Greater Noida Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Greater Noida Industrial Development Authority - GNIDA Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date8 Apr 2022
Closing Date18 Apr 2022
Tender Amount₹ 29,17,317
Costs
EMD
₹ 82,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_GNIDA_685917_2Bid Award Id
ViewTender No
GM/(ENGG.)/2022/349 DATE-06-04-2022Tender Authority
Greater Noida Industrial Development Authority ViewPurchaser Address
-Website
http://https://www.greaternoidaauthority.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
3C x 6 Sqmm
20
-
48
... More
Supply and fixing of High power LED street light fitting on pole complete in all respect with following technical specification.
-
-
-
... More
Electrical Specifications (LED Driver)
Parameter: 35 to 40 W LED
Input voltage: AC 140 to 310 V AC with Auto restting safety cut-off.
Input Frequency: 50Hz to 60HZ
Power Factor: 0.95
Usage Hours: Dusk to Down (12 Hours)
Drive Current: 700MA
Drive Efficiency: 85%
-
-
-
... More
IEC Compliance: Confirming to IEC-61347-1&IEC 61347-2-13, IEC 61547, 610-3-2, CISPR-15
Control Gear: Integral Design (Tested & Certified for performance & safety mandatory from Government approved lab).
-
-
-
... More
Total Harmonic distortion:
THD (i) : 10%
Working Temp: -20C to 45C
LED Luminaire Specifications: Life Expectancy: Equal or more than 50000 burning hrs. minimum 70% lumen maintenance @ Ta 25C
Colour Temp: 5700K + 300K
Colour Rendering
Index: 70 + 2
-
-
-
... More
Lumen/Watt: 110 lum/W
Make of LED source: High Power LED - CREE/Philips/Osram/Nischia
LED wattage: LED's should be high-power LED's from 1W to 5W
Electrical Connector: Armoured 2 core 1.5Sqmm cable of 0.3 mtr. should be provided
Surge Protection: Min 5KV inbuilt with driver & 10KV external to driver inside the fixture.
-
-
-
... More
Lamp Housing: The body shall be robust, corrosion resistant superior in finish & without any cracks or through holes, made in a single piece by high pressure die cast LM6 aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust tight & water proof. The luminaries shall be class-I luminary. Degree of protection shall be IP65 as defined in Appendix-A of IS10322 (Part-I 1982) with latest amendments.
-
-
-
... More
Heat Sink/Dissipation:
Integrated with in luminaire & the dimensions of luminaries shall be adequate to permit sufficient heat dissipation through the body it self, so as to prevent abnormal temperature rise inside the lantern & consequential damage to cover & gasket materials, LED's lenses & Electronic Driver.
-
-
-
... More
Driver:
Drivers should be constant current drivers with separate compartment, preferable top maintaible for ease of maintenance, also driver compartment should be minimum IP65. Driver should also have double phase protection, no load open circuit and short circuit protection.
-
-
-
... More
Optical System:
The optical system will consists of individual PC/PMMA lenses on high power LED's designed & tested to achieve typical street lighting distribution from the LED lantern. This is to ensure maximum utilisation of light flux on the carriageway and minimum glare on the footpath side of the lantern and also in the direction of vehicular traffic.
-
-
-
... More
Covers:
Toughened glass. It shall not get discoloured shall not suffer degradation due to heat and ageing. The cover shall preferably be secured with stainless screws should conform with minimum IP65 class.
-
-
-
... More
Gasket:
Gasket: A extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV glass cover and the metal housing to exclude the entry of dust, water, insects, etc. When the luminaries is closed should conform with minimum IP65 class. Felt gasket will not be accepted.
-
-
-
... More
Junction Temp: 85
Luminaire system efficiency:
110lm/W lumens/watt (supported by LM79 test report from NABL approved lab.
Index of Protection Level: IP65 or Higher.
Manufactures Logo: Manufactures world Mark/Name Engraved/Embossing on die cast housing to allow tracibility/authenticity till life of fixture (Stickering/Printing not allowed).
-
-
-
... More
Technical Suitability
Test Reports:
Photobiological test report for safety.
Type test reports are is 10322 from Government approved lab approved from Ministry of Science Government of India.
LM80 report from the source manufacturer for LED's used.
ROH's certificate for the LED.
8
-
3470
... More
Supply, delivery, testing, laying of Al. conductor HDPE/XLPE insulated 1100V grade Arial Bunched Cable with Messenger wire as below on pole complete in all respect. [CCI (Mumbai/Nasik), Fort Gloster (Kolkata), Asian (Thane/Silvasa), Universal (Satna), Nicco (Kolkata/Baripara), ICL (Rajpura), Diamond, Havells, Kalinga, Suraj, Delton, Grandley & Polycab make can be used] (SOR-50)
-
-
-
... More
3C x 25 Sqmm + 1Cx16 Sqmm + 35 Sqmm massanger (As per SOR-50/AR)
290
-
229
... More
S/F of 63 Amp 415V metal clad TP HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. (PS-323)
1
-
3050
... More
S/F of ‘D’ clamp of 50x6 mm flat iron on steel tubular poles/steel rail pole with nut & bolts etc. complete in all respects, including painting with aluminium paint (PS-623)
20
-
170
... More
S/F of 40mm dia 1.5 mtr long G.I. pipe B class bracket with 2 nos ‘D’ clamps 50x6mm flat iron on steel tubular pole/steel rail pole/PCC pole with bolts, nuts etc. complete in all respect (A.R.)
10
-
751
... More
Supply & erection of end clamp (J-hook) (AR)
10
-
250
... More
Supply & erection of screw tightener (AR)
20
-
404
... More
S/F of Suspension clamp with insulated suitable ABC arial bunched conductor complete in all respect (AR)
10
-
100
... More
Supply, installation, testing & commissioning of 16mtrs. High mast System in two section for 50m/sec. Wind speed foundation, bolts, feeder pillar & other accessories foundation, erection, testing & commissioning of 16mtr High Mast System with 8 Nos (150-160W) LED flood light fitting Lumens 16000 lms (Typ) High Efficiency (Standard) LED fitting, Voltage: 100-240 V AC, Power factor: 0.90, Power: 150W, CRI: 70, Lumens: 16000 lms (Typ) CCT: 5000K, warranty 3 years (M.R.) (160Watt x 8 Nos LED fitting), Supply 160 Mtr. High mast Shaft in three section for 50M/Sec. wind speed, foundation bolts feeder pillar & other accessories, foundation, erection, testing & commissioning of 16mtr High Mast System.
Thickness: Top - 3mm, Middle-4mm, Bottom-4mm (AR)
1
-
457882
... More
Supply & laying of aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [CCI (Mumbai/Nasik), Fort Gloster (Kolkata), Asian (Thane/Silvasa), Universal (Satna), Nicco (Kolkata/Baripara), ICL (Rajpura), Diamond, Havells make] & for small works upto value of cable for Rs. 25.0 Lacs Kalinga (Gold), Suraj, Delton, Grandly & Polycab make can be used) (PS-501) (SOR-1)
-
-
-
... More
3.5C x 35 Sqmm
20
-
371
... More
3.5C x 50 Sqmm
200
-
541
... More
S/L of 90mm dia DWC pipe for drawing of power cable across the road by drilling of 120mm dia at 1 mtr. below the road level thereby doing the work of providing DWC pipe by trenchless method (SOR-55)
50
-
714
... More
Supply & fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, making connections etc. complete in all respects as per direction of the Engineer-in-charge. (PS-504) (SOR-214)
-
-
-
... More
50 Sqmm
6
-
46
... More
35 Sqmm
2
-
26
... More
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
3½ x 35 Sqmm (32mm) [DSR(E&M)-2013/9.1.21/P-29]
2
-
245
... More
3½ x 50 Sqmm (35mm) [DSR(E&M)-2013/9.1.22/P-29]
2
-
286
... More
Supplying, fixing & installation of hot press moulded SMC Sintex, feeder pillar box for street light of size 1040x730x290mm duly hinged with locking arrangement, fitted with 200 Amp copper bus bar of size 25mm x 3mm of suitable length. The feeder pillar shall consist of astronomical timer switch Astro Rex D-21, MDS make with 63 Amp 4 pole contractor MCX-21 L&T make, 4 Nos 63 Amp. & one no. 6 Amp. MCB, MD smale one 4 pole 100 Amp. isolator, L&T make one no. 4 pole 125 Amp. MCCB L&T make with internal wiring and all items to be fitted on channel inside the feeder pillar. The feeder pillar to be installed on plinth/angle iron frame as per requirement of site. (SOR-56)
1
-
15841
... More
S/F of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 Mtr. below ground level complete with 20 mm dia G.I. pipe & funnel for watering & one earthing lead of one no. 8 to SWG GI wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of GI pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of char-coal/coke & salt atleast 150 mm thick all-around etc. as per direction of Engineer-in-charge complete in all respects. (PS-702)
4
-
4035
... More
Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required. [DSR(E&M)-2013/5.15/P-23]
20
-
133
... More
Part-2
Providing and fixing High mast in villages Mandi Shyam Nagar, Rampur Mazra & Kherli Hafizpur
-
-
-
... More
BOQ-A: Villages Mandi Shyam Nagar & Kherli Hafizpur
-
-
-
... More
Supply, installation, testing & commissioning of 30mtrs. High mast pole of approved make with rising system in three section suitable for 50m/sec wind speed along with hot dip galvanised inside & outside, having pole sheet thickness 4mm top dia minimum 150mm, bottom dia minimum 600mm, base plate 840mm x 32mm thick, suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame luminaire carriage suitable for carrying/mounting 24 nos. LED flood light fixtures & its control gear boxes, 1.5 HP Power tool motor, 3 point suspension system with steel wire rope 8mm dia, double drum winch including making suitable foundation as per site requirement along with foundation bolts, nuts, washers, anchor plates etc. complete in all respect as per direction and satisfaction to the Engineer-in-charge (AOR attached)
2
-
937015
... More
Supply & laying of aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [CCI (Mumbai/Nasik), Fort Gloster (Kolkata), Asian (Thane/Silvasa), Universal (Satna), Nicco (Kolkata/Baripara), ICL (Rajpura), Diamond, Havells make] & for small works upto value of cable for Rs. 25.0 Lacs Kalinga (Gold), Suraj, Delton, Grandly & Polycab make can be used) (PS-501) (SOR-1)
-
-
-
... More
3.5C x 25 Sqmm.
180
-
332
... More
S/L of 90mm dia DWC pipe for drawing of power cable across the road by drilling of 120mm dia at 1 mtr. below the road level thereby doing the work of providing DWC pipe by trenchless method (SOR-53)
30
-
934
... More
Supply & fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, making connections etc. complete in all respects as per direction of the Engineer-in-charge. (PS-504) (SOR-214)
-
-
-
... More
16 Sqmm.
6
-
17
... More
25 Sqmm.
18
-
24
... More
Supply and fixing of brass nickel plated compression gland for PVC insulated and armoured served seathed under ground cable in cladding rubber ring etc. complete in all respect. The armouring of cable shall be properly connected with the earth as per direction of E/I. (PS-503) (SOR-213).
-
-
-
... More
3.5C x 25 Sqmm
6
-
92
... More
Supply and fixing of High power LED Flood light fitting on pole complete in all respect with following technical specification.
-
-
-
... More
Electrical Specifications (LED Driver)
Parameter: 250-260 W LED Flood Light
Input voltage: AC 140 to 310 V AC with Auto restting safety cut-off.
Input Frequency: 50Hz to 60HZ
Power Factor: 0.95
Usage Hours: Dusk to Down (12 Hours)
Drive Current: 700MA
Drive Efficiency: 85%
-
-
-
... More
IEC Compliance: Confirming to IEC-61347-1&IEC 61347-2-13, IEC 61547, 610-3-2, CISPR-15
Control Gear: Integral Design (Tested & Certified for performance & safety mandatory from Government approved lab).
-
-
-
... More
Total Harmonic distortion:
THD (i) : 10%
Working Temp: -20C to 45C
LED Luminaire Specifications: Life Expectancy: Equal or more than 50000 burning hrs. minimum 70% lumen maintenance @ Ta 25C
Colour Temp: 5700K + 300K
Colour Rendering
Index: 70 + 2
-
-
-
... More
Lumen/Watt: 110 lum/W
Make of LED source: High Power LED - CREE/Philips/Osram/Nischia
LED wattage: LED's should be high-power LED's from 1W to 5W
Electrical Connector: Armoured 2 core 1.5Sqmm cable of 0.3 mtr. should be provided
Surge Protection: Min 5KV inbuilt with driver & 10KV external to driver inside the fixture.
-
-
-
... More
Lamp Housing: The body shall be robust, corrosion resistant superior in finish & without any cracks or through holes, made in a single piece by high pressure die cast LM6 aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust tight & water proof. The luminaries shall be class-I luminary. Degree of protection shall be IP65 as defined in Appendix-A of IS10322 (Part-I 1982) with latest amendments.
-
-
-
... More
Heat Sink/Dissipation:
Integrated with in luminaire & the dimensions of luminaries shall be adequate to permit sufficient heat dissipation through the body it self, so as to prevent abnormal temperature rise inside the lantern & consequential damage to cover & gasket materials, LED's lenses & Electronic Driver.
-
-
-
... More
Driver:
Drivers should be constant current drivers with separate compartment, preferable top maintaible for ease of maintenance, also driver compartment should be minimum IP65. Driver should also have double phase protection, no load open circuit and short circuit protection.
-
-
-
... More
Optical System:
The optical system will consists of individual PC/PMMA lenses on high power LED's designed & tested to achieve typical street lighting distribution from the LED lantern. This is to ensure maximum utilisation of light flux on the carriageway and minimum glare on the footpath side of the lantern and also in the direction of vehicular traffic.
-
-
-
... More
Covers:
Toughened glass. It shall not get discoloured shall not suffer degradation due to heat and ageing. The cover shall preferably be secured with stainless screws should conform with minimum IP65 class.
-
-
-
... More
Gasket:
Gasket: A extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV glass cover and the metal housing to exclude the entry of dust, water, insects, etc. When the luminaries is closed should conform with minimum IP65 class. Felt gasket will not be accepted.
-
-
-
... More
Junction Temp: 85
Luminaire system efficiency:
110lm/W lumens/watt (supported by LM79 test report from NABL approved lab.
Index of Protection Level: IP65 or Higher.
Manufactures Logo: Manufactures world Mark/Name Engraved/Embossing on die cast housing to allow tracibility/authenticity till life of fixture (Stickering/Printing not allowed).
-
-
-
... More
Technical Suitability
Test Reports:
Photobiological test report for safety.
Type test reports are is 10322 from Government approved lab approved from Ministry of Science Government of India.
LM80 report from the source manufacturer for LED's used.
ROH's certificate for the LED.
-
-
-
... More
Key Features
High Reliability
Sleek innovative & Aero dynamic architectural design for better thermal management Energy efficient - saving upto 50% Luminaire efficacy 100 Im/W potted Driver is used to have a vibration proof performance
Provided with individual surge Suppressor 5KV.
