Greater Noida Industrial Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Greater Noida Industrial Development Authority - GNIDA Tender

Works
Civil And Construction
Civil Works Others
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date16 Jul 2024
Closing Date29 Jul 2024
Tender Amount₹ 11,44,38,037 
Notes
Download

Costs

Summary

Electrical, Mechanical, Instrumental And Related Civil Work Of Zonal Reservoir (03 Nos.) And

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
CARRIAGE OF MATERIALS (DSR-1.0/2013)

-

-

-

... More
By Mechanical Transport including loading, unloading and stacking (DSR-1.1/2013)

-

-

-

... More
Earth (10km) (DSR-1.1.2/2013)

58.39

6456

110.58

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areaa (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m diposed earth to be levelled and neatly dressed. (DSR-2.6/2013)

-

-

-

... More
All kinds of soil (DSR-2.6.1/2013)

115.68

6907

59.71

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m. (DSR-2.25/2013)

57.29

2623

45.79

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR-2.27/2013)

331.08

236708

714.96

... More
Clearing grass and removal of the rbbish upto a distance of 50m outside the periphery of the area cleared. (DSR-2.32/2013)

270.4

681

2.52

... More
SUB HEAD-II :- CONCRETE WORKS

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR-4.1/2013)

-

-

-

... More
1:4:8 (1 Cement :4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm (DSR-4.1.8/2013)

10.87

36116

3322.58

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (DSR-4.17/2013)

78.28

25138

321.14

... More
SUB HEAD-III :- REINFORCED CEMENT CONCRETE WORK

-

-

-

... More
Centering and shuttering including including strutting, propping etc. and removal of form for all heights including forming grooves as and whereever requried as per drawing. (DSR-5.9/2013)

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete. (DSR-5.9.1/2013)

100.98

15951

157.97

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR-5.9.2/2013)

-

-

-

... More
Suspended floors, roofs, landings, balconies and access platform (DSR-5.9.3/2013)

365.6

115193

315.08

... More
Shelves (Cast in situ) (DSR-5.9.4/2013)

36.56

11519

315.08

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR-5.9.5/2013)

361.47

94900

262.54

... More
Columns, Pillars, Piers, Abutments, Posts and Struts (DSR-5.9.6/2013)

120.12

43059

358.47

... More
Stairs, (excluding landings) except spiral-staircases (DSR-5.9.7/2013)

16.56

5271

318.35

... More
Edges of slabs and breaks in floors and walls. (DSR-5.9.16/2013)

-

-

-

... More
Under 20cms wide (DSR-5.9.16.1/2013)

53.53

5067

94.66

... More
Cornices and mouldings (DSR-5.9.17/2013)

-

-

-

... More
Weather shade, chajjas, corbels etc. including edges. (DSR-5.9.19/2013)

40.15

15930

396.78

... More
STEEL REINFORCEMENT

-

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR-5.22/2013)

-

-

-

... More
Thermo-Mechanically Treated bars (DSR-5.22.6/2013) (Sail Steel)

2062.13

116221

56.36

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR-5.22A/2013)

-

-

-

... More
Thermo-Mechanically Treated bars (DSR-5.22A.6/2013) (Sail Steel)

26333.6

1484161

56.36

... More
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. (DSR-5.30/2013)

53.53

1263

23.6

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. "(Note :-Cement content considered in this item is @ 330 kg/cum."Excess/less cement used as per design mix is payable/recoverable separately). (DSR-5.33/2013)

-

-

-

... More
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).

-

-

-

... More
All works upto plinth level (DSR-5.33.1/2013)

13.75

66471

4834.28

... More
All works above plinth level upto floor V level (DSR-5.33.2/2013)

175.56

945197

5383.9

... More
Extra for providing richer mixes at all floor levels. (DSR-5.34/2013)

-

-

-

... More
Note :- Excess/less cement over the specified cement content used is payable/recoverable separately.

-

-

-

... More
Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:-Cement content considered inM-30 is @ 340 kg/cum) (DSR-5.34.1/2013)

174.54

9487

54.36

... More
Providing M-40 grade concrete instead of M-25 grade BMC/RMC. (Note :- Cement content considered in M-40 is @ 360 kg/cum) (DSR-5.34.3/2013)

90.26

14725

163.14

... More
SUB HEAD-IV :- BRICK WORK

-

-

-

... More
Brick work with non modular fly ash bricks conforming to IS:12894, class designation10 average compressive strength in super structure above plinth level up to floor V level in : (DSR-6.34/2013)

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.34.2/2013)

234.12

1016647

4342.42

... More
SUB HEAD-VII :- WOOD AND PVC WORK

-

-

-

... More
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, window and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR-9.12/2013)

18

88

4.92

... More
SUB HEAD-VIII :- STEEL WORK

-

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part-1 and M.S. top cover of required thickness for rolling shutters. (DSR-10.6/2013)

-

-

-

... More
80X1.25 mm M.S. laths with 1.25 mm thick top cover (DSR-10.6.1/2013)

48.6

84191

1732.33

... More
Providing and fixing ball bearing for rolling shutters. (DSR-10.7/2013)

12

4440

370.04

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. (DSR-10.8/2013)

-

-

-

... More
Exceeding 10.00 sqm and upto 16.80 sqm in the area. (DSR-10.8.1/2013)

48.6

27409

563.98

... More
Extra for provding grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in-charge (area of grill to be measured). (DSR-10.9/2013)

24.3

6457

265.76

... More
SUB HEAD IX :- FLOORING

-

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR-11.3/2013)

-

-

-

... More
40mm thick with 20mm nominal size stone aggregate. (DSR-11.3.1/2013)

177.5

47653

268.47

... More
Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement :3 coarses sand) finished with a floating coat of neat cement (DSR-11.6/2013)

-

-

-

... More
18 mm thick (DSR-11.6.1/2013)

106

26877

253.56

... More
Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) (DSR-11.26/2013)

-

-

-

... More
25mm thick (DSR-11.26.1/2013)

36.12

32804

908.22

... More
Kota stone slabs 20mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polising complete. (DSR-11.27/2013)

3.61

3367

932.92

... More
Extra for pre finished nosing in treads of steps of Kota stone/sand stone slabs. (DSR-11.31/2013)

37.2

2157

58.01

... More
Extra for kota stone/sand stone in treads of steps and risers using single length up to 1.05 metre. (DSR-11.32/2013)

5.04

65

12.97

... More
Providing and laying vitrified floor tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.41/2013)

-

-

-

... More
Size of Tile 600X 600 mm (DSR-11.41.2/2013)

47.5

56458

1188.6

... More
Providing and laying vitrified tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.46/2013)

-

-

-

... More
Size of Tile 600X 600 mm (DSR-11.46.2/2013)

36.6

43778

1196.14

... More
SUB HEAD- X ROOFING

-

-

-

... More
Providing gola 75X75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (DSR-12.21/2013)

-

-

-

... More
In 75X75 mm deep chase (DSR-12.21.1/2013)

56.69

6146

108.43

... More
Providing and laying roof insulation with 40mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulaton conforming to IS- 12432 Pt. III (density of foam being 40-50 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providng a wearing coursed of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) in chequered rough finish, in panels of 2.5m X 2.5m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. (DSR-12.56/2013)

253.47

245576

968.86

... More
ROOFING SUB HEAD TOTAL

-

-

-

... More
SUB HEAD-XI :- FINISHING WORK

-

-

-

... More
12mm cement plaster of mix : (DSR-13.1/2013)

-

-

-

... More
1:6 (1 cement : 6 fine sand) (DSR-13.1.2/2013)

392.08

44473

113.43

... More
6 mm cement plaster of mix : (DSR-13.16/2013)

-

-

-

... More
1:3 (1 cement : 3 fine sand) (DSR-13.16.1/2013)

365.6

37287

101.99

... More
18 mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) (DSR-13.11/2013)

392.08

71570

182.54

... More
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: (DSR-13.24/2013)

-

-

-

... More
Is one coats (DSR-13.24.1/2013)

117.62

24620

209.32

... More
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR-13.80/2013)

392.08

28374

72.37

... More
Colour washing such as green, blue or buff to give an even shade (DSR-13.39/2013)

-

-

-

... More
New work (two or more coats) with a base coat of white washing with lime (DSR-13.39.1/2013)

392.08

6563

16.74

... More
Finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete. (DSR-13.52/2013)

-

-

-

... More
on steel work (DSR-13.52.1/2013)

40.5

3768

93.05

... More
On concrete work (DSR-13.52.2/2013)

4.05

392

96.86

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour. (DSR-13.81/2013)

-

-

-

... More
Two coats (DSR-13.81.2/2013)

757.68

26806

35.38

... More
SUB HEAD-XII:- SANITARY INSTALLATIONS

-

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vetreous china flushing cistrn & C.P. flush bend with fittings & C.I. brackets, 40mm fluh bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved muninipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: (DSR-17.3/2013)

-

-

-

... More
W.C. pan with ISI marked white solid plastic seat and lid (DSR-17.3.1/2013)

1

3929

3929.03

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430X260X350mm and 340X410X265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting an making good the walls and floors wherever required. (DSR-17.4/2013)

-

-

-

... More
One urinal basin with 5 litre white PVC automatic flushing cistern (DSR-17.4.1/2013)

2

5380

2690.34

... More
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. (DSR-17.7/2013)

-

-

-

... More
White Vitreous China Wash basin size 630X450mm with a pair of 15mm C.P. brass pillar taps (DSR-17.7.1/2013)

1

1842

1842.92

... More
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the receptin of pipes and fittings (DSR-17.8/2013)

1

824

824.11

... More
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete (DSR-17.28/2013)

-

-

-

... More
Flexible pipe (DSR-17.28.2/2013)

-

-

-

... More
32mm dia (DSR-17.28.2.1/2013)

1

61

61.48

... More
Providing and fixing 600X450 mm beveled edge mirror of superrior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete (DSR-17.31/2013)

1

645

645.97

... More
SUB HEAD-XII:- WATER SUPPLY

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (DSR-18.8/2013)

-

-

-

... More
Concealed work, including cutting chases and making good the wall etc.

-

-

-

... More
20 mm nominal outer dia Pipes (DSR-18.8.2/2013)

30

7152

238.43

... More
25 mm nominal outer dia Pipes (DSR-18.8.3/2013)

30

8548

284.96

... More
32 mm nominal outer dia Pipes (DSR-18.8.4/2013)

30

10357

345.25

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of E/I. (DSR-18.9/2013)

-

-

-

... More
100 mm nominal inner dia Pipes (DSR-18.9.9/2013)

30

71782

2392.75

... More
150 mm nominal inner dia Pipes (DSR-18.9.10/2013)

30

86664

2888.81

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931 (DSR-18.49/2013)

-

-

-

... More
15mm nominal bore (DSR-18.49.1/2013)

2

776

388.47

... More
Providing and fixing C.P. brass stop cock (conceale) of standard design and of approved make conforming to IS:8931 (DSR-18.52/2013)

-

-

-

... More
15mm nominal bore (DSR-18.52.1/2013)

2

1048

524.32

... More
SUB HEAD - XIV - DRAINAGE

-

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45X45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mm diameter, 1.8m long complete as per standard design (DSR-19.32/2013)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.32.1/2013)

1

14157

14157.16

... More
Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. (DSR-19.7/2013)

-

-

-

... More
Inside size 90X80 cm and 45 cm deep including C.I. cover with frame (light duty) 455X610mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg.) (DSR-19.7.1/2013)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.7.1.1/2013)

2

13665

6832.8

... More
Extra for depth for manholes: (DSR-19.8/2013)

-

-

-

... More
Size 90X80 cm (DSR-19.8.1/2013)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.8.1.1/2013)

0.15

696

4645.25

... More
SUB HEAD -XV : - ALUMINIUM WORK

-

-

-

... More
Providing and fixing aluminium work for door, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and joined mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/stainless steel screw, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and paneling to be paid for separately) (DSR-21.1/2013)

-

-

-

... More
For fixed portion (DSR-21.1.1/2013)

-

-

-

... More
Powder coated Aluminum (minimum thickness of powder coating 50 micron) (DSR-21.1.1.2/2013)

268.8

84967

316.1

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required (fittings shall be paid for separately) (DSR-21.1.2/2013)

-

-

-

... More
Powder coated Aluminum (minimum thickness of powder coating 50 micron)(DSR-21.1.2.2/2013)

149.76

54268

362.37

... More
Providing and fixing glazing in luminium door, windows, ventilator, shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings an the directions of the E/I (Cost of aluminium snap beading shall be paid in basic item) (DSR-21.3/2013)

-

-

-

... More
With float glass panes of 4.0mm thickness (DSR-21.3.1/2013)

89.86

60160

669.49

... More
With float glass panes of 5.50mm thickness (DSR-21.3.2/2013)

59.9

51219

855.08

... More
Filling the gap in between aluminuim frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of E/I complete (DSR-21.8/2013)

-

-

-

... More
Upto 5mm depth and 5mm width (DSR-21.8.1/2013)

66

4645

70.38

... More
SUB HEAD -XVI-WATER PROOFING WORK

-

-

-

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water profing compound conforming to IS. 2645 and approved by E/I over the RCC slab inclding adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admided with watr proofing compound conforming to IS 2645 and approved by E/I over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand)

-

-

-

... More
admixed with water proofing compound conforming to IS : 2645 and approved by E/I to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) after two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by E/I finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by E/I including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300X300 mm square 3mm deep) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curring and for final test. All above operations to be done in order and as directed and specified by the E/I. (DSR-22.7/2013)

-

-

-

... More
With average thickness of 120mm and minimum thickness at Khurra as 65mm (DSR-22.7.1/2013)

253.47

189587

747.97

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by E/I and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement 3 coarse sand) mixed with water proofing compound confirming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately) Joints saled and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (DSR-22.1/2013)

-

-

-

... More
Using rough kota stone (DSR-22.1.1/2013)

6

4292

715.34

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gap with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement 3 coarse sand) 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all level and as direction by E/I. (DSR-22.2/2013)

-

-

-

... More
Using rough kota stone (DSR-22.2.1/2013)

30

26361

878.73

... More
SUBMERSIBLE PUMP WITH MOTOR

-

-

-

... More
Supply, Erection, testing and commissioning of Submersible pump with CI casing, CF8 M impeller , SS 410 shaft, CI casing wearing ring & bearing bush, TC/ SIC mechanical seal, SS strainer etc suitable for 3 phase, 415 V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class H/F insulation as per specs and IP 68 protection. The pump shall be operated at suitable rpm as per data sheet. The scope includes all required accessories viz. automatic coupling device,G.I guide pipe, chain with shakle, flat/ round submersible cable upto starter panel through suitable size G.I. pipe with necessary electrical connection with the starter panel and as per specifications

-

-

-

... More
Capacity : 550 M³/hr Head : 42 mtrs. Motor Rating : 110 KW

2

3192205

1596102.54

... More
VALVES

-

-

-

... More
MOTOR OPERATED SLUICE VALVE

-

-

-

... More
Supply, installation, testing and commissioning of motor operated double flanged, C.I. Sluice Valve

-

-

-

... More
Size : 400 mm NB for Pump Discharge Line

2

606854

303427.12

... More
Size : 500 mm NB for Header

1

381527

381527.97

... More
Size : 500 mm NB for OHT

1

381527

381527.97

... More
CHECK VALVE

-

-

-

... More
Cast iron double flanged Single Door Swing Check Valve

-

-

-

... More
Size : 400 mm NB for Pump Discharge Line

2

359084

179542.37

... More
KINETIC AIR VALVE

-

-

-

... More
Supply, Installation, testing & commissioning of C.I. double acting kinetic Air Valve with isolation sluice valve.

-

-

-

... More
Size : 100 mm NB

1

38153

38153.39

... More
MANIFOLD PIPE & PIPE SPECIALS

-

-

-

... More
Supply, Fabrication, laying, testing and commissioning of M.S. pipe & specials with necessary supports & anchoring and including nuts, bolts and hardware

-

-

-

... More
Size : 400 mm NB for Pump Discharge Line

10

45855

4585.59

... More
Size : 500 mm NB for Header

25

153135

6125.42

... More
Supply, Fabrication, Fitting, testing and commissioning of Metallic Expansion Joint with necessary supports & anchoring and including nuts, bolts and hardware

-

-

-

... More
Size : 400 mm NB for Pump Discharge Line

2

94261

47130.51

... More
Supply, Fabrication, laying, testing and commissioning of pipe fittings and specials including Nuts, bolts and hardware

417

31804

76.27

... More
DEWATERING PUMP

-

-

-

... More
Supply, installation, testing & commissioning of non clog submersible dewatering pump to remove sand, silt, clay, sand, pebbles, small rock, algae, shells, plankton, etc. ( with specific gravity of up to 1.1 ) having CI casing, CF8 M impeller , SS 410 shaft, CI casing wearing ring & bearing bush,suitable for 3 phase, 415 V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class H/F insulation as per specs and IP 68 protection. The pump shall be operated at suitable rpm as per data sheet with all required accessories.

-

-

-

... More
Capacity : 50 mtr3/hr.

-

-

-

... More
Head : 10 mtrs.

-

-

-

... More
Motor Rating : 3.7 KW

1

202104

202104.24

... More
E.O.T. CRANE WITH HOIST

-

-

-

... More
Supply, erection, testing and commissioning of fully electrically operated hoist, geared trolley, gantry girder, brake, safety device, locking arrangement, limit switch, pendant push button, starter panel, cables,and other required accessories.

-

-

-

... More
Capacity : 5.0 Ton. For Pump room

-

-

-

... More
Span : 10 mtrs.

