Hapur Pilakhua Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Hapur Pilakhua Development Authority - HPDA Tender

Works
Building Construction
Eprocure
Opening Date1 Jun 2019
Closing Date28 Jun 2019
Tender Amount₹ 3,84,27,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8Kms. from the site of work and including watering, dressing etc, labour and T&P etc. required for the proper completion of the work. saplings of girth up to 30cms. measured at a height of 1M. above ground level and removes of rubbish up to a distance of 50M. out side the periphery of area cleared.

85

39100

460

... More
Concrete with 4cm. gauge stone ballast, coarse sand of 2.20 F.M and cement in proportion of 8:4:1 in foundation and under floors, including supply of all materials, labour, T&P etc. required for proper completion of the work.

106

551200

5200

... More
RCC work with cement, approved Coarse sand and 20mm stone grit in proportion of 1:1.5:3 in raft foundation and footings excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, T&P etc. required for proper completion of the work, including cost of binding wire.

261.6

1765800

6750

... More
M.S (Tor steel or plain) work in plain work such as RCC or RB work including bending for proper shape and including supply of steel and its wastage, bend, hooks and authorized over lapping shall be measured and including cost of binding wire.

360

2016000

5600

... More
M-150 brick work in 1:6 cement and fine sand of 1.25 fineness modulus mortar in foundation and plinth including supply of all material, labour T&P etc. required for proper completion of the work as per direction of the work as per direction of Engineer-in-charge.

62

262260

4230

... More
Concrete with 4cm. gauge stone ballast, coarse sand of 2.20 F.M and cement in proportion of 8:4:1 in foundation and under floors, including supply of all materials, labour, T&P etc. required for proper completion of the work.

64

332800

5200

... More
RCC work with cement, approved Coarse sand and 20mm stone grit in proportion of 1:1.5:3 excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, T&P etc. required for proper completion of the work, including cost of binding wire.

-

-

-

... More
A) For Column Work

-

-

-

... More
(i) Ground Floor & First Floor

80.6

644800

8000

... More
(ii) Second Floor

40.3

325624

8080

... More
(iii) Third Floor

48.2

393312

8160

... More
B) For Lighter Beam

-

-

-

... More
(i) Ground Floor & First Floor

114.8

861000

7500

... More
(ii) Second Floor

57.4

434805

7575

... More
(iii) Third Floor

81.7

625005

7650

... More
C) For Roof Slab

-

-

-

... More
(i) Ground Floor & First Floor

192.3

1480710

7700

... More
(ii) Second Floor

96.2

748147

7777

... More
(iii) Third Floor

100.1

786185

7854

... More
D) For Lintels (RCC mix 1:1½:3)

-

-

-

... More
(i) Ground Floor & First Floor

8

59200

7400

... More
(ii) Second Floor

4

29896

7474

... More
(iii) Third Floor

4

30192

7548

... More
M.S (Tor steel or plain) work in plain work such as RCC or RB work including bending for proper shape and including supply of steel and its wastage, bend, hooks and authorized over lapping shall be measured and including cost of binding wire

-

-

-

... More
(i) Ground Floor & First Floor

544

3046400

5600

... More
(ii) Second Floor

272

1538432

5656

... More
(iii) Third Floor

322

1839264

5712

... More
M-150 class brick work in 1:6 cement and coarse sand of 1.25 fineness modulus mortar in super structure including supply of all material, labour T&P etc. required for proper completion of the work as per direction of the work as per direction of Engineer-in-charge.

-

-

-

... More
(i) Ground Floor & First Floor

263

1254510

4770

... More
(ii) Second Floor

132

635936

4817.7

... More
(iii) Third Floor

156

759002

4865.4

... More
Same as above item no. 12 but walls of ½ brick thick in 1:4 cement & coarse sand (F.M. 2.20) Mortar.

