5No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle)

60

-

-

... More
Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2mm Sheet Steel & Provided with 2mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 250 KVA (Type A-3) (Incomer - 1 set of 630 amp. ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs)) (Outgoing - 5 sets of 250 amp. TP MCCB with spreader & Extended handle (4No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle)

20

-

-

... More
Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 160 KVA (Type A-4) (Incomer - 1 set of 400 amp. ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 4 sets of 250 amp. TP MCCB with spreader & Extended handle (3No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle)

16

-

-

... More
Supply of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 400 amp. Aluminum Bus bar (Type B-1) with (On/Off Indicating light) (Metering on Incomer- 2 set of Digital Ammeter with ASS) (2 set of Digital Voltmeter with VSS) (2 set of LED type Phase Indication light (22.5 MM) having : 2 no Incomer 250amp with changeover facility. 6 set of out-going 100 amp HRC fuse with suitable housing.

60

-

-

... More
Supply of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 300 amp. Aluminum Bus bar (Type B-2) with (On/Off Indicating light) (Metering on Incomer- 2 set of Digital Ammeter with ASS) (2 set of Digital Voltmeter with VSS) (2 set of LED type Phase Indication light (22.5 MM) having : 2 no Incomer 250amp with supply changeover & isolation facility. 5 set of out-going 100 amp HRC fuse with suitable housing.

280

-

-

... More
Supply of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 300 amp. Aluminum Bus bar (Type B-3) with (On/Off Indicating light) (Metering on Incomer- 2 set of Digital Ammeter with ASS) (2 set of Digital Voltmeter with VSS) (2 set of LED type Phase Indication light (22.5 MM) having : 2 no Incomer 250amp with supply changeover & isolation facility. 4 set of out-going 100 amp HRC fuse with suitable housing.

236

-

-

... More
Supply of lockable distribution box along with bar lock of size 450x450 mm including suitable foundation with bus bar amp. 140 TPN to feed up to 10 houses (Type C). Panel to be made of 2mm. CRCA sheet

3840

-

-

... More
Earthing

-

-

-

... More
Supply of GI Pipe 40 mm dia B-Class 20 feet Deep for earthing

9787

-

-

... More
Sectionalizers/Fault Passage Indicators

-

-

-

... More
33 kV FPI (Non-communicable) with all required mounting material

174

-

-

... More
11 kV FPI(Non-communicable) with all required mounting and commissioning material

947

-

-

... More
Supply of 11 kV ,400 A De-Linking Switch with required MS structure to be monunted on pole

1044

-

-

... More
11 kV Gang Operated Devices with required channel and other mounting material

1027

-

-

... More
Supply of Cable end termination using total double compression Brass glands and crimping type aluminum thimbles size for L.T. cables.

-

-

-

... More
3.5 CX300 Sq mm. XLPE

3648

-

-

... More
3.5 CX240 Sq mm. XLPE

2880

-

-

... More
3.5 CX120 Sq mm. XLPE

816

-

-

... More
3.5 CX70 Sq mm. XLPE

1104

-

-

... More
HDPE/PVC pipe

-

-

-

... More
Supply of HDPE pipe 120 mm dia to be laid by horizontal drilling for under ground piping (trenchless) at road cross of above cable.

14.4

-

-

... More
Supply of PVC pipe heavy gauge 40 mm dia (under ground area) pipe for small cable to houses

112.32

-

-

... More
Air Circuit Breakers

-

-

-

... More
Supply of LT ACB 630A on DTs with mounting structure

729

-

-

... More
Supply of LT ACB 800A on DTs having capacity greater than or equal to 400 KVA

1092

-

-

... More
33 KV GIS/AIS Bay

-

-

-

... More
Erection of 33 KV GIS bay by using standard equipments/ Material as per UPPTCL norms either by themself or by UPPTCL in accordance to Proforma invoice provided by them.

5

-

-

... More
Erection of 33 KV AIS bay by using standard equipments/ Material as per UPPTCL norms either by themself or by UPPTCL in accordance to Proforma invoice provided by them.

9

-

-

... More
Erection of 33/11 kV GIS S/S

-

-

-

... More
Construction of power T/F plinth suitable for 10 MVA 33/11kV T/F in size of 3.5 x 3.5 x 1.5 Mtr. by digging of pit in size of 4.0 x 4.0 x 1.2 Mtr. of CC work and at bottom in size of 4.0 x 4.0 x .15 Mtr. with ratio of 1:3:6, its proper ramming and curing thereafter brick work in size of 3.5 x 3.5 x 0.8 Mtr. with 1 : 4 CC Sand ratio, thereafter CC work on top in size of 3.5 x 3.5 x .25 Mtr. thereafter plastering all around the open portion, grouting of rail and M.S. Angle in top CC work and its proper curing. Reinforcement by mesh of Steel TMT Bar of size 12mm.

2

-

-

... More
Erection, testing and commissioning of 10 MVA, 33/11 kV power T/F along with radiators, conservator tank, vent pipe, RTCC panel in control room and all other accessories on main tank after placement of rail pole 3 m long including erection of required number of CT/PT junction box and oil filling and all other related work/supply required for succesful commissioning.

2

-

-

... More
Erection, testing and commissioning of 33 kV GIS Panels with 2 line bays, 2 transformer bays, one bus coupler bay, Bus PT, LA etc. all complete with numerical relays, facility for data transmission and remote control including PT raiser panel etc. and any other auxillary items required for commissioning along with supply if required.

1

-

-

... More
Erection, testing and commissioning of 11 kV GIS Panels with 6 line bays, 2 transformer bays, 1 station transformer bay & one bus coupler bay, Bus PT, LA,etc. all complete with numerical relays, facility for data transmission and remote control including PT raiser panel etc. and any other auxillary items required for commissioning along with supply if required.

1

-

-

... More
Erection of 24 V, 80AH, Ni-Cd sealed type battery set and all other accessories complete.

1

-

-

... More
Erection of Float-cum-boost battery charger (SMPS based ) with full wave, full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery alongwith DCDB, connectors, surge protection device, etc. complete and connection with 24 V, 80AH Battery set and single phase AC input supply.

1

-

-

... More
Erection of 415V AC Distribution Board/Panel of sheet steel enclosed cubical with surge protection device floor mounting type for catering auxiliary power supply of the substation,etc. including supply of wires and any other materials required.

1

-

-

... More
Erection, testing and commissioning of 63 kVA, 11 kV/0.415 kV Station Transformer along with all accessories such as DO Fuse, Bushing Boots, HT/LT side connections from S/S Panel and upto AC Distribution Box(excluding laying), etc. as per TS along with supply of copper L-Joints for LT Bushing and any other accessories required.

1

-

-

... More
Erection of switchyard earthing mat and near control room for 33 kV equipments for double transformers of GIS S/S and related switchyard equipments using MS Round Bar of 40 mm dia by pegging and driving it 50cm below ground level including all fabrication work erection of required no. of delta and connection of equipments with this mat using 75x8 MS strips.

1

-

-

... More
Erection of mounting structures for switchyard euipments, then mounting of equipments along with grouting, foundation plinth, painting etc and any other required work

1

-

-

... More
Construction of control cable trench by brick work, edges by 40x5 mm MS angle & plastering with trench cover having 40x5 mm MS Angle edges as per standard specifications.

50

-

-

... More
Laying of control cable for both transformers in switchyard and control room including ferruling, glanding and connections with the equipments

1

-

-

... More
Erection of Double Pole structures including grounting (1:3:6 CC mixture), foundation plinth (1:2:4 CC mixture), pole-painting along with fixing of channels, pin insulators, GI Pipe, danger board, barbed wire, earth wire, spike rod, stay set, etc.as per approved drawing and standard specification of UPPCL/RESSPO.

7

-

-

... More
Laying of 33 kV/11 kV/LT Cable including mounting on pole, MS structures, etc. by digging of trench at standard depth and using sand, bricks, etc as per approved drawing and standard specification of UPPCL/RESSPO.

1.85

-

-

... More
Erection, mounting and connection of heat shrinkable joints at poles, equipments, structures, etc.

