Irrigation Department Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Irrigation Department Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date10 Jan 2024
Closing DateCancelled
Tender Amount₹ 1,08,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand filling in plinth including supply of necessary quantity of local sand from a distance not exceeding 8 Kms from the site of work and including watering dressing etc. required for proper completion of work.as directed by the Engineer-in Charge up

11

-

-

... More
Providing and laying cement concrete in 1:4:8 (1 Cement : 4coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. In Foundation.as directed by the Engineer-in Charge up

22

-

-

... More
Providing and laying cement concrete in 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. In floors.as directed by the Engineer-in Charge up

12

-

-

... More
Providing and laying cement concrete in 1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) and curing complete, Including cost of form work.as directed by the Engineer-in Charge up

2

-

-

... More
RCC work Providing and laying in position specified grade of reinforced cement concrete in Raft foundation, including the cost of centering, shuttering, finishing and excluding reinforcement - All work up to plinth level in :1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) as directed by the Engineer-in Charge up

32

-

-

... More
RCC work Providing and laying in position specified grade of reinforced cement concrete,Slab including the cost of centering, shuttering, finishing and excluding reinforcement - Above plinth level upto fifth floor level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)as directed by the Engineer-in Charge up

47

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses, fillets, columns, pillars, piers,abutments, posts and struts etc. including cost of centering, shuttering, finishing and excluding reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)i) upto plinth level as directed by the Engineer-in Charge up

17

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. including cost of centering, shuttering, finishing and excluding reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)i) upto plinth level ii) Above plinth level upto fifth floor lable as directed by the Engineer-in Charge up

17

-

-

... More
Reinforced cement concrete work in beams,lintels suspended floors, roofs having balconies, shelves, chajjas, bands, staircases and spiral stair cases above plinth level up to floor five level, including the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20 mm nominal size) as directed by the Engineer-in Charge up

35

-

-

... More
Reinforment Steel TMT rebar including Bending, binding, cutting and placing of reinforcement including cost of binding wire but excluding cost of steel. as directed by the Engineer-in Charge up

26

-

-

... More
Providing and laying D.P.C 2.50 cm thick with Cement concrete Consisting of One Part Cement 1.5 part of Coarse Sand and three part of approved 10 mm graded Stone grit and including water proofing martreial as approved by the Engineer-In- Charge in the proportion as specified by manufacturer. as directed by the Engineer-in Charge up

1

-

-

... More
Painting on D.P.C. or Roof slab with two coats of air blown bitumen 60/70 or 80/100 1.7Kg/Sqm approximate including cost of fuel if an as directed by the Engineer-in Charge up

30

-

-

... More
Class-150 (Non Modular) brick work in 1:4 cement and Coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work upto plinth level as per directed by engineer incharge

52

-

-

... More
Class-150 (Non Modular) brick work in 1:4 cement and Coarse sand mortar in r super structure including supply of all materials, labour and T&P etc. required for proper completion of the work Above plinth level as per directed by engineer incharge

129

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.as directed by the Engineer-in Charge up

65

-

-

... More
Antitermite treatment of soil under floors using chemical emulsion @ one litre per hole,300mm apart@ 100 Nos Holes per 9.00 Sqm. including drilling 12 mm diameter holes and plugging also to match the floor properly :With Chlorpyriphos / Lindane E.C.20%with 1% concentration as directed by the Engineer-in Charge up

115

-

-

... More
Antitermite treatment of along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos / Lindane E.C. 20% with 1 % concentration As per IS 6313:2001 as directed by the Engineer-in Charge up

65

-

-

... More
12 mm thick plaster with cement and fine sand of 1.25 fineness modules in 1:4 over brick work, minimum thickness not to be less than 1cm including supply of all materials labour, tools & plants , proper curing etc required for proper completion of the work.as directed by the Engineer-in Charge up

1216

-

-

... More
6mm Celling plaster 1:3 (1 cement : 3 fine sand) cement & fine sand in F.M. not less than 1.25, 1:3 including chiping of RCC surface before ceiling plaster. The cost of including all material, labour T&P and scafolding etc. complete.as directed by the Engineer-in Charge up

292

-

-

... More
15mm Cement plaster with cement mortar in proportion of 1:4 cement & coarse sand of single coat for plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm. In girth and finished even and smooth.as directed by the Engineer-in Charge up

620

-

-

... More
Making drip course in sunshade or FACIA as per direction as Engineer-In-Charge including supply of all material, labour etc. required for proper completion of work. as directed by the Engineer-in Charge up

70

-

-

... More
Providing and laying "brick coba" 12mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreding cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cmX30cm and side wall parapet shall be mono tythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including supply of all material, labour, T&P etc complete for proper completion of workas directed by the Engineer-in Charge up

215

-

-

... More
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete with residual type petroleum bitumen of grade VG -10 as directed by the Engineer-in Charge up

215

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10 mm and down gauge),including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase.as directed by the Engineer-in Charge up

88

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter.as directed by the Engineer-in Charge up

30

-

-

... More
Finishing walls with POP approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work as directed by the Engineer-in Charge up

224

-

-

... More
Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work as directed by the Engineer-in Charge up

2128

-

-

... More
Distempering (first coat) with oil bound distemper of approved brand and manufacture and of required shade on undercoated wall surface to give an even shade over & including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shalimar, Asian, paints after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even with plaster of approved synthetic material and sand papered smooth including cost of all materials finished with two coat as directed by the Engineer-in Charge up

1508

-

-

... More
Finishing walls with exterior emulsion paint (Apex) of approved brand and manufacture and of required shade on undacorated wall surface to give even shade over @ 1.25 Ltr/10sqm including one coat of primer applid @ 0.75Ltr/10sqm coat curing and cost of all material, labour, T&P etc. required for proper completion of work.for two coat as directed by the Engineer-in Charge up

667

-

-

... More
C.P. teak wood wrought framed and fixed including simple mouldings, straight works as in Chaukhats, including supply of all materials, labour and T&P etc. required for proper completion of work.as directed by the Engineer-in Charge up

4

-

-

... More
Supply and fixing of 4.5cm (1.3/4") thick C.P. Teak wood part panelled & part glazed door and window shutters including supply of wooden cleats and stops and including fixing and adjustment of hinses, bolts, locks, handles, springs and/or other fitting but excluding their supply and including painting with two coats of Black Japan on all iron fittings if necessary & including fixing the glass panes with putty & brad. Glass to be 4mm thick. Fitting with necessary screws to be supplied departmently.For Fully Panelled Door as directed by the Engineer-in Charge up

42

-

-

... More
Supply and fixing of 4.5cm (1.3/4") thick C.P. Teak wood part panelled & part glazed door and window shutters including supply of wooden cleats and stops and including fixing and adjustment of hinses, bolts, locks, handles, springs and/or other fitting but excluding their supply and including painting with two coats of Black Japan on all iron fittings if necessary & including fixing the glass panes with putty & brad. Glass to be 4mm thick. Fitting with necessary screws to be supplied departmently.For Fully Glazed window as directed by the Engineer-in Charge up

37

-

-

... More
Supply and fixing of 4cm (3/2") thick C.P. Teak wood door and window shutters with panels of heavy quality galvanized iron wire gauge 2.5mm or 2mm or 1.5mm (1/10 or 1/12 or 1/6 inch) mesh or any other size with necessary beading including supply and fixing of wooden cleats and stops and including fixing and adjustment of hinses, bolts, locks, handles, springs and/or other fitting but excluding their supply and including painting with two coats of Black Japan on all iron fittings if necessary. Fitting with necessary screws to be supplied departmently as directed by the Engineer-in Charge up

60

-

-

... More
Providing and fixing 32 mm thick ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.including ISI marked Stainless Steel butt hinges with necessary screws, Steel Handels, Siliding bolt, Door Stopper and tower bolt.as directed by the Engineer-in Charge up

18

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessaryaccessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). as directed by the Engineer-in Charge up

3384

-

-

... More
Applying priming coat over new woodan surface upto 10cm. In width or girth or small not exceeding 0.10 Sq.M. area after and including preparing the surface by thoroughly clearing oil, grease, dirt and other foreign matter and scoured with wire brushed, fine steel/wood. Scrapper, sand papering and knotting including cost of all materials, labour T&P etc. required for proper completion of work as directed by the Engineer-in Charge up

119

-

-

... More
Sprit polish including sand paperings cleaning the surface properly and then applying the sprit polish colour with shining finishing supply of all labour material and T&P required for proper completion of work.(a) New Surface as directed by the Engineer-in Charge up

193

-

-

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) as directed by the Engineer-in Charge up

65

-

-

... More
Providing and laying Vitrified tiles in floor with lean concrete of 600X600 mm sizes (thickness 10mm), with a water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in desired colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, including grouting of joints. including preparation of 75mm thick base with concrete 1:4:8 Cement, Coarse sand and 40 mm B/B complete as per Engineer -In -Charge.

266

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. as directed by the Engineer-in Charge up

41

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.as directed by the Engineer-in Charge up

190

-

-

... More
Providing and fixing 18 mm thick Granite (gang saw cut), mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Slab area upto 0.50 Sq.M.)as directed by the Engineer-in Charge up

100

-

-

... More
Providing edge maulding to 18mm thick Granite stone, including machine polishing to edge to give hige gloss finish etc. complete as per design approved by Engineer-in-Charge.

161

-

-

... More
Supply and fixing hexagonal/ Round G.P Fan Box of approved make made up of 1.0 mm thick I.S.I marked G.P Sheet spot welded four to eight holes of 25.4 mm for pipe entry of the Box. Holes Should be semi- Shuttered type widh 0.5 mm G.P Sheet made uper and lower cover duly Screwed Fitted widh 300 mm round zink coated M.S bar x 12 mm & brand name should be embossed . Fixing with wiring conduit laid in the R.C.C Roof be four concreting along wuth supply of all matereal, labour, T&P etc. required for proper completion of the work. As per SI No. 1149 as directed by the Engineer-in Charge up

16

-

-

... More
Supply and laying of 25 mm dia heavey duty 2 mm thick P.V.C conduit complete with bends and other acessores as required in slab along with reinforcement, before concreting etc complete in all respect. As per SI No. 282A as directed by the Engineer-in Charge up

600

-

-

... More
Providing and fixing white Vitreous china wash basin 550x400 with C.I. brackets, 15mm dia CP brass single hole basin mixer of approved quality and make, including painting of fitting brackets , cutting and making good the walls. as directed by the Engineer-in Charge up

8

-

-

... More
Providing and fixing Stainless steel A ISI 304 (18/8) Kitchen sink without drain board size 610x510mm bowl depth 200mm as per IS: 13983 with CI brackets and stainless steel plug 40mm including painting of fitting and brackets Kitchen sink with drain board i) 510x1040 mm bowl depth 250 mm as directed by the Engineer-in Charge up

4

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, (Approved make Hindware and Jaquar) with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid

4

-

-

... More
Providing and fixing Polyethelene- Aluminium-Polyethelene Composite pressure pipes 25mm dia confirming IS -15450.UV stabilized with carbon black having thermal stability for hot and cold water supply capable to withstand temprature upto 80 degree. including all special fittings of composite material. all complete as per direction of Engg.-In-charge.

240

-

-

... More
Providing and fixing Polyethelene- Aluminium-Polyethelene Composite pressure pipes 32mm dia confirming IS -15450.UV stabilized with carbon black having thermal stability for hot and cold water supply capable to withstand temprature upto 80 degree. including all special fittings of composite material. all complete as per direction of Engg.-In-charge.

560

-

-

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.as directed by the Engineer-in Charge up

8

-

-

... More
Providing and fixing soil, waiste and vent pipes: Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 100 mm dia as directed by the Engineer-in Charge up

120

-

-

... More
Providing and fixing chrome plated (CP) stop cock of Jaquar/hindware/somany complete best quality as directed by the Engineer-in Charge up

24

-

-

... More
Providing and fixing chrome plated (CP) piller cock of Jaquar/hindware/somany complete best qualityas directed by the Engineer-in Charge up

24

-

-

... More
Providing and fixing chrome plated (CP) sink cock of Jaquar/hindware/somany complete best quality as directed by the Engineer-in Charge up

8

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.as directed by the Engineer-in Charge up

2

-

-

... More
Providing, laying and jointing glazed stoneware pipes 100 mm dia class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :as directed by the Engineer-in Charge up

50

-

-

... More
Providing, laying and jointing glazed stoneware pipes 150 mm dia class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :

50

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design :Inside size 1200 x 1200mm and 1.20 meter deep including C.I. Cover frame.as directed by the Engineer-in Charge up

2

-

-

... More
Providing and fixing S.W. intercepting trap 100mm dia in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1fine sand) including testing of joints etc. complete :as directed by the Engineer-in Charge up

8

-

-

... More
Providing and fixing S.W. intercepting trap 100mm dia in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1fine sand) including testing of joints etc. complete :as directed by the Engineer-in Charge up

8

-

-

... More
Supply and hoisting of sintex or equivalent high density polyethelene seamless of piece moulded tanks and placing the same in proper position including all taxes including labour and tools and plants etc. for proper completion of work. Tank should be ISI marked. as directed by the Engineer-in Charge up

400

-

-

... More
Providing and fixing GI pipe 32 mm dia Nominal bore complete with GI fitting as directed by the Engineer-in Charge up

70

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 as directed by the Engineer-in Charge up

8

-

-

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: i) 100 mm diameter as directed by the Engineer-in Charge up

8

-

-

... More
Providing and fixing Stainless Steel grating of approved quality and colour. 125 mm dia as directed by the Engineer-in Charge up

32

-

-

... More
Wiring point for fan with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface complete with 14 SWG copper earth continuity wire, piano type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc, complete in all respect as directed by the Engineer-in Charge up

16

-

-

... More
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface, complete with 14 SWG copper earth continuity wire,GPBox ,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed .

120

-

-

... More
Wiring Point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface,complete with 14 SWG copper earth continuity wire , GP Box and piano type switch and socket etc. complete in all respect

16

-

-

... More
Wiring point for exhaust fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface complete with14 SWG copper earth continuity wire, 15 A piano type switch & ceiling rose on 3 mm.thick phenolic laminated backelite sheet etc, complete in all respect.

12

-

-

... More
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thickAluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification,Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms),Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.6.4.1 48" Sweep 5 Star (1200 mm) as directed by the Engineer-in Charge up

16

-

-

... More
Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.as directed by the Engineer-in Charge up

12

-

-

... More
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way SP & N as directed by the Engineer-in Charge up

8

-

-

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module as directed by the Engineer-in Charge up

32

-

-

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module as directed by the Engineer-in Charge up

40

-

-

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module as directed by the Engineer-in Charge up

32

-

-

... More
Supply and fixing of batten / angle holder complete in all respect as directed by the Engineer-in Charge up

32

-

-

... More
Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition.LED square or round down light 10-12W as directed by the Engineer-in Charge up

120

-

-

... More
Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W as directed by the Engineer-in Charge up

40

-

-

... More
Supplying and fixing of solar Lux level street light control switch single phase including suitable capacity contactor. 3 kW as directed by the Engineer-in Charge up

4

-

-

... More
Supply+ and fixing of 14 SWG copper wire along with conduit pipe duly bound with earthclops as directed at site by Engineer in charge with supply of all the material labour and T&P etc required for proper completion of work as directed by the Engineer-in Charge up

2880

-

-

... More
Supply+ and fixing of t 10 SWG Copper Wire along with conduit pipe duly bound with earthclops as directed at site by Engineer in charge with supply of all the material labour and T&P etc required for proper completion of work as directed by the Engineer-in Charge up

720

-

-

... More
Supply and fixing of switch box 100 x100x 50 mm size of approved make made up of 1.0 mm thick ISI Marked G.P.sheet All 4 corners folded & spot welded for screw and holes plugged with PVC Nylon Caps . Two or more holesfor pipe entry of 25.4 mm on upper and lower sides of thebox. Holes shuld be semi-shuttered type and fitted with heavy brass Earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge.

40

-

-

... More
Supply and fixing of switch box e 175 x 100 x 65 mm size of approved make made up of 1.0 mm thick ISI Marked G.P.sheet All 4 corners folded & spot welded for screw holes plugged with PVC Nylon Caps . Two or more holesfor pipe entry of 25.4 mm on upper and lower sides of thebox. Holes shuld be semi-shuttered type and fitted with heavy brass Earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge.

48

-

-

... More
Supply and fixing of switch box 150 x 150 x 65 mm size of approved make made up of 1.0 mm thick ISI Marked G.P.sheet All 4 corners folded & spot welded for screw holes plugged with PVC Nylon Caps . Two or more holesfor pipe entry of 25.4 mm on upper and lower sides of thebox. Holes shuld be semi-shuttered type and fitted with heavy brass Earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge.

48

-

-

... More
Supplying and fixing one of 230 V bell or buzzer and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws.as directed by the Engineer-in Charge up

4

-

-

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism 125 A 25 kA as directed by the Engineer-in Charge up

1

-

-

... More
Supplying and fixing of Shunt trip suitable for MCCB.CBCT as directed by the Engineer-in Charge up

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.