-
-
-
... More
Product Specification
Parameters 250-260W LED Rated System Wattage - 250W
IP Protection - IP 66, Class-I
Driver - Integral (inbuilt 4KV SPD)
Driver Efficiency 90%
System Efficacy 100 Im/W
Operating Range - 120-270V 50Hz
THD 10%
PF 0.95
Surge protection - 5KV
CCT-5700KANSI
CRI 70
48
-
14135
... More
Supplying, fixing & installation of hot press moulded SMC Sintex, feeder pillar box for street light of size 1040x730x290mm duly hinged with locking arrangement, fitted with 200 Amp copper bus bar of size 25mm x 3mm of suitable length. The feeder pillar shall consist of astronomical timer switch Astro Rex D-21, MDS make with 63 Amp 4 pole contractor MCX-21 L&T make, 4 Nos 63 Amp. & one no. 6 Amp. MCB, MD smale one 4 pole 100 Amp. isolator, L&T make one no. 4 pole 125 Amp. MCCB L&T make with internal wiring and all items to be fitted on channel inside the feeder pillar. The feeder pillar to be installed on plinth/angle iron frame as per requirement of site. (SOR-56)
2
-
15841
... More
S/F of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 Mtr. below ground level complete with 20 mm dia G.I. pipe & funnel for watering & one earthing lead of one no. 8 to SWG GI wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of GI pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of char-coal/coke & salt atleast 150 mm thick all-around etc. as per direction of Engineer-in-charge complete in all respects. (PS-702)
6
-
4035
... More
Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required. [DSR(E&M)-2013/5.15/P-23]
30
-
133
... More
BOQ-B: Villages Rampur Mazra
-
-
-
... More
Supply, installation, testing & commissioning of 16mtrs. High mast System in two section for 50m/sec. Wind speed foundation, bolts, feeder pillar & other accessories foundation, erection, testing & commissioning of 16mtr High Mast System with 8 Nos (150-160W) LED flood light fitting Lumens 16000 lms (Typ) High Efficiency (Standard) LED fitting, Voltage: 100-240 V AC, Power factor: 0.90, Power: 150W, CRI: 70, Lumens: 16000 lms (Typ) CCT: 5000K, warranty 3 years (M.R.) (160Watt x 8 Nos LED fitting), Supply 160 Mtr. High mast Shaft in three section for 50M/Sec. wind speed, foundation bolts feeder pillar & other accessories, foundation, erection, testing & commissioning of 16mtr High Mast System.
Thickness: Top - 3mm, Middle-4mm, Bottom-4mm (AR)
1
-
457882
... More
Supply & laying of aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [CCI (Mumbai/Nasik), Fort Gloster (Kolkata), Asian (Thane/Silvasa), Universal (Satna), Nicco (Kolkata/Baripara), ICL (Rajpura), Diamond, Havells make] & for small works upto value of cable for Rs. 25.0 Lacs Kalinga (Gold), Suraj, Delton, Grandly & Polycab make can be used) (PS-501) (SOR-1)
-
-
-
... More
4 C x 16 Sqmm
120
-
314
... More
Supply & fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, making connections etc. complete in all respects as per direction of the Engineer-in-charge. (PS-504) (SOR-214)
-
-
-
... More
16 Sqmm.
12
-
17
... More
Supply and fixing of brass nickel plated compression gland for PVC insulated and armoured served seathed under ground cable in cladding rubber ring etc. complete in all respect. The armouring of cable shall be properly connected with the earth as per direction of E/I. (PS-503) (SOR-213).
-
-
-
... More
2C x 16 Sqmm
3
-
82
... More
Supplying, fixing & installation of hot press moulded SMC Sintex, feeder pillar box for street light of size 1040x730x290mm duly hinged with locking arrangement, fitted with 200 Amp copper bus bar of size 25mm x 3mm of suitable length. The feeder pillar shall consist of astronomical timer switch Astro Rex D-21, MDS make with 63 Amp 4 pole contractor MCX-21 L&T make, 4 Nos 63 Amp. & one no. 6 Amp. MCB, MD smale one 4 pole 100 Amp. isolator, L&T make one no. 4 pole 125 Amp. MCCB L&T make with internal wiring and all items to be fitted on channel inside the feeder pillar. The feeder pillar to be installed on plinth/angle iron frame as per requirement of site. (SOR-56)
1
-
15841
... More
S/F of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 Mtr. below ground level complete with 20 mm dia G.I. pipe & funnel for watering & one earthing lead of one no. 8 to SWG GI wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of GI pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of char-coal/coke & salt atleast 150 mm thick all-around etc. as per direction of Engineer-in-charge complete in all respects. (PS-702)
3
-
4035
... More
Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required. [DSR(E&M)-2013/5.15/P-23]
15
-
133
... More
Add labour cess @ 1% on all above items
4025130
-
0.01
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements