Indian Institute Of Technology Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

Indian Institute Of Technology - IIT Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Mar 2025
Closing Soon11 Mar 2025
Tender Amount₹ 10,75,701 
Notes
Download

Costs

Summary

Dismantling, Shifting And Recommissioning Of Precision Air Conditioning Units 2 X 115.5 Kw Capacity From Cc To C3i Restructuring Server Room With Other Associated Works At Iit Kanpur

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Re-Installation of the above supply material required material for testing (Nitrogen Pressure), Vaccumising, Oil charging, Gas charging & Re- Commissioning of complete PAHU circuit of 2X 115.5 Kw functioning as per requirement of C3i newly specified area and as per directions and approval of Engineer-in-charge.

1

95000

95000

... More
Supply and charging of Compressor oil for existing PAHU unit TDAV3342 (115.5KW) Danfoss compleate as required

12

8650

103800

... More
Dismantling, removing of all support from CC and shifting & re installation of raised floor tiles ground floor at C3i newly specified area complete as per directions and approval of Engineer-in-charge.

50

747

37350

... More
Supply of Filter drier for existing PAHU unit TDAV3342 (115.5KW) Part no: FIDE011X1AN compleate as required.

4

4550

18200

... More
Refrigerant Piping

-

-

-

... More
Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping suitable for R22 refrigerant of suitable size as required and duly insulated with 19mm thick nitrile rubber class "O" in tubing insulation inclusive of glass cloth and UV treatment. form having K value as 0.032 W/ m Deg. etc External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported by using GI ladder type cable trays. The cost of GI covered cable tray and supports to be included in the quoted price.Entire refrigerant piping work be carried out between indoor units and remote condensers and complete piping shall be provided as per Standard with necessary Elbows, all fittings and in accordance with the specifications. Piping shall be of following sizes:

-

-

-

... More
Hard drawn Cu Pipe 11/8" 18 Guage with Red Paint complete/ fittings (minimum 18 Gauge)

80

1680

134400

... More
Hard drawn Cu Pipe 7/8" 18 Guage with Yellow Paint complete/ fittings (minimum 18 Gauge)

100

1450

145000

... More
Supply & charging of R22 refrigerants for PAHU etc, including charging port, gauge etc after proper vacuuming.

150

729

109350

... More
Drain/ Humidifier Piping

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

5

392

1960

5

478

2390

5

641

3205

5

862

4310

... More
Supplying & fixing, insulation on existing pipe overhead/underground of following sizes 25 mm thick without Aluminium faced XLPE foam pipe section fixing with dentride and tightening of insulation section PVC tape to be wrapped all around the joints. of insulation etc complete as required.

-

-

-

5

164

820

10

185

1850

5

201

1005

5

232

1160

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c MS angle-clamp fittings as per standard specification complete as required including cutting & making good the walls etc. Internal work - Exposed on wall.

-

-

-

5

464

2320

10

533

5330

5

685

3425

5

844

4220

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

600

105

63000

... More
Providing, laying, testing, and commissioning of following size Un-armoured XLPE insulated Copper conductor power/control cable of following size on surface/recessed complete as required. ( Indoor to outdoor cable) 3core 2.5sqmm

-

-

-

... More
3 Core x 2.5 Sq mm

180

107

19260

... More
DUCTING & INSULATION

-

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
0.63 mm (24 g)

10

1001

10010

... More
0.80 mm (22 g)

5

1148

5740

... More
1.00 mm (20 g)

10

1530

15300

... More
Dismantling and removing of existing old ducts of any size, i/c removing of hangers , flanges , damper, diffuser, grill and depositing in the sectional store complete as reqd.

25

156

3900

... More
Supplying & fixing of powder coated extruded aluminum Return Air Grills with lowers but without aluminum volume control dampers as reqd

10

5256

52560

... More
Dismantling and refixng of old grill and diffuser, VCD after cleaning as reqd.

10

240

2400

... More
Supplying and fixing of following thickness duly laminated aluminum foil of matfinish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.(for floor insulation)

-

-

-

80

677

54160

... More
Providing & fixing of thermal insulation without aluminium foil faced XLPE Class 'O' insulation sheet of following thickness on existing surface of pipe/duct with dentrite/adhesive etc.The joints shall be sealed with 50 mm wide and self adhesive PVC/Aluminum tape complete as required.

-

-

-

10

249

2490

10

363

3630

... More
Buyback of old copper piping , supports etc

120

860

-103200

... More
SH-II Fire Alarm System & Fire Extinghuishers

-

-

-

... More
FAS (Integrated with BMS)

-

-

-

... More
Intelligent Addressable Fire Alarm Control panel with 1 Loop Capacity expandable up to 1 loops in future. The panel shall consisting with 80 character LCD display and RS 485 for networking. Each Loop should have the capacity to cater to 125 devices and 125 detectors per Loop. The vendor shall consider the necessary (if required) interface modules, integrators etc and all module necessary for successful operation and BMS integration of the complete system as per the site requirement.

-

-

-

... More
Supply, installation, Testing and Commissioning of Intelligent Addressable Multi-sensor detector with multiple sensitivity levels,( adjustable at site) programmable for timed automatic sensitivity selection and with standard base, with inbuilt Isolator

12

5937

71244

... More
Supply, installation, Testing and Commissioning of Addressable Break Glass type Manual Call Point

2

9315

18630

... More
Supply, installation, Testing and Commissioning of Response Indicator for detectors located in False Floor and False Ceiling

8

139

1112

... More
Supply, installation, Testing and Commissioning of Sounder cum Strobe 85 db

2

3694

7388

... More
Power Supply 24 volt DC 10 Amp

2

2586

5172

... More
Supply, installation, Testing and Commissioning of Control Modules

1

5853

5853

... More
Supply, installation, Testing and Commissioning of Relay Modules for Tripping

1

6781

6781

... More
Supply, installation, Testing and Commissioning of Fault Supply Isolator Module

1

5446

5446

... More
Supply and fixing of GI Terminal Box 4x4 inch

20

139

2780

... More
Supply and laying of 2 core armured cu. Cable of size 1.5 Sqmm

50

107

5350



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.