Haridwar Roorkee Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Haridwar Roorkee Development Authority - HRDA Tender
Electrical and Electronics
Eprocure
Opening Date18 Dec 2024
Closing Date2 Jan 2025
Tender AmountRefer Documents
Costs
EMD
₹ 13,10,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Summary
Supply Installation Testing And Commissioning Of Facade Lighting Dhanush Bridge
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HRDA_78877_1Tender No
Installation Testing and Commissioning Of Facade Lighting Dhanush BridgeTender Authority
Haridwar Roorkee Development Authority ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply installation testing & commissioning of DMX Controller for the system including all other accessories required for the running of the system Controller should have Input Power 5-5.5V DC 0.6A and Output Protocol DMX512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universe should be expandable from 2 to 4 DMX512 universes. It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & Ethernet .Dmx controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. Its must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should have Intuitive backlit keyboard with 10 presets and also have provision of kepad on device for changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C. weight should not be more than 120g. OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad/Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta; clamp to mount on wall. All Dynamic LED lighting fixtures & controllers shall be of same make to avoid integration, synchronization, and maintenance issues in future. To be provided with IP 66 enclosure if installed in external environment.
3
-
-
... More
Supply, Installation, testing and commissioning of DMX Splitter with Input Voltage range : 190-240V AC, Power Consumption 5W max. Housing is made of CRCA with powder coated finish Mounting, 19 inch rack mountable, Operation Temperature -30°C to +55°C, 8 Output with 3pin XLR terminal sockets, Ingress Protection Rating IP20. This unit takes the DMX Signal from DMX Controller & split the signal into 8 separate output channels. The output terminals of Splitters are optically isolated from the input. Splitters should be capable to amplify the DMX signal & allowing the data link to be extended by max. 300 m (1044 ft.) using AWG 22 DMX cable or 150 m (500 ft.) using AWG 24 DMX cable or maximum 20-25 fixture per output channel. To be provided with IP enclosure if installed in external environment.
6
-
-
... More
Supply, Installation, testing and commissioning of Signal Amplifier which dedicated to amplify, forward and insulate the signal that comes from the DMX controller When it is connected to the bus of DMX512. long-distance transmission, realize extending the signal transmission distance, Water proof IP65, compatible with various kinds of power range fixture. Seclusion type, total isolation withstand voltage500v, suitable for long distance transfer or stronginterference environment.External Constant voltage 24V Power supply required to operate the device, DMX Signal is protected from Surge upto 4KV.
15
-
-
... More
Supply, Installation, testing and commissioning of DMX address writer to write automatically address of DMX fixtures.
1
-
-
... More
Supply, Installation, testing and commissioning of 350W 24VDC, IP67, non dimmable, shall be offered with a BIS Approved Potted Driver of IP 66/67 rating made of extruded aluminium to make it more thermal efficient, Led Driver should have Operating input voltage range: 90-305Vac, PF 0.95 and must have safety operation range form 90V - 176Vac. Life time of LED driver should be 80,000 hours and MTBF of LED driver should be ≥ 2,00,000 hrs, Led driver must have SELV output and Case temperature i.e. Tc 90°C
120
-
-
... More
Supply installation testing & commissioning of exterior rated architectural floor/wall mounted IP66, flood light with antiglare snoot complete with adjustable mounting brackets/clamps (as per application). The power consumption should not be more than 100 watts, 40° beam angle with a tolerance of ±15%, CCT-9000-10,000K(Blue color). The housing material should be extruded aluminum, a powder-coated finish, anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. The driver should be integral non dimmable with PF0.9 & THD20%. Supply cables, extension cables, IP67 connectors are inclusive. Minimum IK06. Operating temperature: -20 °C to +50 °C, LED life L70B50: 70000 hours at 50°C.
8
-
-
... More
Supply installation testing & commissioning of exterior rated architectural floor/wall mounted IP66, flood light with antiglare snoot complete with adjustable mounting brackets/clamps (as per application). The power consumption should not be more than 50 watts, 4000 delivered lumens, 30° beam angle with a tolerance of ±15%, CCT-3000K/4000K. The housing material should be extruded aluminum, a powder-coated finish, anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI80, The driver should be integral non dimmable with PF0.9 & THD20%. Supply cables, extension cables, IP67 connectors are inclusive. Minimum IK06. T Operating temperature: -20 °C to +50 °C, LED life L70B50: 70000 hours at 50°C.
12
-
-
... More
Supply installation testing & commissioning of 150Watt Pattern light, 6 GOBO/pattern, Pattern can rotate on its own. Fixture should have Manual focusing option. IP65, Input Voltage 220V-240V, DMX512.
