Greater Noida Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Greater Noida Industrial Development Authority - GNIDA Tender
Civil And Construction
Eprocure
Opening Date23 Dec 2022
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 2,94,000Document Cost
₹ 2,650Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_GNIDA_761624_23Bid Award Id
ViewTender No
GM/(ENGG.)/2022/402 DATE- 16-12-2022Tender Authority
Greater Noida Industrial Development Authority ViewPurchaser Address
-Website
http://https://www.greaternoidaauthority.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Carriage/disposal of earth/material by mechanical transport including loading, unloading and stacking. (AR/GNIDA). Earth:
-
-
-
All leads
11226.94
-
84.45
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). (DSR-13/16.2/P-262)
2856.5
-
9.3
Supplying and stacking at site:
-
-
-
90 mm to 45 mm size stone aggregate (AR/GNIDA)
727.67
-
1147.55
63 mm to 45 mm size stone aggregate (AR/GNIDA)
511.14
-
1205.6
53 mm to 22.4 mm size stone aggregate (AR/GNIDA)
511.14
-
1263.7
Supplying and stacking of moorum at site (AR/GNIDA)
102.2
-
809.7
Laying spreading and compacting stone aggregate of specified sizes to WBM specifications including spreading in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fill up interstices of coarse aggregate watering and compacting to the required density. (DSR-13/16.4/P-262)
1749.95
-
388.85
Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With bricks of class designation-150 (DSR-13/16.7.1/P-262)
1970
-
126.75
Earth work in excavation in ordinary soil in all type of foundation trenches including dressing of the side and ramming of bottom. Lifts upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m. All kinds of soil. (MORTH/A.R./GNIDA)
-
-
-
Depth from 0.0 to 1.5 M below G.L.
155.52
-
109.26
Providing and carting of following dia RCC hume pipe S&S NP-3 class & specials in site of work lowering the same into trenches in depth upto 1.50m below G.L. true to alignment jointing with 1:2 cement mortar in coarse sand including excavation of earth below invert level of pipe. (A.R./GNIDA)
-
-
-
250mm dia NP-3 pipe
192
-
437.56
Providing and applying tack coat on the prepared surface, heating bitumen in boiler and spraying the bitumen of 80/100 with spray set fitted on bitumen boiler including cleaning, preparing the existing road surface as per specifications. (MORTH-502/AR/GNIDA)
-
-
-
On granular base such as WBM and WMM surface with 7.5kg of bitumen for 10 Sqm
5417.5
-
41.55
Providing and laying semi-dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder CRMB-55 @ 5.0 per cent of mix and filler transporting the hot mix to work site, laying with hydrostatic paver finisher with sensor control to the required grade, level, and alignment rolling with smooth, wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause 508 complete in all respects. (MORTH/508) (A.R./GNIDA)
-
-
-
25mm compacted thickness with bitumen penetration of CRMB-55 @ 5% by weight of total mix.
5417.5
-
237.45
Part-B (Drain work)
-
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level: (Cast-in-Situ)
-
-
-
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). (DSR-13/4.1.8/P-85)
134.28
-
3920.65
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level: (Cast-in-Situ)
-
-
-
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). (DSR-13/5.1.2/P-96)
387.23
-
5552.25
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
Thermo-mechanically treated bars/Cold twisted bars. (DSR-13/5.22.6/P-99)
30397.55
-
66.5
Centring and shuttering including strutting, propping etc. and removal of form for:
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete. (DSR-13/5.9.1/P-97)
486.85
-
186.4
Centring and shuttering including strutting, propping etc. and removal of form for:
-
-
-
Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (DSR-13/5.9.2/P-97)
2536.96
-
334.5
Centring and shuttering including strutting, propping etc. and removal of form for:
-
-
-
Suspended floors, roofs, landings, balconies and access platform. (DSR-13/5.9.3/P-97)
20
-
371.8
Part-C (Sewerage System)
-
-
-
Earth work in excavation in ordinary soil in all type of foundation trenches including dressing of the side and ramming of bottom. Lifts upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m. All kinds of soil. (MORTH/A.R./GNIDA)
-
-
-
Depth from 0.0 to 1.5 M below G.L.
520.51
-
109.26
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m. (AR/GNIDA)
494.48
-
54.03
Supply of ISI marked RCC S&S NP-2 pipes of following size including carting, loading, unloading at godown including all taxes and levies & rubber rings. (AR/GNIDA)
-
-
-
250 mm dia NP-2 pipe
1039.94
-
303.42
Laying of NP-2 RCC S&S pipes jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 coarse sand) including testing of joints etc. complete. (AR/GNIDA)
-
-
-
250 mm dia NP-2 pipe
1039.94
-
83.23
Supply of ISI marked RCC S&S NP-3 pipes of following size including carting, loading, unloading at godown including all taxes and levies & rubber rings. (AR/GNIDA)
-
-
-
250 mm dia NP-3 pipe
50.59
-
347.48
Laying of NP-3 RCC S&S pipes jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 coarse sand) including testing of joints etc. complete. (AR/GNIDA)
-
-
-
250 mm dia NP-3 pipe
50.59
-
93
Supply of ISI marked RCC S&S NP-2 pipes of following size including carting, loading, unloading at godown including all taxes and levies & rubber rings. (AR/GNIDA)
-
-
-
150 mm dia NP-2 pipe
336
-
217.7
Laying of NP-2 RCC S&S pipes jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 coarse sand) including testing of joints etc. complete. (AR/GNIDA)
-
-
-
150 mm dia NP-2 pipe
336
-
60
Providing and laying in position cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) in concrete cradle under NP-2 pipe of following diameter including centring shuttering but excluding excavation. (AR/GNIDA)
-
-
-
250mm dia NP-2 concrete cradle
1006.42
-
266.5
Providing and laying in position cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) in concrete cradle under NP-3 pipe of following diameter including centring shuttering but excluding excavation. (AR/GNIDA)
-
-
-
250mm dia NP-3 concrete cradle
50.13
-
270.82
Providing and laying in position cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) in concrete cradle under NP-2 pipe of following diameter including centring shuttering but excluding excavation. (AR/GNIDA)
-
-
-
150mm dia NP-2 concrete cradle
297.36
-
217
Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design:
-
-
-
0.91m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal dia meter conforming to IS 12592, total weight of cover and frame not less than 182 Kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centring, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):
-
-
-
With bricks of class designation-150 (DSR-13/19.9.1.1/P-352)
62
-
8241.55
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91m to 1.67m: With bricks of class designation-150 (DSR-13/19.10.1/P-352)
14.23
-
4698.4
Constructing brick masonry circular type manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:
-
-
-
1.68m deep with SFRC cover and frame (heavy duty, HD-20 grade designation) 560mm internal dia meter conforming to IS 12592, total weight of cover and frame not less than 182 Kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centring, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):
-
-
-
With bricks of class designation-150 (DSR-13/19.11.1.1/P-352-353)
9
-
15524.4
Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29m: With bricks of class designation-150 (DSR-13/19.12.1/P-353)
6.77
-
6087.1
Constructing brick masonry circular type manhole 1.52m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:
-
-
-
2.30m deep with SFRC cover and frame (heavy duty, HD-20 grade designation) 560mm internal dia meter conforming to IS 12592, total weight of cover and frame not less than 182 Kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centring, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):
-
-
-
With bricks of class designation-150 (DSR-13/19.13.1.1/P-353)
1
-
33216.9
Extra depth for circular type manhole 1.52m internal dia (at bottom) beyond 2.30m: With bricks of class designation-150 (DSR-13/19.14.1/P-353)
0.06
-
14522.9
Constructing masonry chamber 60x60x75 cm. inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
-
-
-
With bricks of class designation-150 (DSR-13/18.36.1/P-325)
84
-
6140.5
Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:
-
-
-
150mm dia (DSR-13/19.34.2/P-357)
84
-
383.25
Brick work with bricks of class designation 150 in foundation and plinth in:
-
-
-
Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-13/6.1.2/P-111)
2
-
4646.5
12mm cement plaster of mix: 1:6 (1 cement : 6 coarse sand) (DSR-13/13.4.2/P-222)
50
-
142.25
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing, in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.) (DSR-13/19.16/P-353-354)
302
-
295.2
Add labour cess @ 1% on all above items
14534088.72
-
0.01
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements