Jhansi Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Jhansi Development Authority - JDA Tender
Electrical and Electronics
Eprocure
Opening Date4 Nov 2022
Closing Date14 Nov 2022
Tender Amount₹ 12,10,873
Costs
EMD
₹ 24,220Document Cost
₹ 2,360Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_UPJDA_744896_1Bid Award Id
ViewTender No
1902/JDA/2022-23Tender Authority
Jhansi Development Authority ViewPurchaser Address
-Website
http://etender.up.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Writing point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sqmm. FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with 14 SWG copper earth continuity wire piano type switch & ceiling roase on 3mm thick Bakelite sheet etc. complete in all respect including matching color wash.As per S.I. No. 141 (C)
14
-
327
Wiring point for 5 amp. Plug with 141 (B) but in PVC conduit with 1.5 Sqmm. FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit. As per S.I. No. 141 @
24
-
327
Wiring point for call bell with 1.5 Sqmm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab along with reinforcement before concreting complete with 14 SWG copper earth continuity wire and piano type bell push or 2 pin socket etc. complete in all respect including matching color wash.As per S.I. No. 142 (C)
6
-
572
Wiring point for H.P.M.V./ Sodium Vapor lamp with 1.5 Sqmm FRLSH PVC insulated multistrand single core copper conductor in PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete in all respect including matching color wash. As per S.I. No. 143 (C)
8
-
840
Wiring point exhaust fan with 1.5 askew mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 14 SWG copper earth continuity wire , Piano type switch & ceiling roase on 3mm thick Bakelte sheet etc. complete in all respect including matching color wash.As per S.I. No. 144 (C)
8
-
893
Supply and fixing of power plug with 15A/250 volt flush switch and 5 pin 15A/250 volt flush type universal socket in suitable M.S. box of 1.75 mm X 50mm sixe with phenolic laminated bakelite sheet cover 3mm thick fixed with brass matching screw and cup washer. As per S.I. No. 1139
12
-
340
As in item no. 221(B) but in 20 mm dia heavy duty (2 mm thick) PVC conduit with one no. 2.5 sq. mm. FRLSH PVC insulated multistrandcopper conductor cable as earth continuitywire drawn in conduit. As per S.I. No. 221 (C)
260
-
149
Supply and wiring of submain in PVC insulated 1100 V grade single core copper conductor cable in heavy gauge rigid PVC counduit partly laid in slab along with reinforcement before concreting with 8 SWG GI earth continuity wire etc. complete in all respects. As per S.I. No. 222(C)
310
-
204
Supply and wiring of submain in PVC insulated 1100 V grade single core copper conductor cable in heavy gauge rigid PVC counduit partly laid in slab along with reinforcement before concreting with 8 SWG GI earth continuity wire etc. complete in all respect. As per S.I. No. 223 (C)
105
-
272
Supply and wiring submain with two number As in item No. 219 (B) but in 25mm dia heavy duty (2mm thick) PVC conduit with one number 10 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. As per S.I. No. 219(C)
60
-
399
Supply and fixing of single light wall bracket on matching M.D.F.E.G. Board base etc. complete in all respect.As per S.I. No. 412
8
-
1650
Supply and fixing of LED BULB. As per Market rate.
50
-
750
Supply and fixing of recess/ Surface/ Pendent mountinground 12 to 15 Watt LED Down Lighter havingPowder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respect. CAT-AAA. As per S.I. No. 1402
300
-
1350
Supply and fixing of 55 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with body with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect.As per S.I. No. 1407
22
-
7590
Supply and fixingof factory fabricatedM.S. box in existingsunk of size 600mm x 480mm x 200mm deep with Godrej type almirah, cover with handle etc. fabricated from 18 SWG (1.25mm) M.S. sheet duly painted with red oxide primer followedby two coats of synthetic enamel paint complete with necessary conduit entry and D.P./T.P.N.; fixingarrangementsand provisionfor compartmentfor loose wires openable housingon the top and hold fast etc. including supply of all material, labour, T&P etc. required for proper completionof the work.As per S.I. No. 1147
2
-
1720
Erection and testing of ceiling fan and regulator for room height upto 3.5 metres including supply of 3mm thick G.I.Pipe19mm dia. Duly painted, complete in all respect. As per S.I. No. 1116
14
-
140
S&F of 40 Amp. 4 pole MCB (10 KA). As per S.I. No. 1020
1
-
2275
Supply and fixing of polished MDFEG / Teak ply cover for surface type B.D.B. above 4 ways complete with 50mm hinges,aluminium kunda, chhapka and handle etc. complete in all respect. As per S.I. No. 1127
2
-
910
Supply and fixing of 16 gauge M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. As per S.I. No. 1122
2
-
810
Supply and fixing hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWG MS sheet incorporating 10mm dia. M.S. round bar duly bent for supporting fan hanger duly painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all material,labour, T&P etc. required for proper completion of the work. As per S.I. No. 1149
2
-
150
Construction of recess of 600mm x 480mm x 200mm size of main boards, distribution boards of all sizes including cutting of brick work, providing lintel of suitable size and thickness, plastering etc. with supply of all materials labour T&P required for proper completionof work. As per S.I. No. 1141 (B)
2
-
650
Earthing and lighting conductor supply and burrying 600mm X 600mm X 6mm G.I. pipe. Vertically for earthing with its top at least 3m. Below ground level complete with 20mm G.I. pipe and funnel for watering and two earthing leads of no. 8 to 10 SWG G.I. wire in 15mm dia G.I. pipe upto switch board ( from apron upto switch board the cost G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover, masonary housing alternate layers/ of charcoal cokeand salt at least 150 mm thick alround etc. complete in all respects. As per S.I. No. 705
2
-
10450
Supply and fixingof electronicfan regulator(Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.As per S.I. No. 1203(C)
14
-
517
S & F surface/Flush mounting 6ways VTPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge.As per S.I. No. 1027 (C)
2
-
9450
Supply and fixing of 240 Volts 'L' series miniature circuit breaker in exiting MCB, DB completed with connections as required. As per S.I. No. 1002
10
-
260
Supply and fixing of MCCB (16KA) Thernal Magnetic release. As per S.I. no. 1021
2
-
6300
S & F surface/Flush mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respect, as Direct by Engineer in Charge.As per S.I. No. 1025 (a)
2
-
2250
Supply of AC 230/250 Vlt5, 50 HZ ceiling fan with strandard down rod blades 2 Nos caps etc. complete (Make : bajaj/ Crompton Greavs) 1400mm sweep. As per Market Rate.
18
-
2500
Supply of AC 230/250 volts 50 HZ exhaust fan including providing nuts, bolts, mounting frame and other accessories etc. complete (Make : Bajaj/ Crompton Greavs). As per Market rate
4
-
2000
Providing and erection of stabilizer 4 KVA. As per Market Rate.
16
-
5500
Instalation Charges as required for completion of work. As per Market rate.
16
-
2000
Stand for oul door unit as required for completion of wall. As per Market rate.
16
-
1900
Providing and fixing of drain pipe complete. As per Market rate.
16
-
135
Supply and fixing of Refengrent copper pipe. As per Market rate.
16
-
750
Supply & laying of aluminium conductor, PVC insulated, served, sheeted cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface the cable run shall be fixed on M.S. clamp etc. of suitable size as per direction of Engineer-in-charge. complete in all respect the armouring of the cable shall be properly connected with the earth conductor by clamp etc. 150sqmm 3-1/2 core. As per S.I. No. 379(a)
50
-
957
S&F of 200 AMP four pole Mouled case type on laod on load change over switch with enclosure including the cost of labour, T & P and material reuired for proper completion of the work as per direction and satisfaction of Engineer an charge.As per S.I. No. 379(A)
2
-
10440