Indian Institute Of Technology Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Indian Institute Of Technology - IIT Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Dec 2024
Closing Soon17 Jan 2025
Tender Amount₹ 6,56,970 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE

2

540

1080

1

791

791

3

1118

3354

12

1429

17148

2

1784

3568

... More
100 mm

1

2601

2601

... More
Supplying & fixing insulation on existing MS 'C' class pipe over exposed surface/underground of following sizes with 50/75 mm thick fire retardant thermocole (polystyrene) molded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessian cloth, wire mesh, sand-cement plaster & enamel painting two or more coat to give even shade after applying one coat of ordinary paint etc complete as required.

-

-

-

2

271

542

1

315

315

3

355

1065

12

402

4824

2

441

882

... More
100 mm

1

532

532

... More
SITC of Butterfly valves CI body with SS Disc Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water with hand lever operated including nut, bolt, flanges, gasket and insulation of valve as kind of existing pipe etc. complete as reqd.

-

-

-

1

3133

3133

1

3278

3278

2

3704

7408

... More
Providing & fixing of thermal insulation with aluminium foil faced XLPE Class 'O' insulation sheet of following thickness on existing surface of pipe/duct with dentrite/adhesive etc.The joints shall be sealed with 50 mm wide and self adhesive PVC/Aluminum tape complete as required.

-

-

-

50

419

20950

... More
P & F of acoustic insulation with open cell Nitrile rubber sheet(Accosound) super silence of following thickness, on existing surface with adhesive i/c nut, bolt washer as req on duct.etc. complete as required.

-

-

-

20

1443

28860

... More
Dismantling & removing of Air handling unit (Floor/ceiling type) with associated parts and disconnecting from CHW line & ducting etc. complete as reqd.

-

-

-

... More
AHU 2501 CFM to 6000 CFM/4-6 R cooling coil.

1

5376

5376

... More
Cutting & dismantling of condenser / chilled water pipe line with grinder/welding machine/gas cutter for drain out the water from supply and return pipe line and making good after leakage repairing i/c re-filling of water in pipe line size from 20 mm to 400 mm dia including isolation of defective pipeline, valve operation, testing & commissioning etc as required.

-

-

-

... More
20 mm to 100 mm dia.

1

1506

1506

... More
Providing & fixing of SS ball valve of following size with compatible to proportioning Copper/MS pipe i/c all necessary accessories, support /hangers, including old dismantling if any complete as reqd.

-

-

-

1

2853

2853

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valve, MS Nipple, socket etc complete as required.

2

1068

2136

... More
Providing & fixing in position the mercury in glass industrial type thermometers.

2

931

1862

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
0.80 mm (22 G) thick

25

1097

27425

... More
0.63 mm (24 G) thick

25

945

23625

... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications

2

6291

12582

... More
Supply & fixing of fire retardant double cloth canvass made (up to 300 mm vide) with heavy clothes and suitable frame with G.I washer, nuts & bolts in suitable size. i/c jointing both sides with suitable gaskets complete as reqd.

1

3319

3319

... More
Supplying & fixing of powder coated extruded aluminium supply Air Grills with volume control dampers complete as required.

2

8129

16258

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills without volume control dampers complete as required.

2

8491

16982

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

1

10879

10879

... More
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

1

7251

7251

... More
Providing, laying, testing, and commissioning of following size Un-armoured XLPE insulated Copper conductor power/control cable of following size on surface/recessed complete as required.

-

-

-

... More
4 Core x 2.5 Sq mm

20

139

2780

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required

-

-

-

... More
2 x 1.5 sq. mm

20

64

1280

... More
3 x 1.5 sq. mm

20

86

1720

... More
Dismantling and removing of existing old ducts of any size, i/c removing of hangers , flanges , damper, diffuser, grill and depositing in the sectional store complete as reqd.

30

142

4260

... More
Dismantling & re-fixing of same (Modified) existing old ducts of any size i/c removing of hangers , flanges , damper, diffuser, grill complete as reqd..

20

342

6840

... More
Making wall opening up to 750 mm dia/Suitable in any type / thick of wall for pipe/duct etc and re-closing the opening with brick, sand, cement and plaster up to 20 mm i/c re-painting as per existing desigine/shape complete as required.

2

629

1258

... More
Cutting and dismantling of damaged and defective MS'C' class pipe of size as mentioned below ( exposed over the surface/ underground ) i/c shifting the same to sectional store or desired location i/c cartage.

-

-

-

... More
20 mm to 100 mm dia.

50

178

8900

... More
Cutting & dismantling of damaged and defective insulation, removing the thermocole , nitrile, PUF insulation or cladding from chilled water MS pipe line of size mentioned below including hessian cloth, wire mesh, sand, cement, plaster, cleaning of pipe and shifting the waste material outside the premises of I.I.T. K. campus or desired location as reqd.

-

-

-

... More
20 mm to 100 mm dia.

50

154

7700

... More
Dismantling of Cassacatte AC of Hi-wall/wall/floor mounted or ceiling suspended type up to 3.5 TR capacity including filter and valves etc. Complete as required.

2

782

1564

... More
Supply, Installation, Testing and Commissioning of variable frequency drives for the above mentions Air Handling Unit. Variable frequency drives shall be provided with necessary sensors, transmitters and complete with control wiring in all respect as required and as per specs. The drives shall be suitable for the following motor rating. VFDs shall be housed in VFD Panels.

-

-

-

... More
4 KW (FC-51 Series) danfoss or equivalent.

1

22806

22806

... More
Supplying, fixing, testing and commissioning Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.

-

-

-

1

6855

6855

... More
Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20 mA electric signal and providing similar transducer feedback output to control system as required.

-

-

-

... More
65 mm

1

13194

13194

... More
Providing and fixing Digital type thermostat for FCUs/AHUs commissioning i/c dismantling old if any etc. complete as reqd.

1

4568

4568



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.