Kanpur Electricity Supply Company Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Kanpur Electricity Supply Company Limited - KESCO Tender
Eprocure
Opening Date19 May 2021
Closing Date8 Jun 2021
Tender Amount₹ 9,52,167 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 11,800Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_KESCO_587293_1Bid Award Id
ViewTender No
02/Const./2021-22Tender Authority
Kanpur Electricity Supply Company Limited ViewPurchaser Address
-Website
http://https://kesco.co.in/wss/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Repairing of damaged S.T. Pole by providing M.S. Angle 50x50x6mm, 3 Nos. each of 1 meter long by clamping at 2 points and its welding including its all related work.
2
-
-
Erection of repaired/new S.T. Pole size 9.0 Mtr. to 13.00 Mtr. including digging of Pit back filling and ramming.
6
-
-
Mounting of 33 KV, 11 KV & L.T. X-arm/bracket on the pole/rail.
10
-
-
Replacement of 33KV or 11KV pin insulator with G.I. Pin from damaged pole/ X-arm opening of binding from Insulator.
10
-
-
Repairing of 33 KV or 11KV damaged X-arm and proper shaping including drilling of holes whatsoever is required with the help of gas healing and welding.
6
-
-
Laying, stringing, tensioning & binding ACSR dog conductor for 3Ø 3 wire 33KV O.H. line.
300
-
-
Resagging/replacement of damaged/missing conductor from H.T./L.T. overhead line in Kanpur city.
-
-
-
Resagging of conductor on old/new line after replacement of damaged pole/erection of new pole/replacement of Disc Insulator and all related work.
4
-
-
Replacement of damaged disc insulator of disc insulator string after replacement of damaged insulators including, removing of conductor from disc fitting.
6
-
-
Fixing and grouting of stay rod including digging of pit, binding of stay wire and its all related work including cost of cement.
6
-
-
Earthing of support by sagging of M.S. earthing rod 20mm and connecting with earth wire and related work.
6
-
-
Laying of control cable including digging of trench and back filling.
100
-
-
Dismentalling of damaged 33 KV O/D Type C.T./P.T. from structure, dismentalling of wiring and earthing and its all related work.
4
-
-
Mounting of 33KV O/D Type C.T./P.T. on erected structure in proper position its wiring and earthing and its all related work.
4
-
-
Dismentalling of damaged 33KV Lightening arrestors from structure and its all related work as opening of clamps etc.
4
-
-
Mounting of 33KV Lightening arrestor on erected structure including its re-fabrication for matching holes, mounting in proper alignment itsearthing and its all related work as connecting to lower bus-bar.
4
-
-
Fabrication of earth electrode from 36mm/40mm M.S. Round bars 3 meter long making one end pointed upto 15cm. including cutting of round bar.
8
-
-
Erection of earth electrode 36mm/40mm by making pit of size 2’x2’ then pegging the earth electrodes with filling the pit with water and hammering the electrodes by hammer upto 0.5 meter proper below ground level.
4
-
-
Earhting of yard/structure/ S/G with M.S. Flat 50x6mm connecting with main Mate/Risers/Earth electrodes after its bending shaping and welding the strip.
20
-
-
Chopping of tree branches lying in the route of existing line touching the tree branches to the phase line conductor making fault to the feeder, for 3” to 18” dia or as per requirement of site.
20
-
-
Carriage of following stock materials from store to site of work as and when required or back to store from site (Old and damaged material):-
-
-
-
S.T. Pole 9.0 meter to 13.00 meter.
20
-
-
M.S. Rail 6.5 Mtrs. To 13.0mtr.
4
-
-
33KV Lightening arrestors
2
-
-
33KV C.T./P.T. Outdoor Type
2
-
-
33KV Bus/ Line Isolator
2
-
-
33KV Metering Cubical
2
-
-
11KV Switchgear Panel
2
-
-
33KV M.O.C.B/V.C.B./I.D. Panel
2
-
-
33KV Control Relay Panel
2
-
-
Repairing of 33 KV Old Isolator by replacing the jaws and blades or by oiling and greasing of moving parts or by adjustment of moving mechanism or by leveling the whichever is required for smooth operation of isolator and its all related work.
2
-
-
Dismentalling of old and damaged 33KV Isolator from structure by cutting the old bolts and nuts and removing all mechanism with the help of Gas Cutter. It includes removing of jumpers with Isolator clamps and all related work.
2
-
-
Erection of 33KV Isolator on erected Isolator structure in proper alignment fitting its complete moving mechanism its proper adjustment, leveling and oiling, greasing including cost of nuts and bolts what so ever required including any type of fabrication required for the work.