-

-

-

... More
Lift :10.00 mtrs. (min)

1

845228

845228.14

... More
Supply, erection, testing and commissioning of fully electrically operated hoist, geared trolley, gantry girder, brake, safety device, locking arrangement, limit switch, pendant push button, starter panel, cables,and other required accessories.

-

-

-

... More
Capacity : 2.0 Ton.

-

-

-

... More
Lift :5.00 mtrs. (min)

1

441855

441855.93

... More
CHLORINATION PLANT

-

-

-

... More
Supply, installation, testing & commissioning of vacuum control floor mounted gas chlorinator system including necessary fittings, clamp, copper pipe, ferule filter & control valve with injector with required booster pump, set of diffuser entire associated water & chlorine soulution piping upto diffuser etc, valves,automatic change over ,Chlorine absorption system, saftey & testing kit, etc. complete in all respect as per specs & as per following capacity

-

-

-

... More
Capacity : 2 x 3 kg/hr

1

3075711

3075711.86

... More
Supply, erection, testing and commissioning of single girder electrically operated hoist, geared trolley, brake, safety device, locking arrangement, limit switch, pendant push button, starter panel, cables,and other required accessories.

-

-

-

... More
Capacity : 3.0 Ton.for Chlorination plant

1

538627

538627.12

... More
Span : 5.0 mtrs.(max)

-

-

-

... More
Lift :10.00 mtrs. (min)

-

-

-

... More
900 kg. Chlorine Tonners duly approved by dept. of explosive

2

237288

118644.07

... More
ELECTRICAL WORK

-

-

-

... More
H.T. INDOOR SWITCH GEAR PANEL

-

-

-

... More
Supply, Installation, Testing and Commissioning (SITC) of 11 kV, 350 MVA, 400 A, indoor, drawout type Three HT Vaccuum Circuit Breaker Panel (single breaker) with CT and PT of appropriate rating for metering and protection along with required Indicating lamps, protection relay and Indicating meters, etc. complete in all respects as per IS, Specification.

1

358785

358785.59

... More
H.V. CABLES

-

-

-

... More
Supply, delivery, laying testing & commissioning of 11KV (E), XLPE cable having compacted circular staranded aluminium conductor, conductor screening of extruded semi conducting compound, cross linked polythylane (XLPE), insulation screening of the extruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments) for following mentioned sizes. It should be operational at 11 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on sides and

-

-

-

... More
top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I. Complete in all respect. The price are inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respects and as per requirement of the job.

-

-

-

... More
(CCI (Bombay/Nashik), Fort Gloster (Calcutta / Baripara), Asian (Thane / Silvasha), Universal (Satna), Nicco (Calcutta), ICL (Rajpura), Diamond, Havells make SOR-3

-

-

-

... More
3CX240 Sqmm.

60

98085

1634.75

... More
Supply, Delivery, Installation, Testing & Commissioning of 11KV, indoor type cable termination kit of 3 core cable for cable termination at the panel & transformer complete in all respects as required for proper completion of work. (450mm length) SOR-5 (make Raychem/C.C.I./Frontec) d) 3CX240 Sq.mm.

4

36640

9160.17

... More
DISTRIBUTION TRANSFORMER

-

-

-

... More
Supply, delivery, assembly, installation, testing and commissioning of indoor type distribution transformer. 11/0.433 KV, 3 Phase, Double wound winding. Voltage ratio 11000/433- 250 Volts, vector group Dyn 11. Air cooled with manually operated +5% and +10% off load Tap changer and complete with standard fitting & accessories as given in the specification and also confirming to ISS : 2026 with firsh filling of the oil complete as required. (This includes oil testing for dielectric strength, flask over test and filtration of transformer oil to be conducted in the event of unsatisfactory results of oil testing. (Crompton, NGEF, Alstom, BHEL, Voltamp, Diamond, Reychem, Kanohar make) SOR-13 Copper wound (e) 315 KVA

1

463303

463303.39

... More
Supply and levelling of transformer yard using gravel, fine sand and other required filing material, enmarked for the switchyard including removing of trees or boulders if any etc. The general level of the yard shall be at a convenient level for movement of man and material and it should match with FGL.

40

10576

264.41

... More
Supply and Installation of Chain link fencing around switch yard etc. as per Specification.

25

21589

863.56

... More
SITC of 2.5 mtr wide gate with required material as per Specification.

1

8633

8633.9

... More
SITC of Medium Voltage Panel Board

-

-

-

... More
MEDIUM VOLTAGE PANEL BOARD

-

-

-

... More
Panel Board Encloser & Bus-Bar

-

-

-

... More
Supplying, Installation, Testing and Commissioning of Indoor floor mounted totally enclosed, compartmentalized, extendable type PCC / PMCC / MCC Cubicle Panel Board having 36 MVA, 50A breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum 0.8 A/mm2 current density,

-

-

-

... More
extensible type, DMC/SMC busbar supports, suitable for 3 phase-neutral 415 V, 50 HZ AC supply i/c providing and fixing the following switchgears mounted thereon complete with gaskets and interconnections, connections as per specifications complete as required. (The board shall be dust & vermin proof with degree of protection of IP 52 as per IS:12063, free standing type, mounted on base channel of MS Section not less than 100 mm X 50 mm X 5 mm), Isolated cubical compartment for fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.5.5M length X 1M Min.Width X Maximum 2.3M Height with base channel)

-

-

-

... More
500 rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (All bus bars shall be considering Maximum Current Density 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (8 Mtr.)

-

-

-

... More
Incoming Section

-

-

-

... More
Incomer Breaker for Transformer (Qty.1 Nos.)

-

-

-

... More
4 Pole MCCB - 500A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
3-Phase Digital Type Multifunction Meter (96x96Sqmm.), Accuracy. Class-0.5S (for Active) suitable to measure kVA, kW, kWH, kVAr, kVArH, A,V, P.F. & Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos.)

-

-

-

... More
500/5A, CL 0.5, 15VA for Metering CTs - (3 Nos.)

-

-

-

... More
500/5A, CL.0.5 15VA, CTs for APFC relay - (3 Nos.)

-

-

-

... More
On / Off / Trip / Spring charge LED type Indication Lamp, 220VAC 22.5mm. - (4 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
R,Y,B Led Indication Lamp, 220VAC 22.5mm, - (3 Nos.)

-

-

-

... More
Digital Voltmeter ( 0-500 V) with control fuses. - (1 Nos.)

-

-

-

... More
Digital Ammeter ( 0-500 A) with control fuses. - (1 Nos.)

-

-

-

... More
Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.)

-

-

-

... More
DG Incomer Breaker D.G (Qty.1 No.)

-

-

-

... More
4 Pole MCCB - 400A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
400/5A, CL 0.5, 15VA, Metering CTs - (3 Nos.)

-

-

-

... More
On / Off / Trip / Spring charge LED type Indication Lamp, 220VAC 22.5mm. - (4 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (3 Nos.)

-

-

-

... More
R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.)

-

-

-

... More
Digital Voltmeter ( 0-500V) with control fuses. - (1 Nos.)

-

-

-

... More
Digital Ammeter ( 0-400A) with control fuses. - (1 Nos.)

-

-

-

... More
Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.)

-

-

-

... More
Transformer No-load losses comp. Fixed Capacitors for Tran. (Qty.1 Nos.)

-

-

-

... More
32A 3P MCB, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
16 kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Timer for Capacitor - (1 Nos.)

-

-

-

... More
R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.)

-

-

-

... More
On LED type Indication Lamp, 220VAC 22.5mm. - (1 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
20A MCB for Capacitor - (1 Nos.)

-

-

-

... More
8A MCB for Capacitor - (1 Nos.)

-

-

-

... More
6A MCB for Capacitor - (1 Nos.)

-

-

-

... More
9 kVAR APP. Type Capacitor - (1 Nos.)

-

-

-

... More
4 kVAR APP. Type Capacitor - (1 Nos.)

-

-

-

... More
3 kVAR APP. Type Capacitor - (1 Nos.)

-

-

-

... More
Outgoing Section

-

-

-

... More
210A Soft-Starter for 132kW (Suitable for 110kW Moto after derating) Feeder Each Comprising of following: (Qty. 2 Sets.)

-

-

-

... More
350A TP MCCB, 36 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
325A Three Pole AC-3 duty line Contactor - (1 Nos.)

-

-

-

... More
630A Semiconductor (FA) Bussmann fuse type 170M5012 & Fuse Holder-170H3004 - (3 Nos.)

-

-

-

... More
210A Soft-Starter for 132kW (Suitable for 110kW Moto after derating) - (1 Nos.)

-

-

-

... More
325A Three Pole AC-3 duty By Pass Contactor of Soft Starter - (1 Nos.)

-

-

-

... More
350/5A, CL 0.5, Metering CTs - (3 Nos.)

-

-

-

... More
On / Off / Trip LED type Indication Lamp, 220VAC 22.5mm. - (3 Nos.)

-

-

-

... More
Stat Push Button - (1 Nos.)

-

-

-

... More
Stop Push Button - (1 Nos.)

-

-

-

... More
Digital Ammeter ( 0-350A) with control fuses. - (1 Nos.)

-

-

-

... More
Selectro Switch (Ammeter) - (1 Nos.)

-

-

-

... More
Selectro Switch (Auto/Manual, Local/remote) - (2 Nos.)

-

-

-

... More
Pump Protection Unit - (1 Nos.)

-

-

-

... More
(MPR + SPP) with CBCT - (1 Nos.)

-

-

-

... More
2.5A TP MPCB with Thermostate and 2 nos. Cooling fan (CFM- 105) for Starter Enclosure etc. - (1 Lot)

-

-

-

... More
APFC Panel feeder (For 55 kVAR APFC Panel) - (Qty. 1 No.)

-

-

-

... More
100 A TPN MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.)

-

-

-

... More
On / Off LED type Indication Lamp, 220VAC 22.5mm. - (2 Nos.)

-

-

-

... More
63 A (415V) TPN 'C' Curve MCB Feeders - (2 Nos.)

-

-

-

... More
32 A (415V) TPN 'C' Curve MCB Feeders - (10 Nos.)

-

-

-

... More
Power Feeders

-

-

-

... More
32 TPN MCB Feeders for Incomer - (1 Nos.)

-

-

-

... More
On / Off LED type Indication Lamp, 220VAC 22.5mm for (a) Incommer - (2 Nos.)

-

-

-

... More
6A TPN 'C' Curve MCB - (6 Nos.)

-

-

-

... More
Miscellaneous accessories

-

-

-

... More
Terminals, Jumper wires, Control wiring, HRC fuse link with Control Fuse, Space heater, Control Transformer, Illumination lamp and all other required Panel Miscellaneous accessories etc.. - (1 Lot)

-

-

-

... More
i) Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables. ii) Provide terminals for Trip interlock for future use. ( Spare shall be supplied with short link) - (1 Lot)

-

-

-

... More
Note: i) Auto/Manual and Local / Remote selector switches shall be provided for all starters which shall operate through PLC when selected in Auto Mode. In manual mode the drive shall operate through manually through MCC-PB or through LCS-PB. When Local / Remote switch is selected in local mode or remote mode respectively. Potential free contacts shall be provided to monitor drive status signals (A/M switch status, drive On/Off status and drive trip status) at PLC. ii) Low level switch for dry run protection pumps shall be interlocked at respective starters through provision of required relays and relay based logic for pumps tripping at ICP.

1

1817657

1817657.63

... More
APFC PANEL BOARD (55 kVAR - 8 STEP)

-

-

-

... More
Panel Board Encloser & Bus-Bar

-

-

-

... More
Supplying, Installation, Testing and Commissioning of Indoor floor mounted totally enclosed, compartmentalized type APFC Cubicle Panel Board having 36 MVA breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum 0.8 A/mm2 current density, extensible type, DMC/SMC

-

-

-

... More
busbar supports, suitable for 3 phase- neutral 415 V, 50 HZ AC supply I/c providing and fixing the following switchgears & capacitors mounted there on complete with gaskets and interconnections, connections as per specifications complete as required. (The APFC Panel board shall be dust & vermin proof with degree of protection of IP 42 as per IS:12063, free standing type, mounted on base channel of MS Section not less than 100 mm X 50 mm X 5 mm) and as per IS, Specification (Mini.1.2M length X Min. 750M Width X Maximum 2M Height with base channel) - (Area Sqm.)

-

-

-

... More
100A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (All bus bars shall be considering Maximum Current Density 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (2 Mtr.)

-

-

-

... More
Incoming Section

-

-

-

... More
Incomer Breaker for APFC (Qty. 1 No.)

-

-

-

... More
100 A 3P+N MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. For On / Off /Trip - (3 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm For R, Y, B - (3 Nos.)

-

-

-

... More
HRC Control fuses with fuse base (6A) for voltmeter, Ameter,APFC relay - (9 Nos.)

-

-

-

... More
Digital Voltmeter (0-500V) - (1 Nos.)

-

-

-

... More
100/5A, CL-1, 15VA, Metering CTs - (3 Nos.)

-

-

-

... More
Digital Ammeter (0-100A) - (1 Nos.)

-

-

-

... More
Selectro Switch (For Auto / Manual) - (1 Nos.)

-

-

-

... More
APFC Relay

-

-

-

... More
8-Step Microprocessor Based APFC Relay - (1 Nos.)

-

-

-

... More
Outgoing Section

-

-

-

... More
15kVAR Capacitors feeders, Qty. 1 No.

-

-

-

... More
32A 3P MCB for Capacitor - (1 Nos.)

-

-

-

... More
15kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.)

-

-

-

... More
15kVAR Double layer APP Type Capacitor - (1 Nos.)

-

-

-

... More
10kVAR Capacitors feeders each Comprising of following: (Qty. 2 Set.)

-

-

-

... More
32A 3P MCB for Capacitor - (1 Nos.)

-

-

-

... More
10kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.)

-

-

-

... More
10kVAR Double layer APP Type Capacitor - (1 Nos.)

-

-

-

... More
5kVAR Capacitors feeders each Comprising of following: (Qty. 4 Set.)

-

-

-

... More
16A 3P MCB for Capacitor - (1 Nos.)

-

-

-

... More
5kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.)

-

-

-

... More
5kVAR Double layer APP. Type Capacitor - (1 Nos.)

-

-

-

... More
Miscellaneous APFC Panel Accessories

-

-

-

... More
Terminals, Jumper wires, Control wiring, HRC fuse link with Control Fuse, Space heater, Control Transformer, Illumination lamp and all other required Panel Miscellaneous accessories etc.. - (1 Lot)

-

-

-

... More
Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables. - (1 Lot)

-

-

-

... More
Note: Auto/Manual selector switches shall be provided for Auto/Manual mode of opearation to operate APFC Panel through APFC Relay when selected in Auto Mode & in manualy when selected Manual mode. - (1 Lot)

1

215685

215685.59

... More
LDB / PDB / JB / LCS

-

-

-

... More
SITC of Lighting Distribution Board as under: Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Single door

1

3488

3488.98

... More
Incoming Section

-

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

1

1803

1803.39

... More
Outgoing Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

24

2969

123.73

... More
SITC of Outdoor Lighting Distribution Board as under: Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/recess complete with loose wire box of sheet steel, dust protected,duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way Double door

1

8969

8969.49

... More
Incoming Section

-

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

1

1563

1563.56

... More
32A Contactor

1

1588

1588.98

... More
Time switch.

1

1697

1697.46

... More
Outgoing Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral

8

5315

664.41

... More
SITC of Power Distribution Board as under: Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s,terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way Single door

1

10844

10844.92

... More
Incoming Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral

1

664

664.41

... More
Outgoing Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

12

6203

516.95

... More
SITC of stand / wall mounting Junction Box with Protection Class of IP-65, fault level-25kA with steel structure stand etc. for Termination of 1.1 kV Submersible Flexible Copper Power & Control cable with (A) One run 3C x 185 sq.mm A2XFY power cable.

2

10323

5161.86

... More
SITC of stand / wall mounting Junction Box with Protection Class of IP-65, fault level-25kA with steel structure stand etc. for Termination of 1.1 kV Submersible Flexible Copper Power and / or Control cable with (A) 5C x 2.5/1.5 sq.mm ywy control cable.

2

7810

3905.08

... More
SITC of Pendant type ON_OFF pushbutton set complete with Enclouser, necessary mounting/ fixing arrangement on wall / pipe support etc. to be installed near motors for remote operation, etc. as per IS and specifications

2

5206

2603.39

... More
MEDIUM VOLTAGE CABLES

-

-

-

... More
Supply & laying of aluminum conductor PVC insulated armoured served sheathed cables 1100 Volts grate at a depth of below ground level over a cushion of 75 mm. below ground level over a cushion of 75 mm. thick sand all round and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer – in charge, complete in all respected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.

-

-

-

... More
300sq. mm. 3-1/2 core

70

120008

1714.41

... More
185sq. mm. 3-1/2 core

210

237585

1131.36

... More
70sq. mm. 3-1/2 core

25

14067

562.71

... More
6 sq.mm. 4 core

200

41356

206.78

... More
4 sq.mm. 3 core

100

18220

182.2

... More
SITC of 1.1 kV, YWY / PVC insulated (IS 1554) Cu conductor cables as per specification & IS.

-

-

-

... More
3C x 2.5 sq. mm. YWY Cable

465

72112

155.08

... More
4C x 2.5 sq. mm. YWY Cable

550

103477

188.14

... More
5C x 1.5 sq.mm. YWY Cable

90

14415

160.17

... More
10C x 1.5 sq.mm. YWY Cable

70

19695

281.36

... More
CABLE END TERMINATION AND CONNECTION:

-

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required.

-

-

-

... More
3½ X 300 sq. mm (70mm)

4

3186

796.61

... More
3½ X 185 sq. mm (57mm)

12

6823

568.64

... More
3½ X 70 sq. mm (38mm)

2

549

274.58

... More
Supply & fixing of brass nickel plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects .The armoured of the cable shall be properly connected with the earth as per direction of Engineer – in charge.

-

-

-

... More
6sq.mm. 4 core

6

300

50

... More
4sq.mm. 3 core

2

79

39.83

... More
Supply & fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of Engineer – in charge.

-

-

-

... More
6sq.mm.

24

244

10.17

... More
4sq.mm.

6

61

10.17

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required.

-

-

-

... More
3C x 2.5 sq. mm. YWY Cable

12

2044

170.34

... More
4C x 2.5 sq. mm. YWY Cable

28

4769

170.34

... More
5C x 1.5 sq.mm. YWY Cable

4

586

146.61

... More
10C x 1.5 sq.mm. YWY Cable

4

996

249.15

... More
CABLE TRAY

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

50

48220

964.41

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

45

32071

712.71

... More
150 mm width X 50 mm depth X 1.6 mm thickness

50

22161

443.22

... More
EARTHING

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

12

90905

7575.42

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

10

31805

3180.51

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

105

135165

1287.29

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

50

4364

87.29

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

100

2881

28.81

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

100

11525

115.25

... More
50 x 6 GI strips

150

28221

188.14

... More
INTERNAL WIRING

-

-

-

... More
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

47

28956

616.1

... More
Supply and wiring of submain with four no. 2.5 sq.mm. FR PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2mm thick) PVC conduit with two no. 1.5 sq.mm. FR PVC insulated 1100 V grade multistrand copper conductor as earth continuity wire drawn inside the conduit.

250

37077

148.31

... More
Wiring for Circuit / Submain wiring along with earth wire with the (2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire) sizes of FRLS insulated copper conductor, Single core cable in Surface / recessed medium class PVC Conduit as required.

165

19575

118.64

... More
Supply and fixing of 25 mm sizes of medium Class PVC Conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

165

10068

61.02

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

2

1325

662.71

... More
Supply and fixing of following size / modules, GI Box along with modular base & cover plate for modular switches in recess etc. as required. (For 15/16A and 5A/6A Switch & Socket)

-

-

-

... More
(a) 8 Module (125mm x 125mm)

14

3215

229.66

... More
(b) 3 Module (100mm x 75mm)

12

1749

145.76

... More
Supply and fixing of following Modular Switch / Socket on the modular plate & Switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
6 pin 15/16 Amp Socket outlet

26

3591

138.14

... More
15/16 Amp Switch

26

2511

96.61

... More
3 pin 5/6 Amp Socket outlet

14

1198

85.59

... More
5/6 Amp Switch

14

913

65.25

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

674

674.58

... More
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (Pump house & Panel room)

3

5481

1827.12

... More
Supplying and fixing TP sheet steel enclosure on surface/recess along with 16/25/32amps 415 volts “C” curve TP MCB complete with connections, testing and commissioning etc. as required. (For Ele. Hoist etc.)

3

2161

720.34

... More
INTERNAL LIGHT FIXTURES

-

-

-

... More
Supply and fixing of factory wired HPF industrial type fluorescent tube light fitting with vitreous enameled reflector suitable for 2X40 w fluorescent tube including tubes etc. on surface complete in all respects. Cat AA (seg.)

21

29097

1385.59

... More
Supply and fixing of factory wired, surface type mirror optic fittings made of pre anodized aluminium section with P2 / P5 louvers suitable for & with 2no.36 w CFL complete in all respect. Cat AA

2

9911

4955.93

... More
Supply and fixing of factory wired asymmetrical beamed integral flood light luminaires with die cast aluminium housing & A1 .reflector having built in control gear unit duly pre wired plate complete with ballast, ignitor ,capacitor for 1*150 w M.H. with lamp complete in all respect. Cat AA

3

14761

4920.34

... More
Supply and fixing of industrial bulk head fitting with polycarbonate base guard, prismatic reflector silicon gasket suitable for and with 1X18 w CFL complete in all respect. Cat A

2

1203

601.69

... More
380mm sweep 1400 R.P.M exhaust fan, capacitor type, having double ball bearing, M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC supply conforming to IS: 2312.Fan shall be painted with epoxy grey colour controlled by one 6 A flush type switch on board and 6A plug point near Ex. fan.

6

12716

2119.49

... More
1200mm sweep ceiling fan, capacitor type, having double ball bearing 450mm down rod, canopies, shackle, rubber bush, blades, electronic speed regulator, suitable to operate on 230V,50Hz AC supply conforming to IS: 374/1979.Fan shall be painted with white colour.

3

3775

1258.47

... More
EXTERNAL LIGHT FIXTURES

-

-

-

... More
Supply and fixing of factory wired asymmetrical beamed integral flood light luminaires with die cast aluminium housing & A1 .reflector having built in control gear unit duly pre wired plate complete with ballast, ignitor ,capacitor for 1*150W M.H. with lamp complete in all respect. Cat AA

8

36881

4610.17

... More
Supply & erection of Steel tubular single wing pole with 30cm around & 1/6 over all length of pole grouted with cement concrete in 1:3:6 (1 cement : 3 coarse sand : 6 stone ballast) including plinthing of pole & 15cm around & 30 cm above the ground level, plastering of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. required for proper completion of work as per direction of E/I. SOR-20 a) 410 SP-17, 8.5mtr., 92kg.

6

44745

7457.63

... More
Supply and fixing of factory wired sodium vapour lamp street light luminaries single piece cast “Aluminium” body suitable for 70w S.V. lamp including integral control gear, 70w S.V. lamp on G.I. pipe bracket complete in all respects on on pole.

6

21203

3533.9

... More
Supply and fixing of H.P.M.V. post top lantern, suitable for 80w M.V. lamp complete with control gear pole mounting box and 80 w M.V. lamps etc. complete in all respects. Cat AA (seg.)

2

5108

2554.24

... More
DIESEL GENERATOR WITH AMF PANEL SET

-

-

-

... More
SITC OF DIESEL GENERATOR WITH ENGINE, ALTERNATOR & DG CONTROLLER SET

-

-

-

... More
SITC of 225 KVA DG set or higher rating (as required to run complete working load of pumping station including lighting.) 415 V,50 Hz,3 Phase, 4 wire Diesel Generator (Engine, Alternator & DG Controller) Set. Diesel engine shall be complete with necessary controls and safety devices confirming to relevent ISS/BSS with latest amendements. Diesel Engine shall be suitable for continuous operation of generator set duty inclusive of fly wheel, air cleaner, radiator.fan with guard,fuel pump,fuel filter,Electronic governor,electrical starting system with starter,12 V battery, voltage regulator,instrument panel, Exhaust silencer, protections against low lubrication oil pressure,high water temperature.

-

-

-

... More
Alternator shall be 415V, 3 phase, 50 Hz, 4 wire, 0.8 power factor, self excited,self regulated,brushless type,drip proof confirming to IS:4722 with latest amendments. DG set shall comply latest emission norms of Ministry of Environment & Forest (MOEF) by Government of India, effective from July 2014. DG set engine shall be manufactured as per present CPCB norms. DG set rating shall be for prime rating power (PRP) in accordance with BS 5514 / IS / ISO. DG set shall meet all statutory / pollution control regulation requirement with all currently applicable statutory norms, regulations and safety codes of the latest applicable Indian Standards.

-

-

-

... More
The engine and alternator shall be coupled over a sturdy common base frame. Day fuel tank with necessary fuel to hoses the engine fule and complete in all respect as required. DG set shall be along with acoustic enclosure / canopy and suitable for outdoor mounting.

-

-

-

... More
SITC OF AMF PANEL

-

-

-

... More
Panel Board Encloser & Bus-Bar

-

-

-

... More
Supplying, Installation, Testing and Commissioning of Indoor floor mounted totally enclosed, compartmentalized, extendable type AMF Panel Board having 36 MVA, 50 kA breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with electrolytic grade high conductivity PVC sleeved aluminium (E91

-

-

-

... More
E) busbars, DMC/SMC busbar supports, suitable for 3 phase- neutral 415V, 50 HZ AC supply i/c providing and fixing the following switchgears mounted thereon complete with gaskets and interconnections, connections as per specifications complete as required. (The board shall be dust & vermin proof with degree of protection of IP 52 as per IS:12063, free standing type, mounted on base channel of MS Section not less than 100 mm X

-

-

-

... More
50 mm X 5 mm), Isolated cubical compartment for fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.0.8M length X 0.75M Min.Width X Maximum 2.3M Height with base channel)

-

-

-

... More
630A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (All bus bars shall be considering Maximum Current Density 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (1.50 Mtr.)

-

-

-

... More
DG Incomer Breaker, (Qty. 1 Set)

-

-

-

... More
4Pole ACB - 630A, 50 kA, with Micro Processor based releases (Overload, Short Circuit and earth fault protetive release) etc. - (1 Set)

-

-

-

... More
3-Phase Digital Type Multifunction Meter (96x96Sqmm.), Accuracy Class-1, suitable to measure A,V, P.F. & Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos.)

-

-

-

... More
3-Phase Digital Type Trivector / Energy Meter, Accuracy Class- 0.5S (For Active), suitable to measure kVA, kW, kWH, kVAr, kVArH, P.F. & Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos.)

-

-

-

... More
630/5A, Core-1 CL 0.5, 15VA for Metering - (3 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
Digital Voltmeter (0-500V) with control fuses. - (1 Nos.)

-

-

-

... More
Digital Ammeter (0-630A) with control fuses. - (1 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm for On / Off / Trip/ Spring charge- (4 Nos.)

-

-

-

... More
LED Indication Lamp, 220VAC 22.5mm for R,Y,B - (3 Nos.)

-

-

-

... More
LED Indication Lamp, 220VAC 22.5mm for Load ON, Controln ON, Breaker ON & OFF - (4 Nos.)

-

-

-

... More
Push Button for Engine Start & Stop, Emergency Stop, ACB Trip & Closed, Hooter Accept - (6 Nos.)

-

-

-

... More
Selectro Switch for Ammeter, Voltmeter, Control Supply On&Off, Auto-Manual mode, Local-Rermote (PLC) mode. - (5 Nos.)

-

-

-

... More
Automatic Mains Failure (AMF) Digital Relay - (1 Nos.)

-

-

-

... More
Line Voltage Monitoring digital Relay - (1 Nos.)

-

-

-

... More
Fully Automatic Battery Charger - (1 Nos.)

-

-

-

... More
Digital type DC Voltmeter (0-50V) - (1 Nos.)

-

-

-

... More
Digital type DC Ammeter (0-10A) - (1 Nos.)

-

-

-

... More
DC Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
DC Selectro Switch (For Battery Charger On&Off) - (1 Nos.)

-

-

-

... More
Miscellaneous accessories

-

-

-

... More
Terminals, Jumper wires, Control wiring, HRC fuse link with Control Fuse, MCBs, Auxiliary Realys, Auxiliary Contactors, Space heaters, Control transformer, Illumination lamps and all other required Panel Miscellaneous accessories etc. - (1 Lot.)

-

-

-

... More
Provide minimum 4 Nos. or 20% spare terminals which ever is higher for control cables. - (1 Lot.)

-

-

-

... More
Note: Auto-Manual selector switch and Local-Remote (PLC) selector switch shall be provided for each AMF Panel, when selected in Auto mode, the panel shall operate through AMF relay & in manual mode, the Panel shall operate through manually, in manual mode through local-remote selector switch, in local mode panel shall operate through Panel Push-Button and in remote mode, panel shall operate through PLC.

1

1705652

1705652.54

... More
SAFETY ACCESSORIES

-

-

-

... More
Supply and fixing of fire extinguisher, dry chemical type 5.00 kg. Capacity (ISI mark) completes with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

5

16042

3208.47

... More
Providing and fixing H.T. danger notice plate of 250mmX200mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

371

123.73

... More
Providing and fixing M.V. danger notice plate of 200mmX150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

450

112.71

... More
Supply and fixing of shock treatment chart(prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.

2

345

172.88

... More
Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in- charge.

5

1135

227.12

... More
Supply and layfing of 1800mmX900mmX12mm thick chequered rubber matting of tested quality.

13

24336

1872.03

... More
Supply and fixing of 20 W fluorescent lamp operated emergency light with maintenance free battery for 3 hours opeation during mains power failure.

3

5827

1942.37

... More
First Aid box.

2

449

224.58

... More
11 kV Rubber Hand Gloves

2

422

211.02

... More
STRUCTURE STEEL

-

-

-

... More
Supply & Installation of Structure Steel required for support structure of equipments, LCS, cable, cable tray & earthing etc. for support on floor / wall / beam / brackets etc. including required welding/ cutting/ grinding shall be done to complete the job.

750

54660

72.88

... More
INSTRUMENT WORK

-

-

-

... More
PRESSURE MEASURMENT SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning of

-

-

-

... More
Pressure transmitter with indicator & all accessories

-

-

-

... More
at delivery of each Pump and common header.

-

-

-

... More
Range : 0 - 10 kg / sq.cm.

3

189793

63264.41

... More
PRESSURE GUAGE

-

-

-

... More
Supply, installation, testing & commissioning of

-

-

-

... More
Bourdan pressure guage having 150 mm dial with

-

-

-

... More
necessary S.S.cock at delivery line of each Pump.

-

-

-

... More
Range : 0 - 10 kg / sq.cm.

2

6581

3290.68

... More
PRESSURE SWITCH

-

-

-

... More
Supply, installation, testing & commissioning of

-

-

-

... More
Pressure switch at delivery line of each Pump.

-

-

-

... More
Range : 0 - 10 kg / sq.cm.(Adjustable type)

2

13466

6733.05

... More
FLOW MEASURING SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of

-

-

-

... More
Electromagnetic type flow meter with indiactor, transmitter and totaliser with all accessories and,

-

-

-

... More
hardwares, etc.complete in all respects.

-

-

-

... More
Size : 500 for manifold size 500 mm of R17 Header

1

369239

369239.83

... More
LEVEL MEASURING SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning

-

-

-

... More
Ultrasonic type Level transmitter with indicator and all

-

-

-

... More
required accessories & hardwares, etc. complete in

-

-

-

... More
all respects.

-

-

-

... More
Range : 0 - 6 Mtrs. Supply, installation, testing & commissioning of Float

1

114502

114502.54

... More
& Board type level indicator with all accessories.

-

-

-

... More
Range : 0 - 6 Mtrs. Supply, installation, testing & commissioning of Float

1

18852

18852.54

... More
type level switch with all accessories for Dry run

-

-

-

... More
protection of pumps. Range : 0 - 10 Mtrs.

1

5418

5418.64

... More
FRC ANALYZER Supply, installation, testing & commissioning of Amperometric type Free Chlorine Analyzer complete with transmitter, sensor, sensor cable, Sensor mounting assembly , accessories, hardware,consumables, etc. complete in all respects. Measuring Range : 0 - 5 mg/L

1

315699

315699.15

... More
PLC / SCADA FOR CONTROL ROOM

-

-

-

... More
Supply, installation, testing and commissioning of PLC-SCADA system including Instrument control Panel, PC based HMI along with 19" colour LCD Screen, Required programming / SCADA/Application Software, A3 Size Laser Printer, GSM-GPRS / Broadband based communication for Remote Data Transmission, Min. 1 kVA UPS (with 30 min backup alongwith suitable rating SMF batteries & battery charger and all other accessories as per standard), etc. complete in all respects and as per specifications. PLC shall have I/O count of 32 DI / 16 DO / 8 AI / 0AO.

1

832877

832877.12

... More
INSTRUMENT CABLES

-

-

-

... More
Supply, laying, testing and commissioning of Instrument Cables including termination & Trays

-

-

-

... More
3C X 2.5 sq.mm YWY Power cable

150

31906

212.71

... More
1P X 1.5 sq.mm Cu. Conductor,armoured ,overall & individual shieldedSignal cable

300

56694

188.98

... More
2C X 1.5 sq.mmCu. Conductor,armoured ,overall shielded Control cable

200

37288

186.44

... More
10C X 1.5 sq.mmCu. Conductor,armoured ,overall shielded Control cable

250

70762

283.05

... More
INSTRUMENT CABLE TRAY

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

30

11669

388.98

... More
200 mm width X 50 mm depth X 1.6 mm thickness

25

13559

542.37

... More
CABLE END TERMINATION AND CONNECTION :

-

-

-

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed copper conductor cable of 1.1kV grade as required.

-

-

-

... More
POWER CABLE

-

-

-

... More
3C x 2.5 sq.mm

6

971

161.86

... More
CONTROL CABLE

-

-

-

... More
2C x 1.5 sq.mm

6

864

144.07

... More
10C x 1.5 sq.mm

12

3233

269.49

... More
SIGNAL CABLE

-

-

-

... More
1P x 1.5 sq.mm.

