Indian Oil Adani Gas Private Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Indian Oil Adani Gas Private Limited - IOAGPL Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date6 Jul 2024
Closing Date22 Jul 2024
Tender AmountRefer Documents
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AGPL_200540_1Bid Award Id
ViewTender No
IOAGPL/PCP/OPEN/2024-25/29Tender Authority
Indian Oil Adani Gas Private Limited ViewPurchaser Address
-Website
http://https://ioagpl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply of various items as listed below for PCP jobs as per technical scopes and specifications mentioned in tender documents.
-
-
-
Supply of AC Operated CPTR Unit - Automatic Controlled, RMU and GPS based current interrupter timer facility, 35V/25A or 48V/25A, Automatic, Air cooled, Indoor type with remote montioring and control through SCADA facility as per IOAGPL specification/tender document.
2
-
-
Supply of 1" dia & 1 M long 8A rating LIDA MMO anode sets for Deepwell anode ground bed (Each set consist of 10 Nos. of anode) with petroleum cock breeze, anode cable & cable joints etc.
2
-
-
Junction Boxes
-
-
-
Supply of Anode Junction Box containing necessary shunt & resistor (IOAGPL Approved data sheet) having degree of protection IP‐55 (IP-55, Weather Proof)
2
-
-
Supply of Cathode Junction Box containing necessary shunt & resistor (IOAGPL Approved data sheet) having degree of protection IP‐55 (IP-55, Weather Proof)
2
-
-
Permanent Reference Cell
-
-
-
Cu/CuSO4 Permanent Reference cell
15
-
-
Ag/AgCl Permanent Reference cell (Shall be used only if required based on survey report)
2
-
-
Supply of PCP Cables- The Cables shall be annealed high conductivity, stranded copper conductor, 650/1100V grade, XLPE Insulated & PVC Sheathed
-
-
-
1c x 6 mm2 - armoured for potential measurement, Ref Cell etc.
500
-
-
1Cx 25 mm2- armoured for Bonding/Grounding etc.
300
-
-
1Cx 35 mm2- armoured for Anode & Cathode Header Cable etc.
300
-
-
3C X 10mm2- armoured for TR/CPPSM unit incomer cable etc.
250
-
-
1C X 10mm2- armoured cable
250
-
-
Supply of ER probes at site
2
-
-
Supply of ER probe Readers
1
-
-
Supply of Polarisation coupons (100 mmx100mm) with Magnetic reed switch, Pipe piece will be provided by IOAGPL
8
-
-
Supply of Solid State type Polorisation cells for HT power line crossings (66KV & above)
10
-
-
Supply of Surge Diverter for IJ
15
-
-
20 Kg Sacrifical Zinc anodes for HT line crossing, Earthing of block valves on Cathodically Protected portion of pipeline
10
-
-
Earthing Electrodes 65mm dia x 3mtr long & 4.5 mm thick GI pipe for earthing of cathodically inprotected pipeline
15
-
-
Test Stations (Weather Proof with IP-55)
-
-
-
Normal Size as per tender drawings - Supply of Test Station (TLP) Box Type A/B/C/D/E/I etc. weatherproof as per IOAGPL approved data sheet/drawing
10
-
-
Big Size suitable for Polarisation Cells - Supply of Big Size (HT Line/ Bonding)Test Station weatherproof as per IOAGPL approved data sheet and drawings
5
-
-
Supply of Thermit welding/CAD kit for Cable to pipe connections by Thermit welding method for all sizes all cable sizes including encapsulation
20
-
-
Supply of Cable to pipe connections by Pin brazing method for all sizes all cable sizes including encapsulation
30
-
-
Supply of Recommanded Spares for 2 Years Operation & Maintenance of CP system as per spare list enclosed in Vol. II of II (Technical
Specification)
1
-
-
Supply of Cable Route Marker
15
-
-
PCP-SERVICE
-
-
-
Installation, Testing & Commissioning (ITC) of below items for PCP system
-
-
-
This includes, all civil works, structural works, electrical works, earthing, cable connections, sand paddings, brick works, repair works, painting works and all other allied works required for installation, testing and commissioning of PCP System.
-
-
-
Soil Resistivity Survey at PCP anode ground bed Locations along with soil chemical analysis (per location)
2
-
-
Erection, Installation, Testing & Commissioning of AC Operated CPTR Unit - Automatic Controlled, RMU and GPS based current interrupter timer facility, Min 35V/25A or 48V/25A Automatic, Air cooled, Indoor type with remote montioring and control through SCADA facility as per IOAGPL specification/tender document. inclduing construction of civil foundation, if required, for CPTR Unit.
2
-
-
Deepwell anode groundbeds consisiting of 1" Dia x 1M long 8Amp Rating Lida Single (MMO) Electrode sets including cutting trench & backfill with Petroleum Cokebreeze or Drilling of borehole, lowering of MS Casing pipe & PVC pipe with petroleum coke breeze backfill and anode tail cable laying etc as required to complete the installation of the AGB in all respect including all civil restoration
2
-
-
ITC of Junction Boxes
-
-
-
Anode Junction Box containing necessary shunt & resistor (IOAGPL Approved data sheet) having degree of protection IP‐55 (IP-55, Weather Proof)
2
-
-
Cathode Junction Box containing necessary shunt & resistor (IOAGPL Approved data sheet) having degree of protection IP‐55 (IP-55, Weather Proof)
2
-
-
ITC of Permanent Reference Cell
-
-
-
Cu/CuSO4 Permanent Reference cell
15
-
-
Ag/AgCl Permanent Reference cell (Shall be used only if required based on survey report)
2
-
-
ITC of of PCP Cables- The Cables shall be annealed high conductivity, stranded copper conductor, 650/1100V grade, XLPE Insulated & PVC Sheathed
-
-
-
1c x 6 mm2 - armoured for potential measurement, Ref Cell etc.
500
-
-
1Cx 25 mm2- armoured for Bonding/Grounding etc.
300
-
-
1Cx 35 mm2- armoured for Anode & Cathode Header Cable etc.
300
-
-
3C X 10mm2- armoured for TR/CPPSM unit incomer cable etc.
250
-
-
1C X 10mm2- armoured cable
250
-
-
ITC of ER probes
2
-
-
ITC of Polarisation coupons (100 mmx100mm) with Magnetic reed switch, Pipe piece will be provided by IOAGPL
8
-
-
ITC of Solid State type Polorisation cells for HT power line crossings (66KV & above)
10
-
-
ITC of Surge Diverter for IJ
15
-
-
ITC 20 Kg Sacrifical Zinc anodes for HT line crossing, Earthing of block valves on Cathodically Protected portion of pipeline
10
-
-
ITC Earthing Electrodes 65mm dia x 3mtr long & 4.5 mm thick GI pipe for earthing of cathodically inprotected pipeline
15
-
-
ITC of Test Stations (Weather Proof with IP-55)
-
-
-
Providing shed of suitable size (minimum 3mX3m) with 75X75X5mm angles and FRP sheet for TR unit installaed outdoor including all civil works for foundation and grouting of poles
2
-
-
Cable to pipe connections by Pin brazing / Thermit welding method for all sizes all cable sizes including encapsulation
50
-
-
Intallation, Painting and lettering of Cable Route Marker
15
-
-
Repair of damaged 3LPE with approved compatible sleeve/epoxy including excavation & restoration (per location)
10
-
-
Cleaning, Painting, Numbering and Installation of circuit diagram plate for existing TLP boxes
65
-
-
Post Commissioning Surveys and submission of drawings/reports/dcouments
-
-
-
CIPL Survey
44000
-
-
Current Attenuation Test Survey (CAT)
44000
-
-
CAT with "A" Frame or DCVG Survey at Holiday / Defect Location
10000
-
-
AC-DC Interference Detection and Mitigation of entire network
1
-
-
Monitoring and maintenance of PCP system once a Month till Handing Over for six months from date of Commissioning.
6
-
-
Flame proof Big Size suitable for Polarisation Cell & Insulation joint connection
-
-
-
Supply of Big Size (HT Line/ Bonding/IJ)Test Station flameproof as per IOAGPL approved data sheet and drawings
1
-
-
ITC of Big Size (HT Line/ Bonding/IJ)Test Station flameproof as per IOAGPL approved data sheet and drawings
1
-
-