2
-
-
... More
Supply installation testing & commissioning of moving head light of 275-300Watt, RGB, Beam Light, Pan:540 Degree,8Bit/16Bit; Tilt:270 Degree,8Bit/16Bit; Channels Mode:16CH/20CH, Light Source Lamp: discharge lamp, Lamp lifespan:1500hours; 110-240V,50/60Hz; Optical System Beam angle :2°;Fix Gobo Wheels - 13 Gobos+white, Color Wheels - Color gobo:14gobo+white.
2
-
-
... More
DMX MALE SUPPLY CABLE 1M 4 PIN
50
-
-
... More
DMX FEMALE SUPPLY CABLE 1M 4 PIN
20
-
-
... More
DMX EXTENSION CABLE 3M 4 PIN
160
-
-
... More
DMX EXTENSION CABLE 1M 4 PIN
200
-
-
... More
5‐pin 'T' Jointer
100
-
-
... More
5‐pin 'I' Jointer
40
-
-
... More
3 pole IP65 power cable 'I' connector
40
-
-
... More
3 pole IP65 Signal cable 'I' connector
30
-
-
... More
3/4/5 pole IP65 power cable 'T' connector
70
-
-
... More
3/4/5 pole IP65 Signal cable 'T' connector
70
-
-
... More
Power junction box for mounting Power supplies, Controllers/ Decoders, complete with control MCBs, IP66.
120
-
-
... More
Supply, laying and Fixing of weatherproof Copper 4 Pair UTP Cat‐6 Cable for DMX data transfer with Weather Proof IP Boxes including weatherproof connectors and laying of wires in existing conduits or trenches as
3500
-
-
... More
3C X 1.5 Sq.mm. PVC insulated, PVC sheathed, armoured/unarmoured, and stranded copper conductor cable 1100V grade, of ISI Marked as required.
1800
-
-
... More
3C X 2.5 Sq.mm. PVC insulated, PVC sheathed, armoured/unarmoured, and stranded copper conductor cable 1100V grade, of ISI Marked as required.
1800
-
-
... More
Supply and Laying of one number 4 core x 70 q mm Aluminium Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required.
300
-
-
... More
Supply and Laying of one number 4 core x 50 q mm Aluminium Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required.
400
-
-
... More
Supply and Laying of one number 4 core x 30 q mm Aluminium Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required.
480
-
-
... More
Supply and laying of 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1000
-
-
... More
Belden cable
1200
-
-
... More
Supply and fixing 25mm MS flexible ISI marked FRLS along with the accessories in concealed system etc. as required. The colour to be matched with the bridge texture.
2400
-
-
... More
Supply of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete. The instrument chamber shall be saprate and shall comprise of Multifunction meter and current transformer etc. The board shall have suitable cappcity electrolytic copper bus bars as per IS:8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC /DMC supports with detchable side covers and shall be suitable for extension on the sides .the switches shall be complete with suitable with cable and boxes ,revers entry boxes in case of pedestal type cable socket compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer Incharge The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm cubical type switch board shall be of Cat A, B & B = II only outdoor type with following incomming and outgoings INCOMMING MCCB‐100Amp TPN‐01 Multifunction meter‐01 RYB Indicators‐01Set Digital control Servo Voltage Stabalizer of 40KVA oil type with voltage range from 260Volt to 480Volt OUTGOING 63 Amp DP MCB‐ 08 No 15Amp Combined Socket‐04No Space for company DMX Splitter
2
-
-
... More
Providing earthing with copper earth plate, 600mmX600mmX3mm thick with all accessories, providing masonry enclosure with cover plates having locking arrangement & watering pipe of 2.7m long, with charcoal/coke and salt, complete with all materials, ,
4
-
-
... More
Programming, testing and commissioning and maintenance of scenes for 5 years with programming of different color patterns as per engineer in charge.
1
-
-
... More
Supply, Installation & Integration of control room (Porta Cabin) of required size with Air‐conditioning systemof appropriate capacity in Control room to maintain temperature for coolingof equipments 3 star BEE rated 1.5 ton or higher capacity split AC with inverter technology stabilizer free operation and all necessory requirements for show control. With Required Furniture
1
-
-
... More
Installation, mounting arrangements with all the required accessories, labour, Crane hiring, Scaffolding and training of the complete illumination system for the Bridge; as per site requirement.
1
-
-
... More
Providing fixing minimum four IP rated high effeciency, HD CCTV Cameras with all necessary arrangements.
1
-
-
... More
Facbrication and Iron work, Safety Jali with lock/key for flood lights as per site requirement for mounting & fixing of all the luminairies, cable etc…
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%