Indian Institute Of Toxicology Research Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Indian Institute Of Toxicology Research - IITR Tender
Eprocure
Opening Date12 Oct 2019
Closing Date30 Oct 2019
Tender Amount₹ 91,78,901
Costs
EMD
₹ 1,83,580Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Supply, Installation, Testing And Commissioning Of Vrv/vrf Airconditioning System
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_CSIR_33759_1Bid Award Id
ViewTender No
IITR/EMe-17(13)/2013Tender Authority
Indian Institute Of Toxicology Research ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(i) 40 HP ODU Heat Pump having minimum 02 Nos. of scroll compressors.
1
-
-
(ii)44 HP ODU Heat Pump having minimum 02 Nos. of scroll compressors.
2
-
-
(iii) 50 HP ODU Heat Pump having minimum 02 Nos. of scroll compressors.
1
-
-
Floor wise details of capacity of ODUs to be installed:
-
-
-
Ground Floor: 40 HP having minimum two Nos. of compressors
-
-
-
First Floor: 44 HP having minimum two Nos. of compressors
-
-
-
Second Floor: 44 HP having minimum two Nos. of compressors
-
-
-
Third Floor: 50 HP having minimum two Nos. of compressors
-
-
-
Make : Diakin/Voltas/LG/Mitsubhishi/O General/Carrier/Blue Star/Hitachi/Toshiba
-
-
-
Supply,installation,testing and commissioning of following type indoor units for VRV/VRF air conditioning system with cordless remote and :Make of indoor units: same as outdoor units as per Sl No.1.
-
-
-
(B) Indoor Units:
-
-
-
(i) 1.0 TR capacity 4 way cassette AC with grill (2'x2' panel)and wireless remote
2
-
-
(ii) 1.2 TR capacity 4 way cassette AC with grill (2'x2')and wireless remote
5
-
-
(iii) 1.5 TR capacity 4 way cassette AC with grill (2'x2' panel) and wireless remote.
12
-
-
(iv)2.0 TR capacity 4 way cassette AC with grill (3'x3' panel)and wireless remote
8
-
-
(v) 2.5 TR capacity 4 way cassette AC with grill (3'x3' panel)and wireless remote
21
-
-
(vi) 3.0 TR capacity 4 way cassette AC with grill (3'x3' panel)and wireless remote
13
-
-
(vii) 4.0 TR capacity 4 way cassette AC with grill (3'x3' panel)and wireless remote
2
-
-
Supply,installation,testing and commissioning of Refnut/Y-joints of required size for the following:
-
-
-
(a) For IDUs to IDUs
59
-
-
(b) For ODUs to ODUs
4
-
-
Suply and installation of following size copper refrigerant piping duly insulated with closed cell elastomericnitrile insulation of 19/13 mm thickeness including all clamps, holders and threaded hangers etc complete as required: Make: Rajco/Mandev/Mettube/Hariom/Totaline/Hitachi.
-
-
-
(i) 6.35 mm dia
40
-
-
(ii) 9.52 mm dia
90
-
-
(iii) 12.7 mm dia
90
-
-
(iv) 15.88 mm dia
120
-
-
(v)19.05 mm dia
150
-
-
(vi) 22.2 mm dia
100
-
-
(vii)25.4 mm dia
120
-
-
(viii) 28.58 mm dia
80
-
-
(ix) 31.4 mm dia
72
-
-
(x) 34.9 mm dia
80
-
-
(xi) 38.1 mm dia
42
-
-
(xii) 41.3 mm dia
60
-
-
(xiii) 44.5 mm dia
60
-
-
Supply and installation of following size hard pvc insulated drain water pipe with 6 mm nitrile rubber insulation and with all fittings and accessories.Make: Kisan/Finolex/Supreme/Prakash
-
-
-
(i) 32 mm dia
300
-
-
(ii) 50 mm dia.
200
-
-
Supply and fixing of M S angle iron base frame of suitable size and strength for installing 2 Nos. of 44 Hp, 1 No. 40 HP and 1 No. of 50 HP capacity VRV/VRF out door units on roof top including preparation of a suitable size pcc plateform on roof top etc complete with grouting the angle iron base frame etc and painting of angle iron frame complete work as required.
4
-
-
Supply and laying of pvc insulated following size control cum transmission sheilded copper conductor cable between each indoor and out door in medium class pvc conduit on surface complete as required.Wire: Havells/Anchor/Finolex/Polycab/RR Kabel .PVC Conduit: Cap/AKG/BEC.
-
-
-
(i) 2Cx1.5 sq mm
750
-
-
Supply,fixing and hanging of slotted angle GI channel with the help of GI threaded hanger rod from ceiling including nuts and bolts for laying all copper refrigerant piping,power electrical cables,communication cables and pvc drain pipes btween indoor units, between out door and indoor units and from DB to each indoor and out door units complete with laying of drain water piping from each indoor unit upto drain point alongwith all accessories complete work as required.
500
-
-
Supply and laying of following size perforated GI cable tray on surface/ hanging from ceiling as per site requirement along with threaded GI hangers, nuts and bolts including covering its terrace portion from top with GI sheet the complete as required:
-
-
-
(i) 450mmx50mmx1.6 mm
60
-
-
(ii) 300mmx50mmx1.6 mm
200
-
-
Supply and laying of following size pvc insulated/xlpe copper conductor 1.1 KV grade armoured cable in existing cable tray/on surface as required.Make: Finolex/Havells/Polycab/Kalinga/Gloster/ISI
-
-
-
(i) 5 Corex16 sqmm
110
-
-
(ii) 5 Corex10 sqmm
60
-
-
Design,fabrication,supply,installation & commissioning of cubicle type electrical panel board of required size made out of 16 SWG, CRCA sheet with powder coated paint having 400Amp rating four strip aluminium busbar fitted with 3 Nos. phase indicating LED panel indicators and with follwing rating Incomer and out going switch grears as required: Incomer: 415V,AC,315/320A, FPMCCB of 35KA breaking capacity : 1 No. Outgoing: FP MCCB,415V,AC, 125A, 25KA breaking capacity : 6.0 Nos. Make: Switch Gear: L&T/Seimens/GE/ABB/Indo Asian/Havells.
2
-
-
Supply of following size PVC insulated pvc sheathed /XLPE aluminium conductor 1.1 KV grade armoured power cable. Make: Havells/Polycab/Kalinga/Gloster/
-
-
-
(i) 3x1/2x70 sqmm
100
-
-
Supply of following size PVC insulated pvc sheathed /XLPE aluminium conductor 1.1 KV grade armoured power cable. Make: Havells/Polycab/Kalinga/Gloster .
-
-
-
(i) 3x1/2x25 sq mm
120
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. Make:Havells/Indo Asian
-
-
-
(i) 4 way (4+12), Double Door
8
-
-
Supply and laying of following size pvc insulated FRLS copper conductor single core cable in medium class pvc conduit on surface complete as required. Wire: Havells/Anchor/Finolex/Polycab/RR Kabel/ISI .PVC Conduit: Cap/AKG/BEC.
-
-
-
(i) 3x2.5 sq mm
792
-
-
Providing and fixing of following size FRLS copper wire on surface or in recess for loop earthing as required.
-
-
-
(i) 4 mm dia.
100
-
-
Laying and fixing of one number pvc insulated and pvc sheathed/xlpe power cable of 1.1 KV grade of following size on wall surface as required:
-
-
-
(i) Upto 35 sq mm
120
-
-
(ii) Above 35 sqmm and upto 95 sqmm
100
-
-
Supplying and making indoor end terminations with bras compression gland and aluminium lugs for fo;;owing size of pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 KV grade as required.
-
-
-
(i) 3.5x25 sq mm
16
-
-
(ii) 3.5x70 sq mm
4
-
-
Supplying & fixing of 6 A to 32 A rating 230V,10KA C curve MCBssuitable for inductive load of following pole in the existing MCB,DB complete with connections,testing & commissioning etc as required: Make: L&T/Seimens/GE/ABB/Indo Asian/Havells.
-
-
-
(i) Single pole
96
-
-
Providing & fixing following rating and breaking capacity and pole MCCB with thrmmagnetic release and terminal spredars in existing cubicle panel board icluding drilling holes in cubicle panel and making connections etc as required: Make: L&T/Seimens/GE/ABB/Indo Asian/Havells.
-
-
-
(i) 125 Amp,16 KA,TP,MCCB.
8
-
-
Less dismantling and removal of old existing GI, A/C duct and its fixtures from all floors of the building and buy back cost of salvage value of these dismantled items including removal of dismantled items from site complete with required labour, tools and plants complete work as required.
1
-
-
Total: Sub Head-I (Add Item 1 to Item20-Item21)
-
-
-
Sub Head-II
-
-
-
Comprehensive AMC of complete VRV/VRF air conditioning system installed by the contractor as given under Sub Head-I above including repair and maintenance of IDUs & ODUs, compressor,refrigerant copper piping, electrical wiring, PCBs, electronic solenoid valves, refilling of refrigerant gas and all other associated equipments/components of the VRV/VRF airconditioning system after completion of defect liability period of one year from the date of completion and handing over of above A/C sytem to department for its purposeful use.
-
-
-
(i) For the first one year period after completion of defect liability period
1
-
-
(ii)For the second one year period after completion of defect liability period
1
-
-
Total: Sub Head-II (Item No 1(i) + Item No 1(ii) )
-
-
-
Grand Total: Sub Head-I + Sub Head-II
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements