If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Hapur Pilakhua Development Authority - HPDA Tender

Works
Civil And Construction
Eprocure
Opening Date24 Dec 2023
Closing Date11 Jan 2024
Tender Amount₹ 63,04,087 
Notes
Download

Costs

Summary

Anand Vihar Yojana Mai Nirmit Kalindi Aparment K Bhawno Mai Lift Pani Supply Pump Common Passage Light Etc Lt Or Nirman Karya Or Park Ki Path Parkash Hetu Ek 10mtr Highmast Lgane Ka Karya

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc. PWD SOR 506 / 2018 (make - gloster, havells / universal/ polycab) 120 sq. mm 3 core

272

402560

1480

... More
Supplying and making of 120 sq. mm outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : :DSR SI No.10.5.1/2022 (20100-16.16%=16851.84)

4

67408

16852

... More
Supplying and making cable route marker with cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..DSR SI No.7.9/2022 (585-16.16%=490.05)

8

3920

490

... More
S/E of Double pole stucture ( FOR POLE / PLINTH MOUNTED TYPE TRANSFORMER TYPE SUBSTATION )12mt. long 410 SP-62 ST pole (259 Kg) support grouted in 1:3:6 (cement coarse sand 6 graded stone aggregate 40 mm nominal size) including 30 cm high plinthing from ground level with the cost of 3 no 100 x 50 x 6mm 2.24 Mr long Chanel and 3 no. 75 x 40 x 6mm 2.24 Mtr lon Chanel and With D.O. Fuse set , T.P.M.O. switch , anticlimbing device and paintig of pole Complete with all material lab. T&P etc required for proper completion of work or as direction of E/I. (AR) 2022

2

134180

67090

... More
Supply, Installation, Testing and commissioning of foiiowing size 11/0.433kv Aiuminium/copper wound distribution T/F Level-1or 2 Rating complete in all respect as per UPPCL approved makes and noms ( five star rating with 3 year warrenty after hand over ) (AR) 2023 400 Kva

2

1929358

964679

... More
Const. of T/F plinth size 1.5x1.5 & height over all 1.30 mt. made of 1st class B/W in 1:4 ( 1 cement & 4 coarese sand ) in foundation 100 PCC in 10:5:1 & top of the plinth 100 mm PCC in ratio 1:2:4 ( 1 cement 4 coarse sand & 4 stone ballast agreegate 4cm ) complete with 12mm Plaster all side and white Wash etc as per direction of E/I AR 2022

2

46350

23175

... More
Const. of feeder pillar plinth size 1.50 x 0.58 mt & Height 0.45 mt with 1st class B/W in 1:4 in foundatio 100mm PCC ratio 10:5:1 and on top 100m PCC in ratio 1:2:4 ( 1 cement 4 coarse sand & 4 stone ballast agreegate 4cm ) including plaster & white wash etc all complete. AR 2022

2

19064

9532

... More
Const. of fencing plinth clear inner size 4.5 x 7.0 x 0.45 mt. in 1st class B/W including plaster & providing M -150 Brick on edge floor laid dry joint sand filing including perpration base to proper slope..all complete in open space or as direction of E/I. AR 2022

2

70778

35389

... More
Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect.. SI No. 703 PWD SOR/18

10

53800

5380

... More
Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect.PWD SOR 705/2018

1

10450

10450

... More
Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PWD SOR 717/2018

200

30000

150

... More
Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect.PWD SOR 718/2018

50

55500

1110

... More
Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.(Rate analysis attached) SOR ((814 - 1021 C X CAT B )) * 2 + 821F (298200- 2(5010+8240) = 296420 ) ( make - L&T / siemens / havells / schenider ) Incoming 630 Amp. MCCB-1 Nos. Outgoing 200 Amp.MCCB-3 Nos. & 63Amp. 4 pole MCCB-1Nos.

2

592840

296420

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.PWD SOR 501/2018 ( make- gloster / havells / universal / polycab )

-

-

-

... More
150 sq. mm 3-1/2 core (957-170=787)

100

78700

787

... More
400 sq. mm 3-1/2 core (2048-170=1878)

60

112680

1878

... More
240 sq. mm 3-1/2 core (1379-170=1209)

210

253890

1209

... More
Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.PWD SOR 504/2018

-

-

-

... More
240 sq. mm

8

2176

272

... More
400 sq. mm

12

7152

596

... More
S/F of danger Board complete with clamps, bolts & nut complete in all respect as per direction of SOR S.I 1109/18

4

340

85

... More
Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.DSR/12.38 /22 (3606-16.16%=3023.27)

8

24184

3023

... More
Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.DSR/12.39 /22 (4907-16.16%=4114.29)

6

24684

4114

... More
Supplying and making cable route marker with cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..DSR SI No.7.9/2022 (585-16.16%=490.46.35)

4

1961

490.46

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR 14.16.2 / 14.16.3 / 22 (make dura-line / reck / line duct)

-

-

-

... More
120 mm dia (OD-120 mm & ID-103 mm nominal) (368-16.16%=308.53)

220

67876

308.53

... More
90 mm dia (OD-90 mm & ID-76 mm nominal) (290-16.16%=243.13)

250

60782

243.13

... More
63 mm dia (OD-63 mm & ID-51 mm nominal) (247-16.16%=207.08)

600

124248

207.08

... More
S/E of 150 sqmm X 3 C + 1 x 120 sqmm + 1 x 16sqmm XLPE insulated ABC bare messenger wire etc complete in all respect as per UPPCL approved makes and noms and as per direction of E/I AR 2018 ( iwoZ Lohd`r )

300

149400

498

... More
S/F of PG clamp/connector suitable for connecting of various sizes ABC cable including insulating cap etc complete as per direction of E/I. AR 2018

200

50000

250

... More
Supply and Fixing of Tape off box 125 Amp to 200 Amp TPN for Sandwich alumininum bus bar trunking complete in all respect. PWD SOR 930/2018

18

568800

31600

... More
Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.(Rate analysis attached) SOR No. 812 1020 A CAT-B (1720 X 2 = 3440+125700= 129140) ( make - L&T / siemens / havells / schenider ) Incoming 200 Amp. MCCB-1 Nos. Outgoing 63 Amp.MCCB-5 Nos.

1

129140

129140

... More
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.PWD SOR 501/2018 ( make- gloster / havells / universal / polycab )

-

-

-

... More
50 sq. mm 3.5 core (492-170=322)

135

43470

322

... More
25 sq. mm 3.5 core (373-170=203)

90

18270

203

... More
10 sq. mm 4 core (327-170=157)

300

47100

157

... More
16 sq. mm 2 core (311-170=141)

360

50760

141

... More
6 sq. mm 2 core (276-170=106)

350

37100

106

... More
Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.PWD SOR 504/2018

-

-

-

... More
16 sq. mm

24

504

21

... More
35 sq. mm

32

992

31

... More
50 sq. mm

28

1344

48

... More
25 sq. mm

16

432

27

... More
150 sq. mm

35

5110

146

... More
S&F of 320 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.PWD SOR 380/2018 ( make - L&T / siemens / havells )

1

17100

17100

... More
S&F of 32 Amp. 240 V DP metal clad rewireable type switch fuse unit on M.D.F.E.G. / Teak wood board complete in all respect.PWD SOR 305/2018 ( make - L&T / siemens / havells )

3

4320

1440

... More
Supply and erection of 63 Amp. TPN tap off box on rising mains complete with HRC fuses etc. complete in all respect. PWD SOR 913/2018 ( make - L&T / siemens / havells )

3

17145

5715

... More
S&F of 63 Amp. 4 pole MCB(10 KA) C Curve. CAT A PWD SOR 1020A/2018 ( make - L&T / siemens / havells )

3

6870

2290

... More
S & F surface/Flush mounting 4ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. CAT A PWD SOR1026 C/2018 ( make - L&T / siemens / havells )

3

25680

8560

... More
S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. CAT A PWD SOR1002 /2018 ( make - L&T / siemens / havells )

12

3120

260

... More
Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. PWD SOR1139 /2018

15

5100

340

... More
Supply and fixing of 2 metres high cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x 6mm angle iron frame having vertical members spaced at 1 to 1.25 mts and horizontal members spaced at 1 mt. The vertical members shall be grouted in floor and horizontal members in the wall to a depth of 300mm with ends forked. The cage shall have 2000mm x 1000mm size one leaf door with locking device having door frame fabricated with 35mm x 35mm x 6mm angle iron and 3mm expanded metal duly fixed with the cage member with hinges etc. The cage shall be painted with red oxide primer and synthetic enamel paint. The job includes all materials, labour, T&P etc. for proper completion of work PWD SOR 1142/2018

90

114750

1275

... More
Earth work in cutting or in embankment in ordinary soil excatavion to be in the form of regular pits not exceeding 0.50M in depth and earth work in embankment to be in 20 cm. layers including remming and dressing the surface to required levels and slopes and also including 1.50m. lift and 30 m. lead the earth from cutting to be used in making embankment or to be deposited as spoil bands with-in 30m. distance as directed by the Engineer incharge excluding Royallity. Wherever applicable for small work or abadi area. (Where machine can not reach/move) ( PWD Civil SOR 2022)SI no. 253a

1.45

145

100

... More
cement Concrete with 4 cm gauge approved stone ballast , coarse sand & cement and proportionof 4:2:1 including supply of all materials labour Tools & plants etc. requried for proper complition of work. 1x4.5x1.5x0.5 ( Rates PWD SOR Civil 279A/ 2022

2.5

17625

7050

... More
Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect CAT- AA PWD SOR 1402/2018 ( make - philips/ crompton/ bajaj havells / polycab )

260

299000

1150

... More
Supply and wiring of submain with two number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable t in 20mm dia. heavy duty (2mm thick) PVC conduit with one number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit, complete in all respect (SUB Main in Conduit on Surface) PWD SOR 1301C/2018

1500

186000

124

... More
Supply and fixing of 2/3/4 ways round PVC junction box confirming to ISS for 20mm dia PVC conduit concealed in wall, keeping its level upto plaster duly provided with proper size cover, screwed as directed at site by the Engineer I/C with supply of all the material, labour and T&P required for proper completion of work.PWD SOR 154 A/2018

260

6500

25

... More
Supply and wiring of 4 number 6 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2 mm thick) FRLSH PVC conduit with 2 nos 4 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect. PWD SOR 267 C /2018

200

72200

361

... More
S&F of 250 Amp 4 pole MCCB (25 KA) Thermal Magnetic release CAT A PWD SOR 1021 G/2018 ( make - L&T / siemens / havells )

1

21080

21080

... More
S & F surface/Flush mounting 4ways V TPN distribution board without additional Door without DPX3 160 MCCB complete in all respect, as directed at site by Engineer in charge. CAT A PWD SOR 1030/2018 ( make - L&T / siemens / havells )

1

9890

9890

... More
Construction of 125 Kvaq disel genrator set foundation complete with all materials , labour tool & Plant etc. in all respect as per dircetion engineer incharge. AR 2022

1

38792

38792.25

... More
Shifting of 125 kva DG set on foundation plinth by meen fo crain/ hydroulic liftor.( Rate taken from PWD sOR Civil 2017 Chaptor-2 SI No.-31 J.C.B. including POL & Driver)

2

1900

950

... More
Supply & fixing of 10 mtr GI Octagonal Pole of approved make (top dia 100mm, Bottom dia 200 mm and base plate 16mm thik) having 3 mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. PWD SOR 649/2018 ( 27920-1012=26908) (make - bajaj / crompton / philips)

1

26908

26908

... More
Supply and fixing of factory wried integral LED flood light luminaires having die cast aluminium body and diffuser with driver set suitable for 170 TO 200 Watt. Confirming to IP 66 and above Protection complete in all respects CAT- AAA PWD SOR S.I. No. 1455/2018 ( make - philips/ crompton/ bajaj havells)

4

91000

22750

... More
S/F of Rectanguler 50 x50 x6mm M.S. angle iron and 50x5mm M.S. flate iron pole top bracket for 4 No. flood light. AR 2018

1

2600

2600

... More
Supply and erection of 600 mm long cross arm of 50 mm x 50mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on poles complete in all respects including painting with aluminium paint. PWD SOR S.I. No. 625/2018

5

2855

571

... More
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 sq.mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit.,GP Box ,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed .PWD SOR 121C/2018

3

1713

571

... More
Wiring Point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in n PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. , GP Box and piano type switch and socket etc. complete in all respect. .PWD SOR 124C/2018

1

304

304

... More
Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect. CAT-AA .PWD SOR 1417/2018 ( make - philips / crompton/ bajaj / havells / polycab )

30

37500

1250

... More
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA PWD SOR 1413/2018 ( make - philips/ crompton/ bajaj / havells/ polycab )

3

3570

1190



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.