If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Kanpur Electricity Supply Company Limited - KESCO Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date13 Mar 2024
Closing Date19 Mar 2024
Tender AmountRefer Documents
Costs
EMD
₹ 7,600Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KESCO_910164_2Bid Award Id
ViewTender No
52/Const./2023-24Tender Authority
Kanpur Electricity Supply Company Limited ViewPurchaser Address
-Website
http://https://kesco.co.in/wss/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Earthing Electrodes 3 mtr. long with 40 mm dia M.S. Round Bar making one end pointed upto 15 Cm.
3
-
-
Isolator Structure.
1
-
-
Neutral Support Structure.
1
-
-
Erection and grouting of following structures with 1:4:8 CC 25 mm brick ballast in required size in proper alignment and making plinth of all structure in 1:2:4 CC mix with 20 mm stone grit, 15 Cm ground level to smooth finish and its proper curing including cost of cement.
-
-
-
Post/Pin Insulator with E clamp in Post Insulator Structure/Cable Support Structure.
2
-
-
33 KV C.T/P.T
6
-
-
Pegging of 3 mtr. long Earth Electrodes 40 mm dia in to ground by hammering keeping its head 0.5mtr. below the ground level.
3
-
-
Laying of earthing strip of 50x6 mm M.S. Flat after cutting, bending, shaping and welding with earth electrodes with welding of 'U' Clamps on each electrodes and making proper joints overlapping with 40 cm each other it includes welding of riser from making earth mate to structure of both side.
3
-
-
Laying of 40 mm2 M.S. rod after cutting bending, shaping and welding with earth electrodes with welding of U clamps on each electrode and making proper joint overlapping 15 Cm each electrode for main earthmate.
30
-
-
Painting of following structure/equipment after rubbing and cleaning with Emery paper, coating with one coat of Red Oxide and two coat of grey enamel ISI marked paint with smooth finish including cost of paint and labour.
-
-
-
Post Insulator/L.A./C.T/P.T Structure.
3
-
-
Isolator Structure.
1
-
-
Cable Support Structure.
1
-
-
Busbar Gantry
1
-
-
Neutral Support Structure.
1
-
-
Loading, Carriage and unloading of following Material from Kesco. Store to site of work or work site to store including old & damage materials.
-
-
-
Battery set 24 volt 60 Ah (set of 15 cell) with charger.
1
-
-
33 KV L.A.
3
-
-
33 KV Isolator.
1
-
-
33 KV C.T/P.T
6
-
-
33 KV VCB.
2
-
-
33 KV Control relay panel.
1
-
-
11KV Switchgear Panel.
1
-
-
CT/PT junction box
1
-
-
Fitting of CT/PT junction box
1
-
-
Shifting of 11KV S/G Panel from unloading point to control room or control to loading point.
4
-
-
Erection of New 11kV switchgear panel in control room building in proper alignment, grouting of Anchor bolts matching of switchgear with each other matching of bus bar and related work and its earthing including cost of civil material.
4
-
-
Earthing of Panels at two points by MS Strip.
1
-
-
Testing and Comissioning of 11 KV Panel including internal wiring and connection.
1
-
-
Testing and Comissioning of 33 KV Control Relay Panel including internal wiring and connection.
1
-
-
Repairing of 33 kv VCB plinth suitable for new VCB
1
-
-
Dismetalling of 33KV VCB
1
-
-
Shifting of 33KV V.C.B. from unloading point to place of erection of 33KV switch yard and dismantling of its wooden packing.
2
-
-
Erection of 33KV VCB on erected structure with the help of crane in proper alignment and its all related work.
1
-
-
Shifting of 33 KV control relay panel from unloading point to control room.
1
-
-
Erection of 33 KV C/R Panel in control room building in proper alignment, grouting of Anchor Bolts, matching of base channel holes of switchgear and its all related work as grouting of panel and its earthing. It includes cost of civil material
1
-
-
Making all control cable connection in C.T., VCB mechanism, C.T. Junction Box, Transformer Control relay panel D.C. Battery Charger, ACDB Transformer indication board 11KV switchgear including proper termination ferruling and dressing with related work whichever is required including T/F work.
1
-
-
Construction of control cable RCC trench with stone pad as per standard specifications.
60
-
-
Laying of control cable in newly constructed cable trench and also in existing control cable trench.
250
-
-
Connecting of main earthing of control room & jointing with switch gear panel by welding of M.S. flat including required materials.
1
-
-
Filling of soil for leveling of S/S Switch yard as per site requirement.
50
-
-
Final leveling of yard and removal of wastage material and soil from switch yard.
1
-
-
Taking out 11 KV 3x300 Sq.mm XLPE Cable/ 11 KV 3x185 to 3x300 Sq.mm XLPE Cable from cable drum and then after transportation from store to work site or vice-versa.
150
-
-
Digging of Trench for laying of cable in different situations in size of 30 cm. wide and 1 to 1.5 meter deep.
-
-
-
In Normal soil
110
-
-
In kharanja soil
40
-
-
Laying of 33 KV/11KV 3x70 to 3x300mm2 XLPE cable in above digged trench covering with bricks and back filling and proper ramming.
150
-
-
Making indoor/outdoor joints of 33/11KV 3x50 to 3x300sqmm. Cable where the cable is being laid. Jointing Kit will be provided by the Department.
4
-
-
Mounting of cable box on pole, Cable support structure or 11 kV panel with handling of concerning cable and its proper fixing. (Without Pipe)
4
-
-
Loading carriage & unloading of main tank of 10 MVA, 33/11 KV power T/Falongwith radiators & its all accessories & material of following T/F from store to site of work or worksite to store in between 20 Km. distance.(2 crane)
1
-
-
Shifting of 10 MVA, 33/11 KV power T/F Tank Empty/filled by dragging or by crane of following running/damaged T/F from unloading point to plinth of T/F or from T/F plinth to shifting/loading point distance upto 25 meters and its placing in proper alignment on plinth of Transformer.(2 crane)
1
-
-
Erection of 10 MVA, 33/11 KV power T/F radiators, conservator tank vent pipe and all other accessories on main tank of following T/F including oil filling and all related work.(2 crane)
1
-
-
Earthing of T/F at three points by extending the existing M.S. Flat with main earthmate by welding.
1
-
-
Connecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.
1
-
-
Repairing of power T/F plinth suitable for 10 MVA with 1 : 6 CC Sand ratio, thereafter CC work on top in size of 3 x 3 x .25 Mtr. thereafter plastering all around the open portion.
1
-
-
Placing of 3 mtr. Long 2 No. rail pole on power T/F plinth during erection of power transformer.
1
-
-
T/F Flexible copper bond 30mm vide 30 Cm long & connecting with neutral support to T/F neutral bushing & proper tightening.
1
-
-
Providing and fabrication with fitting of copper busbar for making L connection for T/F Bushing .
7
-
-
Making jumpers from cable box to line, cable support switchgear panels, section poles of each phase.
2
-
-
Loading, Carriage and unloading of ACSR/ Panther Conductor from store to work site or vice-versa.
43.79
-
-
Erection of Lower Bus bar with ACSR Panther/DOG conductor
1
-
-
Supply of GI Pipe 40mm dia B-Class 80 feet long with socket cutter with loading unloading for power tf/ panel
5
-
-
Construction of DELTA using MS round BAR 3 MTR long 40 MM dia along with supply and required fabrication work with interconnection between MS bar
1
-
-
Boring and lowering of 80 feet G.I. Pipe along with all coupling and jointing required for each power transformer
5
-
-
Connecting of deep bore earthing 80 feet deep GI pipe to transformer body/neutral/ switch gear panel and Delta arrangement with the help of MS strip 50x6 mm by cutting ,shaping and welding including cost of material.
2
-
-
Carriage of all concerning stock material except mentioned above in items from Kesco. Store to site or vice-versa.
1
-
-