Indian Institute Of Management Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Indian Institute Of Management - IIM Tender
Electrical and Maintenance Works
Eprocure
Opening Date9 Jul 2020
Closing Date17 Aug 2020
Tender AmountRefer Documents
Costs
EMD
₹ 36,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_IIML_570110_1Bid Award Id
ViewTender No
IIML/PROJ/TENDER/2020/4276Tender Authority
Indian Institute Of Management ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
TENDER FOR SUPPLY AND INSTALLATION OF 4 NOS 4 TR FLOOR MOUNTED AIR CONDITIONING, 2 NOS 2 TR FLOOR MOUNTED AIR-CONDITIONING and 5 NOS 2 TR SPLIT AIR CONDITIONING IN HALL 3 OF BODHIGRAH II ALONG WITH ALL ELECTRICAL WORK AT IIM, LUCKNOW
BOQ Items
PART-I_ELECTRICAL WORK - AIR COOLED TOWER/STANDING UNITS
-
-
-
SITC of 2.0 TR Air-cooled TOWER/Standing type unit with Refrigerant, vibration isolators, with suitable foundation etc. complete as required. All necessary MS structure for supporting units, Anchor fasteners, nut, bolts etc. Unit shall be suitable for operation on 230 voltage+/-10%, 50 Hz electrical power supply. With outdoor stand and MS stand painted with anti-rust paint for mounting ODUS (As per specification given in Annexure-A).
2
-
-
SITC of 4.0 TR Air-cooled TOWER/Standing type unit with Refrigerant, vibration isolators, with suitable foundation etc. complete as required. All necessary MS structure for supporting units, Anchor fasteners, nut, bolts etc. Unit shall be suitable for operation on 410 voltage+/-10%, 50 Hz electrical power supply. With outdoor stand and MS stand painted with anti-rust paint for mounting ODUS (As per specification given in Annexure-A).
4
-
-
PART-II-LOW SIDE AND INSTALLATION-Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of Interconnecting refrigerant copper pipe work suitable for R-410A / R-32 or eco-friendly refrigerant with suitable supports, jointing/brazing including accessories, also along with (19mm) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications. All piping shall be properly supported with MS, GI STUDS/CLAMPS/HANGERS. The refrigerant pipes running in vertical shaft shall be supported on MS angle and wooden saddle at every 1200 mm distance and the pipes which are running horizontally above the false ceiling should be supported on MS angle/slotted angle at every 1200 mm distance.
-
-
-
19.1 mm dia (OD) with tube thickness 1.2 mm with 19mm thick insulation
80
-
-
12.7 mm dia (OD) with tube thickness 1.2 mm with 19mm thick insulation
80
-
-
15.8 mm dia (OD) with tube thickness 1.2 mm with 19mm thick insulation
60
-
-
9.5 mm dia (OD) with tube thickness 1.2 mm with 19 mm thick insulation
60
-
-
PART-II- LOW SIDE AND INSTALLATION-Supplying and fixing of 25mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
50
-
-
PART-II- LOW SIDE AND INSTALLATION-Supplying and drawing following sizes of FRLS PVC insulated copper conductor and, single core cable in the existing surface/recessed steel/ PVC conduit as required.
-
-
-
2.5 sq. mm. 4 core flexible copper
80
-
-
4.0 sq. mm. 4 core flexible copper
80
-
-
6.0 sq. mm. flexible copper
180
-
-
10.0 sq. mm. flexible copper
180
-
-
PART-III- Electrical
-
-
-
Supply & Laying of 3.5C x 95 sq. mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade from panel to TP & N on cable tray. Termination of cable at both the end with appropriate lug and all the accessories required for termination.
50
-
-
Supplying and fixing of 6 way (4 + 18), Double door , horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1
-
-
Providing and fixing 200 A, 36 KA, four pole MCCB and breaking capacity 50kA and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
1
-
-
Supplying and fixing 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (for DB box) - DP 32A,240V
7
-
-
Supplying and fixing 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (for DB box) - TP 63A, 440V
4
-
-
Wiring for circuit/ sub main wiring along with earth wire with the 2 X 6 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required and termination of cable with appropriate lug at both the ends (complete in all sense with material like wire, PVC conduit and accessories including all civil work etc.). For 2 Tr. Split AC
180
-
-
Wiring for circuit/ sub main wiring along with earth wire with the 3 X 10 sq. mm + 1 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required and termination of cable with appropriate lug at both the ends (complete in all sense with material like wire, PVC conduit and accessories including all civil work etc.) For 4 Tr. Floor mounted AC
100
-
-
Supply and fixing of industrial type AC box recessed along with SP 32 A MCB
7
-
-
Supply and fixing of TPN AC box recessed along with TP 63 A MCB
4
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
50
-
-
PART-IV- SUB-HEAD 'D' CIVIL
-
-
-
Dismantling stone slab flooring laid in cement mortar i/c disposal 50 mtr.
70
-
-
Demolishing CC nominal concrete 1:3:6 or richer mix.
7.5
-
-
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of E-in-C. In cement mortar.
0.75
-
-
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
15
-
-
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.
70
-
-
Kota stone slab 16 to 22 mm thick (semi polished)
70
-
-
12 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand).
50
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
20
-
-
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand).
11
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
25
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
50
-
-
P/F of drain SS jali for 2" pipe hole complete job including fixing and finishing.
9
-
-
P/F of 50mm thick PVC drainage pipe 4kg pressure Astal or equivalent make of approved quality including all fixtures like bend, socket etc. complete job.
115
-
-
Core Cutting upto 150 mm in Masonary/ Concrete for Passing of Pipes etc. through it
10
-
-