Hapur Pilakhua Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Hapur Pilakhua Development Authority - HPDA Tender
Transportation and Logistics
Eprocure
Opening Date14 Jan 2020
Closing Date27 Jan 2020
Tender Amount₹ 17,02,000
Costs
EMD
₹ 85,100Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_HPDA_423648_2Bid Award Id
ViewTender No
581/CE/HPDA/2019 Dt. 14-01-2020 SBTender Authority
Hapur Pilakhua Development Authority ViewPurchaser Address
-Website
http://https://hpdaonline.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and erection of stay set at least 3.5 metres away from the pole complete with galvanised 19mm dia. x 1.80 meter long stay rod, 30cm x 30cmx6.3 mm anchor plat, thimble stay clamps, stay insulator, 19mm x 600mm double serew tightener, 7/3.15 mm G.I. stay wire etc. in 1:3:6 cement concrete in all respect of E/I. SOR.No-631/18
12
-
3029
S/F of suspension clamp suitable for hanging of various size ABC conductor on pole etc all complete as required.
37
-
250
S/E of 120sqmm X 3 C + 1 x 95 sqmm + 1 x 16sqmm XLPE insulated ABC bare messenger wire etc complete as per direction and approved by E/I.
1100
-
450
S/Fof pole mounted type CMS TPN distribution box Sintex size 400 X 300 X 190 MM & 4 Nos. 40 X 50 mm aluminium bus bar with ingress protection to IS 8623 cable entry from bottom & /or sides shockproof & rustproof, suitable for polluted atmostpheres were high working tempreture & higher arc resisteance witherproof & maintenance free complete with supporting clamp i/c locking arrangement & painting etc complete as per direction of E/I.
38
-
4420
S/F of 2.5mt. long 20mm dia MS earth rod with 6 SWG GI earth wire, nut, bolt & washer etc all complete.
11
-
906
PART C :- Sub Station
-
-
-
S/E of Double pole stucture ( FOR POLE / PLINTH MOUNTED TRANSFORMER TYPE SUBSTATION )12mt. long 410 SP-62 ST pole (259 Kg) support grouted in 1:3:6 (cement coarse sand 6 graded stone aggregate 40 mm nominal size) including 30 cm high plinthing from ground level with the cost of 3 no 100 x 50 x 6mm 2.24 Mr long Chanel and 3 no. 75 x 40 x 6mm 2.24 Mtr lon Chanel and With D.O. Fuse set , T.P.M.O. switch , anticlimbing device and paintig of pole Complete with all material lab. T&P etc required for proper completion of work or as direction of E/I. (Less coast of 2 nos. ST Pole SP-62- (71600- 45418=26182 )
2
-
26122
S/F of danger board with clamp nut & bolt etc all complete. SOR. NO. 1109/18
4
-
85
S/F of stay set at least 3.5 mtr. Away from the pole complete with GI 19 mm dia. & 1.80 long stay rod 30 cm. x 63 cm. Anchor plate thimble stay clamp, stay insulator, 19x600 mm. double screw tightner, 7/8SWG GI stay wire etc in 1:3:6 cement concrete & grauting as per direction of E/I. SOR NO.-631/18
4
-
3029
Supplying and erection of 11 kV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. DSR 2018 SI NO. 13.10
6
-
269.76
Supplying and erection of 11 kV disc insulator for 11 kV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. DSR 2018 SI NO 13.11
6
-
893.76
Supply and burying earth electrode for lightning conductor of 600mm x 600mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia. G. I. pipe for watering funnel, 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal / coke and salt at least 150 mm thick alround etc. as per directions of E./Ic. complete in all respect. SOR NO.-703/18
6
-
5380
Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect.SOR NO.-717/18
40
-
150
Supply, Installation, Testing and commissioning of 100KVA 11/0.433kv Aiuminium/copper wound distribution T/F Level-1or 2 Rating complete as per UPPCL specification etc all complete.
2
-
170996
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 65 and above protection complete in all respect.SOR No. 1421 CAT - AAA /2018
40
-
4940
Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. SOR NO.-807(f)/18-- 15 A TPN
2
-
17200
S/L of "AL" cable size of 10 sqmm. 4 core. (less 327-170=157) as per sor no 507
20
-
157
Detailed Specfication of LED Street Light
-
-
-
S/F of 45-50 watt factory wired LED light fitting, having pressure di-cast aliminium housing, complete LED light fitting must be approved from Bueru of Indian Standard- IS-10322(Part 5/Section 3) 2012 and conforming IP-66/67 proctection level, follow LM-78/79 test report and approved in AAA catagary in UP PWD Lucknow. LED fixture must have proper heat desipation. working temprature 5-50 degree celcious, having surge proection, for electronic driver, Surge protection device having 10 KA rating. Driver efficency more then 85%, CR70, Driver must have voltage regulation from 140-280 v, 50 Hz. , lumen out put of LED module must be 100-Lum per Watt, warm white colour, Each LED module must have optical lance for uniform distribution of light. These LED light fixture will be installed on the 50mm dia- 5mm thickness B class GI pipe bracket bended on suitable angle fixed with 50mm x 6mm iron pole clamp (2 set) with nuts and bolts. For connection of these LED light having 40/76 fiexible copper wire or 2.5mm strended 2 core- pvc insulated PVC sheathed aluminum cable with suitable langht.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements