Hindustan Urvarak And Rasayan Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Hindustan Urvarak And Rasayan Limited - HURL Tender

Services
Manpower Supply
Eprocure
Opening Date8 Jun 2024
Closing Date28 Jun 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removal of Control Valves 2" 600LBS

40

-

-

... More
Fixing of Control Valves 2" 600LBS

40

-

-

... More
Transport of Control Valves upto 2"

80

-

-

... More
Transport of Control Valves 2"&=4"

100

-

-

... More
Transport of Control Valves 4"

60

-

-

... More
Removal/Fixing of CV from Bonnet upto 6"

40

-

-

... More
Removal/Fixing of CV from Bonnet6"&=24"

40

-

-

... More
Removal/Fixing of Actuator of CV upto 8"

40

-

-

... More
Removal/Fixing of Actuator ofCV 8"&=24"

40

-

-

... More
Transportation of Actuator to & from W/s

80

-

-

... More
Removal of Control Valve positioner

200

-

-

... More
Fixing of Control Valve positioner

200

-

-

... More
Removal of Solenoid Valves

600

-

-

... More
Fixing of Solenoid Valves

600

-

-

... More
Removal of Valve Limit Switch

200

-

-

... More
Fixing of Valve Limit Switch

200

-

-

... More
Removal of Volume Booster

200

-

-

... More
Fixing of Volume Booster

200

-

-

... More
Removal of air filter regulator

400

-

-

... More
Fixing of air filter regulator

400

-

-

... More
Laying of Inst Air headers lines

50

-

-

... More
Laying of Inst Impulse Pipe lines

100

-

-

... More
Removal of Different Type flow meters 4"

40

-

-

... More
Fixing of Different type Flow Meters 4"

40

-

-

... More
Transportation workshop Flow Meters

40

-

-

... More
Removal of orifice plates 4"

30

-

-

... More
Fixing of orifice plates 4"

30

-

-

... More
Fabricate,clamp,support,canpyMS/Al

100

-

-

... More
Fabricate,clamp,support,paint 4ftx2ft

40

-

-

... More
fixing of diff type of Level instruments

60

-

-

... More
Removal of diff type Level instruments

60

-

-

... More
Transportation workshop of Level Instrum

60

-

-

... More
Removal of pow cylind of damp/CV 3"

60

-

-

... More
Fixing of pow cylind of damp/CV 3"

60

-

-

... More
Transportaion workshop of pow cylind 3"

60

-

-

... More
Removal of pow cylind of damp/CV 3"&=6"

30

-

-

... More
Fixing of pow cylind of damp/CV 3"&=6"

30

-

-

... More
Transportaion of pow cyl to W/s 3"&=6"

30

-

-

... More
Laying of cable trays 50 mm wide

700

-

-

... More
Laying of cable trays 100 mm wide

200

-

-

... More
Laying of cable trays 150 mm wide

240

-

-

... More
Laying of cable tray (300,600,750)mm wid

400

-

-

... More
Lay and clamp of cabl 4traid X 0.5/1.5mm

2000

-

-

... More
Lay and clamp of cabl 36raid X 0.5/1.5mm

2000

-

-

... More
Laying clamping of cables 2/3/4 core

1000

-

-

... More
Laying clamping of cables 12/18/24 core

1000

-

-

... More
Laying and clamping of SS tubes 6mm/1/4"

600

-

-

... More
Lay and clamp of SS tubes 8mm/1/3"

400

-

-

... More
Lay and clamp of SS tubes 10mm/3/8"

400

-

-

... More
Lay and Clamp of SS tubes 12mm/1/2"

600

-

-

... More
Installation of analyzer cylind and trpt

60

-

-

... More
Analyzer sample filt cleaning and replac

60

-

-

... More
Sample cooler cleaning and boxing up

60

-

-

... More
removal of pH meters/Conductivity meters

100

-

-

... More
Removal of Anlalyz cylind & trpt to str

60

-

-

... More
Fixing of pH meters/Conductivity meters

100

-

-

... More
Removal of Gas detectors

40

-

-

... More
Fixing of gas detectors

40

-

-

... More
Removal of 2/3 way Ex.proof JB

30

-

-

... More
Fixing of 2/3 way Ex.proof JB

30

-

-

... More
Removal of 6/8/12 way Ex.proof JB

30

-

-

... More
Removal of flange typ isolation valves o

80

-

-

... More
Fixing of flange typ isolation Valves, L

80

-

-

... More
Removal of 1/2" threaded isolation valve

80

-

-

... More
Installation of 1/2" threaded isolation

80

-

-

... More
Removal of Normal diff pressure/PT/LT/FT

120

-

-

... More
Fixing of Normal diff pressure/PT/LT/FT

120

-

-

... More
Transportation of Normal differential pr

800

-

-

... More
Removal of diaph seal typ diff presPT/LT

80

-

-

... More
Fixing of Diaph seal typ diff pressPT/LT

80

-

-

... More
Trpt diaph seal typ diff Press/PT/PG/LT

40

-

-

... More
Fixing of 6/8/12 way Ex.proof JB

30

-

-

... More
Removal of TT including cable and glands

100

-

-

... More
Fixing of TT including cable and glands

100

-

-

... More
Removal of PG/TG without Capillaries

400

-

-

... More
Fixing of PG/TG without Capillaries

400

-

-

... More
Removal of PG/TG with Capillaries

100

-

-

... More
Fixing of PG/TG with Capillaries

100

-

-

... More
Removal of Thermowell threded or Flanged

100

-

-

... More
Fixing of thremowel threaded or Flanged

100

-

-

... More
Fabrication of frames & support, paint

3600

-

-

... More
Tightening of flange of CV upto 4"

120

-

-

... More
Replacement flange gasket of CV upto 4"

120

-

-

... More
Cleaning of Local Junction Boxes

2000

-

-

... More
Cleaning of Local Control Panels

100

-

-

... More
Cleaning of DCS/ESD Control Panels

2000

-

-

... More
Cleaning of Operator Consoles Monitors

1000

-

-

... More
Cleaning of Field Gauges & Transmitters.

12000

-

-

... More
Cleaning of gas detectors any type/Size

800

-

-

... More
Cleaning of CCTV camera and washing unit

200

-

-

... More
Highly Skilled manpower

1248

-

-

... More
Skilled Manpower

4992

-

-

... More
Unskilled Manpower

8736

-

-

... More
Highly Skilled manpower OT

960

-

-

... More
Skilled Manpower OT

3840

-

-

... More
Unskilled Manpower OT

6720

-

-

... More
Inst Paint or Inst Stencilng or Misc Job

30000

-

-

... More
Calibration/validation of weighbridge

2

-

-

... More
Stamping of standard weights

2

-

-

... More
Stamping of static weigh scales

2

-

-

... More
Stamping of Bagging machines

2

-

-

... More
Calibration of PT/LT/TT/FT

2

-

-

... More
Splicing jobs, OFC and OTDR testing

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.