-

-

-

... More
(i) Ground Floor & First Floor

263

1317630

5010

... More
(ii) Second Floor

132

667933

5060.1

... More
(iii) Third Floor

132

674546

5110.2

... More
M.S or iron work for fabrication of M.S gril & case railing wrought to required from including supply of steel and its wastage including cost of bolts, nuts it required for and welding, grinding and making holes as required of completion of the work.

-

-

-

... More
(i) Ground Floor & First Floor

103.42

656717

6350

... More
(ii) Second Floor

51.71

331642

6413.5

... More
(iii) Third Floor

51.71

334925

6477

... More
Same as in items 502 above but steel Z Section window excluding Glass panes.

-

-

-

... More
Openable Panel

-

-

-

... More
(i) Ground Floor & First Floor

7.36

51520

7000

... More
(ii) Second Floor

3.68

26017

7070

... More
(iii) Third Floor

3.68

26275

7140

... More
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the 3cost of bolt etc complete. 8.8.1 Wedge expansion type 8.8.1.1 Fastener with threaded dia 6 mm

2112

53328

25.25

... More
Cement concrete with 2cm gauge approved stone grit,coarse sand & cement in the proportion of 4:2:1 including supply of all materials,labour,Tools & plants etc.required for proper completion of the work.

-

-

-

... More
(i) Ground Floor & First Floor

9

56250

6250

... More
(ii) Second Floor

5

31562

6312.5

... More
(iii) Third Floor

5

31875

6375

... More
Providing and fixing PVC chicken wire mesh including supply of all materials,labour,Tools & plants etc.required for proper completion of the work.

248

7440

30

... More
12mm thick cement plaster with 1:6 cement and approved coarse sand mortar over brick work minimum thickness not to be less than 1cm including supply of all material, labour, tolls and plants etc, required for proper completion of the work as per direction of Engineer-in-charge.

-

-

-

... More
(i) Ground Floor & First Floor

4519

700445

155

... More
(ii) Second Floor

2260

353803

156.55

... More
(iii) Third Floor

2593

409953

158.1

... More
12mm thick cement plaster with 1:6 cement and approved coarse sand mortar over brick work minimum thickness not to be less than 1cm including supply of all material, labour, tolls and plants etc, required for proper completion of the work as per direction of Engineer-in-charge. Add. For extra labour and materials for plaster over rough face of one brick wall.

-

-

-

... More
(i) Ground Floor & First Floor

2329

395930

170

... More
(ii) Second Floor

1165

200030

171.7

... More
(iii) Third Floor

1410

244494

173.4

... More
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).

2666

383370

143.8

... More
Supply and filling of cinder in sunken portion i/c supply of all materials, labour & T&P etc. required for proper completion of the work.

-

-

-

... More
First Floors

11

2333

212.1

... More
Second Floor

11

2356

214.2

... More
Third Floor

11

2379

216.3

... More
8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.1 Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1.1 Area of slab upto 0.50 sqm

111

207733

1871.47

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. 300x300 mm

-

-

-

... More
(i) Ground Floor & First Floor

112

83764

747.9

... More
(ii) Second Floor

55

41545

755.38

... More
(iii) Third Floor

55

41957

762.86

... More
11.36 Providing and fixing Ist quality ceramic glazed wall tiles of size 200x300 mm conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. sqm 744.80

-

-

-

... More
(i) Ground Floor & First Floor

134

99803

744.8

... More
(ii) Second Floor

67

50400

752.25

... More
(iii) Third Floor

67

50899

759.7

... More
Providing and Fixing of 4.00mmx3.00mm depth glass strips as below in joints of floor and skirting at the time of laying floor and skirting flushing with floor level including supply of all materials, labour & T&P etc. required for proper completion of the work.

168

2856

17

... More
4cm thick 1:2:4 plain Cement Concrete floor with cement, approved coarse sand and 2cm graded approved stone grit finished with 3mm (1/8”) floating coat of neat cement of cement and marble dust in ratio 5:1 as specified including removing any over lapping mortar at joints of the panels if any and giving them a uniform finish, including supply of all materials, labour, T&P etc. required for proper completion of the work. with out base concrete.