50

-

-

... More
Erection and placement of fire extinguisher, sand buckets with stand, earth mat, etc at suitable locations

1

-

-

... More
Boring and lowering of Class-B 40 mm dia 20 feet long GI Pipe and connections with the power transformers(80 feet deep at 3 points and connection with MS Round Bar Delta) and other equipments(60 feet deep) as per standard practices including all necessary fabrication works and construction of 3 earth pits each for both power transformers

59

-

-

... More
Levelling of switchyard after back-filling of soil and using stone ballast for top surface including supply of all related materials

100

-

-

... More
Erection of 33/11 kV AIS S/S

-

-

-

... More
Construction of power T/F plinth suitable for 10/12.5 MVA 33/11kV T/F in size of 3.5 x 3.5 x 1.5 Mtr. by digging of pit in size of 4.0 x 4.0 x 1.2 Mtr. of CC work and at bottom in size of 4.0 x 4.0 x .15 Mtr. with ratio of 1:3:6, its proper ramming and curing thereafter brick work in size of 3.5 x 3.5 x 0.8 Mtr. with 1 : 4 CC Sand ratio, thereafter CC work on top in size of 3.5 x 3.5 x .25 Mtr. thereafter plastering all around the open portion, grouting of rail and M.S. Angle in top CC work and its proper curing. Reinforcement by mesh of Steel TMT Bar of size 12mm.

10

-

-

... More
Erection, testing and commissioning of 10/12.5 MVA, 33/11 kV power T/F along with radiators, conservator tank, vent pipe, RTCC panel in control room and all other accessories on main tank after placement of rail pole 3 m long including erection of required number of CT/PT junction box and oil filling and all other related work/supply required for succesful commissioning.

10

-

-

... More
Erection, testing and commissioning of 33 kV VCB and any other auxillary items required for commissioning along with supply if required including dissconneting and reconnecting of Existing earthing by extending and welding, painting MS Flat 50x6.

18

-

-

... More
Erection, testing and commissioning of 33 kV Feeder/ Single Transformer Control Relay Panel and any other auxillary items required for commissioning along with supply if required.

8

-

-

... More
Erection, testing and commissioning of 33 kV Double Transformer Control Relay Panel and any other auxillary items required for commissioning along with supply if required.

5

-

-

... More
Erection, testing and commissioning of 11 kV VCB(I/C,O/G and Bus Coupler) and any other auxillary items required for commissioning along with supply if required.

50

-

-

... More
Erection of 24 V, 80AH, Ni-Cd sealed type battery set and all other accessories complete.

5

-

-

... More
Erection of Float-cum-boost battery charger (SMPS based ) with full wave, full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery alongwith DCDB, connectors, surge protection device, etc. complete and connection with 24 V, 80AH Battery set and single phase AC input supply.

1

-

-

... More
Erection of 415V AC Distribution Board/Panel of sheet steel enclosed cubical with surge protection device floor mounting type for catering auxiliary power supply of the substation,etc. including supply of wires and any other materials required.

5

-

-

... More
Erection, testing and commissioning of 63 kVA, 11 kV/0.415 kV Station Transformer along with all accessories such as DO Fuse, Bushing Boots, HT/LT side connections from S/S Panel and upto AC Distribution Box(excluding laying), etc. as per TS along with supply of copper L-Joints for LT Bushing and any other accessories required.

5

-

-

... More
Erection of switchyard earthing mat for double transformer and related switchyard equipments using MS Round Bar of 40 mm dia by pegging and driving it 50cm below ground level including all fabrication work and erection of required no. of delta and connection of equipments with this mat using 75x8 MS strips.

5

-

-

... More
Erection of bus bar gantry using rail poles icluding grouting, painting, etc. for 2 different 33 kV sources having provision of inter-operability using a bus isolaor along with erection of lower and upper bus bar using Panther Conductor including supply of PG Clamps,T-Connector, Disc Fittings for Panther, etc. as per standard specifications and other required material

5

-

-

... More
Erection of required number of mounting structures for switchyard euipments such as VCB, LA, isolator, cable support structure, neutral structures, post insulator structures, CT, PT etc., then mounting of equipments along with grouting, foundation plinth, painting etc and any other required work as per standard specifications, approved drawings, UPPCL norms

5

-

-

... More
Construction of control cable trench by brick work, edges by 40x5 mm MS angle & plastering with trench cover having 40x5 mm MS Angle edges as per standard specifications.

250

-

-

... More
Laying of control cable for both transformers in switchyard and control room including ferruling, glanding and connections with the equipments

5

-

-

... More
Erection of Double Pole structures including grounting (1:3:6 CC mixture), foundation plinth (1:2:4 CC mixture), pole-painting along with fixing of channels, pin insulators, GI Pipe, danger board, barbed wire, earth wire, spike rod, stay set, etc.as per approved drawing and standard specification of UPPCL/RESSPO.

49

-

-

... More
Laying of 33 kV/11 kV/LT Cable including mounting on pole, MS structures, etc. by digging of trench at standard depth and using sand, bricks, etc as per approved drawing and standard specification of UPPCL/RESSPO.

8.21

-

-

... More
Erection, mounting and connection of heat shrinkable joints at poles, equipments, structures, etc.

206

-

-

... More
Erection and placement of fire extinguisher, sand buckets with stand, earth mat, etc at suitable locations

5

-

-

... More
Boring and lowering of Class-B 40 mm dia 20 feet long GI Pipe and connections with the power transformers(80 feet deep at 3 points and connection with MS Round Bar Delta) and other equipments(60 feet deep) as per standard practices including all necessary fabrication works and construction of 3 earth pits each for both power transformers

285

-

-

... More
Levelling of switchyard after back-filling of soil and using stone ballast for top surface including supply of all related materials

1000

-

-

... More
CAPACITY AUGMENTATION POWER TRANSFORMER

-

-

-

... More
Dismantling of existing Power Transformer after draining out radiator and conservator oil, shifting from the plinth and transporation to KESCo stores and safely place all parts in KESCo store in a reusable condition including any civil/fabrication work required for removing obstacles in path of dismantling/erection of power transformers

33

-

-

... More
Dismantling of the existing small sized plinth to make space for large sized 10/12.5/20 MVA Power Transformer

3

-

-

... More
Construction of power T/F plinth suitable for 10/12.5 MVA 33/11kV T/F in size of 3.5 x 3.5 x 1.5 Mtr. by digging of pit in size of 4.0 x 4.0 x 1.2 Mtr. of CC work and at bottom in size of 4.0 x 4.0 x .15 Mtr. with ratio of 1:3:6, its proper ramming and curing thereafter brick work in size of 3.5 x 3.5 x 0.8 Mtr. with 1 : 4 CC Sand ratio, thereafter CC work on top in size of 3.5 x 3.5 x .25 Mtr. thereafter plastering all around the open portion, grouting of rail and M.S. Angle in top CC work and its proper curing. Reinforcement by mesh of Steel TMT Bar of size 12mm.

3

-

-

... More
Construction of power T/F plinth suitable for 20 MVA 33/11kV T/F in size of 4.0 x 4.0 x 2.0 Mtr. by digging of pit in size of 4.5 x 4.5 x 1.5 Mtr. of CC work and at bottom in size of 4.5 x 4.5 x 0.30 Mtr. with ratio of 1:3:6, its proper ramming and curing thereafter brick work in size of 4.0 x 4.0 x 1.0 Mtr. with 1 : 3 CC Sand ratio, thereafter CC work on top in size of 4.0 x 4.0 x .0.40 Mtr. thereafter plastering all around the open portion, grouting of rail and M.S. Angle in top CC work and its proper curing. Reinforcement by mesh of Steel TMT Bar of size 16 mm.

3

-

-

... More
Erection, testing and commissioning of 10/12.5 MVA, 33/11 kV power T/F along with radiators, conservator tank, vent pipe, RTCC panel in control room and all other accessories on main tank after placement of rail pole 3 m long including erection of required number of CT/PT junction box and oil filling and all other related work/supply required for succesful commissioning.

3

-

-

... More
Erection, testing and commissioning of 20 MVA, 33/11 kV power T/F along with radiators, conservator tank, vent pipe, RTCC panel in control room and all other accessories on main tank after placement of rail pole 3 m long including erection of required number of CT/PT junction box and oil filling and all other related work/supply required for succesful commissioning.

6

-

-

... More
Erection of switchyard earthing mat for a single transformer and related switchyard equipments using MS Round Bar of 40 mm dia by pegging and driving it 50cm below ground level including all fabrication work and erection of required no. of delta and connection of equipments with this mat using 75x8 MS strips.

3

-

-

... More
Erection, grouting and painting of Isolator Structure with 1:3:6 CC 25 mm brick ballast in required size in proper alignment and making plinth of all structure in 1:2:4 CC mix with 20 mm stone grit, 15 Cm ground level to smooth finish and its proper curing including cost of cement, mounting of isolator and connection with earth mat

3

-

-

... More
Erection, grouting and painting of Post Insulator/L.A./C.T/P.T Structure/Cable Support Structure with 1:3:6 CC 25 mm brick ballast in required size in proper alignment and making plinth of all structure in 1:2:4 CC mix with 20 mm stone grit, 15 Cm ground level to smooth finish and its proper curing including cost of cement, mounting of Insulator/L.A./C.T/P.T. and connection with earth mat

15

-

-

... More
Erection, grouting and painting of Neutral Support Structure with 1:3:6 CC 25 mm brick ballast in required size in proper alignment and making plinth of all structure in 1:2:4 CC mix with 20 mm stone grit, 15 Cm ground level to smooth finish and its proper curing including cost of cement and connection with earth mat

3

-

-

... More
Erection, testing and commissioning of 33 kV Feeder/ Single Transformer Control Relay Panel and any other auxillary items required for commissioning along with supply if required.

3

-

-

... More
Erection, testing and commissioning of 11 kV VCB(I/C or O/G or Bus Coupler or Adapter Panel ) and any other auxillary items required for commissioning along with supply if required.

44

-

-

... More
Extension of main bus bar gantry/ erection of upper bus bar for additional power transformer including required grouting, painting, erection of lower bus, etc. and connection with earth mat.

3

-

-

... More
Construction of control cable trench by brick work, edges by 40x5 mm MS angle & plastering with trench cover having 40x5 mm MS Angle edges as per standard specifications.

100

-

-

... More
Laying of control cable for single transformer in switchyard and control room including ferruling, glanding and connections with the equipments

6.9

-

-

... More
Laying of 33 kV/11 kV/LT Cable including mounting on pole, MS structures, etc. by digging of trench at standard depth and using sand, bricks, etc as per approved drawing and standard specification of UPPCL/RESSPO.

1.8

-

-

... More
Erection, mounting and connection of heat shrinkable joints at poles, equipments, structures, etc.

96

-

-

... More
Boring and lowering of Class-B 40 mm dia 20 feet long GI Pipe and connections with the power transformers(80 feet deep) and connection with MS Round Bar Delta, if required for neutral earthing.

15

-

-

... More
Boring and lowering of Class-B 40 mm dia 20 feet long GI Pipe and connections with the switchyard/control room equipments (60 feet deep).

9

-

-

... More
Levelling of switchyard after back-filling of soil and using stone ballast for top surface including supply of all related materials

3

-

-

... More
11 kV Overhead Line Works

-

-

-

... More
Excavation of pole pit (of depth 1/6th of pole length) per scope of work, approved drawings and specifications:

-

-

-

... More
11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

3082

-

-

... More
9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

215

-

-

... More
Erection of following types of poles(For all types of Single/Double/Tri/Four Pole Structures) for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (Spike rod & 8SWG GI wire), red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) or/and 200 mm average size bolders mixed with excavated earth etc. along with 250 mm dia x 12 Inch size muffing using cement concrete of 1:2:4 (1 Part cement, 2 Part coarse sand and 4 Parts 20 mm aggregate stone chip) as per scope of work, approved drawings and specifications:

-

-

-

... More
11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985) for single ckt line

3082

-

-

... More
9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985).

215

-

-

... More
Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works including digging of suitable pit.

1457

-

-

... More
Erection, testing & commissioning of pre-fabricated galvanized steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of GS Channels, GS angle, GS flats of given sizes for over head structures and GS nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work.

93

-

-

... More
Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work including supply of suitable winding, any other material required

-

-

-

... More
11 kV Pin insulator with GI pin

9252

-

-

... More
11 kV Disc insulator(for bare/covered conductor) 70KN with strain hardware

3352

-

-

... More
Laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of ACSR Conductor/covered conductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications. This includes double circuit line as well existing single circuit to double circuit as well.

-

-

-

... More
6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - ACSR Dog Conductor

339

-

-

... More
11 kV covered conductor including required accessories

240

-

-

... More
Dismantling of existing pole,overhead line conductor & fittings and depositing to Employer store

-

-

-

... More
Old DOG/Weasel Conductor with all fittings

240

-

-

... More
Old 11/9.5/9 Mtr STP pole

382

-

-

... More
Strengthening of existing damaged pole by providing and welding 1.2mtr long 3 No MS angle 65*65*6mm and carrying out required grouting and pole plinth activities as per approved drawing and technical specification.

150

-

-

... More
Erection of 8 SWG GI wire for guarding by providing GI nut, bolts & washers, turn buckle etc

1.08

-

-

... More
11 KV UG Line Work

-

-

-

... More
Excavation of additional pole pit (of depth 1/6th of pole length) as per scope of work, approved drawings and specifications:

-

-

-

... More
11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)and Bottom Galvanised as per IS 2629 (1985)

24

-

-

... More
9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

36

-

-

... More
Erection of following types of poles for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (Spike rod and 8SWG GI wire), red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) volume 0.5 cub mtr. or/and 200 mm average size bolders mixed with excavated earth etc. along with 250 mm dia x 12 Inch size muffing using cement concrete of 1:2:4 (1 Part cement, 2 Part coarse sand and 4 Parts 20 mm aggregate stone chip) as per scope of work, approved drawings and specifications:

-

-

-

... More
11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985).

24

-

-

... More
9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

36

-

-

... More
Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works including Digging.

42

-

-

... More
Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.

-

-

-

... More
11 kV Pin insulator with GI pin

54

-

-

... More
Erection, testing & commissioning of pre-fabricated galvanized steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of GS Channels, GS angle, GS flats of given sizes for over head structures and GS nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work.

2.11

-

-

... More
Laying of 11kV cable through HDD method including digging of pit (without Pipe)

6.25

-

-

... More
Laying of 11 kV Cable in Air(Pole to Pole)

0.18

-

-

... More
Laying of 11kV cable through HDD method including digging of pit (with G.I. Pipe)

1.14

-

-

... More
Laying of 11kV cable through Molling method including digging of pit

1

-

-

... More
Digging of Trench .3 mtr wide 1.1 mtr to 1.5 mtr deep for laying of Pipe and Cable

-

-

-

... More
NORMAL SOIL

0.5

-

-

... More
SOFT ROCK / kharanja

0.5

-

-

... More
HARD ROCK / metallic road/ RCC

1

-

-

... More
Laying of GI Pipe 6" dia in above digged trench and for raising Cable on double Pole/Structure

0.11

-

-

... More
Laying of 11 kv Cable through above Pipe

0.11

-

-

... More
Laying of Cable in above digged trench and also mounting Upto line by using bricks/ sand &stone pad as per REC norms

2

-

-

... More
Making and Mounting of heat shrinkable jointing kit for 11 KV XLPE Cable

60

-

-

... More
Digging suitable Pit and making straight through joint 11 KV XLPE Cable

9

-

-

... More
Making of Straight Through joint

9

-

-

... More
Laying of 11 kv Cable with channel/pipe support from bottom upto pole top

0.16

-

-

... More
Distribution Transformers Works

-

-

-

... More
Excavation of pole pit (of depth 1/6th of pole length) per scope of work, approved drawings and specifications:

-

-

-

... More
11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

1218

-

-

... More
4 Mtr long Joist Girdar pole (1.5 Mtr below ground level)

1184

-

-

... More
Erection of following types of poles for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (Spike rod & 8SWG GI wire), red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) volume or/and 200 mm average size bolders mixed with excavated earth etc. along with 250 mm dia x 12 Inch size muffing using cement concrete of 1:2:4 (1 Part cement, 2 Part coarse sand and 4 Parts 20 mm aggregate stone chip) as per scope of work, approved drawings and specifications:

-

-

-

... More
Erection of 4 Mtr joist Gurader pole ( 1.5 Mtr below Ground level)

1184

-

-

... More
Erection of Double Pole structures including grouting (1:3:6 CC mixture), foundation plinth (1:2:4 CC mixture), pole-painting along with fixing of channels, pin insulators with pin,Disc insulator along with fitting, GI Pipe, danger board, barbed wire, earth wire, spike rod, etc.as per approved drawing and standard specification of UPPCL/RESSPO.

509

-

-

... More
Erection of Double pole structure with existing Single pole including grouting (1:3:6 CC mixture), foundation plinth (1:2:4 CC mixture), pole-painting along with fixing of channels, pin insulators, disc insulators, GI Pipe, danger board, barbed wire, earth wire, spike rod, etc.as per approved drawing and standard specification of UPPCL/RESSPO.

200

-

-

... More
Excavation, erection, testing & commissioning of Spike Earthing of 2540 mm long with 20mm solid Rod

2388

-

-

... More
Erection of 8 SWG GI wire for earthing and guarding by providing GI nut, bolts & washers, turn buckle etc

0.5

-

-

... More
Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works including digging of suitable pit.

1418

-

-

... More
Construction of T/F plinth, suitable for mounting of distribution transformer size of the plinth will be 1.2x1.2x1.2 meter solid with brick work. 75 mm thick C.C. in ratio 1:3:6 with cement, coarse sand and brick ballast laid on the base and 75 mm thick done on all the exposed sides to the plinth.

306

-

-

... More
Erection and Fabrication of T/F fencing of frame size 3x2.4 mtr. with gate and latch(size of fencing may vary as per site conditions) including cost of M.S. Angle size 40x40x5 and M.S. Flat size 50x6, fixing of welded steel wire fabric on steel frames by welding of 10 SWG wire fabric, including Painting of two coats of paint on iron based surfaces with ready mixed paint to give bus green shade including cleaning of oil and dust. Additional MS Strips 40x5 sqmm having height same as that of fencing to be placed vertically on the steel wire fabric at a distance of 0.5 m from one another for additional reinforcement and grouting of MS angle with 1:3:6 ratio (capable of bearing all load of Fencing)

16385

-

-

... More
Erection and Fabrication of T/F fencing of frame size 3x2.4 mtr. with gate and latch(size of fencing may vary as per site conditions) including cost of M.S. Angle size 40x40x5 and M.S. Flat size 50x6 including Painting of two coats of paint on iron based surfaces with ready mixed paint to give bus green shade including cleaning of oil and dust. Additional MS Strips 40x5 sqmm having height same as that of fencing to be placed vertically on the steel wire fabric at a distance of 75 mm from one another for additional reinforcement including of grouting of MS angle with 1:3:6 ratio (capable of bearing all load of Fencing)

7022

-

-

... More
Erection of LT Circuit 500A/500V on pole with proper fitting clamping and connection with Transformer using single core/three core cable.

1575

-

-

... More
Erection of DO Fuse set on double pole structure including required fabrication of MS items.

709

-

-

... More
Laying of 11 kV cable pole to pole with proper clamping and sagging on pole.

5.67

-

-

... More
Erection of 250/400 KVA Distribution transformer including proper connection of HT, LT side with AL Lug , L connector.

866

-

-

... More
Making and Mounting of heat shrinkable jointing kit for 11 KV 3x70/185 sqmm XLPE Cable

1418

-

-

... More
Erection of Bushing Boot on 11 kV side of Transformer

2127

-

-

... More
40 Feet deep bore separate Earthing ( 1 Neutral + 1 Body ) including laying and connecting of GI strip with transformer body/neutral with the GI pipe

709

-

-

... More
Dismantling of 63/100/160/250 KVA Distribuiton transformer including opening of existing HT/LT/Neutral Connection and depositing to employer store with proper safety.

157

-

-

... More
Erection and commissioning of LT ACB , making suitable foundation plinth (1:2:4 CC mixture), Connection with DT and LT Circuit using AL Lug and single core cable with crimping tool and other required accessorries.

1821

-

-

... More
Earthing of LT ACB , 40 feet deep bore GI Pipe earthing including and connection with ACB by using AL Lug, proper tightening with nut and boult.

1821

-

-

... More
COMPACT S/S WORKS

-

-

-

... More
Construction of T/F plinth suitable for mounting of CSS size and housing of 11 kV and LT cable

25

-

-

... More
4 No , 40 feet deep bore GI Pipe earthing including and connection with DT and RMU, and Substation by using AL Lug, proper tightening with nut and boult complete in all respect

25

-

-

... More
Erection and commissioning of 11/0.4 Kv compact packaged substation incuding conection on HT/LT side with proper tightening of connections by using LUGs and other sundary items.

25

-

-

... More
Digging of Trench .3 mtr wide 1.1 mtr to 1.5 mtr deep for laying of Pipe and Cable

-

-

-

... More
Normal soil

0.04

-

-

... More
Soft Rock / kharanja

0.04

-

-

... More
Hard Rock / metallic road/ RCC

0.31

-

-

... More
Laying of 11 Kv/ LT Cable in above digged trench and also mounting Upto line by using bricks/ sand &stone pad as per REC norms

1.25

-

-

... More
Making and Mounting of heat shrinkable jointing kit for 11 KV 3x70 sqmm XLPE Cable

50

-

-

... More
33 kV Over Head Line Work

-

-

-

... More
Excavation of pole pit (of depth 1/6th of pole length) per scope of work, approved drawings and specifications:

-

-

-

... More
13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and as per IS 2629 (1985)

1854

-

-

... More
11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and as per IS 2629 (1985)

63

-

-

... More
Erection of following types of poles(including single/double triple/four pole structures) for 33 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material ( Spike rod & 8SWG GI wire), red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) and 200 mm average size bolders mixed with excavated earth etc. along with 250 mm dia x 12 Inch size muffing using cement concrete of 1:2:4 (1 Part cement, 2 Part coarse sand and 4 Parts 20 mm aggregate stone chip) as per scope of work, approved drawings and specifications:

-

-

-

... More
13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

1854

-

-

... More
11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985).

63

-

-

... More
Conversion of existing Single ckt line to Double circuit line.

10

-

-

... More
Erection, testing & commissioning of pre-fabricated galvanized steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of GS Channels, GS angle, GS flats of given sizes for over head structures and GS nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work.

79.17

-

-

... More
Erection of 8 SWG GI wire for guarding by providing GI nut, bolts & washers, turn buckle etc

0.42

-

-

... More
Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works including digging of suitable pit.

1459

-

-

... More
Erection, testing and commissioning of 33 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.

-

-

-

... More
33 kV Pin insulator with GI pin

5274

-

-

... More
11 kV Disc insulator 70KN

11696

-

-

... More
11 kV Disc Fitting

2924

-

-

... More
Laying out, tensioning, binding of conductor and stringing, testing and commissioning of ACSR Conductor/covered conductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications

-

-

-

... More
6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - ACSR Dog Conductor

434.22

-

-

... More
33 kV covered conductor including required accessories

267

-

-

... More
Dismantling of existing pole ,overhead line conductor & fittings and depositing to Employer store

-

-

-

... More
Old Weasel/DOG/Panther Conductor

612

-

-

... More
13/11 Mtr STP Pole

972

-

-

... More
Strengthening of existing damaged pole by providing and welding 1.2mtr long 3 No MS angle 65*65*6mm and carrying out required grouting and pole plinth activities as per approved drawing and technical specification.

388

-

-

... More
Construction of New 33 KV UG Lines

-

-

-

... More
Excavation of pole pit (of depth 1/6th of pole length) per scope of work, approved drawings and specifications:

-

-

-

... More
13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

24

-

-

... More
11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

448

-

-

... More
Erection of following types of poles(including single/double triple/four pole structures) for 33 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material ( Spike rod & 8SWG GI wire), red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) and 200 mm average size bolders mixed with excavated earth etc. along with 250 mm dia x 12 Inch size muffing using cement concrete of 1:2:4 (1 Part cement, 2 Part coarse sand and 4 Parts 20 mm aggregate stone chip) as per scope of work, approved drawings and specifications:

-

-

-

... More
13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)and Bottom Galvanised as per IS 2629 (1985).

24

-

-

... More
11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

448

-

-

... More
Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works including Digging.

24

-

-

... More
Erection, testing and commissioning of 33 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.

-

-

-

... More
33 kV Pin insulator with GI pin

672

-

-

... More
11 kV Disc insulator 70KN

144

-

-

... More
11 kV Disc Fitting

36

-

-

... More
Erection, testing & commissioning of pre-fabricated galvanized steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of GS Channels, GS angle, GS flats of given sizes for over head structures and GS nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work.

8.96

-

-

... More
Laying of 33kV cable through HDD method including digging of pit (without Pipe)

80

-

-

... More
Laying of 33kV cable through HDD method including digging of pit (with G.I. Pipe)

0.81

-

-

... More
Laying of 33 kV In air(pole to Pole)

2

-

-

... More
Laying of 33 kV cable through Molling method including digging of pit

12

-

-

... More
Digging of Trench .3 mtr wide 1.1 mtr to 1.5 mtr deep for laying of Pipe and Cable

-

-

-

... More
Normal soil

3

-

-

... More
Soft Rock / kharanja

3

-

-

... More
Hard Rock / metallic road/ RCC

19

-

-

... More
Laying of GI Pipe 6" dia in above digged trench and for raising Cable on double Pole/Structure

1.41

-

-

... More
Laying of 33 kv 3x300/400 sqmm Cable through above Pipe

1.41

-

-

... More
Laying of Cable in above digged trench and also mounting Upto line by using bricks/ sand &stone pad as per REC norms

25

-

-

... More
Laying of 33 kv Cable upto pole

2.74

-

-

... More
Making and Mounting of heat shrinkable jointing kit for 33 KV 3x300/400 sqmm XLPE Cable

372

-

-

... More
Digging suitable Pit and making straight through joint 33 KV 3x300/400 sqmm

50

-

-

... More
Making of 33 kV Straight Through joint

50

-

-

... More
33 kv line on Lattice pole

-

-

-

... More
Erection of Lattice MS Structure Tower 16 m Height including, Suitable 33 kV Brackets with fixable spacers of adequate insulating materials , other minor accessories required, polymeric pin and Disc Insulators including grouting (1:1.5:3 CC mixture min 2 Cubicmtr ), foundation plinth (1:2:4 CC mixture), 40 feet deep bore earthing

26

-

-

... More
Laying of insulated covered conductor on M+4 Tower with proper sagging, including erection of all required accessorries

9.45

-

-

... More
33 kV mid line Isolator

-

-

-

... More
Erection of 33 kV Isolator with structure including grouting of MS structure (1:3:6 CC mixture ), fabrication,painting and other work required for erection.

46

-

-

... More
Erection/ Fixing of 33 kV Fuse set with structure including fabrication and other work required for erection.

23

-

-

... More
Excavation of pole pit (of depth 1/6th of pole length) per scope of work, approved drawings and specifications:

-

-

-

... More
13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and Bottom Galvanised as per IS 2629 (1985)

92

-

-

... More
Erection of following types of poles(including single/double triple/four pole structures) for 33 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material ( Spike rod & 8SWG GI wire), red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) and 200 mm average size bolders mixed with excavated earth etc. along with 250 mm dia x 12 Inch size muffing using cement concrete of 1:2:4 (1 Part cement, 2 Part coarse sand and 4 Parts 20 mm aggregate stone chip) as per scope of work, approved drawings and specifications:

-

-

-

... More
13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and as per IS 2629 (1985) and Bottom Galvanised as per IS 2629 (1985)

92

-

-

... More
Erection, testing and commissioning of 33 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.

-

-

-

... More
33 kV Pin insulator with GI pin

276

-

-

... More
11 kV Disc insulator 70KN

1104

-

-

... More
11 kV Disc Fitting

276

-

-

... More
Earthing arrangement as per technical specificatons, approved drawings and scope of work.

-

-

-

... More
Earthing with 40 feet deep bore GI Pipe earthing including connection ,proper tightening with nut and boult.

23

-

-

... More
Laying of single core 33 kV ,1x400 sqmm cable pole to pole with proper clamping and sagging on pole.

1

-

-

... More
33/11 kV S/S Switchgear

-

-

-

... More
Erection, testing and commissioning of 33 kV Indoor VCB incommer/outgoing /Bus Coupler/ with CRP and any other auxillary items required for commissioning along with supply if required including dissconneting and reconnecting of Existing earthing by extending and welding, painting MS Flat 50x6.

74

-

-

... More
Dismantling of 33 kV VCB including all required activity and depositing of material at employer store.

24

-

-

... More
Dismantling of 33 kv CRP including all required activity and depositing of materials at employer store.

24

-

-

... More
Erection, testing and commissioning of 33 kV Feeder/ Single Transformer Control Relay Panel and any other auxillary items required for commissioning along with supply if required including dissconneting and reconnecting of Existing earthing by extending and welding, painting MS Flat 50x6.

14

-

-

... More
Erection, testing and commissioning of 33 kV Double Transformer Control Relay Panel and any other auxillary items required for commissioning along with supply if required including dissconneting and reconnecting of Existing earthing by extending and welding, painting MS Flat 50x6.

4

-

-

... More
Erection, testing and commissioning of 33 kV VCB and any other auxillary items required for commissioning along with supply if required including dissconneting and reconnecting of Existing earthing by extending and welding, painting MS Flat 50x6.

22

-

-

... More
Erection, testing and commissioning of 11 kV VCB(I/C,O/G and Bus Coupler) and any other auxillary items required for commissioning along with supply if required including dissconneting and reconnecting of Existing earthing by extending and welding, painting MS Flat 50x6.

86

-

-

... More
Erection, testing and commissioning of 11 kV Adapter panel

10

-

-

... More
Dismantling of 11 kV VCB including all required activity and depositing of employer store.

30

-

-

... More
Erection of 24 V, 80AH, Ni-Cd sealed type battery set and all other accessories complete.

47

-

-

... More
Erection of Float-cum-boost battery charger (SMPS based ) with full wave, full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery , connectors, surge protection device, etc. complete and connection with 24 V, 80AH Battery set and single phase AC input supply.

46

-

-

... More
Erection of 415V AC Distribution Board/Panel including supply of wires and any other materials required.

65

-

-

... More
Erection of DC Distribution Board/Panel including supply of wires and any other materials required.

65

-

-

... More
Erection and commissioning of newly erected CT along with connection to Marshelling box, connection with earth strip and other activity required for successful commissioning

153

-

-

... More
Dismantling of Existing CT and deposit of material at employer store.

60

-

-

... More
Erection and commissioning of newly erected PT along with connection to Marshelling box, connection with earth strip and other activity required for successful commissioning

136

-

-

... More
Dismantling of Existing PT and deposit of material at employer store.

40

-

-

... More
Erection of Lightening Arrestor including connection with earth strip

215

-

-

... More
Dismantling of non-function LA and depsoit of material in KESCo store

100

-

-

... More
Laying of control cable for in switchyard and control room including ferruling, glanding and connections with the equipments

24.1

-

-

... More
Laying of 11 kV Cable including mounting on pole, MS structures, etc. by digging of trench at standard depth and using sand, bricks, etc as per approved drawing and standard specification of UPPCL/RESSPO.

13.64

-

-

... More
Erection, mounting and connection of heat shrinkable joints at poles, equipments, structures, etc.

396

-

-

... More
LT Line Work Aerial Bunch Cable

-

-

-

... More
Excavation of pole pit (of depth 1/6th of pole length) per scope of work, approved drawings and specifications:

-

-

-

... More
9 M long PCC pole

7885

-

-

... More
Erection of PCC poles along with stone pad for LT overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per scope of work, approved drawings and specifications:

7885

-

-

... More
Erection of galvanized Stay Set with 50x8 mm stay clamp, stay guy insulator, nut bolts, 2 Nos turn buckle's , 1.8 m long, 16 mm diamater solid GS Stay rod and 7/3.15 mm dia GI stranded wire etc as required by providing 0.2 cum cement concrete as per approved drawing, techhnical specification and scope of work including digging of suitable pit.

3505

-

-

... More
Erection, testing and commissioning of new Aerial Bunched XLPE Cable, tension clamps for dead end, suspension clamps, clamps for neutral,neutral bare connector, piercing connectors type-I & type-II 16 mm dia MS nuts and bolts, pole clamps, spring loaded bus bar suitable for single phased and three phase systems etc. as required as per technicla specification, approved drawing and scope of work.

-

-

-

... More
Erection of AERIAL BUNCHED XLPE CABLE 3x120+1x95+1x16 sqmm with all assecessiories.

360.15

-

-

... More
Erection of AERIAL BUNCHED XLPE CABLE 3x150+1x125+1x16 sqmm with all assecessiories.

375.9

-

-

... More
Erection & commissioning of Single Phase CRCA MS Deep Drawn Distribution Box with clamps with 1x25 sqmm xlpe cable ,lug and all accessories.

3505

-

-

... More
Erection & commissioning of Three Phase CRCA MS Deep Drawn Distribution Box ith clamps with 1x25 sqmm xlpe cable ,lug and all accessories.

1752

-

-

... More
Erection & commissioning of Single Phase SMC Distribution Box with clampsith clamps with 1x25 sqmm xlpe cable ,lug and all accessories.

3505

-

-

... More
Erection & commissioning of Three Phase SMC Distribution Box ith clamps with 1x25 sqmm xlpe cable ,lug and all accessories.

1752

-

-

... More
Erection, testing & commissioning of earthing by inserting GI Earthing spike 2540 mm long made of 20mm solid Rod as per approved drawings, scope of work and technical specifications

2103

-

-

... More
Erection of 8 SWG G.I. wire for earthing

5.26

-

-

... More
Shifting of Existing consumer connection to newly erected AB Cable line/DOG Conductor Line

-

-

-

... More
Single Phase Connection

20000

-

-

... More
Three Phase Connection

2500

-

-

... More
LT Line Work with ACSR Dog Conductor

-

-

-

... More
Excavation of additional pole pit (of depth 1/6th of pole length) in soft rock/ mettalic road/ RCC / kharanja as per scope of work, approved drawings and specifications:

-

-

-

... More
9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as per IS 2629 (1985)

1015

-

-

... More
Erection of following types of poles for LT overhead line by providing and installing danger plate anti climbing devices (barbed wire), red oxide & aluminium paint including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) volume 0.5 cub mtr. or/and 200 mm average size bolders mixed with excavated earth etc. along with 250 mm dia x 12 Inch size muffing using cement concrete of 1:2:4 (1 Part cement, 2 Part coarse sand and 4 Parts 20 mm aggregate stone chip) as per scope of work, approved drawings and specifications.

-

-

-

... More
9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as per IS 2629 (1985)

1015

-

-

... More
Erection, testing & commissioning of pre-fabricated galvanized steel items like LT Bracket,clamp, bracket, clamps, GS nuts, bolts & washers including as per technical specification, approved drawings and scope of work for PCC Pole

11.27

-

-

... More
Erection, testing & commissioning of earthing by inserting GI Earthing spike 2540 mm long made of 20mm solid Rod as per approved drawings, scope of work and technical specifications

203

-

-

... More
Erection of 8 SWG G.I. wire for earthing

0.51

-

-

... More
Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works including digging of suitable pit.

290

-

-

... More
Erection, testing and commissioning of LT insulator including their hardware fittings as per technical specification, approved drawings and scope of work.

-

-

-

... More
Pin insulator with GI pin/ Shackle insulator with strip

4640

-

-

... More
Laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of ACSR Conductor/covered conductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications

-

-

-

... More
6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - ACSR Dog Conductor

121.8

-

-

... More
Strengthening of existing damaged pole by providing and welding 1.2mtr long 3 No MS angle 65*65*6mm and carrying out required grouting and pole plinth activities as per approved drawing and technical specification.

58

-

-

... More
Line Switching and Isolation

-

-

-

... More
Erection and commissioning of 33 kV FPI including required accessories

174

-

-

... More
Erection and commissioning of 11 kV FPI including required accessories

947

-

-

... More
Erection, Fabrication & commissioning of pre-fabricated channels, back clamp, etc made of GS Channels, GS angle, GS flats of given sizes for over head structures and GS nuts, bolts & washers as per technical specification, approved drawings and scope of work.

2.1

-

-

... More
Erection and commissioning of Gang operated Devices on pole including all fitting, Making connection with existing line using jumper of insulated Dog, and AL lug etc and other required work for commissioning as per standard specifications, approved drawings, UPPCL norms

1027

-

-

... More
Erection and commissioning of Dissconnecting link on pole including all fitting, Making connection with existing line using jumpher, insulated Dog, and AL lug etc and other required work for commissioning as per standard specifications, approved drawings, UPPCL norms

1044

-

-

... More
Mounting of Horizontal Isolator on the structure along with grouting, foundation plinth, painting, Earthing, Making connection with 11 KV Line etc and any other required work as per standard specifications, approved drawings, UPPCL norms

30

-

-

... More
Conversion of Exisiting LT Bare Conductor Line into LT Under Ground Network.

-

-

-

... More
Erection of Cable end termination using total double compression Brass glands and crimping type aluminum thimbles

8448

-

-

... More
Digging of pits after due survey with the help of utility detector of existing electrical/telephonic cable/and other utilites of public utilites department and laying and commissioning of cables of size 3.5 CX300/240/120/70 Sq mm. XLPE by manual drill (by making moles)

255

-

-

... More
Digging of pits after due survey with the help of utility detector of existing electrical/telephonic cable/and other utilites of public utilites department and laying and commissioning of cables of size 3.5 CX300/240/120/70 Sq mm. XLPE through HDD method with the help of HDD Machine

55

-

-

... More
Digging of trench by open trench method after due survey with the help of utility dectector of existing /telephonic cable and other utilites of public utilites department and laying and commissioning of cables of size3.5 CX300/240/120/70 Sq mm. XLPE

55

-

-

... More
Back filling and conversion of the road into motorable status again

96

-

-

... More
Laying of HDPE pipe of various sizes by horizontal drilling for under ground piping (trenchless) for above cable at road crossing min. depth of pipe shall be 1.5 mtr. Below surface 110 mm. dia.

14.4

-

-

... More
Laying of GI Pipe of 50mm dia (External area)

9.6

-

-

... More
Laying of GI Pipe of 40mm dia (External area)

48

-

-

... More
Laying of PVC pipe heavy gauge 40 mm dia (under ground area)

112.32

-

-

... More
Erection of G.I. Strip/M.S. Strip of size 25x3/50x6 sqmm connecting pannel with spike rod/deep bore earthing arrangement including required bolting/welding

10.23

-

-

... More
Dismantling of Existing LT overhead line including STP poles, bare conductor/A.B. Cable, pole accessories and transportation of Dismantled materials to KESCO Store.

96

-

-

... More
Laying of Aluminum armored XLPEs cables size 2X6 Sq mm. upto consumer meter

76.8

-

-

... More
Laying of Aluminum armored XLPEs cables size 2X10 Sq mm. upto consumer meter

27.6

-

-

... More
Laying of Aluminum armored XLPEs cables size 2X16 Sq mm. upto street light point

192

-

-

... More
Laying of Aluminum armored XLPEs cables size 4X16 Sq mm. upto consumer meter

67.2

-

-

... More
Laying of Aluminum armored XLPEs cables size 4X25Sq mm. upto consumer meter

96

-

-

... More
Installation, Testing & Commissioning of Outdoor Type A-2/A-3/A-4 LT Distribution Box including all civil work required as per specification and approve drawings

96

-

-

... More
Installation, Testing & Commissioning of Outdoor type B-1/B-2/B-3 LT feeder pillar panel including all civil work required as per specification and approve drawings

576

-

-

... More
Installation, Testing & commissioning of lockable distribution box along with bar lock of size 450x450 mm including suitable foundation with bus bar 140 amp. TPN to feed up to 10 houses (Type C) mounting with G.I. angle of size 65x65x6mm

3840

-

-

... More
Erection, testing and commissioning of street light junction box and connection of street lamps of Nagar Nigam

1200

-

-

... More
Boring upto 40 feet and erection of GI Pipe 40mm dia B-Class 40 feet long for connection with Type-A/B FSP panel along with supply of G.I. Strip of size 50x6 sqmm

1210

-

-

... More
Erection/Pegging of M.S.EARTH spike ROD 2540X20 MM

7680

-

-

... More
Preparation and submission of 2 sets of detailed printed drawing/auto cad drawing / PDF (along with digital copy) of L.T. network of each D.T. depicting location of L.T. cables and all panels(Type-A,B and C) and separate list for all connections on Type C panels in excel format

96

-

-

... More
POLE INSULATION

-

-

-

... More
Supply and Erection of Insulation material on 33 kV/ 11 kV/ LT pole in market area.

1025

-

-

... More
SWITCH YARD EXTENSION

-

-

-

... More
Dismantling of minor civil / MS Structure and levelling of yard, erection of barbed wire fence with mid-supporting structures and small gate.

5

-

-

... More
Levelling of switchyard after back-filling of soil including supply of all related materials

5

-

-

... More
Charges for Railway Crossing Permission

8

-

-

... More
Charges for Highway Crossing Permission

4

-

-

... More
CONSTRUCTION OF CONTROL ROOM BUILDING, BOUNDARY WALL, SECURITY WALL, GATE, APPROACH ROAD, WATER SUPPLY SANITARY & ASSOCIATED CIVIL WORKS AT 33/11 K.V. NEW SUB-STATION

-

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (CSI 2.31)

7500

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.(CSI 2.6.1)

2352

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources(CSI 4.1.8)

660

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars(CS I 5.22.1)

81

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources(CSI 5.1.2)

270

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, of :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)excluding cost of centering, shuttering, finishing and reinforcement (CSI 5.2.2)

210

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand( CSI 6.1.2)

510

-

-

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(CSI 2.27)

210

-

-

... More
Earth filling under floors and/or corporation area including cost of earth obtained with in 8 km distance outside corporation area including all taxes (if any) and its carriage including watering, ramming in 20 cm layers and dressing of earth etc. all complete. (OLD CSI No. 4.10)

870

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.(CSI 2.25)

2352

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(CSI 5.3)

330

-

-

... More
Concreting of 40 mm thick RCC trench covers in mild steel frame work with RCC 1:1.5:3 in Cement, coarse sand and 2cm gauge graded hard stone ballast with 3mm thick floating coat of neat cement finish on top of cover complete with all labour, materials and placing the same in proper position at required location of cable trench within the substation area. (OLD CSI No. 5.18)

90

-

-

... More
Placing of trench cover of all size in proper position including transportation from different places within the S/S area including all labour, T&P etc. required for proper completion of the work as per direction of Engineer - in - charge. (CSI No. 20.11)

180

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete CSI 5.9.1

1680

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (CSI 5.9.3)

2100

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilever (CSI 5.9.5)

1500

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. (CSI 5.9.6)

1320

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand):(CSI 6.4.2)

570

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(CSI 10.2)

21

-

-

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 course sand) external plastic are for height upto 10m from ground level in less otherwise stated.(CSI 13.4.2)

3600

-

-

... More
15 mm cement plaster of mix :1:6 (1 cement: 6 course sand) external plastic are for height upto 10m from ground level in less otherwise stated.(CSI 13.5.2)

4800

-

-

... More
12 mm cement plaster of mix :1:4 (1 cement: 4 course sand) finished with a floating coat of neat cement of mix enternal & external plaster are for height upto 10m from ground level in less otherwise stated.(CSI 13.7.2)

1080

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(CSI 4.1.2)

456

-

-

... More
Kota stone slab of 25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) :(CSI 11.26)

660

-

-

... More
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.(CSI 16.68)

630

-

-

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.(CSI 11.40)

120

-

-

... More
Providing and laying Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(CSI 11.56.1)

48

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work., (OLD CSI No. 28.19)

90

-

-

... More
S/F Galvanized Mosquitos proof heavy quality iron wire gauge (14x24) over window frames and including supply of C.P. Teak wood battens 8cm x 1cm. and including supply and fixing of necessary screws, all materials,labour and T&P etc. required for proper complete. (OLD CSI No. 8.44)

102

-

-

... More
Providing and fixing G.I. chain link fabric fencing Made of G.I. wire of dia 4 mm of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer- in-charge.(CSI 16.70.1)

1200

-

-

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators,Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment).(CSI 10.11.1)

2100

-

-

... More
Renewing panes of 4.8 to 5.7 mm glass including supply of glass with putty and brads including supply of all materials, labour and t&P etc. required for proper completion of the work.(a) glass of 5 mm thick. (CSI No. 20.04)

120

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.( CSI 9.20.1)

72

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer- in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(CSI 12.50)

540

-

-

... More
S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . except cost of M.S angle and flat. ( OLD CSI No. 9.22)

72

-

-

... More
Arranging and spreding 75 mm thick broken grit 20 mm (Granite stone) uniform for turfing over 100mm thick base course of C.C. In 1:4:8 (1cement:4coarse sand: 8, 40mm stone ballast) top finish by brooming of cement mortar 1:4(1cement: 4 Coarse sand) including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No. 29.2)

2400

-

-

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. (CSI 5.30)

450

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(CSI 13.80)

8400

-

-

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.(CSI 13.41.1)

3600

-

-

... More
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. (CSI 13.45.1)

4800

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (CSI 13.62.1)

1500

-

-

... More
Supply and filling brick bat in soak pit including all labour,material and T&P etc complete. (for 01 soak pit)NSI Ref No. 6.23

30

-

-

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.(CSI 15.60)

90

-

-

... More
Supply and fixing of Syntex or equivalent make water storage tank including all materials, labours, T&P etc required for proper completion of work. ( OLD CSI No. 26.12)

3000

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore.(CSI 18.18.3)

6

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes OF 25 mm dia having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(CSI 18.9.3)

144

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes OF 20 mm dia conceled in wall including cutting and making good the wall having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(CSI 18.8.2)

108

-

-

... More
Providing and laying SWR,110 mm Dia PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. ( OLD CSI No. 27.29 c)

120

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.(CSI 17.1.1)

6

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.(CSI 17.7.1)

6

-

-

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.(CSI 17.23)

6

-

-

... More
Providing and fixing P.V.C. waste Flexible pipe of 40 mm dia pipe for sink or wash basin including P.V.C. waste fittings complete. (CSI 17.28.2.2)

12

-

-

... More
Providing and fixing 100 mm sand cast Iron grating for gully trap.(CSI 17.29)

12

-

-

... More
Supply and fixing CP Nahani Trap India make of heavy approved quality complete with CI grating, including supply of all materials,labour and T&P etc. required for proper completion of the work. (CSI No. 27.21a)

6

-

-

... More
Providing and fixing soap dish chromium plated with brackets fixed to wooden cleats with brass screws including supply of all materials,labour and T&P etc.required for proper completion of the work. (OLD CSI No. 27.19)

6

-

-

... More
Providing and fixing 600 mm x 20 mm size C.P. brass towel rail of approved quality including brackets including supply of all materials,labour and T&P etc. required for proper completion of the work and cutting and making good the wall plaster etc. required for work. (OLD CSI No. 27.17)

6

-

-

... More
Providing and fixing 600 mm x 450 mm beveled edge mirror of Atul,Kiran makeglass with Indian polish 6.50 mm thick complete with back of 600 mm x 450 mm x 6 mm hard board sheet fixed to wooden cieats with C.P. brass screws and washers including supply of all materials, labour and T&P etc.required for proper completion of the work. (OLD CSI No. 27.15)

6

-

-

... More
Supply and fixing CP Nahani Trap India make of heavy approved quality complete with CI grating, including supply of all materials,labour and T&P etc. required for proper completion of the work. (OLD CSI No. 27.21B)

6

-

-

... More
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length.(CSI 18.74.2)

18

-

-

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore (CSI 18.49.1)

24

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore.(CSI 18.53.1)

18

-

-

... More
Providing and fixing gun metal gate valve 25 mm nominal bore with C.I. wheel of approved quality (screwed end) :(CSI 18.17.1)

6

-

-

... More
Providing and fixing CP BRASS CP BRASS PILLER COCK 15 mm dia. HEAVY QUALITY ( 400gm) ( L & K and equi.) fittings, ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. ( OLD CSI No. 26.16 J)

6

-

-

... More
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit concealed in wall, GP Box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 131-C)

210

-

-

... More
Wiring point for plug with 1 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit conceled in wall with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 134-C)

72

-

-

... More
Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit conceled in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 123-C)

54

-

-

... More
Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. (PWD 1139)

108

-

-

... More
Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia PVC conduit on surface, with one number 2.5 sq. mm. multistrand copper drawn in conduit complete in all respect. (PWD 216-C)

900

-

-

... More
Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.(CSI 29.135)

210

-

-

... More
Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI 29.133)

18

-

-

... More
Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.(OLD CSI No. 28.39)

36

-

-

... More
S/R of regulator for ceiling fan of GEC or equivalent make including cost of all labour material, T&P etc. required for proper completion of the work. ( CSI 22.60b)

36

-

-

... More
S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve. (PWD C.S.I.No. 1002-B)

36

-

-

... More
S&F of 100 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (PWD C.S.I. No. 378)

6

-

-

... More
Supply and fixing of LED street light fitting having dia cast aluminum body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 production complete in all respect. (PWD 1424)

60

-

-

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.). (CSI 10.18)

72

-

-

... More
Pre-Construction anti-termite treatment, by creating a barrier under and around the columns pits, foundation trenches, under floors, junctions of Walls & floors, around the external perimetre of building, expansion joints, surrounding of pipes and conduits etc. (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981))with Eldrine emulsifiable 0.2% concentration or any other approved material such as Heptachlore or chlordance will be used. The consumption of emulsion shall be (i) Foundation and masonary @ 5 Ltrs/Sqm, (ii) Back fills in immediate contact of foundation@ 7.5 Ltrs. / Sqm, (iii) Top surface of Plinth filling @ 5 Ltrs / Sqm, ( iv) Junction of walls & floors @ 7.5 Ltrs / Sqm, (v) Soil along external perimetre of building @ 7.5 Ltrs / Sqm (vi) under apron of the building @ 5 Ltrs. /Sqm. The rates includes cost of all materials, labour, equipments, T&P complete.(CSI 29.41)

1080

-

-

... More
Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required for proper completion of work. (OLD CSI No. 19.03)

6

-

-

... More
Drilling for 200 mm dia bore fromrom 0 M BGL to 90 M BGL work to be completed as per direction of Engineer I/C .(OLD CSI 19.04G I)

540

-

-

... More
Drilling for 200 mm dia bore fromrom 90M BGL to 120 M BGL work to be completed as per direction of Engineer I/C .(OLD CSI 19.04G II)

180

-

-

... More
Lowering of tube well assembly alongwith shrouding with pea gravels, testing, verticality of Tube well and washing of the tube well from G.L. to90 Meter B.G.L. the cost including all labour, materials, T&P required for proper completion of work but excluding the cost of slotted pipe/ plain M.S/PVC.pipe assembly and Pea gravel.(OLD CSI No. 19.05I)

540

-

-

... More
Lowering of tube well assembly alongwith shrouding with pea gravels, testing, verticality of Tube well and washing of the tube well from 90. to 120Meter B.G.L. the cost including all labour, materials, T&P required for proper completion of work but excluding the cost of slotted pipe/ plain M.S/PVC.pipe assembly and Pea gravel.(OLD CSI No. 19.05II)

180

-

-

... More
Providing 160mm dia Plain PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. (OLD CSI No. 19.09)

540

-

-

... More
Providing 160mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. (OLD CSI No. 19.09)

180

-

-

... More
Development of tubewell by O.P. Unit (5 HP to 10 HP submersible pump set), including bringing Column pipe for the OP unit, assembling, electric connections, running for required period, dismentling and taking out & carrying away and cleaning the site with cost of all labour, materials, T&P and fuel / Electricity Charges etc required for proper completion of work and as per direction of Engineer-in-charge. (OLD CSI No. 19.14)

288

-

-

... More
Supply and fixing of MS ring of heavy quality OF 150 MM DIA including cost of all materials, labour and T&P etc required for proper completion of work. (CSI 29.43e)

6

-

-

... More
Supply and fixing of PVC. bail plug of heavy quality of 110 mm dia including all labour material & T&P.(CSI 29.46a)

6

-

-

... More
Supply and fixing of PVC top plug of heavy quality of 160 mm dia including all labour material & T&P. (CSI 29.47a)

6

-

-

... More
Supply and fixing of 1.20m long holding support clamps for 300 to 100mm dia tube well pipes. made out of MS flats, pairs of bolt-nuts etc complete with all material, labour, T&P. (OLD CSI No. 19.21)

6

-

-

... More
Supply and stacking pee gravel properly at levelled ground for measurement as directed by Engineer I/C, including all labour, T&P required for proper completion of work. (OLD CSI No.19.25)

18

-

-

... More
Supply & Installation of submersible pump of K.S.B/ CALAMA. or eqt. Make of 3 HP outlet 50 mm dia. or more, Head 60/24, Discharge 6000/14000 LPH including cost of labour, T&P and material required for completion of work. (CSI 29.55d)

6

-

-

... More
Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset for 3 H.P pump set single phase containing contractor relay condenser. (CSI 29.54c)

6

-

-

... More
Supply and fixing of submersible cable Havels or equivalent make, for submersible pump of 2.5 mm2 for pump above 1 HP and up to 3 HPcomplete in all respect. (OLD CSI No.19.33 b )

540

-

-

... More
Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (CSI 29.56)

360

-

-

... More
Supply and fixing of G.I. ("B" class ) column pipes of 40 mm dia JTC/ JINDAL make with column coupling socket as required for proper completion of work including all labour material & T&P. (OLD CSI No. 19.22)

360

-

-

... More
Lowering of M.S. column pipe of 40 to 50 mm dia in tubewell including supply of nuts, and bolts, packing and also carriage of pipe from workshop to site including all labour, T&P etc. required for proper completion of the work. (OLD CSI No.19.27 b )

360

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR EL No 5.6)

6

-

-

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.(DSR EL No 5.12)

60

-

-

... More
CONTROL ROOM EXTENTION AT EXISTING 33/11 K.V. SUB- STATION

-

-

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(CSI 15.3)

26

-

-

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.(CSI 15.7.4)

39

-

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.(CSI 15.2.1)

26

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.(CSI 2.6.1)

247

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources(CSI 4.1.8)

97.5

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars(CS I 5.22.1)

39

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources(CSI 5.1.2)

44.85

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, of :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)excluding cost of centering, shuttering, finishing and reinforcement (CSI 5.2.2)

52

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand( CSI 6.1.2)

78

-

-

... More
Earth filling under floors and/or corporation area including cost of earth obtained with in 8 km distance outside corporation area including all taxes (if any) and its carriage including watering, ramming in 20 cm layers and dressing of earth etc. all complete. (OLD CSI No. 4.10)

195

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.(CSI 2.25)

247

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(CSI 5.3)

78

-

-

... More
Concreting of 40 mm thick RCC trench covers in mild steel frame work with RCC 1:1.5:3 in Cement, coarse sand and 2cm gauge graded hard stone ballast with 3mm thick floating coat of neat cement finish on top of cover complete with all labour, materials and placing the same in proper position at required location of cable trench within the substation area. (OLD CSI No. 5.18)

325

-

-

... More
Placing of trench cover of all size in proper position including transportation from different places within the S/S area including all labour, T&P etc. required for proper completion of the work as per direction of Engineer - in - charge. (CSI No.20.11)

390

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete CSI 5.9.1

195

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (CSI 5.9.3)

520

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilever (CSI 5.9.5)

260

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. (CSI 5.9.6)

195

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand):(CSI 6.4.2)

182

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(CSI 10.2)

3.25

-

-

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 course sand) external plastic are for height upto 10m from ground level in less otherwise stated.(CSI 13.4.2)

1430

-

-

... More
15 mm cement plaster of mix :1:6 (1 cement: 6 course sand) external plastic are for height upto 10m from ground level in less otherwise stated.(CSI 13.5.2)

1040

-

-

... More
12 mm cement plaster of mix :1:4 (1 cement: 4 course sand) finished with a floating coat of neat cement of mix enternal & external plaster are for height upto 10m from ground level in less otherwise stated.(CSI 13.7.2)

520

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(CSI 4.1.2)

52

-

-

... More
Kota stone slab of 25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :(CSI 11.26)

520

-

-

... More
S/F Galvanized Mosquitos proof heavy quality iron wire gauge (14x24) over window frames and including supply of C.P. Teak wood battens 8cm x 1cm. and including supply and fixing of necessary screws, all materials,labour and T&P etc. required for proper complete. (OLD CSI No. 8.44)

130

-

-

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators,Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment).(CSI 10.11.1)

1950

-

-

... More
Renewing panes of 4.8 to 5.7 mm glass including supply of glass with putty and brads including supply of all materials, labour and t&P etc. required for proper completion of the work.(a) glass of 5 mm thick. (CSI No. 20.04)

104

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.( CSI 9.20.1)

78

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer- in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(CSI 12.50)

260

-

-

... More
Pre-Construction anti-termite treatment, by creating a barrier under and around the columns pits, foundation trenches, under floors, junctions of Walls & floors, around the external perimetre of building, expansion joints, surrounding of pipes and conduits etc. (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981))with Eldrine emulsifiable 0.2% concentration or any other approved material such as Heptachlore or chlordance will be used. The consumption of emulsion shall be (i) Foundation and masonary @ 5 Ltrs/Sqm, (ii) Back fills in immediate contact of foundation@ 7.5 Ltrs. / Sqm, (iii) Top surface of Plinth filling @ 5 Ltrs / Sqm, ( iv) Junction of walls & floors @ 7.5 Ltrs / Sqm, (v) Soil along external perimetre of building @ 7.5 Ltrs / Sqm (vi) under apron of the building @ 5 Ltrs. /Sqm. The rates includes cost of all materials, labour, equipments, T&P complete.(CSI 29.41)

520

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(CSI 13.80)

3250

-

-

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.(CSI 13.41.1)

1560

-

-

... More
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. (CSI 13.45.1)

1690

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (CSI13.62.1)

130

-

-

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.(CSI 15.60)

130

-

-

... More
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit concealed in wall, GP Box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 131-C)

104

-

-

... More
Wiring point for plug with 1 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit conceled in wall with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 134-C)

65

-

-

... More
Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit conceled in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 123-C)

39

-

-

... More
Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. (PWD 1139)

65

-

-

... More
Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia PVC conduit on surface, with one number 2.5 sq. mm. multistrand copper drawn in conduit complete in all respect. (PWD 216-C)

715

-

-

... More
Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.(CSI 29.135)

104

-

-

... More
Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI 29.133)

13

-

-

... More
Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.(OLD CSI No. 28.39)

26

-

-

... More
S/R of regulator for ceiling fan of GEC or equivalent make including cost of all labour material, T&P etc. required for proper completion of the work. ( CSI 22.60b)

26

-

-

... More
S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve. (PWD C.S.I. No. 1002-B)

78

-

-

... More
S&F of 100 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (PWD C.S.I. No. 378)

13

-

-

... More
Supply and fixing of LED street light fitting having dia cast aluminum body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 production complete in all respect. (PWD 1424)

26

-

-

... More
Supply and fixing 10sqmm alluminium cable required for proper complection of work.(NSI)

1040

-

-

... More
S&F of 40 Amp DP MCB (10 KA) C Curve. (PWD C.S.I. No. 1010-B)

13

-

-

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.). (CSI 10.18)

26

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.