Greater Noida Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Greater Noida Industrial Development Authority - GNIDA Tender
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date8 Apr 2022
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 1,20,000Document Cost
₹ 1,780Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_GNIDA_685917_45Bid Award Id
ViewTender No
GM/(ENGG.)/2022/349 DATE-06-04-2022Tender Authority
Greater Noida Industrial Development Authority ViewPurchaser Address
-Website
http://https://www.greaternoidaauthority.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
(DSR/2013/15.25/P-250)
50
-
88.5
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge
In cement mortar
(DSR2013/15.7.4/P-248)
6
-
681
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:-
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
(DSR-2013/4.1.8/P-85)
16
-
3920.65
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
(DSR-2013/6.1.1/P-111)
19
-
4847.85
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
(DSR-2013/6.4.1/P-111)
42
-
5526.5
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
(DSR-2013/5.3/P-96)
22.5
-
6107.15
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:1½:3 (1 Cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)
(DSR-2013/4.1.2/P-85)
10
-
5317.75
12 mm thick plaster with cement and coarse sand in 1:4cement mortor over brick work minimum thickness not to be than 1cm including supply of all materials , labour tool & plants etc. work.
(DSR-2013/13.4.1/P-222)
81
-
153.85
15 mm thick plaster with cement and coarse sand in 1:4cement mortor over brick work minimum thickness not to be than 1cm including supply of all materials , labour tool & plants etc. work.
(DSR-2013/13.5.1/P-222)
81
-
178.6
6 mm cement plaster of mix : 13.16.1 1:3 (1 cement : 3 fine sand) (DSR-2013/13.16.1/P-223)
20
-
120.35
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
-
-
-
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height including
cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
-
-
-
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge including laying glass fibre cloth of approved quality
in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm
(DSR-2013/22.7.1/P-381)
20
-
882.6
Centering and shuttering including strutting, propping etc. and removal of form for :
Suspended floors, roofs, landings, balconies and access
platform (DSR-2013/5.9.3/P-97)
20
-
371.8
Centering and shuttering including strutting, propping etc. and removal of form for :
Lintels, beams, plinth beams, girders, bressumers and cantilevers
(DSR-2013/5.9.5/P-97)
25.5
-
309.8
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) (DSR-2013/13.44.1/P-225)
56
-
54.4
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes
(DSR-2013/18.7.2/P-319)
60
-
182.15
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes (DSR-2013/18.7.1/P-P-319)
50
-
155.8
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR-2013/18.48/P-327)
2000
-
6.3
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :18.17.1A 20 mm nominal bore (DSR-2013/18.17.1/P-321)
2
-
427.8
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.2 20 mm nominal bore each
(DSR-2013/18.18.2/P-321)
2
-
407.4
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.2 Granite of any colour and shade 8.2.2.2 Area of slab over 0.50 sqm sqm
(DSR-2013/8.2.2.2/P-128)
34.5
-
3769.7
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick
(DSR-2013/11.26.1/P-190)
18
-
1071.7
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Thermo-Mechanically Treated bars./Cold twisted bars
(DSR-2013/ 5.22.6/P-99)
5102.5
-
66.5
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
(DSR-2013/10.25.2/P-179)
500
-
86.5
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR-2013/21.1.2.2/P-371)
98.5
-
397.75
Providing and fixing brass stop cock of approved quality : 15 mm nominal bore (DSR-2013/18.16.1/P-321)
5
-
259.85
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) sqm 1296.4
(DSR-2013/21.3.2 /P-371)
43
-
1009
Filling availble excatvated earth (Excluding rock) in trenches plinth side of foundation etc. layers not exceeding 20 cm. in depth side of foundation etc. layers not exceeding 20 cm. in deptheach deposited layer by ramming and watering lead upto 50m and lift upto 1.5m consolidating (AR/GNIDA)
115
-
54.03
Providing and Fixing C.N.G Crimination Furnance Scheme details of work and Scope of work for CNG fired Furnance:CNG Cremation Furnance:-The Cremation Furnance designed, supply , Installation, Testing and Commissioning manufacture in such a way that each furnace efficient working in minimum time cremation. Generally a maximum temperature of 850oC to 1100 can be brought, though the operating temperature required is 550oC. With double chambers, One primary other secondary and 2 burners are required for each furnace:-
-
-
-
i) Overall size :- 3500mm(L) X 3500mm(H) X 2000mm(W)
II) Working Chamber size (inside) :- 2725mm(L)830mm(H) X 900mm(W)
III) Frame make with MS Steel Structural with U Channel SAIL/equivalent size:- 75mm x 5mm. Front Doors mechanical drive system and counter weight etc. The Front doors made of MS base Sheet 2mm and laminated SS 304 0.7mm in front side sheet duly fabricate the frame of MS angle/channel fill with high complete insulation material with 1" fiber insulation board and SS road 8mm inside for hold the insulation door operation material.
Consist of Front door pressing handle of 190mm (dia) chrome plated handle and 16mm thickness.
Consist of Front gate screws and castions nuts having 350mm length x 40mm diameter.
-
-
-
Provided with gate pulleys 2 Nos having diameter 300mm x 25mm thk x 50mm ID of 10x5mm provided with big Gears duplex 250mm diameter x 30mm thk provided with small gear bottom size with 100mm x 30mm thk safety guard for driving end of door. Consist of main shaft of 1600mm long x 50mm dia with key ways, and plummer block having sizes of 50mm and 30mm of Reputed make SKF/FAG. Refractory lining of the surface and Insulation. Hot face insulation bricks, Ceramic Fibre, dead body support will be CNG Furnace with dual chamber primary and secondary.
-
-
-
Highly efficient insulation for maintain the temperature with 6 step in be used of 70% fire bricks (Mahakoshal/equivalent) 40% fire bricks good quality, light weight insulation brick, 1" fiber insulation board good quality , red bricks with plaster and frame work with fiber insulation and 105mm MS sheet with red oxide and heat resistance aluminium paint of proper thickness that is 570mm shall be provided in order to operate the furnace with minimum gas consumption and lost the temperature burner block and dead body supporter should be used (Burner Block size :- 225mm x 225mm or 300mm x )
-
-
-
Dead Body supporter size:- 600mm x 300mm x 75mm) reputed make Mahakoshal / Equivalent 70% (centre two no 100mm) Track and charging Trolly made by section of size 100mm x 50mm x 5mm channel provided with complete arrangements for uplift and lowering of body, provided with C.I Wheels side plate assembly 1000mm long x 50mm width having wheels plate of size 190mm x 10mm thk provided with guided wheels size 80mm x 20mm (thk) complete with pins. Chimney 30000mm (30mtr) height foundation for chimney size :- 2300mm (W) x 4200mm(L) x 500mm(H)
-
-
-
I) Foundation bolts L-Type:- 32mm (dia) x 2200mm(L) x with nuts and washer x 150mm long thread. Cone MS Cone 1200mm bottom dia x 10mm thickness x 3000mm height
i) base plate:- 1500mm x 1500mm x 25mm thick
ii) Top size of cone welded with 25mm thick flange suitable for fixing with pipe.
iii) Service window 600mm x 600mm
iv) Ribs: 15 Nos : 600mm x 200mm x 10mm 1816:16B318:2215:2216:2215:22
Pipe Jindal/Equivalent reputed make 300mm dia x 6mm thick with 18mm flange welded both sides, havings 20mm dia holes suitable for fixing 18mm dia high tensile bolts.
i) Having 15 Nos of ribs 125mm x 100mm x 10mm thick with top safety cap.
-
-
-
Ladder with safety cage
Monkey type ladder with 40x5MS Angle
Plate form 02 Nos for Smoke Testing.
MS Chimney structure duly painted with heat resistance aluminium paint bottom to top. Base made of 4mm wire mesh, having spring std 1000mm(H) x 1400mm(W) & top of GI earthing strip 32mm with arrester with indication avaition light. SS Wet Scrubber for Gases and pollution control size 800 x 500 x 500 total 2300mm (L) with SS 304 horizontal round shape. Wet Scrubber will be provided for gases for pollution control size of based dia 800mm x 2.5mm thick x 1200mm(L) cone 500mm 10"NB x 8mm SS 304 Sprinkler 5mm 8Nos with copper fitting and SS Socket 2Nos baffle plate 2Nos 800mm x 25mm hole x 50mm pitch thick 205mm outlet pipe lines, valves and necessary pumping unit fitted on water tank, minimum 1000 Lt capacity pvc head tank for each unit furnace. Internal Gas pipe Lines all the internal pipelines 2" seamless 3.5mm jindal and equivalent reputed make will be welded with leak prove gasket as per the norms of IGL. Piping of Gas line from IGL source to Furnace with power failure safety value and by pass system.
-
-
-
Gas Train
Gas Train would be fitted in Main Gas pipeline to reduce the pressure by fitting the regulator, gauges, hose pipes, steel nipples, S.S valves, Pressure switch etc. Electrical Control panel for CNG Furnace auto ignition and temp. Electrical control panel size:- 1000mm(L) x 300mm(D) x 750mm(W) with heat removing inside of control panel with 3 phase over load MCB COT OFF, individual 3 phase MCB, cONTROL MCB I.D fan contactor & amp, Over load presuure cot/off on/off switch, indication LED, Flame Failure Buzzer, Buzzer Burner AUTO/MANUAL Rely, Volt/Ampere/Hz. Indicator,
Body Type :- BodyM.S 2.5mm thick with red oxide and painted
-
-
-
Temperature Controller 0- 1200 Deg Centigrade, Thermocouple and compensating Lead, Out put warning etc. Suitable Burner for primary chamber ECCS MAKE/Equivalent reputed make CNG GAS FAIRD FULY AUTOMATIC BURNER In belt Blower single phase, Auto Ignition, Ignition Electrode, Auto Sequence Controller suitable Burner for secondary chamber ECCS MAKE/Equivalent reputed with flame failure sensor, Air detecting pressure switch, Slow opening & amp, first closing solenoid valve & amp. Diffuser Firing head blast tube S.Steel make with Mounting Flange CI, ms Sheet powder Coated Body. Heavy duty 5 HP ID Blower fitted in scrubber to chimney, Blower size dia:- 840mm x 380mm
CFM:- 7000
Motor :- 5HP 3 Phase Compton Make
RPM:- 1440
Body Dia:- 840mm
Inlet/Outlet :- 250mm
-
-
-
Provided with gate pulleys 2 Nos having diameter 300mm x 25mm thk x 50mm ID of 10x5mm provided with big Gears duplex 250mm diameter x 30mm thk provided with small gear bottom size with 100mm x 30mm thk safety guard for driving end of door. Consist of main shaft of 1600mm long x 50mm dia with key ways, and plummer block having sizes of 50mm and 30mm of Reputed make SKF/FAG.Refractory lining of the surface and Insulation Hot face insulation bricks, Ceramic Fibre, dead body support will be CNG Furnace with dual chamber primary and secondary.
-
-
-
Highly efficient insulation for maintain the temperature with 6 step in be used of 70% fire bricks (Mahakoshal/equivalent) 40% fire bricks good quality, light weight insulation brick, 1" fiber insulation board good quality , red bricks with plaster and frame work with fiber insulation and 105mm MS sheet with red oxide and heat resistance aluminium paint of proper thickness that is 570mm shall be provided in order to operate the furnace with minimum gas consumption and lost the temperature burner block and dead body supporter should be used (Burner Block size :- 225mm x 225mm or 300mm x ) Dead Body supporter size:- 600mm x 300mm x 75mm)
-
-
-
reputed make Mahakoshal / Equivalent 70% (centre two no 100mm) Track and charging Trolly made by section of size 100mm x 50mm x 5mm channel provided with complete arrangements for uplift and lowering of body, provided with C.I Wheels side plate assembly 1000mm long x 50mm width having wheels plate of size 190mm x 10mm thk provided with guided wheels size 80mm x 20mm (thk) complete with pins. Chimney 30000mm (30mtr) height foundation for chimney size :- 2300mm (W) x 4200mm(L) x 500mm(H)
-
-
-
I) Foundation bolts L-Type:- 32mm (dia) x 2200mm(L) x with nuts and washer x 150mm long thread.
-
-
-
MS Chimney structure duly painted with heat resistance aluminium paint bottom to top. Base made of 4mm wire mesh, having spring std 1000mm(H) x 1400mm(W) & top of GI earthing strip 32mm with arrester with indication avaition light. SS Wet Scrubber for Gases and pollution control size 800 x 500 x 500 total 2300mm (L) with SS 304 horizontal round shape.
-
-
-
Wet Scrubber will be provided for gases for pollution control size of based dia 800mm x 2.5mm thick x 1200mm(L) cone 500mm 10"NB x 8mm SS 304 Sprinkler 5mm 8Nos with copper fitting and SS Socket 2Nos baffle plate 2Nos 800mm x 25mm hole x 50mm pitch thick 205mm outlet pipe lines, valves and necessary pumping unit fitted on water tank, minimum 1000 Lt capacity pvc head tank for each unit furnace. Internal Gas pipe Lines all the internal pipelines 2" seamless 3.5mm jindal and equivalent reputed make will be welded with leak prove gasket as per the norms of IGL. Piping of Gas line from IGL source to Furnace with power failure safety value and by pass system.
1
-
4607900
Add labour cess @ 1% on all above items
5930098.35
-
0.01