Indian Institute Of Technology Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Indian Institute Of Technology - IIT Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date30 Nov 2024
Closing Date23 Dec 2024
Tender Amount₹ 2,05,86,555
Costs
EMD
₹ 4,11,731Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IITK_837474_1Tender No
27/EE/Elect/2024Tender Authority
Indian Institute Of Technology ViewPurchaser Address
-Website
http://https://www.iitk.ac.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
UPS system shall have rated Output Power Factor-1 (80kVA @80kW)
-
-
-
UPS shall carry design output at 40 deg. Crest factor 3:1,
-
-
-
Output THD is less than 3% for full linear load & Less than 5 % for nonlinear load.
-
-
-
Overload 125% for 10 min, 150% for 1 min and should be able to operate continuously at 115% load on bypass mode. Very High online double conversion efficiency up to 96%.
-
-
-
Inbuilt Delta - Star Isolation Transformer at Input of UPS System covering Online as well as bypass path, before rectifier and not at the inverter output . No deviation in this regard shall be acceptable. SLD showing Isolation Transformer position, signed and stamped on OEM's letter head to be submitted by the vendor as part of TDS submission for getting manufacturing clearance.
-
-
-
Parallel communication port, RS232, USB, EPO and SNMP interface, BMS interface, Dust Filter at Air Inlet point are required.
-
-
-
LCD Display indicating all important parameters
-
-
-
To improve the UPS Security over LAN/WAN the SNMP card provided with UPS shall be having Cybersecurity enhancements for IEC & UL 2900-2-2 certification, including stronger encryption, configurable password policy. The card shall work on GIGABIT Speed and should support all major protocols.
-
-
-
UPS shall be provided with Temperature Humidity Sensors to monitor Temperature and Humidity over LAN through SNMP card Software.
-
-
-
SMF batteries for 30 minutes backup complete with MS Fabricated battery rack to accommodate the all battery system, Suitable for 30 Min backup on Full load at 0.8 Load P.f. with each 80kVA UPS, Battery Flexible design shall be available Battery type should be Valve regulated lead-acid (VRLA). Battery Calculations to be submitted for approvals before supply.
-
-
-
Battery open rack with top cover, battery interlinks, battery breaker(MCCB), Battery breaker enclosure, battery to UPS cable as required should be provided with UPS systems with complete with all connecting leads with required accessories including lugs, glands etc.
-
-
-
UPS system shall be parallelable upto 4 units. Each UPS shall be compatible for working in parallel redundant mode with other and should be able to be used with Lithium Ion Batteries if required in future. Parallel kit to be supplied with UPS System. There shall be minimum two year warranty on UPS system and batteries after expiry of deffect liability period (DLP).
-
-
-
Supply, installation, testing & commissioning of 60 kVA UPS in parallel with Inbuilt Input Isolation Transformer, working in parallel configuration and having the following specification-
3
1229701
3689103
True online double conversion, IGBT Rectifier & IGBT inverter based UPS. Three phases Input/ three phase output. Input voltage operations on mains without switch over to battery : 340-478V at 100% load, 220-478 V @ 50% load.
-
-
-
Input power factor 0.99 @ 100% linear load, input THDi 5% @ 100% linear load.
-
-
-
UPS system shall have rated Output Power Factor-1 (80kVA @80kW)
-
-
-
UPS shall carry design output at 40 deg. Crest factor 3:1,
-
-
-
Output THD is less than 3% for full linear load & Less than 5 % for nonlinear load.
-
-
-
Overload 125% for 10 min, 150% for 1 min and should be able to operate continuously at 115% load on bypass mode. Very High online double conversion efficiency up to 96%.
-
-
-
Inbuilt Delta Star Isolation Transformer at Input of UPS System covering Online as well as bypass path, before rectifier and not at the inverter output . No deviation in this regard shall be acceptable. SLD showing Isolation Transformer position, signed and stamped on OEM's letter head to be submitted by the vendor as part of TDS submission for getting manufacturing clearance.
-
-
-
Parallel communication port, RS232, USB, EPO and SNMP interface, BMS interface, Dust Filter at Air Inlet point are required.
-
-
-
LCD Display indicating all important parameters
-
-
-
To improve the UPS Security over LAN/WAN the SNMP card provided with UPS shall be having Cybersecurity enhancements for IEC & UL 2900-2-2 certification, including stronger encryption, configurable password policy. The card shall work on GIGABIT Speed and should support all major protocols.
-
-
-
UPS shall be provided with Temperature Humidity Sensors to monitor Temperature and Humidity over LAN through SNMP card Software.
-
-
-
SMF batteries for 30 minutes backup. complete with MS Fabricated battery rack to accommodate the all battery system, Suitable for 30 Min backup on Full load at 0.8 Load P.f. with each 60kVA UPS, Battery Flexible design shall be available Battery type should be Valve regulated lead-acid (VRLA). Battery Calculations to be submitted for approvals before supply.
-
-
-
Battery open rack with top cover, battery interlinks, battery breaker(MCCB), Battery breaker enclosure, battery to UPS cable as required should be provided with UPS systems with complete.
-
-
-
UPS system shall be parallelable upto 4 units. Each UPS shall be compatible for working in parallel redundant mode with other and should be able to be used with Lithium Ion Batteries if required in future. Parallel kit to be supplied with UPS System. There shall be minimum two year warranty on UPS system and batteries after expiry of deffect liability period (DLP).
-
-
-
Supplying, installation, testing and commissioning of 500 kVA silent type DG set ( Prime power rating at 0.8 power factor as per ISO 8528 with Acoustic Enclosure as per the latest CPCB IV norms) complete with following with all accessories and with complete CC/RCC foundation for the job in full respect
2
5100974
10201948
Engine:
Turbocharged diesel engine of 4 stroke, as suitable BHP as per ISO 8528 at 1500 rpm suitable for 500 KVA output of the alternator at site condition, capable of taking 10% overloading available in excess of specified output for one hour in every 12 hrs. The average load factor of the engine over period of 24 hours shall be 0.85 (85%) for prime power output complete with Dynamically balanced flywheel, Flexible coupling, Exhaust gas turbo charged with Cooling System , Automatic safety control in case of low lubrication oil pressure, Automatic safety control in case of high water temperature. Automatic overspeed trip protection. The engine shall have Lubrication oil pump, Lubrication oil filter, Lubrication oil cooler, Bye- pass filter, standard fuel tank, Fuel pump, Fuel Filter, Hoses for fuel tank, Air intake manifold, Air cleaner dry type, Governor mechanical/CRDI type, Selfstarter and engine control panel fitted & having digital display for- start/stop key, battery charging indication, lube oil pressure indication, low lube oil trip indication, water temperature indication, high water temp. indication, RPM indication, over speed indication, engine hours indication etc. Alternator for battery charging. Residential silencer. Flexible pipe for silencer. Fuel tank capacoty of 850 Ltrs or as suitable, Batteries for excitation with Battery charger. The engine shall confirm to IS; 10000/ ISO 3046/ BS;649/BS 5514 ammended upto date. It shall be compete with all as required with first fill of fuel (500 ltrs) and first fill of lube oil complete as per norms.
-
-
-
Alternator:
Synchronous alternator rated 500 kVA at 1500 rpm, 3 phase, 415V ,50Hz AC supply with 0.8 pf (lagging) at site condition.The alternator shall have SPDP enclosure (IP-23), brushless continous duty, self excited and self regulated suitable for the environmental conditions and with H class of insulation, +/- 1% Voltage regulation, +/- 5% Voltage variation, +/- 1% frequency vairation, overload duration/ capacity of 10% one hour in every 12 hrs. of continuous use and 50% over load for 15 seconds.The alternator shall be capable for step load/ transient load as per ISO 8528. The alternator shall be fitted with thermistors (controlled by AMC controller) for winding and bearing temperature and space heaters, AVR (electronic), battery charger for self excitation with boost and trickle charging facility etc. complete in all respects as per IS: 4722 & IEC 34.
-
-
-
Accoustic Canopy: as per latest CPCB IV standards
-
-
-
The rates shall include complete supplying, installation, testing and commissioning rates including complete cost of CC/RCC foundation as required complete in all respect including vibration isolation springs/pad as per OEM requirements and site conditions, POL/fuel for testing purposes as per CPWD specifications, and all tools and accessories required to Complete the job in full respect, Painting of all exposed metal surface with approprite colour, clearance approval for complete installation from CPCB/State pollution control board/ Central electricity authority (ECA)/Local bodies and other licencing authorities, whereever required including two year warranty after expiry of defect liability period(DLP) as per approved make.
-
-
-
Supply of one no. XLPE cable aluminum conductor steel armoured power cable of 1.1kV grade of size 3-1/2x 400 sq.mm. complete as required and as instructed by Engineer in charge.
400
1836
734400
Supply of one no. XLPE cable aluminum conductor steel armoured power cable of 1.1kV grade of size 3-1/2x 240 sq.mm. complete as required and as instructed by Engineer in charge.
100
1175
117500
Supplying & fixing suppporting MS structure made from ISMC 100 Ls x 50x5 chanel for exhaust piping upto above top of the building complete as required for supporting DG exhaust system and as instructed by Engineer in charge. including cutting, bending, welding & painting etc as required to make it complete.
2
175362
350724
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
Above 185 sq. mm and upto 400 sq. mm
60
416
24960
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
Above 185 sq. mm and upto 400 sq. mm
60
312
18720
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
-
-
-
Above 185 sq. mm and upto 400 sq. mm
5
117
585
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
-
-
-
Above 185 sq. mm and upto 400 sq. mm
170
101
17170
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
Above 185 sq. mm and upto 400 sq. mm
375
198
74250
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
1
445
445
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
3½ x 240 sq. mm (62mm)
4
900
3600
3½ x 400 sq. mm (82mm)
16
1364
21824
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required
-
-
-
100 mm dia
6
1583
9498
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
25
289
7225
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5
6552
32760
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
8
12133
97064
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
30
852
25560
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50mm)
10
126
1260
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,
bolt, spring, washer excavation and re-filling etc. as required.
40
1360
54400
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
10
619
6190
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
260
1019
264940
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
55
214
11770
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
10
111
1110
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
2
1853
3706
Supplying, laying, fixing, testing and commissioning of following nominal size of pipe ( with necessary clamps, vibration isolation ect. )duly insulated with fire retardant quality expended polystrene moduled pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive rapping with 500g polythene faced hessain and finaly applying 0.63 mm aluminium sheet cladding complete with type 3, grade 1 roofing felterstrip at joint repairing of damage to built etc as per specification suitable for exhaust for DG set complete as required and as instructed by Engineer in charge.
66
6336
418176
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%