-

-

-

... More
(i) Ground Floor & First Floor

1393

459690

330

... More
(ii) Second Floor

762

253974

333.3

... More
(iii) Third Floor

794

267260

336.6

... More
2.5 cm (1") thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 2 cm. (1") graded approved stone grit, laid in panels finished with 3 mm. (1/8") floating coat of neat cement of cement and marble dust in ratio 5:1 as specified over and removing any overlapping mortar at the joints of the penals if any and giving them a uniform finish, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work.

-

-

-

... More
(i) First Floor

12

2820

235

... More
(ii) Second Floor

12

2848

237.35

... More
(iii) Third Floor

13

3116

239.7

... More
S/F of hexagonal fan box with hexagonal side of approx 80 mm in length fabricated from 16 SWG M.S. sheet incorporating 10 mm dia M.S. round bar duly bent for supporting fan hanger duly painted with red oxide and screwing arrengement with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all materials, labour, T & P etc. for proper completiom of work.

-

-

-

... More
(i) Ground Floor & First Floor

96

12960

135

... More
(ii) Second Floor

48

6544

136.35

... More
(iii) Third Floor

48

6609

137.7

... More
Providing and fixing 40mm dia & 300mm long I.S.I marked PVC water spout pipe in cement mortar 1:4 cement & coarse sand mortar etc all complete. .

-

-

-

... More
(i) Ground Floor & First Floor

2352

70560

30

... More
(ii) Second Floor

1176

35632

30.3

... More
(iii) Third Floor

1176

35985

30.6

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

-

-

-

... More
(i) Ground Floor & First Floor

2329

203438

87.35

... More
(ii) Second Floor

1165

102776

88.22

... More
(iii) Third Floor

1165

103801

89.1

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)

-

-

-

... More
(i) Ground Floor & First Floor

2329

223700

96.05

... More
(ii) Second Floor

1165

113016

97.01

... More
(iii) Third Floor

1165

114135

97.97

... More
Colour washing one coat using approved.Colouring material buff, blue, gray or brown shade including supply of all materials, labour, Tools & plant etc. required for proper completion of the work.

-

-

-

... More
(i) Ground Floor & First Floor

3648

65664

18

... More
(ii) Second Floor

1824

33160

18.18

... More
(iii) Third Floor

1824

33488

18.36

... More
Painting or varnishing work in small areas or new wood/steel work with one coat ready mixed priming paint and two coat or approved superior quality ready mixed paint or varnish including supply of all materials, labour. T&P etc. required for proper completion of the work. Paint to be used should confirm the ISI.No.103-1950. As per SOR. 641+642

-

-

-

... More
(i) Ground Floor & First Floor

1227

98160

80

... More
(ii) Second Floor

614

49611

80.8

... More
(iii) Third Floor

614

50102

81.6

... More
P/L (Brick coba treatment) integral cement based water proofing treatment including.... preparation of surface as required for treatment of roofs terrace, sunken portion horizontal surface and side wall etc. consisting of following operations applying and grouting a slurry coat of neat cement using 2.75Kg/sqm. of cement and mixed with proprietary water proofing compound confirming to IS 2645 over the RCC slab including cleaning the surface before treatment laying cement concrete using broken brick/bricks bats 25mm to 100mm size with 50% of cement mortar 1:4 (1cement 4coarse sand) and mixed with proprietary water proofing compound confirming IS 2645 to fequi4red slope and treating similarly the adjoining walls up to 300 height in the rounding of junctions of walls and slabs after two day days of proper curing applying second coat of cement slurry admixed with proprietary water proofing compound confirming IS. 2645 finish the surface with 20mm thick joint less cement mortar of 1:4 ( 1cement 4 coarse sand) and mixed with proprietary water proof compound confirming to

-

-

-

... More
IS 2645 and finally finish8ingthe surface with trowel with neat cement slurry and making of 300x300mm square. the whole terrace so finished shall be flooded on water for a minimum period of three weeks to during and for final test all above operations to be done in order and as directed and specified y the E./I with average thickness at Khurra 66mm.

811

729900

900

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :12.21.1 In 75x75 mm deep chase.

60

8812

146.88

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

24

4322

180.1

... More
Providing and laying water proofing treatment in sunken portion of WCs,bathroom etc.,by applying cement slurry mixed with water proofing cement compound consisting of applying : (a)First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/ sqm.This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @0.126 kg/sqm.This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints,corners, junctions of pipes and masonry with polymer mixed slurry.

498

142611

286.37

... More
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.21.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

-

-

-

... More
(i) Ground Floor & First Floor

333

498620

1497.36

... More
(ii) Second Floor

167

252559

1512.33

... More
(iii) Third Floor

167

255060

1527.31

... More
Approximate cost of ISI marked oxidized iron fitting with screws for door & windows etc.(for estimate purpose only)

-

-

-

... More
(i) Ground Floor & First Floor

333

133200

400

... More
(ii) Second Floor

167

67468

404

... More
(iii) Third Floor

167

68136

408

... More
Renewing panes of Glass in doors, window & ventilators or fixing in the new work with 4 mm thick Glass panes fixed with brads and putty including supply of all materials, labour, Tools & plant etc. required for proper completion of the work.

-

-

-

... More
(i) Ground Floor & First Floor

211

112885

535

... More
(ii) Second Floor

106

57277

540.35

... More
(iii) Third Floor

106

57844

545.7

... More
Numbering of Flats with letter/no. writing including painting with one coat ready mixed priming paint and two coat or approved superior quality ready mixed paint or varnish including supply of all materials labour T&P etc.required for proper completion of work. =3x6=18

96

1968

20.5

... More
9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVCprofile), ,uPVC extruded glazing beads of appropriate dimension,EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc.

-

-

-

... More
After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) sqm 5399.70

35

181429

5183.71

... More
9.147D Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile),appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg),G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.

-

-

-

... More
(Single / double glass panes, wire mesh and silicon sealant shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 9.147D.1 Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) sqm 5608.60

240

1292220

5384.25

... More
Part B :-- Water Supply & Sanitation Work

-

-

-

... More
Providing & fixing GI pipes complete with GI fittings and clamps, including cutting & making good the walls etc.

-

-

-

... More
Internal work- Exposed on wall

-

-

-

... More
40 mm dia

240

90811

378.38

... More
25 mm dia

192

32440

168.96

... More
15 mm dia

144

14376

99.84

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 18.8.2 20 mm nominal outer dia Pipes

672

183765

273.46

... More
Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

96

211968

2208

... More
Providing and fixing on wall face unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A, including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
110 mm diameter pipe

208

61900

297.6

... More
90 mm diameter pipe

240

56448

235.2

... More
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
12.42.3 Single tee with door 12.42.3.2 110x110x110 mm each 181.55

96

16731

174.29

... More
12.42.3 Single tee with door 12.42.3.1 75x75x75 mm each 121.50

96

11197

116.64

... More
Bend 87.5 degree

-

-

-

... More
Plane short bend 90mm bend

24

2609

108.72

... More
Plane short bend110mm bend

24

3722

155.09

... More
Door short bend110mm bend

48

7444

155.09

... More
Providing and fixing rigid PVC Nahani trap of self cleaning design with complete i/c cost of cutting and making good the walls and floors.

-

-

-

... More
2) 110 mm inlet and 110 mm outlet.

192

23592

122.88

... More
Providing and fixing on wall face unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A, including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
110 mm diameter pipe

-

-

-

... More
(i) Ground Floor & First Floor

240

71424

297.6

... More
(ii) Second Floor

96

28855

300.58

... More
(iii) Third Floor

96

29140

303.55

... More
Providing and fixing on wall face unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A, including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
90 mm diameter pipe

-

-

-

... More
(i) Ground Floor & First Floor

480

112896

235.2

... More
(ii) Second Floor

192

45609

237.55

... More
(iii) Third Floor

192

46060

239.9

... More
Providing and fixing 90 mm dia Y junction heavy quality ISI marked including supply of all materials labour T&P etc.required for proper completion of work.

72

5291

73.49

... More
Providing and fixing 110 mm dia PVC terminal guard heavy quality ISI marked including supply of all materials labour T&P etc.required for proper completion of work.

24

1763

73.49

... More
Providing and fixing 90 mm dia PVC terminal guard heavy quality ISI marked including supply of all materials labour T&P etc.required for proper completion of work.

24

1763

73.49

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore

288

82667

287.04

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore

96

30689

319.68

... More
18.58 Providing and fixing PTMT grating of approved quality and colour.18.58.1 Circular type 18.58.1.1 100 mm nominal dia

288

9054

31.44

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. per litre 7.25UPVC Storage Tank

48000

230400

4.8

... More
Construction of brick masonry chamber of different internal size i/c s/o all material, labour T&P etc. reqd. for proper completion of work as per direction of E/I as per approved design & drawing of H.P.D.A. (A) 450x450x600 mm

24

72852

3035.52

... More
(B) 600x600x900 mm

24

132134

5505.6

... More
Addition or subtraction of ht of M.H. ofof different internal size manhole M-150 class B/W, 1:6 cement mortar, int. plaster 1:212, neat cement finished & 3 No. foot rest i/c s/o all mat lab. T&P etc. complete (A.R.)(0.60x0.60x1.00) m.

5

-20764

4152.96

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :testing of joints etc. complete : 19.1.2 150 mm diameter

48

50176

1045.34

... More
Providing and fixing gunmetal gate valve withCI wheel of approved quality (Screwed end)

-

-

-

... More
25mm nominal bore

96

39462

411.07

... More
Part C :-- Internal Electricfication Work

-

-

-

... More
Wiring point for light in PVC conduit with 1.5 sq. mm. FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit conduit partly concealed in the wall and partly laid slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash.

672

409920

610

... More
Same as Item No.1 but for Fan point.

192

128832

671

... More
Same as Item No.1 but Wiring point for call bell

96

54912

572

... More
Same as Item No.1 but for 5 Amp. Plug point.

576

188352

327

... More
Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x100 mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.

384

130560

340

... More
Supply and wiring of 2 nos 2.5 sq.mm. FR but in but in 25 mm dia heavy duty (2 mm thick) PVC conduit FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable partly concealed in wall & partly laid in slab along with reinforcement before concreting, with two number 14 SWG copperearth continuity wire including matching colour wash etc, complete in all respect

2160

468720

217

... More
Supply and wiring of submain with 2 nos 4 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in 25 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with two number 8 SWG GI earth continuity wire including matching colour wash etc.complete in all respect

2160

626400

290

... More
supply and fixing of 6AMP to 32 AMP MCB (10KA).CAT B

288

59328

206

... More
S & F surface/Flush mounting 8ways SPN distribution board without additional metal door without MCB complete in all respect, as direct by Engineer in Charge.Cat B

96

104640

1090

... More
S&F of 40 Amp. S.P. Isolator CAT B

96

24000

250

... More
S/F of PVC conduit pipe 25 mm dia in Roof and walls. Complete in all respect

480

24000

50

... More
159 Supply and fixing of switch box made up of 16 SWG (1.5 mm) thick M.S.sheet of 175 x 100 x 65 mm size duly painted with red oxide primer and flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge.

192

29952

156

... More
Supply and fixing of switch box made up of 16 SWG (1.5 mm) thick M.S.sheet of 100 x 100 x 65 mm size duly painted with red oxide primer and flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge.

96

9408

98

... More
1322 3 mm thick phenolic laminated sheet sq.cm 0.10

45018

4501

0.1

... More
Supply and burying of 40mm dia x 4.5 metres long G.I. pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30 cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer in charge complete in all respect as per drawing.

4

16304

4076

... More
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.

64

5760

90



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.