2
-
-
Dismentalling of old & damaged lower bus bar of Dog/Panther conductor, dismentalling of clamps connectors from all concerningequipments.
2
-
-
Dismentalling of old & damaged upper of ACSR Dog/Panther Conductor, Dismentalling of Disc Insulator string.
2
-
-
Fabrication of Busbar Gantry.
2
-
-
Erection & Grouting of Busbar Gantry.
2
-
-
Dismentalling of old/damaged existing 11KV S/G Panel including opening of internal connection.
2
-
-
Shifting of 11KV S/G New/Damaged Panels/Control relay panel from unloading point to C/R or C/R to loading point.
2
-
-
Erection of New/Old 11KV switchgear panel in control room building in proper alignment, grouting of Anchor bolts matching of switchgear with each other matching of bus bar and related work and its earthing including cost of cement and M.S. Flat.
2
-
-
Shifting of 33KV S/G Panel from unloading to C/R building at place of erection or place of erection to loading point.
2
-
-
Erection of new (Old 33KV) Indoor S/G Panel in control room building in proper alignment, grouting of Anchor Bolts, matching of base channel holes of switchgear and its all related work as grouting of panel and its earthing. It includes cost of cement and M.S. Flat.
2
-
-
Dismentalling of old/damaged existing 33KV S/G Panel including opening of internal connection.
2
-
-
Providing and fixing T/F indication board of size 10”x12” fitted with sunmica top, 5 Nos. Piano switch and 5 Nos. holders with bulbs make electric bell and it proper circuiting with diodes and all link terminal and its all related work.
2
-
-
Providing and fixing of flexible copper bond 30mm vide 30cm long and connecting with neutral support structure to T/F neutral bushing and proper tightening.
2
-
-
Erection of new lower bus-bar with ACSR Dog/Panther conductor from T/F 33KV Terminal to upper bus-bar connecting with all intermediate equipment and its all related work.
2
-
-
Making of 33KV M.O.C.B./V.C.B. plinth in size of 1.5x2.4x1.0 meter with brick work cement, sand ratio 1:6 making proper pockets for anchor bolts grouting its plastering alround with smooth finish including cost of cement.
2
-
-
Erection of new Upper Busbar with ACSR Dog/Panther Conductor including mounting of disc insulator string.
2
-
-
Making section in existing Upper Busbar with ACSR Dog/Panther Conductor for dual source supply including mounting of disc insulator string.
2
-
-
Shifting of 33KV M.O.C.B./V.C.B./M.C.B. from unloading point to place of erection of 33KV switch yard and dismentalling of its wooden packing of shifting of damaged equipments as above from plinth to loading point.
2
-
-
Erection and grouting of 33KV MOCB/VCB structure on MOCB/VCB plinth in 1:2:4 ratio with stone ballast.
2
-
-
Dismentalling of 33KV M.O.C.B./VCB from erected structure with the help of crane.
2
-
-
Erection of 33KV M.O.C.B./VCB on erected structure with the help of crane in proper alignment and its all related work.
2
-
-
Making all control cable connection in C.T., M.O.C.B./VCB mechanism, C.T. Junction Box, Transformer Control relay panel D.C. Battery Charger, ACDB Transformer indication board 11KV switchgear including proper termination ferruling and dressing with related work whichever is required.
2
-
-
Erection of 33KV metering cubicle/33KV control Relay Panel in control room in proper alignment including its earthing and related work.
2
-
-
Dismentalling of H.T./L.T. Jumpers from line to each phase.
16
-
-
Taking out 33/11KV XLPE/PILCA cable from drum/complete drum of cable from store its loading carriage and safe unloading by truck/bullock cart at site of work or from site to store.
200
-
-
Digging of Trench for laying of cable in different situations in size of 30 cm. wide and 1 to 1.5 meter deep.
-
-
-
In Normal soil
20
-
-
In Kharanja Road
16
-
-
In Metallic Road
16
-
-
In R.C.C. Road
16
-
-
Digging of Trench by boaring horizontally to cross the road and laying of C.I./M.S. Hume pipes in Boaring portion.
16
-
-
Laying of 33/11KV 3x50 to 3x400mm2 XLPE/PILCA cable in above digged trench covering with bricks and back filling and proper ramming.
100
-
-
Laying of Cable through trnech less method (HDD) including cost HDPE Pipe
10
-
-
Laying of Cable through trench less method
10
-
-
Laying, strininging, tensioning & final sagging of 33 KV XLPE Cable (Size 3x120 to 3x300 Sq.mm) pole to pole as O/H line.
20
-
-
Laying of cable in digged trench and also passing of this cable through C.I./M.S. hume pipe and balance portion covering with bricks and back filling.
10
-
-
Digging of trench in metallic/R.C.C. Road laying of hume pipe and its back filling including cost of hume pipe.
10
-
-
Digging of suitable pit for making joint of cable for straight through joints and to manage the cable jointer for above joint with complete meggering and all related work and covering the bricks and backfilling. The jointing kit will be provided by Dept. size total 1.5x4 meter and 2 meter deep.
4
-
-
Making indoor/outdoor joints of 33/11KV 3x50 to 3x300sqmm. Cable where the cable is being laid. Jointing Kit will be provided by the Department.
6
-
-
Dismentalling of connected cable box on pole/S/G Panel/Cable support structure.
6
-
-
Laying of G.I. Wire for Guarding including lacing as per standard specification.
200
-
-
Mounting of cable box on pole, S/G panel cable support structure with handling of concerning cable and its proper fixing.
6
-
-
Making jumpers from cable box to line, cable support switchgear panels, section poles of each phase.
10
-
-
Erection of Double Pole Structure by digging of Pit.
4
-
-
Making a double pole structure using single poleby digging of pit.
2
-
-
Erection of Tri- Pole structure by digging of pit.
2
-
-
Erection of Four Pole structure by digging of pit.
2
-
-
Fabrication/ Modification of MS Item as per requirement of site
100
-
-
Painting of Steel Tubular Poles after rubbing, cleaning with emery paper and coating one coat of redoxide on full length of pole and then two coat of Aluminium paint upto X-arm from top including cost of paint and redoxide paint used should be ISI mark Ist class enamel paint.
6
-
-
Making plinth of single pole of 400 mm dia, 600 mm height (200mm underground) with C.C. in ratio 1:4:8 of cements, stone ballast and coarse sand including cost of cement, stone & sand etc.
6
-
-
Grouting of pole with cement brick ballast and coarse sand as per standard specifications.
6
-
-
Digging of cable trench for taking out old/damaged XLPE/PILCA, 3x50 to 3x300sqmm 33/11KV cable & taking out the above Cable from digged trench and back filling of digged trench.
20
-
-
Repairing of road cutted for cable laying/taking out work with cement, coarse sand, and stone ballast, mortar with ratio 1:2:4 its proper ramming and curing in size as per site requirement.
15
-
-
Fabrication of following structure with M.S. Channel, M.S. Angle, M.S. Flat etc. in required size & length including cutting drilling, holes, welding and assembling.
-
-
-
Cable Support Structure
4
-
-
Neutral Support Structure
4
-
-
Fuse Set Unit
4
-
-
Erection and grouting of following structure with 1:4:8 C.C. 25mm brick ballast in required size as proper alignment and making plinth of all structure in 1:2:4 CC mix with 20mm stone grit, 15cm above ground level to smooth finish and proper curing including cost of cement.
-
-
-
Cable Support Structure
4
-
-
Neutral Support Structure
4
-
-
Fuse Set Unit
4
-
-
Painting of following structures after rubbing, cleaning with emery paper withIst class enamel paint.
-
-
-
Isolator Structure
4
-
-
Bus bar gantry structure
4
-
-
Cable support/LA/PI/Fuse set and other
4
-
-
Unloading of following power T/F main tank filled with oil, along with its all accessories like radiators, conservator tank T/F oil vent pipe etc. from Truck by crane and proper stacking.
-
-
-
10/8/6 MVA, 33/11/6.6 KV T/F
1
-
-
5/3/1.5 MVA, 33/11/6.6 KV T/F
1
-
-
Dismentalling of following power T/F including draining of T/F oil from radiators if necessary dismentalling of all accessories, as Radiators, vent pipe conservator Tank from main Tank of T/F (Either one or all) and its proper stacking.
-
-
-
10/8/6 MVA, 33/11/6.6 KV T/F
2
-
-
5/4/3 MVA, 33/11/6.6 KV T/F
2
-
-
10/8/6 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with 2 No crane
1
-
-
5/4/3 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with 2 No crane
1
-
-
Shifting of T/F Tank Empty/filled by dragging or by crane of following running/damaged T/F from unloading point to plinth of T/F or from T/F plinth to shifting/loading point distance upto 25 meters and its placing in proper alignment on plinth of Transformer.
-
-
-
10/8/6 MVA, 33/11/6.6 KV T/F
2
-
-
5/4 MVA, 33/11/6.6 KV T/F
2
-
-
10/8/6 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with 2 No crane
1
-
-
5/4/3 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with 2 No crane
1
-
-
3/1.5 MVA, 33/11/6.6 KV T/F
2
-
-
Loading carriage & unloading of main tank of T/F alongwith radiators &its all accessories & material of following T/F from store to site of work or worksite to store in between 20 Km. distance.
-
-
-
10/8/6 MVA, 33/11/6.6 KV T/F
2
-
-
5/4 MVA, 33/11/6.6 KV T/F
2
-
-
10/8/6 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with 2 No crane &trolla
1
-
-
5/4/3 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with 2 No crane &trolla
1
-
-
3/1.5 MVA, 33/11/6.6 KV T/F
2
-
-
Erection of radiators, conservator tank vent pipe and all other accessories on main tank of following T/F including oil filling and all related work.
-
-
-
10/8/6 MVA, 33/11/6.6 KV T/F
2
-
-
5/4/3 MVA, 33/11/6.6 KV T/F
2
-
-
10/8/6 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with 2 No crane
1
-
-
5/4/3 MVA, 33/11/6.6 KV T/F (BHEL/Heavy T/F) with 2 No crane
1
-
-
Dismentalling of earthing of running/damaged transformer at two points with the help of gas cutter.
4
-
-
Dismentalling and taking out the cable support structure by cutting with gas cutter for shifting of T/F including cutting of earthing of cable support structure wherever is required including its all related work.
4
-
-
Dismentalling and taking out the neutral support structure by cutting with gas cutter alongwith removing of flexible copper bond and its proper stacking.
2
-
-
Erection and welding of cable support structure with the help of welding including earthing of support in proper alignment and all related work.
2
-
-
Erection & welding of neutral support structure with the help of welding including earthing in proper alignment and all related work and fixing of flexible copper bond.
2
-
-
Earthing of T/F at two points by extending the existing M.S. Flat with main earthmate by welding.
2
-
-
Fabrication of neutral support structure with M.S. Angle and M.S. Flat.
4
-
-
Erection and grouting of neutral support structure with 1 : 4 : 8 CC ratio in proper alignment and plinth 15 Cm. above ground level and smooth finish.
4
-
-
Disconnecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.
10
-
-
Connecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.
10
-
-
Fabrication of isolator structure as per standard design.
2
-
-
Erection and grouting of Isolator structure in proper alignment and making plinth 15 Cm. above ground level with smooth finish.
2
-
-
Construction of power T/F plinth suitable for 5/10 MVA 33 KV T/F in size of 3 x 3 x 1.5 Mtr. Digging of pit in size of 3.5 x 3.5 x 1.2 Mtr. Of CC work at bottom in size of 3.5 x 3.5 x .15 Mtr. With ratio of 1:4:8 its proper ramming and curing thereafter brick work in size of 3 x 3 x 0.8 Mtr. with 1 : 6 CC Sand ratio, thereafter CC work on top in size of 3 x 3 x .25 Mtr. thereafter plastering all around the open portion, grouting of rail and M.S. Angle in top CC work and its proper curing.
2
-
-
T/F Flexible copper bond 30mm vide 30 Cm long & connecting with neutral support to T/F neutral bushing & proper tightening.
2
-
-
Providing of one jeep gang with T.& P on duty on special accessories.
2
-
-
Providing one padel gang with T.& P on duty on special accessories.
2
-
-
Loading carriage & unloading of Rail Pole Pcs. 3 Mtr. long from store to site for power Transformer.
2
-
-
Fitting of 3 Mtr. long Rail Pole on plinth under Power Transformer base.
2
-
-
Dismentalling and re-erection of Switch yard fencing, Piller, Ten set and others including civil work for proper stacking of power T/F.
2
-
-
Transportation charges of centrifuging machine to and fro for execution of work.
2
-
-
Providing of copper bus bar for making L for T/F bushing and fabrication & fitting of L connection and related work.
2
-
-
Transportation charges of T/F oil from store to site.
200
-
-
Centrifuging of T/F oil by centrifuging Machine.
400
-
-
Supply of 40 mm 'B' Class 60 ft. G.I. Pipe with Coppler& other related accessories.
2
-
-
Boaring 60 ft. and lowering down 'B' class 40 mm diaG.I. Pipe with coal connecting with Power T/F through 50x6 mm MS-Flat.
2
-
-
Fabrication, erection & grouting of fencing of switch yard with one side gate, welded fabricated wiremess 10 SWG with size 35x5 mm M.S. Flat X-Bracing & 40x40x6 MS Angle of frame size as per required of site (4 No.) and painting with synthetic 1st Class enamel bus green paint ISI Mark with the cost of all material.
1
-
-
Dismentalling of damaged ST Pole of very critical position with the help of crane after removing of all accessories from damaged pole and its related work including digging of pit or by cutting with gas cutter.
2
-
-