12

1728

144.07

... More
ZONAL RESERVOIR (R18) CIVIL WORK

-

-

-

... More
SUB HEAD :- ERARTH WORK

-

-

-

... More
CARRIAGE OF MATERIALS (DSR-1.0/2013)

-

-

-

... More
By Mechanical Transport including loading, unloading and stacking (DSR-1.1/2013)

-

-

-

... More
Earth (10km) (DSR-1.1.2/2013)

58.39

6456

110.58

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areaa (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m diposed earth to be levelled and neatly dressed. (DSR-2.6/2013)

-

-

-

... More
All kinds of soil (DSR-2.6.1/2013)

115.68

6907

59.71

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m. (DSR-2.25/2013)

57.29

2623

45.79

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR-2.27/2013)

331.08

236708

714.96

... More
Clearing grass and removal of the rbbish upto a distance of 50m outside the periphery of the area cleared. (DSR-2.32/2013)

270.4

681

2.52

... More
SUB HEAD-II :- CONCRETE WORKS

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR-4.1/2013)

-

-

-

... More
1:4:8 (1 Cement :4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm (DSR-4.1.8/2013)

10.87

36116

3322.58

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (DSR-4.17/2013)

78.28

25138

321.14

... More
SUB HEAD-III :- REINFORCED CEMENT CONCRETE WORK

-

-

-

... More
Centering and shuttering including including strutting, propping etc. and removal of form for all heights including forming grooves as and whereever requried as per drawing. (DSR-5.9/2013)

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete. (DSR-5.9.1/2013)

100.98

15951

157.97

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR-5.9.2/2013)

-

-

-

... More
Suspended floors, roofs, landings, balconies and access platform (DSR-5.9.3/2013)

365.6

115193

315.08

... More
Shelves (Cast in situ) (DSR-5.9.4/2013)

36.56

11519

315.08

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR-5.9.5/2013)

361.47

94900

262.54

... More
Columns, Pillars, Piers, Abutments, Posts and Struts (DSR-5.9.6/2013)

120.12

43059

358.47

... More
Stairs, (excluding landings) except spiral-staircases (DSR-5.9.7/2013)

16.56

5271

318.35

... More
Edges of slabs and breaks in floors and walls. (DSR-5.9.16/2013)

-

-

-

... More
Under 20cms wide (DSR-5.9.16.1/2013)

53.53

5067

94.66

... More
Cornices and mouldings (DSR-5.9.17/2013)

-

-

-

... More
Weather shade, chajjas, corbels etc. including edges. (DSR-5.9.19/2013)

40.15

15930

396.78

... More
STEEL REINFORCEMENT

-

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR-5.22/2013)

-

-

-

... More
Thermo-Mechanically Treated bars (DSR-5.22.6/2013) (Sail Steel)

2062.13

116221

56.36

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR-5.22A/2013)

-

-

-

... More
Thermo-Mechanically Treated bars (DSR-5.22A.6/2013) (Sail Steel)

26333.6

1484161

56.36

... More
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. (DSR-5.30/2013)

53.53

1263

23.6

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. "(Note :-Cement content considered in this item is @ 330 kg/cum."Excess/less cement used as per design mix is payable/recoverable separately). (DSR-5.33/2013)

-

-

-

... More
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).

-

-

-

... More
All works upto plinth level (DSR-5.33.1/2013)

13.75

66471

4834.28

... More
All works above plinth level upto floor V level (DSR-5.33.2/2013)

175.56

945197

5383.9

... More
Extra for providing richer mixes at all floor levels. (DSR-5.34/2013)

-

-

-

... More
Note :- Excess/less cement over the specified cement content used is payable/recoverable separately.

-

-

-

... More
Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:-Cement content considered inM-30 is @ 340 kg/cum) (DSR-5.34.1/2013)

174.54

9487

54.36

... More
Providing M-40 grade concrete instead of M-25 grade BMC/RMC. (Note :- Cement content considered in M-40 is @ 360 kg/cum) (DSR-5.34.3/2013)

90.26

14725

163.14

... More
SUB HEAD-IV :- BRICK WORK

-

-

-

... More
Brick work with non modular fly ash bricks conforming to IS:12894, class designation10 average compressive strength in super structure above plinth level up to floor V level in : (DSR-6.34/2013)

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.34.2/2013)

234.12

1016647

4342.42

... More
SUB HEAD-VII :- WOOD AND PVC WORK

-

-

-

... More
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, window and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR-9.12/2013)

18

88

4.92

... More
SUB HEAD-VIII :- STEEL WORK

-

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part-1 and M.S. top cover of required thickness for rolling shutters. (DSR-10.6/2013)

-

-

-

... More
80X1.25 mm M.S. laths with 1.25 mm thick top cover (DSR-10.6.1/2013)

48.6

84191

1732.33

... More
Providing and fixing ball bearing for rolling shutters. (DSR-10.7/2013)

12

4440

370.04

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. (DSR-10.8/2013)

-

-

-

... More
Exceeding 10.00 sqm and upto 16.80 sqm in the area. (DSR-10.8.1/2013)

48.6

27409

563.98

... More
Extra for provding grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in-charge (area of grill to be measured). (DSR-10.9/2013)

24.3

6457

265.76

... More
SUB HEAD IX :- FLOORING

-

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR-11.3/2013)

-

-

-

... More
40mm thick with 20mm nominal size stone aggregate. (DSR-11.3.1/2013)

177.5

47653

268.47

... More
Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement :3 coarses sand) finished with a floating coat of neat cement (DSR-11.6/2013)

-

-

-

... More
18 mm thick (DSR-11.6.1/2013)

106

26877

253.56

... More
Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) (DSR-11.26/2013)

-

-

-

... More
25mm thick (DSR-11.26.1/2013)

36.12

32804

908.22

... More
Kota stone slabs 20mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polising complete. (DSR-11.27/2013)

3.61

3367

932.92

... More
Extra for pre finished nosing in treads of steps of Kota stone/sand stone slabs. (DSR-11.31/2013)

37.2

2157

58.01

... More
Extra for kota stone/sand stone in treads of steps and risers using single length up to 1.05 metre. (DSR-11.32/2013)

5.04

65

12.97

... More
Providing and laying vitrified floor tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.41/2013)

-

-

-

... More
Size of Tile 600X 600 mm (DSR-11.41.2/2013)

47.5

56458

1188.6

... More
Providing and laying vitrified tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.46/2013)

-

-

-

... More
Size of Tile 600X 600 mm (DSR-11.46.2/2013)

36.6

43778

1196.14

... More
SUB HEAD- X ROOFING

-

-

-

... More
Providing gola 75X75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (DSR-12.21/2013)

-

-

-

... More
In 75X75 mm deep chase (DSR-12.21.1/2013)

56.69

6146

108.43

... More
Providing and laying roof insulation with 40mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulaton conforming to IS- 12432 Pt. III (density of foam being 40-50 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providng a wearing coursed of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) in chequered rough finish, in panels of 2.5m X 2.5m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. (DSR-12.56/2013)

253.47

245576

968.86

... More
ROOFING SUB HEAD TOTAL

-

-

-

... More
SUB HEAD-XI :- FINISHING WORK

-

-

-

... More
12mm cement plaster of mix : (DSR-13.1/2013)

-

-

-

... More
1:6 (1 cement : 6 fine sand) (DSR-13.1.2/2013)

392.08

44473

113.43

... More
6 mm cement plaster of mix : (DSR-13.16/2013)

-

-

-

... More
1:3 (1 cement : 3 fine sand) (DSR-13.16.1/2013)

365.6

37287

101.99

... More
18 mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) (DSR-13.11/2013)

392.08

71570

182.54

... More
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: (DSR-13.24/2013)

-

-

-

... More
Is one coats (DSR-13.24.1/2013)

117.62

24620

209.32

... More
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR-13.80/2013)

392.08

28374

72.37

... More
Colour washing such as green, blue or buff to give an even shade (DSR-13.39/2013)

-

-

-

... More
New work (two or more coats) with a base coat of white washing with lime (DSR-13.39.1/2013)

392.08

6563

16.74

... More
Finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete. (DSR-13.52/2013)

-

-

-

... More
on steel work (DSR-13.52.1/2013)

40.5

3768

93.05

... More
On concrete work (DSR-13.52.2/2013)

4.05

392

96.86

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour. (DSR-13.81/2013)

-

-

-

... More
Two coats (DSR-13.81.2/2013)

757.68

26806

35.38

... More
SUB HEAD-XII:- SANITARY INSTALLATIONS

-

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vetreous china flushing cistrn & C.P. flush bend with fittings & C.I. brackets, 40mm fluh bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved muninipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: (DSR-17.3/2013)

-

-

-

... More
W.C. pan with ISI marked white solid plastic seat and lid (DSR-17.3.1/2013)

1

3929

3929.03

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430X260X350mm and 340X410X265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting an making good the walls and floors wherever required. (DSR-17.4/2013)

-

-

-

... More
One urinal basin with 5 litre white PVC automatic flushing cistern (DSR-17.4.1/2013)

2

5380

2690.34

... More
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. (DSR-17.7/2013)

-

-

-

... More
White Vitreous China Wash basin size 630X450mm with a pair of 15mm C.P. brass pillar taps (DSR-17.7.1/2013)

1

1842

1842.92

... More
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the receptin of pipes and fittings (DSR-17.8/2013)

1

824

824.11

... More
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete (DSR-17.28/2013)

-

-

-

... More
Flexible pipe (DSR-17.28.2/2013)

-

-

-

... More
32mm dia (DSR-17.28.2.1/2013)

1

61

61.48

... More
Providing and fixing 600X450 mm beveled edge mirror of superrior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete (DSR-17.31/2013)

1

645

645.97

... More
SUB HEAD-XII:- WATER SUPPLY

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (DSR-18.8/2013)

-

-

-

... More
Concealed work, including cutting chases and making good the wall etc.

-

-

-

... More
20 mm nominal outer dia Pipes (DSR-18.8.2/2013)

30

7152

238.43

... More
25 mm nominal outer dia Pipes (DSR-18.8.3/2013)

30

8548

284.96

... More
32 mm nominal outer dia Pipes (DSR-18.8.4/2013)

30

10357

345.25

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of E/I. (DSR-18.9/2013)

-

-

-

... More
100 mm nominal inner dia Pipes (DSR-18.9.9/2013)

30

71782

2392.75

... More
150 mm nominal inner dia Pipes (DSR-18.9.10/2013)

30

86664

2888.81

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931 (DSR-18.49/2013)

-

-

-

... More
15mm nominal bore (DSR-18.49.1/2013)

2

776

388.47

... More
Providing and fixing C.P. brass stop cock (conceale) of standard design and of approved make conforming to IS:8931 (DSR-18.52/2013)

-

-

-

... More
15mm nominal bore (DSR-18.52.1/2013)

2

1048

524.32

... More
SUB HEAD - XIV - DRAINAGE

-

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45X45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mm diameter, 1.8m long complete as per standard design (DSR-19.32/2013)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.32.1/2013)

1

14157

14157.16

... More
Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. (DSR-19.7/2013)

-

-

-

... More
Inside size 90X80 cm and 45 cm deep including C.I. cover with frame (light duty) 455X610mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg.) (DSR-19.7.1/2013)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.7.1.1/2013)

2

13665

6832.8

... More
Extra for depth for manholes: (DSR-19.8/2013)

-

-

-

... More
Size 90X80 cm (DSR-19.8.1/2013)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.8.1.1/2013)

0.15

696

4645.25

... More
SUB HEAD -XV : - ALUMINIUM WORK

-

-

-

... More
Providing and fixing aluminium work for door, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and joined mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/stainless steel screw, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and paneling to be paid for separately) (DSR-21.1/2013)

-

-

-

... More
For fixed portion (DSR-21.1.1/2013)

-

-

-

... More
Powder coated Aluminum (minimum thickness of powder coating 50 micron) (DSR-21.1.1.2/2013)

268.8

84967

316.1

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required (fittings shall be paid for separately) (DSR-21.1.2/2013)

-

-

-

... More
Powder coated Aluminum (minimum thickness of powder coating 50 micron)(DSR-21.1.2.2/2013)

149.76

54268

362.37

... More
Providing and fixing glazing in luminium door, windows, ventilator, shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings an the directions of the E/I (Cost of aluminium snap beading shall be paid in basic item) (DSR-21.3/2013)

-

-

-

... More
With float glass panes of 4.0mm thickness (DSR-21.3.1/2013)

89.86

60160

669.49

... More
With float glass panes of 5.50mm thickness (DSR-21.3.2/2013)

59.9

51219

855.08

... More
Filling the gap in between aluminuim frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of E/I complete (DSR-21.8/2013)

-

-

-

... More
Upto 5mm depth and 5mm width (DSR-21.8.1/2013)

66

4645

70.38

... More
SUB HEAD -XVI-WATER PROOFING WORK

-

-

-

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water profing compound conforming to IS. 2645 and approved by E/I over the RCC slab inclding adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admided with watr proofing compound conforming to IS 2645 and approved by E/I over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand)

-

-

-

... More
admixed with water proofing compound conforming to IS : 2645 and approved by E/I to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) after two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by E/I finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by E/I including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300X300 mm square 3mm deep) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curring and for final test. All above operations to be done in order and as directed and specified by the E/I. (DSR-22.7/2013)

-

-

-

... More
With average thickness of 120mm and minimum thickness at Khurra as 65mm (DSR-22.7.1/2013)

253.47

189587

747.97

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by E/I and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement 3 coarse sand) mixed with water proofing compound confirming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately) Joints saled and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (DSR-22.1/2013)

-

-

-

... More
Using rough kota stone (DSR-22.1.1/2013)

6

4292

715.34

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gap with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement 3 coarse sand) 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all level and as direction by E/I. (DSR-22.2/2013)

-

-

-

... More
Using rough kota stone (DSR-22.2.1/2013)

30

26361

878.73

... More
SUBMERSIBLE PUMP WITH MOTOR

-

-

-

... More
Supply, Erection, testing and commissioning of Submersible pump with CI casing, CF8 M impeller , SS 410 shaft, CI casing wearing ring & bearing bush, TC/ SIC mechanical seal, SS strainer etc suitable for 3 phase, 415 V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class H/F insulation as per specs and IP 68 protection. The pump shall be operated at suitable rpm as per data sheet. The scope includes all required accessories viz. automatic coupling device,G.I guide pipe, chain with shakle, flat/ round submersible cable upto starter panel through suitable size G.I. pipe with necessary electrical connection with the starter panel and as per specifications

-

-

-

... More
Capacity : 550 M³/hr

-

-

-

... More
Head : 42 mtrs.

-

-

-

... More
Motor Rating : 110 KW

3

4788307

1596102.54

... More
VALVES

-

-

-

... More
MOTOR OPERATED SLUICE VALVE

-

-

-

... More
Supply, installation, testing and commissioning of motor operated double flanged, C.I. Sluice Valve

-

-

-

... More
Size : 400 mm NB for Pump Discharge Line

3

910281

303427.12

... More
Size : 600 mm NB for Header

1

457833

457833.05

... More
Size : 450 mm NB for OHT

1

341579

341579.66

... More
Size : 450 mm NB for OHT

1

341579

341579.66

... More
CHECK VALVE

-

-

-

... More
Cast iron double flanged Single Door Swing Check Valve

-

-

-

... More
Size : 400 mm NB for Pump Discharge Line

3

538627

179542.37

... More
KINETIC AIR VALVE

-

-

-

... More
Supply, Installation, testing & commissioning of C.I. double acting kinetic Air Valve with isolation sluice valve.

-

-

-

... More
Size : 150 mm NB

1

61044

61044.92

... More
MANIFOLD PIPE & PIPE SPECIALS

-

-

-

... More
Supply, Fabrication, laying, testing and commissioning of M.S. pipe & specials with necessary supports & anchoring and including nuts, bolts and hardware

-

-

-

... More
Size : 400 mm NB for Pump Discharge Line

15

68783

4585.59

... More
Size : 600 mm NB for Header

30

240457

8015.25

... More
Supply, Fabrication, Fitting, testing and commissioning of Metallic Expansion Joint with necessary supports & anchoring and including nuts, bolts and hardware

-

-

-

... More
Size : 400 mm NB for Pump Discharge Line

3

141391

47130.51

... More
Supply, Fabrication, laying, testing and commissioning of pipe fittings and specials including Nuts, bolts and hardware

611

46600

76.27

... More
DEWATERING PUMP

-

-

-

... More
Supply, installation, testing & commissioning of non clog submersible dewatering pump to remove sand, silt, clay, sand, pebbles, small rock, algae, shells, plankton, etc. ( with specific gravity of up to 1.1 ) having CI casing, CF8 M impeller , SS 410 shaft, CI casing wearing ring & bearing bush,suitable for 3 phase, 415 V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class H/F insulation as per specs and IP 68 protection. The pump shall be operated at suitable rpm as per data sheet with all required accessories.

-

-

-

... More
Capacity : 50 mtr3/hr.

-

-

-

... More
Head : 10 mtrs.

-

-

-

... More
Motor Rating : 3.7KW

1

202104

202104.24

... More
E.O.T. CRANE WITH HOIST

-

-

-

... More
Supply, erection, testing and commissioning of fully electrically operated hoist, geared trolley, gantry girder, brake, safety device, locking arrangement, limit switch, pendant push button, starter panel, cables,and other required accessories.

-

-

-

... More
Capacity : 5.0 Ton. For Pump room

-

-

-

... More
Span : 9.5 mtrs.

-

-

-

... More
Lift :10.00 mtrs. (min)

1

845288

845288.14

... More
Supply, erection, testing and commissioning of fully electrically operated hoist, geared trolley, gantry girder, brake, safety device, locking arrangement, limit switch, pendant push button, starter panel, cables,and other required accessories.

-

-

-

... More
Capacity : 2.0 Ton.

-

-

-

... More
Lift :5.00 mtrs. (min)

1

441855

441855.93

... More
CHLORINATION PLANT

-

-

-

... More
Supply, installation, testing & commissioning of vacuum control floor mounted gas chlorinator system including necessary fittings, clamp, copper pipe, ferule filter & control valve with injector with required booster pump, set of diffuser entire associated water & chlorine soulution piping upto diffuser etc, valves,automatic change over ,Chlorine absorption system, saftey & testing kit, etc. complete in all respect as per specs & as per following capacity

-

-

-

... More
Capacity : 2 x 5 kg/hr

1

3161288

3161288.14

... More
Supply, erection, testing and commissioning of single girder electrically operated hoist, geared trolley, brake, safety device, locking arrangement, limit switch, pendant push button, starter panel, cables,and other required accessories.

-

-

-

... More
Capacity : 3.0 Ton.for Chlorination plant

1

538627

538627.12

... More
Span : 5.0 mtrs.(max)

-

-

-

... More
Lift :10.00 mtrs. (min)

-

-

-

... More
900 kg. Chlorine Tonners duly approved by dept. of explosive

2

237288

118644.07

... More
ELECTRICAL WORK

-

-

-

... More
H.T. INDOOR SWITCH GEAR PANEL

-

-

-

... More
Supply, Installation, Testing and Commissioning (SITC) of 11 kV, 350 MVA, 400 A, indoor, drawout type Three HT Vaccuum Circuit Breaker Panel (single breaker) with CT and PT of appropriate rating for metering and protection along with required Indicating lamps, protection relay and Indicating meters, etc. complete in all respects as per IS, Specification.

1

358785

358785.59

... More
H.V. CABLES

-

-

-

... More
Supply, delivery, laying testing & commissioning of 11KV (E), XLPE cable having compacted circular staranded aluminium conductor, conductor screening of extruded semi conducting compound, cross linked polythylane (XLPE), insulation screening of the extruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments) for following mentioned sizes. It should be operational at 11 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on sides and

-

-

-

... More
top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I. Complete in all respect. The price are inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respects and as per requirement of the job.

-

-

-

... More
(CCI (Bombay/Nashik), Fort Gloster (Calcutta / Baripara), Asian (Thane / Silvasha), Universal (Satna), Nicco (Calcutta), ICL (Rajpura), Diamond, Havells make SOR-3

-

-

-

... More
3CX240 Sqmm.

60

98085

1634.75

... More
Supply, Delivery, Installation, Testing & Commissioning of 11KV, indoor type cable termination kit of 3 core cable for cable termination at the panel & transformer complete in all respects as required for proper completion of work. (450mm length) SOR-5 (make Raychem/C.C.I./Frontec) d) 3CX240 Sq.mm.

4

36640

9160.17

... More
DISTRIBUTION TRANSFORMER

-

-

-

... More
Supply, delivery, assembly, installation, testing and commissioning of indoor type distribution transformer. 11/0.433 KV, 3 Phase, Double wound winding. Voltage ratio 11000/433- 250 Volts, vector group Dyn 11. Air cooled with manually operated +5% and +10% off load Tap changer and complete with standard fitting & accessories as given in the specification and also confirming to ISS : 2026 with firsh filling of the oil complete as required. (This includes oil testing for dielectric strength, flask over test and filtration of transformer oil to be conducted in the event of unsatisfactory results of oil testing. (Crompton, NGEF, Alstom, BHEL, Voltamp, Diamond, Reychem, Kanohar make) SOR-13 Copper wound (a) 400 KVA

1

653146

653146.61

... More
Supply and levelling of transformer yard using gravel, fine sand and other required filing material, enmarked for the switchyard including removing of trees or boulders if any etc. The general level of the yard shall be at a convenient level for movement of man and material and it should match with FGL.

40

10576

264.41

... More
Supply and Installation of Chain link fencing around switch yard etc. as per Specification.

25

21589

863.56

... More
SITC of 2.5 mtr wide gate with required material as per Specification.

1

8633

8633.9

... More
SITC of Medium Voltage Panel Board

-

-

-

... More
MEDIUM VOLTAGE PANEL BOARD

-

-

-

... More
Panel Board Encloser & Bus-Bar

-

-

-

... More
Supplying, Installation, Testing and Commissioning of Indoor floor mounted totally enclosed, compartmentalized, extendable type PCC / PMCC / MCC Cubicle Panel Board having 36 MVA, 50A breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum 0.8 A/mm2 current density,

-

-

-

... More
extensible type, DMC/SMC busbar supports, suitable for 3 phase-neutral 415 V, 50 HZ AC supply i/c providing and fixing the following switchgears mounted thereon complete with gaskets and interconnections, connections as per specifications complete as required. (The board shall be dust & vermin proof with degree of protection of IP 52 as per IS:12063, free standing type, mounted on base channel of MS Section not less than 100 mm X 50 mm X 5 mm), Isolated cubical compartment for fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.5.5M length X 1M Min.Width X Maximum 2.3M Height with base channel)

-

-

-

... More
630 rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (All bus bars shall be considering Maximum Current Density 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (8 Mtr.)

-

-

-

... More
Incoming Section

-

-

-

... More
Incomer Breaker for Transformer (Qty.1 Nos.)

-

-

-

... More
4 Pole ACB - 630A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
3-Phase Digital Type Multifunction Meter (96x96Sqmm.), Accuracy. Class-0.5S (for Active) suitable to measure kVA, kW, kWH, kVAr, kVArH, A,V, P.F. & Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos.)

-

-

-

... More
630/5A, CL 0.5, 15VA for Metering CTs - (3 Nos.)

-

-

-

... More
630/5A, CL.0.5 15VA, CTs for APFC relay - (3 Nos.)

-

-

-

... More
On / Off / Trip / Spring charge LED type Indication Lamp, 220VAC 22.5mm. - (4 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
R,Y,B Led Indication Lamp, 220VAC 22.5mm, - (3 Nos.)

-

-

-

... More
Digital Voltmeter ( 0-500 V) with control fuses. - (1 Nos.)

-

-

-

... More
Digital Ammeter ( 0-630 A) with control fuses. - (1 Nos.)

-

-

-

... More
Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.)

-

-

-

... More
DG Incomer Breaker D.G (Qty.1 No.)

-

-

-

... More
4 Pole ACB - 630A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
630/5A, CL 0.5, 15VA, Metering CTs - (3 Nos.)

-

-

-

... More
On / Off / Trip / Spring charge LED type Indication Lamp, 220VAC 22.5mm. - (4 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (3 Nos.)

-

-

-

... More
R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.)

-

-

-

... More
Digital Voltmeter ( 0-500V) with control fuses. - (1 Nos.)

-

-

-

... More
Digital Ammeter ( 0-630A) with control fuses. - (1 Nos.)

-

-

-

... More
Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.)

-

-

-

... More
Transformer No-load losses comp. Fixed Capacitors for Tran. (Qty.1 Nos.)

-

-

-

... More
63A 3P MCB, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
20 kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Timer for Capacitor - (1 Nos.)

-

-

-

... More
R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.)

-

-

-

... More
On LED type Indication Lamp, 220VAC 22.5mm. - (1 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
20A MCB for Capacitor - (1 Nos.)

-

-

-

... More
16A MCB for Capacitor - (1 Nos.)

-

-

-

... More
6A MCB for Capacitor - (1 Nos.)

-

-

-

... More
10 kVAR APP. Type Capacitor - (1 Nos.)

-

-

-

... More
10 kVAR APP. Type Capacitor - (1 Nos.)

-

-

-

... More
3 kVAR APP. Type Capacitor - (1 Nos.)

-

-

-

... More
Outgoing Section

-

-

-

... More
210A Soft-Starter for 132kW (Suitable for 110kW Moto after derating) Feeder Each Comprising of following: (Qty. 3 Sets.)

-

-

-

... More
350A TP MCCB, 36 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
325A Three Pole AC-3 duty line Contactor - (1 Nos.)

-

-

-

... More
630A Semiconductor (FA) Bussmann fuse type 170M5012 & Fuse Holder-170H3004 - (3 Nos.)

-

-

-

... More
210A Soft-Starter for 132kW (Suitable for 110kW Moto after derating) - (1 Nos.)

-

-

-

... More
325A Three Pole AC-3 duty By Pass Contactor of Soft Starter - (1 Nos.)

-

-

-

... More
350/5A, CL 0.5, Metering CTs - (3 Nos.)

-

-

-

... More
On / Off / Trip LED type Indication Lamp, 220VAC 22.5mm. - (3 Nos.)

-

-

-

... More
Stat Push Button - (1 Nos.)

-

-

-

... More
Stop Push Button - (1 Nos.)

-

-

-

... More
Digital Ammeter ( 0-350A) with control fuses. - (1 Nos.)

-

-

-

... More
Selectro Switch (Ammeter) - (1 Nos.)

-

-

-

... More
Selectro Switch (Auto/Manual, Local/remote) - (2 Nos.)

-

-

-

... More
Pump Protection Unit - (1 Nos.)

-

-

-

... More
(MPR + SPP) with CBCT - (1 Nos.)

-

-

-

... More
2.5A TP MPCB with Thermostate and 2 nos. Cooling fan (CFM-105) for Starter Enclosure etc. - (1 Lot)

-

-

-

... More
APFC Panel feeder (For 105 kVAR APFC Panel) - (Qty. 1 No.)

-

-

-

... More
200 A TPN MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.)

-

-

-

... More
On / Off LED type Indication Lamp, 220VAC 22.5mm. - (2 Nos.)

-

-

-

... More
63 A (415V) TPN 'C' Curve MCB Feeders - (2 Nos.)

-

-

-

... More
32 A (415V) TPN 'C' Curve MCB Feeders - (10 Nos.)

-

-

-

... More
Power Feeders

-

-

-

... More
32 TPN MCB Feeders for Incomer - (1 Nos.)

-

-

-

... More
On / Off LED type Indication Lamp, 220VAC 22.5mm for (a) Incommer - (2 Nos.)

-

-

-

... More
6A TPN 'C' Curve MCB - (6 Nos.)

-

-

-

... More
Miscellaneous accessories

-

-

-

... More
Terminals, Jumper wires, Control wiring, HRC fuse link with Control Fuse, Space heater, Control Transformer, Illumination lamp and all other required Panel Miscellaneous accessories etc.. - (1 Lot)

-

-

-

... More
i) Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables. ii) Provide terminals for Trip interlock for future use. ( Spare shall be supplied with short link) - (1 Lot)

-

-

-

... More
Note: i) Auto/Manual and Local / Remote selector switches shall be provided for all starters which shall operate through PLC when selected in Auto Mode. In manual mode the drive shall operate through manually through MCC-PB or through LCS-PB. When Local / Remote switch is selected in local mode or remote mode respectively. Potential free contacts shall be provided to monitor drive status signals (A/M switch status, drive On/Off status and drive trip status) at PLC. ii) Low level switch for dry run protection pumps shall be interlocked at respective starters through provision of required relays and relay based logic for pumps tripping at ICP.

1

2312755

2312755.93

... More
APFC PANEL BOARD (105 kVAR - 8 STEP)

-

-

-

... More
Panel Board Encloser & Bus-Bar

-

-

-

... More
Supplying, Installation, Testing and Commissioning of Indoor floor mounted totally enclosed, compartmentalized type APFC Cubicle Panel Board having 36 MVA breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum 0.8 A/mm2 current density, extensible type, DMC/SMC

-

-

-

... More
busbar supports, suitable for 3 phase- neutral 415 V, 50 HZ AC supply I/c providing and fixing the following switchgears & capacitors mounted there on complete with gaskets and interconnections, connections as per specifications complete as required. (The APFC Panel board shall be dust & vermin proof with degree of protection of IP 42 as per IS:12063, free standing type, mounted on base channel of MS Section not less than 100 mm X 50 mm X 5 mm) and as per IS, Specification (Mini.1.2M length X Min. 750M Width X Maximum 2M Height with base channel)

-

-

-

... More
200A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (All bus bars shall be considering Maximum Current Density 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (2.00 Mtr)

-

-

-

... More
Incoming Section

-

-

-

... More
Incomer Breaker for APFC (Qty. 1 No.)

-

-

-

... More
200 A 3P+N MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. For On / Off / Trip - (3 Nos)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm For R, Y, B - (3 Nos)

-

-

-

... More
HRC Control fuses with fuse base (6A) for voltmeter, Ameter, APFC relay - (9 Nos)

-

-

-

... More
Digital Voltmeter (0-500V) - (1 Nos)

-

-

-

... More
200/5A, CL-1, 15VA, Metering CTs - (3 Nos)

-

-

-

... More
Digital Ammeter (0-200A) - (1 Nos)

-

-

-

... More
Selectro Switch (For Auto / Manual) - (1 Nos)

-

-

-

... More
APFC Relay

-

-

-

... More
8-Step Microprocessor Based APFC Relay - (1 Nos)

-

-

-

... More
Outgoing Section

-

-

-

... More
20kVAR Capacitors feeders Each Comprising of following: (Qty. 2 Sets.)

-

-

-

... More
40A 3P MCB for Capacitor - (1 Nos)

-

-

-

... More
20kVAR Capacitor Duty Contactor - (1 Nos)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos)

-

-

-

... More
20kVAR Double layer APP Type Capacitor - (1 Nos)

-

-

-

... More
15kVAR Capacitors feeders Each Comprising of following: (Qty. 2 Sets.)

-

-

-

... More
32A 3P MCB for Capacitor - (1 Nos)

-

-

-

... More
15kVAR Capacitor Duty Contactor - (1 Nos)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos)

-

-

-

... More
15kVAR Double layer APP Type Capacitor - (1 Nos)

-

-

-

... More
10kVAR Capacitors feeders, Each Comprising of following: (Qty. 3 Sets.)

-

-

-

... More
32A 3P MCB for Capacitor - (1 Nos)

-

-

-

... More
10kVAR Capacitor Duty Contactor - (1 Nos)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos)

-

-

-

... More
10kVAR Double layer APP Type Capacitor - (1 Nos)

-

-

-

... More
5kVAR Capacitors feeders, Qty. 1 No.

-

-

-

... More
16A 3P MCB for Capacitor - (1 Nos)

-

-

-

... More
5kVAR Capacitor Duty Contactor - (1 Nos)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos)

-

-

-

... More
5kVAR Double layer APP. Type Capacitor - (1 Nos)

-

-

-

... More
Miscellaneous APFC Panel Accessories

-

-

-

... More
Terminals, Jumper wires, Control wiring, HRC fuse link with Control Fuse, Space heater, Control Transformer, Illumination lamp and all other required Panel Miscellaneous accessories etc.. - (1 Lot)

-

-

-

... More
Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables. - (1 Lot)

-

-

-

... More
Note: Auto/Manual selector switches shall be provided for Auto/Manual mode of opearation to operate APFC Panel through APFC Relay when selected in Auto Mode & in manualy when selected Manual mode. - (1 Lot)

1

286792

286792.37

... More
LDB / PDB / JB / LCS

-

-

-

... More
SITC of Lighting Distribution Board as under: Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Single door

1

3488

3488.98

... More
Incoming Section

-

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

1

1803

1803.39

... More
Outgoing Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

24

2969

123.73

... More
SITC of Outdoor Lighting Distribution Board as under: Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/recess complete with loose wire box of sheet steel, dust protected,duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way Double door

1

8969

8969.5

... More
Incoming Section

-

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

1

1563

1563.56

... More
32A Contactor

1

1588

1588.98

... More
Time switch.

1

1697

1697.46

... More
Outgoing Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral

8

5315

664.41

... More
SITC of Power Distribution Board as under: Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s,terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way Single door

1

10844

10844.92

... More
Incoming Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral

1

664

664.41

... More
Outgoing Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

12

6203

516.95

... More
SITC of stand / wall mounting Junction Box with Protection Class of IP-65, fault level-25kA with steel structure stand etc. for Termination of 1.1 kV Submersible Flexible Copper Power & Control cable with (A) One run 3C x 185 sq.mm A2XFY power cable.

3

15485

5161.86

... More
SITC of stand / wall mounting Junction Box with Protection Class of IP-65, fault level-25kA with steel structure stand etc. for Termination of 1.1 kV Submersible Flexible Copper Power and / or Control cable with (A) 5C x 2.5/1.5 sq.mm ywy control cable.

3

11715

3905.08

... More
SITC of Pendant type ON_OFF pushbutton set complete with Enclouser, necessary mounting/ fixing arrangement on wall / pipe support etc. to be installed near motors for remote operation, etc. as per IS and specifications

3

7810

2603.39

... More
MEDIUM VOLTAGE CABLES

-

-

-

... More
Supply & laying of aluminum conductor PVC insulated armoured served sheathed cables 1100 Volts grate at a depth of below ground level over a cushion of 75 mm. below ground level over a cushion of 75 mm. thick sand all round and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer – in charge, complete in all respected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.

-

-

-

... More
300sq. mm. 3-1/2 core

190

325737

1714.41

... More
185sq. mm. 3-1/2 core

165

186674

1131.36

... More
150sq. mm. 3-1/2 core

25

23453

938.14

... More
6 sq.mm. 4 core

200

41356

206.78

... More
4 sq.mm. 3 core

100

18220

182.2

... More
SITC of 1.1 kV, YWY / PVC insulated (IS 1554) Cu conductor cables as per specification & IS.

-

-

-

... More
3C x 2.5 sq. mm. YWY Cable

550

85294

155.08

... More
4C x 2.5 sq. mm. YWY Cable

720

135460

188.14

... More
5C x 1.5 sq.mm. YWY Cable

165

26428

160.17

... More
10C x 1.5 sq.mm. YWY Cable

70

19695

281.36

... More
CABLE END TERMINATION AND CONNECTION:

-

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required.

-

-

-

... More
3½ X 300 sq. mm (70mm)

12

9559

796.61

... More
3½ X 185 sq. mm (57mm)

6

3411

568.64

... More
3½ X 150 sq. mm (50mm)

2

849

424.58

... More
Supply & fixing of brass nickel plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects .The armoured of the cable shall be properly connected with the earth as per direction of Engineer – in charge.

-

-

-

... More
6sq.mm. 4 core

8

400

50

... More
4sq.mm. 3 core

2

79

39.83

... More
Supply & fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of Engineer – in charge.

-

-

-

... More
6sq.mm.

32

325

10.17

... More
4sq.mm.

6

61

10.17

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed copper conductor cable of 1.1kV grade as required.

-

-

-

... More
3C x 2.5 sq. mm. YWY Cable

14

2384

170.34

... More
4C x 2.5 sq. mm. YWY Cable

32

5450

170.34

... More
5C x 1.5 sq.mm. YWY Cable

6

879

146.61

... More
10C x 1.5 sq.mm. YWY Cable

4

996

249.15

... More
CABLE TRAY

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

50

48220

964.41

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

45

32071

712.71

... More
150 mm width X 50 mm depth X 1.6 mm thickness

50

22161

443.22

... More
EARTHING

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

12

90905

7575.42

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

10

31805

3180.51

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

105

135165

1287.29

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

75

6546

87.29

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

100

2881

28.81

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

100

11525

115.25

... More
50 x 6 GI strips

200

37628

188.14

... More
INTERNAL WIRING

-

-

-

... More
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

47

28956

616.1

... More
Supply and wiring of submain with four no. 2.5 sq.mm. FR PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2mm thick) PVC conduit with two no. 1.5 sq.mm. FR PVC insulated 1100 V grade multistrand copper conductor as earth continuity wire drawn inside the conduit.

250

37077

148.31

... More
Wiring for Circuit / Submain wiring along with earth wire with the (2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire) sizes of FRLS insulated copper conductor, Single core cable in Surface / recessed medium class PVC Conduit as required.

165

19575

118.64

... More
Supply and fixing of 25 mm sizes of medium Class PVC Conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

165

10068

61.02

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

2

1325

662.71

... More
Supply and fixing of following size / modules, GI Box along with modular base & cover plate for modular switches in recess etc. as required. (For 15/16A and 5A/6A Switch & Socket)

-

-

-

... More
(a) 8 Module (125mm x 125mm)

14

3215

229.66

... More
(b) 3 Module (100mm x 75mm)

12

1749

145.76

... More
Supply and fixing of following Modular Switch / Socket on the modular plate & Switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
6 pin 15/16 Amp Socket outlet

26

3591

138.14

... More
15/16 Amp Switch

26

2511

96.61

... More
3 pin 5/6 Amp Socket outlet

14

1198

85.59

... More
5/6 Amp Switch

14

913

65.25

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

674

674.58

... More
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (Pump house & Panel room)

3

5481

1827.12

... More
Supplying and fixing TP sheet steel enclosure on surface/recess along with 16/25/32amps 415 volts “C” curve TP MCB complete with connections, testing and commissioning etc. as required. (For Ele. Hoist etc.)

3

2161

720.34

... More
INTERNAL LIGHT FIXTURES

-

-

-

... More
Supply and fixing of factory wired HPF industrial type fluorescent tube light fitting with vitreous enameled reflector suitable for 2X40 w fluorescent tube including tubes etc. on surface complete in all respects. Cat AA (seg.)

21

29097

1385.59

... More
Supply and fixing of factory wired, surface type mirror optic fittings made of pre anodized aluminium section with P2 / P5 louvers suitable for & with 2no.36 w CFL complete in all respect. Cat AA

2

9911

4955.93

... More
Supply and fixing of factory wired asymmetrical beamed integral flood light luminaires with die cast aluminium housing & A1 .reflector having built in control gear unit duly pre wired plate complete with ballast, ignitor ,capacitor for 1*150 w M.H. with lamp complete in all respect. Cat AA

3

14761

4920.34

... More
Supply and fixing of industrial bulk head fitting with polycarbonate base guard, prismatic reflector silicon gasket suitable for and with 1X18 w CFL complete in all respect. Cat A

2

1203

601.69

... More
380mm sweep 1400 R.P.M exhaust fan, capacitor type, having double ball bearing, M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC supply conforming to IS: 2312.Fan shall be painted with epoxy grey colour controlled by one 6 A flush type switch on board and 6A plug point near Ex. fan.

6

12716

2119.49

... More
1200mm sweep ceiling fan, capacitor type, having double ball bearing 450mm down rod, canopies, shackle, rubber bush, blades, electronic speed regulator, suitable to operate on 230V,50Hz AC supply conforming to IS: 374/1979.Fan shall be painted with white colour.

3

3775

1258.47

... More
EXTERNAL LIGHT FIXTURES

-

-

-

... More
Supply and fixing of factory wired asymmetrical beamed integral flood light luminaires with die cast aluminium housing & A1 .reflector having built in control gear unit duly pre wired plate complete with ballast, ignitor ,capacitor for 1*150W M.H. with lamp complete in all respect. Cat AA

8

36881

4610.17

... More
Supply & erection of Steel tubular single wing pole with 30cm around & 1/6 over all length of pole grouted with cement concrete in 1:3:6 (1 cement : 3 coarse sand : 6 stone ballast) including plinthing of pole & 15cm around & 30 cm above the ground level, plastering of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. required for proper completion of work as per direction of E/I. SOR-20 a) 410 SP-17, 8.5mtr., 92kg.

6

44745

7457.63

... More
Supply and fixing of factory wired sodium vapour lamp street light luminaries single piece cast “Aluminium” body suitable for 70w S.V. lamp including integral control gear, 70w S.V. lamp on G.I. pipe bracket complete in all respects on on pole.

6

21203

3533.9

... More
Supply and fixing of H.P.M.V. post top lantern, suitable for 80w M.V. lamp complete with control gear pole mounting box and 80 w M.V. lamps etc. complete in all respects. Cat AA (seg.)

2

5108

2554.24

... More
DIESEL GENERATOR WITH AMF PANEL SET

-

-

-

... More
SITC OF DIESEL GENERATOR WITH ENGINE, ALTERNATOR & DG CONTROLLER SET

-

-

-

... More
SITC of 365 KVA DG set or higher rating (as required to run complete working load of pumping station including lighting.) 415 V,50 Hz,3 Phase, 4 wire Diesel Generator (Engine, Alternator & DG Controller) Set. Diesel engine shall be complete with necessary controls and safety devices confirming to relevent ISS/BSS with latest amendements. Diesel Engine shall be suitable for continuous operation of generator set duty inclusive of fly wheel, air cleaner, radiator.fan with guard,fuel pump,fuel filter,Electronic governor,electrical starting system with starter,12 V battery, voltage regulator,instrument panel, Exhaust silencer, protections against low lubrication oil pressure,high water temperature.

-

-

-

... More
Alternator shall be 415V, 3 phase, 50 Hz, 4 wire, 0.8 power factor, self excited,self regulated,brushless type,drip proof confirming to IS:4722 with latest amendments. DG set shall comply latest emission norms of Ministry of Environment & Forest (MOEF) by Government of India, effective from July 2014. DG set engine shall be manufactured as per present CPCB norms. DG set rating shall be for prime rating power (PRP) in accordance with BS 5514 / IS / ISO. DG set shall meet all statutory / pollution control regulation requirement with all currently applicable statutory norms, regulations and safety codes of the latest applicable Indian Standards.

-

-

-

... More
The engine and alternator shall be coupled over a sturdy common base frame. Day fuel tank with necessary fuel to hoses the engine fule and complete in all respect as required. DG set shall be along with acoustic enclosure / canopy and suitable for outdoor mounting.

-

-

-

... More
SITC OF AMF PANEL

-

-

-

... More
Panel Board Encloser & Bus-Bar

-

-

-

... More
Supplying, Installation, Testing and Commissioning of Indoor floor mounted totally enclosed, compartmentalized, extendable type AMF Panel Board having 36 MVA, 50 kA breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with electrolytic grade high conductivity PVC sleeved aluminium (E91

-

-

-

... More
E) busbars, DMC/SMC busbar supports, suitable for 3 phase- neutral 415V, 50 HZ AC supply i/c providing and fixing the following switchgears mounted thereon complete with gaskets and interconnections, connections as per specifications complete as required. (The board shall be dust & vermin proof with degree of protection of IP 52 as per IS:12063, free standing type, mounted on base channel of MS Section not less than 100 mm X

-

-

-

... More
50 mm X 5 mm), Isolated cubical compartment for fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.0.8M length X 0.75M Min.Width X Maximum 2.3M Height with base channel)

-

-

-

... More
630A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (All bus bars shall be considering Maximum Current Density 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (1.50 Mtr)

-

-

-

... More
DG Incomer Breaker, (Qty. 1 Set)

-

-

-

... More
4Pole ACB - 630A, 50 kA, with Micro Processor based releases (Overload, Short Circuit and earth fault protetive release) etc. - (1 Set)

-

-

-

... More
3-Phase Digital Type Multifunction Meter (96x96Sqmm.), Accuracy Class-1, suitable to measure A,V, P.F. & Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos)

-

-

-

... More
3-Phase Digital Type Trivector / Energy Meter, Accuracy Class- 0.5S (For Active), suitable to measure kVA, kW, kWH, kVAr, kVArH, P.F. & Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos)

-

-

-

... More
630/5A, Core-1 CL 0.5, 15VA for Metering - (3 Nos)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (6 Nos)

-

-

-

... More
Digital Voltmeter (0-500V) with control fuses. - (1 Nos)

-

-

-

... More
Digital Ammeter (0-630A) with control fuses. - (1 Nos)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm for On / Off / Trip / Spring charge - (4 Nos)

-

-

-

... More
LED Indication Lamp, 220VAC 22.5mm for R,Y,B - (3 Nos)

-

-

-

... More
LED Indication Lamp, 220VAC 22.5mm for Load ON, Control ON, Breaker ON & OFF - (4 Nos)

-

-

-

... More
Push Button for Engine Start & Stop, Emergency Stop, ACB Trip & Closed, Hooter Accept - (6 Nos)

-

-

-

... More
Selectro Switch for Ammeter, Voltmeter, Control Supply On&Off, Auto-Manual mode, Local-Rermote (PLC) mode. - (5 Nos)

-

-

-

... More
Automatic Mains Failure (AMF) Digital Relay - (1 Nos)

-

-

-

... More
Line Voltage Monitoring digital Relay - (1 Nos)

-

-

-

... More
Fully Automatic Battery Charger - (1 Nos)

-

-

-

... More
Digital type DC Voltmeter (0-50V) - (1 Nos)

-

-

-

... More
Digital type DC Ammeter (0-10A) - (1 Nos)

-

-

-

... More
DC Control HRC fuses with fuse base (6A) - (6 Nos)

-

-

-

... More
DC Selectro Switch (For Battery Charger On&Off) - (1 Nos)

-

-

-

... More
Miscellaneous accessories

-

-

-

... More
Terminals, Jumper wires, Control wiring, HRC fuse link with Control Fuse, MCBs, Auxiliary Realys, Auxiliary Contactors, Space heaters, Control transformer, Illumination lamps and all other required Panel Miscellaneous accessories etc. - (1 Lot)

-

-

-

... More
Provide minimum 4 Nos. or 20% spare terminals which ever is higher for control cables. - (1 Lot)

-

-

-

... More
Note: Auto-Manual selector switch and Local-Remote (PLC) selector switch shall be provided for each AMF Panel, when selected in Auto mode, the panel shall operate through AMF relay & in manual mode, the Panel shall operate through manually, in manual mode through local-remote selector switch, in local mode panel shall operate through Panel Push-Button and in remote mode, panel shall operate through PLC.

1

3303579

3303579.66

... More
SAFETY ACCESSORIES

-

-

-

... More
Supply and fixing of fire extinguisher, dry chemical type 5.00 kg. Capacity (ISI mark) completes with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

5

16042

3208.47

... More
Providing and fixing H.T. danger notice plate of 250mmX200mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

371

123.73

... More
Providing and fixing M.V. danger notice plate of 200mmX150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

450

112.71

... More
Supply and fixing of shock treatment chart(prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.

2

345

172.88

... More
Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in- charge.

5

1135

227.12

... More
Supply and layfing of 1800mmX900mmX12mm thick chequered rubber matting of tested quality.

13

24336

1872.03

... More
First Aid box.

2

449

224.58

... More
Supply and fixing of 20 W fluorescent lamp operated emergency light with maintenance free battery for 3 hours opeation during mains power failure.

3

5827

1942.37

... More
11 kV Rubber Hand Gloves

2

422

211.02

... More
STRUCTURE STEEL

-

-

-

... More
Supply & Installation of Structure Steel required for support structure of equipments, LCS, cable, cable tray & earthing etc. for support on floor / wall / beam / brackets etc. including required welding/ cutting/ grinding shall be done to complete the job.

750

54660

72.88

... More
INSTRUMENT WORK

-

-

-

... More
PRESSURE MEASURMENT SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning of

-

-

-

... More
Pressure transmitter with indicator & all accessories

-

-

-

... More
at delivery of each Pump and common header.

-

-

-

... More
Range : 0 - 10 kg / sq.cm.

4

253057

63264.41

... More
PRESSURE GUAGE

-

-

-

... More
Supply, installation, testing & commissioning of

-

-

-

... More
Bourdan pressure guage having 150 mm dial with

-

-

-

... More
necessary S.S.cock at delivery line of each Pump.

-

-

-

... More
Range : 0 - 10 kg / sq.cm.

3

9872

3290.68

... More
PRESSURE SWITCH

-

-

-

... More
Supply, installation, testing & commissioning of

-

-

-

... More
Pressure switch at delivery line of each Pump.

-

-

-

... More
Range : 0 - 10 kg / sq.cm.(Adjustable type)

3

20199

6733.05

... More
FLOW MEASURING SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of

-

-

-

... More
Electromagnetic type flow meter with indiactor, transmitter and totaliser with all accessories and,

-

-

-

... More
hardwares, etc.complete in all respects.

-

-

-

... More
Size : 450 for manifold size 450 mm of R18 Header

1

355126

355126.27

... More
LEVEL MEASURING SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning

-

-

-

... More
Ultrasonic type Level transmitter with indicator and all

-

-

-

... More
required accessories & hardwares, etc. complete in

-

-

-

... More
all respects.

-

-

-

... More
Range : 0 - 6 Mtrs. Supply, installation, testing & commissioning of Float

1

114502

114502.54

... More
& Board type level indicator with all accessories.

-

-

-

... More
Range : 0 - 6 Mtrs. Supply, installation, testing & commissioning of Float

1

18852

18852.54

... More
type level switch with all accessories for Dry run

-

-

-

... More
protection of pumps. Range : 0 - 10 Mtrs.

1

5418

5418.64

... More
FRC ANALYZER Supply, installation, testing & commissioning of Amperometric type Free Chlorine Analyzer complete with transmitter, sensor, sensor cable, Sensor mounting assembly , accessories, hardware,consumables, etc. complete in all respects. Measuring Range : 0 - 5 mg/L

1

315699

315699.15

... More
PLC / SCADA FOR CONTROL ROOM

-

-

-

... More
Supply, installation, testing and commissioning of PLC-SCADA system including Instrument control Panel, PC based HMI along with 19" colour LCD Screen, Required programming / SCADA/Application Software, A3 Size Laser Printer, GSM-GPRS / Broadband based communication for Remote Data Transmission, Min. 1 kVA UPS (with 30 min backup alongwith suitable rating SMF batteries & battery charger and all other accessories as per standard), etc. complete in all respects and as per specifications. PLC shall have I/O count of 44 DI / 18 DO / 12 AI / 0AO.

1

847838

847838.98

... More
INSTRUMENT CABLES

-

-

-

... More
Supply, laying, testing and commissioning of Instrument Cables including termination & Trays

-

-

-

... More
3C X 2.5 sq.mm YWY Power cable

150

31906

212.71

... More
1P X 1.5 sq.mm Cu. Conductor,armoured ,overall & individual shieldedSignal cable

350

66143

188.98

... More
2C X 1.5 sq.mmCu. Conductor,armoured ,overall shielded Control cable

200

37288

186.44

... More
10C X 1.5 sq.mmCu. Conductor,armoured ,overall shielded Control cable

275

77838

283.05

... More
INSTRUMENT CABLE TRAY

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

30

11669

388.98

... More
200 mm width X 50 mm depth X 1.6 mm thickness

30

16271

542.37

... More
CABLE END TERMINATION AND CONNECTION :

-

-

-

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed copper conductor cable of 1.1kV grade as required.

-

-

-

... More
POWER CABLE

-

-

-

... More
3C x 2.5 sq.mm

6

971

161.86

... More
CONTROL CABLE

-

-

-

... More
2C x 1.5 sq.mm

8

1152

144.07

... More
10C x 1.5 sq.mm

16

4528

283.05

... More
SIGNAL CABLE

-

-

-

... More
1P x 1.5 sq.mm.

14

2016

144.07

... More
ZONAL RESERVOIR (R16) CIVIL WORK

-

-

-

... More
SUB HEAD :- ERARTH WORK

-

-

-

... More
CARRIAGE OF MATERIALS (DSR-1.0/2013)

-

-

-

... More
By Mechanical Transport including loading, unloading and stacking (DSR-1.1/2013)

-

-

-

... More
Earth (10km) (DSR-1.1.2/2013)

58.39

6456

110.58

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areaa (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m diposed earth to be levelled and neatly dressed. (DSR-2.6/2013)

-

-

-

... More
All kinds of soil (DSR-2.6.1/2013)

115.68

6907

59.71

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m. (DSR-2.25/2013)

57.29

2623

45.79

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR-2.27/2013)

331.08

236708

714.96

... More
Clearing grass and removal of the rbbish upto a distance of 50m outside the periphery of the area cleared. (DSR-2.32/2013)

270.4

681

2.52

... More
SUB HEAD-II :- CONCRETE WORKS

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR-4.1/2013)

-

-

-

... More
1:4:8 (1 Cement :4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm (DSR-4.1.8/2013)

10.87

36116

3322.58

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (DSR-4.17/2013)

78.28

25138

321.14

... More
SUB HEAD-III :- REINFORCED CEMENT CONCRETE WORK

-

-

-

... More
Centering and shuttering including including strutting, propping etc. and removal of form for all heights including forming grooves as and whereever requried as per drawing. (DSR-5.9/2013)

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete. (DSR-5.9.1/2013)

100.98

15951

157.97

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR-5.9.2/2013)

-

-

-

... More
Suspended floors, roofs, landings, balconies and access platform (DSR-5.9.3/2013)

365.6

115193

315.08

... More
Shelves (Cast in situ) (DSR-5.9.4/2013)

36.56

11519

315.08

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR-5.9.5/2013)

361.47

94900

262.54

... More
Columns, Pillars, Piers, Abutments, Posts and Struts (DSR-5.9.6/2013)

120.12

43059

358.47

... More
Stairs, (excluding landings) except spiral-staircases (DSR-5.9.7/2013)

16.56

5271

318.35

... More
Edges of slabs and breaks in floors and walls. (DSR-5.9.16/2013)

-

-

-

... More
Under 20cms wide (DSR-5.9.16.1/2013)

53.53

5067

94.66

... More
Cornices and mouldings (DSR-5.9.17/2013)

-

-

-

... More
Weather shade, chajjas, corbels etc. including edges. (DSR-5.9.19/2013)

40.15

15930

396.78

... More
STEEL REINFORCEMENT

-

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR-5.22/2013)

-

-

-

... More
Thermo-Mechanically Treated bars (DSR-5.22.6/2013) (Sail Steel)

2062.13

116221

56.36

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR-5.22A/2013)

-

-

-

... More
Thermo-Mechanically Treated bars (DSR-5.22A.6/2013) (Sail Steel)

26333.6

1484161

56.36

... More
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. (DSR-5.30/2013)

53.53

1263

23.6

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. "(Note :-Cement content considered in this item is @ 330 kg/cum."Excess/less cement used as per design mix is payable/recoverable separately). (DSR-5.33/2013)

-

-

-

... More
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).

-

-

-

... More
All works upto plinth level (DSR-5.33.1/2013)

13.75

66471

4834.28

... More
All works above plinth level upto floor V level (DSR-5.33.2/2013)

175.56

945197

5383.9

... More
Extra for providing richer mixes at all floor levels. (DSR-5.34/2013)

-

-

-

... More
Note :- Excess/less cement over the specified cement content used is payable/recoverable separately.

-

-

-

... More
Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:-Cement content considered inM-30 is @ 340 kg/cum) (DSR-5.34.1/2013)

174.54

9487

54.36

... More
Providing M-40 grade concrete instead of M-25 grade BMC/RMC. (Note :- Cement content considered in M-40 is @ 360 kg/cum) (DSR-5.34.3/2013)

90.26

14725

163.14

... More
SUB HEAD-IV :- BRICK WORK

-

-

-

... More
Brick work with non modular fly ash bricks conforming to IS:12894, class designation10 average compressive strength in super structure above plinth level up to floor V level in : (DSR-6.34/2013)

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.34.2/2013)

234.12

1016647

4342.42

... More
SUB HEAD-VII :- WOOD AND PVC WORK

-

-

-

... More
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, window and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR-9.12/2013)

18

88

4.92

... More
SUB HEAD-VIII :- STEEL WORK

-

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part-1 and M.S. top cover of required thickness for rolling shutters. (DSR-10.6/2013)

-

-

-

... More
80X1.25 mm M.S. laths with 1.25 mm thick top cover (DSR-10.6.1/2013)

48.6

84191

1732.33

... More
Providing and fixing ball bearing for rolling shutters. (DSR-10.7/2013)

12

4440

370.04

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. (DSR-10.8/2013)

-

-

-

... More
Exceeding 10.00 sqm and upto 16.80 sqm in the area. (DSR-10.8.1/2013)

48.6

27409

563.98

... More
Extra for provding grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in-charge (area of grill to be measured). (DSR-10.9/2013)

24.3

6457

265.76

... More
SUB HEAD IX :- FLOORING

-

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR-11.3/2013)

-

-

-

... More
40mm thick with 20mm nominal size stone aggregate. (DSR-11.3.1/2013)

177.5

47653

268.47

... More
Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement :3 coarses sand) finished with a floating coat of neat cement (DSR-11.6/2013)

-

-

-

... More
18 mm thick (DSR-11.6.1/2013)

106

26877

253.56

... More
Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) (DSR-11.26/2013)

-

-

-

... More
25mm thick (DSR-11.26.1/2013)

36.12

32804

908.22

... More
Kota stone slabs 20mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polising complete. (DSR-11.27/2013)

3.61

3367

932.92

... More
Extra for pre finished nosing in treads of steps of Kota stone/sand stone slabs. (DSR-11.31/2013)

37.2

2157

58.01

... More
Extra for kota stone/sand stone in treads of steps and risers using single length up to 1.05 metre. (DSR-11.32/2013)

5.04

65

12.97

... More
Providing and laying vitrified floor tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.41/2013)

-

-

-

... More
Size of Tile 600X 600 mm (DSR-11.41.2/2013)

47.5

56458

1188.6

... More
Providing and laying vitrified tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.46/2013)

-

-

-

... More
Size of Tile 600X 600 mm (DSR-11.46.2/2013)

36.6

43778

1196.14

... More
SUB HEAD- X ROOFING

-

-

-

... More
Providing gola 75X75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (DSR-12.21/2013)

-

-

-

... More
In 75X75 mm deep chase (DSR-12.21.1/2013)

56.69

6146

108.43

... More
Providing and laying roof insulation with 40mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulaton conforming to IS- 12432 Pt. III (density of foam being 40-50 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providng a wearing coursed of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) in chequered rough finish, in panels of 2.5m X 2.5m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. (DSR-12.56/2013)

253.47

245576

968.86

... More
ROOFING SUB HEAD TOTAL

-

-

-

... More
SUB HEAD-XI :- FINISHING WORK

-

-

-

... More
12mm cement plaster of mix : (DSR-13.1/2013)

-

-

-

... More
1:6 (1 cement : 6 fine sand) (DSR-13.1.2/2013)

392.08

44473

113.43

... More
6 mm cement plaster of mix : (DSR-13.16/2013)

-

-

-

... More
1:3 (1 cement : 3 fine sand) (DSR-13.16.1/2013)

365.6

37287

101.99

... More
18 mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) (DSR-13.11/2013)

392.08

71570

182.54

... More
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: (DSR-13.24/2013)

-

-

-

... More
Is one coats (DSR-13.24.1/2013)

117.62

24620

209.32

... More
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR-13.80/2013)

392.08

28374

72.37

... More
Colour washing such as green, blue or buff to give an even shade (DSR-13.39/2013)

-

-

-

... More
New work (two or more coats) with a base coat of white washing with lime (DSR-13.39.1/2013)

392.08

6563

16.74

... More
Finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete. (DSR-13.52/2013)

-

-

-

... More
on steel work (DSR-13.52.1/2013)

40.5

3768

93.05

... More
On concrete work (DSR-13.52.2/2013)

4.05

392

96.86

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour. (DSR-13.81/2013)

-

-

-

... More
Two coats (DSR-13.81.2/2013)

757.68

26806

35.38

... More
SUB HEAD-XII:- SANITARY INSTALLATIONS

-

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vetreous china flushing cistrn & C.P. flush bend with fittings & C.I. brackets, 40mm fluh bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved muninipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: (DSR-17.3/2013)

-

-

-

... More
W.C. pan with ISI marked white solid plastic seat and lid (DSR-17.3.1/2013)

1

3929

3929.03

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430X260X350mm and 340X410X265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting an making good the walls and floors wherever required. (DSR-17.4/2013)

-

-

-

... More
One urinal basin with 5 litre white PVC automatic flushing cistern (DSR-17.4.1/2013)

2

5380

2690.34

... More
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. (DSR-17.7/2013)

-

-

-

... More
White Vitreous China Wash basin size 630X450mm with a pair of 15mm C.P. brass pillar taps (DSR-17.7.1/2013)

1

1842

1842.92

... More
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the receptin of pipes and fittings (DSR-17.8/2013)

1

824

824.11

... More
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete (DSR-17.28/2013)

-

-

-

... More
Flexible pipe (DSR-17.28.2/2013)

-

-

-

... More
32mm dia (DSR-17.28.2.1/2013)

1

61

61.48

... More
Providing and fixing 600X450 mm beveled edge mirror of superrior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete (DSR-17.31/2013)

1

645

645.97

... More
SUB HEAD-XII:- WATER SUPPLY

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (DSR-18.8/2013)

-

-

-

... More
Concealed work, including cutting chases and making good the wall etc.

-

-

-

... More
20 mm nominal outer dia Pipes (DSR-18.8.2/2013)

30

7152

238.43

... More
25 mm nominal outer dia Pipes (DSR-18.8.3/2013)

30

8548

284.96

... More
32 mm nominal outer dia Pipes (DSR-18.8.4/2013)

30

10357

345.25

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of E/I. (DSR-18.9/2013)

-

-

-

... More
100 mm nominal inner dia Pipes (DSR-18.9.9/2013)

30

71782

2392.75

... More
150 mm nominal inner dia Pipes (DSR-18.9.10/2013)

30

86664

2888.81

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931 (DSR-18.49/2013)

-

-

-

... More
15mm nominal bore (DSR-18.49.1/2013)

2

776

388.47

... More
Providing and fixing C.P. brass stop cock (conceale) of standard design and of approved make conforming to IS:8931 (DSR-18.52/2013)

-

-

-

... More
15mm nominal bore (DSR-18.52.1/2013)

2

1048

524.32

... More
SUB HEAD - XIV - DRAINAGE

-

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45X45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mm diameter, 1.8m long complete as per standard design (DSR-19.32/2013)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.32.1/2013)

1

14157

14157.16

... More
Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. (DSR-19.7/2013)

-

-

-

... More
Inside size 90X80 cm and 45 cm deep including C.I. cover with frame (light duty) 455X610mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg.) (DSR-19.7.1/2013)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.7.1.1/2013)

2

13665

6832.8

... More
Extra for depth for manholes: (DSR-19.8/2013)

-

-

-

... More
Size 90X80 cm (DSR-19.8.1/2013)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.8.1.1/2013)

0.15

696

4645.25

... More
SUB HEAD -XV : - ALUMINIUM WORK

-

-

-

... More
Providing and fixing aluminium work for door, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and joined mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/stainless steel screw, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and paneling to be paid for separately) (DSR-21.1/2013)

-

-

-

... More
For fixed portion (DSR-21.1.1/2013)

-

-

-

... More
Powder coated Aluminum (minimum thickness of powder coating 50 micron) (DSR-21.1.1.2/2013)

268.8

84967

316.1

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required (fittings shall be paid for separately) (DSR-21.1.2/2013)

-

-

-

... More
Powder coated Aluminum (minimum thickness of powder coating 50 micron)(DSR-21.1.2.2/2013)

149.76

54268

362.37

... More
Providing and fixing glazing in luminium door, windows, ventilator, shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings an the directions of the E/I (Cost of aluminium snap beading shall be paid in basic item) (DSR-21.3/2013)

-

-

-

... More
With float glass panes of 4.0mm thickness (DSR-21.3.1/2013)

89.86

60160

669.49

... More
With float glass panes of 5.50mm thickness (DSR-21.3.2/2013)

59.9

51219

855.08

... More
Filling the gap in between aluminuim frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of E/I complete (DSR-21.8/2013)

-

-

-

... More
Upto 5mm depth and 5mm width (DSR-21.8.1/2013)

66

4645

70.38

... More
SUB HEAD -XVI-WATER PROOFING WORK

-

-

-

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water profing compound conforming to IS. 2645 and approved by E/I over the RCC slab inclding adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admided with watr proofing compound conforming to IS 2645 and approved by E/I over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand)

-

-

-

... More
admixed with water proofing compound conforming to IS : 2645 and approved by E/I to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) after two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by E/I finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by E/I including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300X300 mm square 3mm deep) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curring and for final test. All above operations to be done in order and as directed and specified by the E/I. (DSR-22.7/2013)

-

-

-

... More
With average thickness of 120mm and minimum thickness at Khurra as 65mm (DSR-22.7.1/2013)

253.47

189587

747.97

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by E/I and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement 3 coarse sand) mixed with water proofing compound confirming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately) Joints saled and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (DSR-22.1/2013)

-

-

-

... More
Using rough kota stone (DSR-22.1.1/2013)

6

4292

715.34

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gap with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement 3 coarse sand) 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all level and as direction by E/I. (DSR-22.2/2013)

-

-

-

... More
Using rough kota stone (DSR-22.2.1/2013)

30

26361

878.73

... More
SUBMERSIBLE PUMP WITH MOTOR

-

-

-

... More
Supply, Erection, testing and commissioning of Submersible pump with CI casing, CF8 M impeller , SS 410 shaft, CI casing wearing ring & bearing bush, TC/ SIC mechanical seal, SS strainer etc suitable for 3 phase, 415 V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class H/F insulation as per specs and IP 68 protection. The pump shall be operated at suitable rpm as per data sheet. The scope includes all required accessories viz. automatic coupling device,G.I guide pipe, chain with shakle, flat/ round submersible cable upto starter panel through suitable size G.I. pipe with necessary electrical connection with the starter panel and as per specifications

-

-

-

... More
Capacity : 500 M³/hr

-

-

-

... More
Head : 42 mtrs.

-

-

-

... More
Motor Rating : 110 KW

5

5893300

1178660.17

... More
VALVES

-

-

-

... More
MOTOR OPERATED SLUICE VALVE

-

-

-

... More
Supply, installation, testing and commissioning of motor operated double flanged, C.I. Sluice Valve

-

-

-

... More
Size : 350 mm NB for Pump Discharge Line

5

1373500

274700

... More
Size : 700 mm NB for Header

1

816917

816917.8

... More
Size : 500 mm NB for Techzone-IV & VILL OHT

1

381527

381527.97

... More
Size : 200 mm NB for Sector- III (C) OHT

1

228019

228019.49

... More
Size : 350 mm NB for Sector-2 & VILL OHT

1

274700

274700

... More
Size : 350 mm NB for Sector-2 & VILL & Sec-3 (R)

1

274700

274700

... More
CHECK VALVE

-

-

-

... More
Cast iron double flanged Single Door Swing Check Valve

-

-

-

... More
Size : 350 mm NB for Pump Discharge Line

5

561072

112214.41

... More
KINETIC AIR VALVE

-

-

-

... More
Supply, Installation, testing & commissioning of C.I. double acting kinetic Air Valve with isolation sluice valve.

-

-

-

... More
Size : 150 mm NB

1

61044

61044.92

... More
MANIFOLD PIPE & PIPE SPECIALS

-

-

-

... More
Supply, Fabrication, laying, testing and commissioning of M.S. pipe & specials with necessary supports & anchoring and including nuts, bolts and hardware

-

-

-

... More
Size : 350 mm NB for Pump Discharge Line

25

100317

4012.71

... More
Size : 700 mm NB for Header

40

438881

10972.03

... More
Supply, Fabrication, Fitting, testing and commissioning of Metallic Expansion Joint with necessary supports & anchoring and including nuts, bolts and hardware

-

-

-

... More
Size : 350 mm NB for Pump Discharge Line

5

215453

43090.68

... More
Supply, Fabrication, laying, testing and commissioning of pipe fittings and specials including Nuts, bolts and hardware

816

62236

76.27

... More
DEWATERING PUMP

-

-

-

... More
Supply, installation, testing & commissioning of non clog submersible dewatering pump to remove sand, silt, clay, sand, pebbles, small rock, algae, shells, plankton, etc. ( with specific gravity of up to 1.1 ) having CI casing, CF8 M impeller , SS 410 shaft, CI casing wearing ring & bearing bush,suitable for 3 phase, 415 V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class H/F insulation as per specs and IP 68 protection. The pump shall be operated at suitable rpm as per data sheet with all required accessories.

-

-

-

... More
Capacity : 50 mtr3/hr.

-

-

-

... More
Head : 10 mtrs.

-

-

-

... More
Motor Rating : 3.7 KW

1

202104

202104.24

... More
E.O.T. CRANE WITH HOIST

-

-

-

... More
Supply, erection, testing and commissioning of fully electrically operated hoist, geared trolley, gantry girder, brake, safety device, locking arrangement, limit switch, pendant push button, starter panel, cables,and other required accessories.

-

-

-

... More
Capacity : 5.0 Ton. For Pump room

-

-

-

... More
Span : 9.5 mtrs.

-

-

-

... More
Lift :10.00 mtrs. (min)

1

845288

845288.14

... More
Supply, erection, testing and commissioning of fully electrically operated hoist, geared trolley, gantry girder, brake, safety device, locking arrangement, limit switch, pendant push button, starter panel, cables,and other required accessories.

-

-

-

... More
Capacity : 2.0 Ton.

-

-

-

... More
Lift :5.00 mtrs. (min)

1

441855

441855.93

... More
CHLORINATION PLANT

-

-

-

... More
Supply, installation, testing & commissioning of vacuum control floor mounted gas chlorinator system including necessary fittings, clamp, copper pipe, ferule filter & control valve with injector with required booster pump, set of diffuser entire associated water & chlorine soulution piping upto diffuser etc, valves,automatic change over ,Chlorine absorption system, saftey & testing kit, etc. complete in all respect as per specs & as per following capacity

-

-

-

... More
Capacity : 2 x 5 kg/hr

1

3161288

3161288.14

... More
Supply, erection, testing and commissioning of single girder electrically operated hoist, geared trolley, brake, safety device, locking arrangement, limit switch, pendant push button, starter panel, cables,and other required accessories.

-

-

-

... More
Capacity : 3.0 Ton.for Chlorination plant

-

-

-

... More
Span : 5.0 mtrs.(max)

-

-

-

... More
Lift :10.00 mtrs. (min)

1

538627

538627.12

... More
900 kg. Chlorine Tonners duly approved by dept. of explosive

2

237288

118644.07

... More
ELECTRICAL WORK

-

-

-

... More
H.T. INDOOR SWITCH GEAR PANEL

-

-

-

... More
Supply, Installation, Testing and Commissioning (SITC) of 11 kV, 350 MVA, 400 A, indoor, drawout type Three HT Vaccuum Circuit Breaker Panel (single breaker) with CT and PT of appropriate rating for metering and protection along with required Indicating lamps, protection relay and Indicating meters, etc. complete in all respects as per IS, Specification.

1

358785

358785.59

... More
H.V. CABLES

-

-

-

... More
Supply, delivery, laying testing & commissioning of 11KV (E), XLPE cable having compacted circular staranded aluminium conductor, conductor screening of extruded semi conducting compound, cross linked polythylane (XLPE), insulation screening of the extruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments) for following mentioned sizes. It should be operational at 11 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on sides and

60

98085

1634.75

... More
top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I. Complete in all respect. The price are inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respects and as per requirement of the job.

-

-

-

... More
(CCI (Bombay/Nashik), Fort Gloster (Calcutta / Baripara), Asian (Thane / Silvasha), Universal (Satna), Nicco (Calcutta), ICL (Rajpura), Diamond, Havells make SOR-3

-

-

-

... More
3CX240 Sqmm.

-

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of 11KV, indoor type cable termination kit of 3 core cable for cable termination at the panel & transformer complete in all respects as required for proper completion of work. (450mm length) SOR-5 (make Raychem/C.C.I./Frontec) d) 3CX240 Sq.mm.

4

36640

9160.17

... More
DISTRIBUTION TRANSFORMER

-

-

-

... More
Supply, delivery, assembly, installation, testing and commissioning of indoor type distribution transformer. 11/0.433 KV, 3 Phase, Double wound winding. Voltage ratio 11000/433- 250 Volts, vector group Dyn 11. Air cooled with manually operated +5% and +10% off load Tap changer and complete with standard fitting & accessories as given in the specification and also confirming to ISS : 2026 with firsh filling of the oil complete as required. (This includes oil testing for dielectric strength, flask over test and filtration of transformer oil to be conducted in the event of unsatisfactory results of oil testing. (Crompton, NGEF, Alstom, BHEL, Voltamp, Diamond, Reychem, Kanohar make) SOR-13 Copper wound (b) 630 KVA

1

888675

888675.42

... More
Supply and levelling of transformer yard using gravel, fine sand and other required filing material, enmarked for the switchyard including removing of trees or boulders if any etc. The general level of the yard shall be at a convenient level for movement of man and material and it should match with FGL.

40

10576

264.41

... More
Supply and Installation of Chain link fencing around switch yard etc. as per Specification.

25

21589

863.56

... More
SITC of 2.5 mtr wide gate with required material as per Specification.

1

8633

8633.9

... More
SITC of Medium Voltage Panel Board

-

-

-

... More
MEDIUM VOLTAGE PANEL BOARD

-

-

-

... More
Panel Board Encloser & Bus-Bar

-

-

-

... More
Supplying, Installation, Testing and Commissioning of Indoor floor mounted totally enclosed, compartmentalized, extendable type PCC / PMCC / MCC Cubicle Panel Board having 36 MVA, 50A breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum 0.8 A/mm2 current density,

-

-

-

... More
extensible type, DMC/SMC busbar supports, suitable for 3 phase-neutral 415 V, 50 HZ AC supply i/c providing and fixing the following switchgears mounted thereon complete with gaskets and interconnections, connections as per specifications complete as required. (The board shall be dust & vermin proof with degree of protection of IP 52 as per IS:12063, free standing type, mounted on base channel of MS Section not less than 100 mm X 50 mm X 5 mm), Isolated cubical compartment for fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.6.8M length X 1M Min.Width X Maximum 2.3M Height with base channel)

-

-

-

... More
800 rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (All bus bars shall be considering Maximum Current Density 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (8.80 Mtr.)

-

-

-

... More
Incoming Section

-

-

-

... More
Incomer Breaker for Transformer (Qty.1 Nos.)

-

-

-

... More
4 Pole ACB - 800A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
3-Phase Digital Type Multifunction Meter (96x96Sqmm.), Accuracy. Class-0.5S (for Active) suitable to measure kVA, kW, kWH, kVAr, kVArH, A,V, P.F. & Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos.)

-

-

-

... More
800/5A, CL 0.5, 15VA for Metering CTs - (3 Nos.)

-

-

-

... More
800/5A, CL.0.5 15VA, CTs for APFC relay - (3 Nos.)

-

-

-

... More
On / Off / Trip / Spring charge LED type Indication Lamp, 220VAC 22.5mm. - (4 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
R,Y,B Led Indication Lamp, 220VAC 22.5mm, - (3 Nos.)

-

-

-

... More
Digital Voltmeter ( 0-500 V) with control fuses. - (1 Nos.)

-

-

-

... More
Digital Ammeter ( 0-800 A) with control fuses. - (1 Nos.)

-

-

-

... More
Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.)

-

-

-

... More
DG Incomer Breaker D.G (Qty.1 No.)

-

-

-

... More
4 Pole ACB - 800A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
800/5A, CL 0.5, 15VA, Metering CTs - (3 Nos.)

-

-

-

... More
On / Off / Trip / Spring charge LED type Indication Lamp, 220VAC 22.5mm. - (4 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (3 Nos.)

-

-

-

... More
R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.)

-

-

-

... More
Digital Voltmeter ( 0-500V) with control fuses. - (1 Nos.)

-

-

-

... More
Digital Ammeter ( 0-800A) with control fuses. - (1 Nos.)

-

-

-

... More
Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.)

-

-

-

... More
Transformer No-load losses comp. Fixed Capacitors for Tran. (Qty.1 Nos.)

-

-

-

... More
63A 3P MCB, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
25 kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Timer for Capacitor - (1 Nos.)

-

-

-

... More
R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.)

-

-

-

... More
On LED type Indication Lamp, 220VAC 22.5mm. - (1 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
32A MCB for Capacitor - (1 Nos.)

-

-

-

... More
20A MCB for Capacitor - (1 Nos.)

-

-

-

... More
4A MCB for Capacitor - (1 Nos.)

-

-

-

... More
15 kVAR APP. Type Capacitor - (1 Nos.)

-

-

-

... More
8 kVAR APP. Type Capacitor - (1 Nos.)

-

-

-

... More
2 kVAR APP. Type Capacitor - (1 Nos.)

-

-

-

... More
Outgoing Section

-

-

-

... More
210A Soft-Starter for 132kW (Suitable for 110kW Moto after derating) Feeder Each Comprising of following: (Qty. 5 Sets.)

-

-

-

... More
350A TP MCCB, 36 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.)

-

-

-

... More
325A Three Pole AC-3 duty line Contactor- (1 Nos.)

-

-

-

... More
630A Semiconductor (FA) Bussmann fuse type 170M5012 & Fuse Holder-170H3004 - (3 Nos.)

-

-

-

... More
210A Soft-Starter for 132kW (Suitable for 110kW Moto after derating) - (1 Nos.)

-

-

-

... More
325A Three Pole AC-3 duty By Pass Contactor of Soft Starter - (1 Nos.)

-

-

-

... More
350/5A, CL 0.5, Metering CTs - (3 Nos.)

-

-

-

... More
On / Off / Trip LED type Indication Lamp, 220VAC 22.5mm. - (3 Nos.)

-

-

-

... More
Stat Push Button - (1 Nos.)

-

-

-

... More
Stop Push Button - (1 Nos.)

-

-

-

... More
Digital Ammeter ( 0-350A) with control fuses. - (1 Nos.)

-

-

-

... More
Selectro Switch (Ammeter) - (1 Nos.)

-

-

-

... More
Selectro Switch (Auto/Manual, Local/remote) - (2 Nos.)

-

-

-

... More
Pump Protection Unit - (1 Nos.)

-

-

-

... More
(MPR + SPP) with CBCT - (1 Nos.)

-

-

-

... More
2.5A TP MPCB with Thermostate and 2 nos. Cooling fan (CFM- 105) for Starter Enclosure etc. - (1 Lot)

-

-

-

... More
APFC Panel feeder (For 160 kVAR APFC Panel) - (Qty. 1 No.)

-

-

-

... More
315 A TPN MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.)

-

-

-

... More
On / Off LED type Indication Lamp, 220VAC 22.5mm. - (2 Nos.)

-

-

-

... More
63 A (415V) TPN 'C' Curve MCB Feeders - (2 Nos.)

-

-

-

... More
32 A (415V) TPN 'C' Curve MCB Feeders - (10 Nos.)

-

-

-

... More
Power Feeders

-

-

-

... More
32 TPN MCB Feeders for Incomer - (1 Nos.)

-

-

-

... More
On / Off LED type Indication Lamp, 220VAC 22.5mm for (a) Incommer - (2 Nos.)

-

-

-

... More
6A TPN 'C' Curve MCB - (6 Nos.)

-

-

-

... More
Miscellaneous accessories

-

-

-

... More
Terminals, Jumper wires, Control wiring, HRC fuse link with Control Fuse, Space heater, Control Transformer, Illumination lamp and all other required Panel Miscellaneous accessories etc.. - (1 Lot)

-

-

-

... More
i) Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables. ii) Provide terminals for Trip interlock for future use. ( Spare shall be supplied with short link) - (1 Lot)

-

-

-

... More
Note: i) Auto/Manual and Local / Remote selector switches shall be provided for all starters which shall operate through PLC when selected in Auto Mode. In manual mode the drive shall operate through manually through MCC-PB or through LCS-PB. When Local / Remote switch is selected in local mode or remote mode respectively. Potential free contacts shall be provided to monitor drive status signals (A/M switch status, drive On/Off status and drive trip status) at PLC. ii) Low level switch for dry run protection pumps shall be interlocked at respective starters through provision of required relays and relay based logic for pumps tripping at ICP.

1

3209041

3209041.53

... More
APFC PANEL BOARD (160 kVAR - 8 STEP)

-

-

-

... More
Panel Board Encloser & Bus-Bar

-

-

-

... More
Supplying, Installation, Testing and Commissioning of Indoor floor mounted totally enclosed, compartmentalized type APFC Cubicle Panel Board having 36 MVA breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum 0.8 A/mm2 current density, extensible type, DMC/SMC

-

-

-

... More
busbar supports, suitable for 3 phase- neutral 415 V, 50 HZ AC supply I/c providing and fixing the following switchgears & capacitors mounted there on complete with gaskets and interconnections, connections as per specifications complete as required. (The APFC Panel board shall be dust & vermin proof with degree of protection of IP 42 as per IS:12063, free standing type, mounted on base channel of MS Section not less than 100 mm X 50 mm X 5 mm) and as per IS, Specification (Mini.1.2M length X Min. 750M Width X Maximum 2M Height with base channel)

-

-

-

... More
315A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (All bus bars shall be considering Maximum Current Density 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (2 Mtr.)

-

-

-

... More
Incoming Section

-

-

-

... More
Incomer Breaker for APFC (Qty. 1 No.)

-

-

-

... More
315A 3P+N MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. For On / Off /Trip - (3 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm For R, Y, B - (3 Nos.)

-

-

-

... More
HRC Control fuses with fuse base (6A) for voltmeter, Ameter, APFC relay - (9 Nos.)

-

-

-

... More
Digital Voltmeter (0-500V) - (1 Nos.)

-

-

-

... More
200/5A, CL-1, 15VA, Metering CTs - (3 Nos.)

-

-

-

... More
Digital Ammeter (0-315A) - (1 Nos.)

-

-

-

... More
Selectro Switch (For Auto / Manual) - (1 Nos.)

-

-

-

... More
APFC Relay

-

-

-

... More
8-Step Microprocessor Based APFC Relay - (1 Nos.)

-

-

-

... More
Outgoing Section

-

-

-

... More
30kVAR Capacitors feeders each Comprising of following: (Qty. 3 Set.)

-

-

-

... More
63A 3P MCB for Capacitor - (1 Nos.)

-

-

-

... More
30kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.)

-

-

-

... More
30kVAR Double layer APP Type Capacitor - (1 Nos.)

-

-

-

... More
20kVAR Capacitors feeders each Comprising of following: (Qty. 2 Set.)

-

-

-

... More
40A 3P MCB for Capacitor - (1 Nos.)

-

-

-

... More
20kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.)

-

-

-

... More
20kVAR Double layer APP Type Capacitor - (1 Nos.)

-

-

-

... More
15kVAR Capacitors feeders, Qty. 1 No.

-

-

-

... More
32A 3P MCB for Capacitor - (1 Nos.)

-

-

-

... More
15kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.)

-

-

-

... More
15kVAR Double layer APP Type Capacitor - (1 Nos.)

-

-

-

... More
10kVAR Capacitors feeders, Qty. 1 No.

-

-

-

... More
32A 3P MCB for Capacitor - (1 Nos.)

-

-

-

... More
10kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.)

-

-

-

... More
10kVAR Double layer APP Type Capacitor - (1 Nos.)

-

-

-

... More
5kVAR Capacitors feeders, Qty. 1 No.

-

-

-

... More
16A 3P MCB for Capacitor - (1 Nos.)

-

-

-

... More
5kVAR Capacitor Duty Contactor - (1 Nos.)

-

-

-

... More
Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.)

-

-

-

... More
5kVAR Double layer APP. Type Capacitor - (1 Nos.)

-

-

-

... More
Miscellaneous APFC Panel Accessories

-

-

-

... More
Terminals, Jumper wires, Control wiring, HRC fuse link with Control Fuse, Space heater, Control Transformer, Illumination lamp and all other required Panel Miscellaneous accessories etc.. - (1 Lot)

-

-

-

... More
Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables. - (1 Lot)

-

-

-

... More
Note: Auto/Manual selector switches shall be provided for Auto/Manual mode of opearation to operate APFC Panel through APFC Relay when selected in Auto Mode & in manualy when selected Manual mode. - (1 Lot)

1

286792

286792.37

... More
LDB / PDB / JB / LCS

-

-

-

... More
SITC of Lighting Distribution Board as under: Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Single door

1

3488

3488.98

... More
Incoming Section

-

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

1

1803

1803.39

... More
Outgoing Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

24

2969

123.73

... More
SITC of Outdoor Lighting Distribution Board as under: Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/recess complete with loose wire box of sheet steel, dust protected,duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way Double door

1

8969

8969.49

... More
Incoming Section

-

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

1

1563

1563.56

... More
32A Contactor

1

1588

1588.98

... More
Time switch.

1

1697

1697.46

... More
Outgoing Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral

8

5315

664.41

... More
SITC of Power Distribution Board as under: Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s,terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way Single door

1

10844

10844.92

... More
Incoming Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral

1

664

664.41

... More
Outgoing Section

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

12

6203

516.95

... More
SITC of stand / wall mounting Junction Box with Protection Class of IP-65, fault level-25kA with steel structure stand etc. for Termination of 1.1 kV Submersible Flexible Copper Power & Control cable with (A) One run 3C x 185 sq.mm A2XFY power cable.

5

25809

5161.86

... More
SITC of stand / wall mounting Junction Box with Protection Class of IP-65, fault level-25kA with steel structure stand etc. for Termination of 1.1 kV Submersible Flexible Copper Power and / or Control cable with (A) 5C x 2.5/1.5 sq.mm ywy control cable.

5

19525

3905.08

... More
SITC of Pendant type ON_OFF pushbutton set complete with Enclouser, necessary mounting/ fixing arrangement on wall / pipe support etc. to be installed near motors for remote operation, etc. as per IS and specifications

5

13016

2603.39

... More
MEDIUM VOLTAGE CABLES

-

-

-

... More
Supply & laying of aluminum conductor PVC insulated armoured served sheathed cables 1100 Volts grate at a depth of below ground level over a cushion of 75 mm. below ground level over a cushion of 75 mm. thick sand all round and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer – in charge, complete in all respected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.

-

-

-

... More
300sq. mm. 3-1/2 core

285

488606

1714.41

... More
185sq. mm. 3-1/2 core

300

339408

1131.36

... More
150sq. mm. 3-1/2 core

50

46907

938.14

... More
6 sq.mm. 4 core

200

41356

206.78

... More
4 sq.mm. 3 core

100

18220

182.2

... More
SITC of 1.1 kV, YWY / PVC insulated (IS 1554) Cu conductor cables as per specification & IS.

-

-

-

... More
3C x 2.5 sq. mm. YWY Cable

690

107005

155.08

... More
4C x 2.5 sq. mm. YWY Cable

1060

199428

188.14

... More
5C x 1.5 sq.mm. YWY Cable

300

48051

160.17

... More
10C x 1.5 sq.mm. YWY Cable

70

19695

281.36

... More
CABLE END TERMINATION AND CONNECTION:

-

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required.

-

-

-

... More
3½ X 300 sq. mm (70mm)

18

14338

796.61

... More
3½ X 185 sq. mm (57mm)

10

5686

568.64

... More
3½ X 150 sq. mm (50mm)

4

1698

424.58

... More
Supply & fixing of brass nickel plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects .The armoured of the cable shall be properly connected with the earth as per direction of Engineer – in charge.

-

-

-

... More
6sq.mm. 4 core

8

400

50

... More
4sq.mm. 3 core

2

79

39.83

... More
Supply & fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of Engineer – in charge.

-

-

-

... More
6sq.mm.

32

325

10.17

... More
4sq.mm.

6

61

10.17

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed copper conductor cable of 1.1kV grade as required.

-

-

-

... More
3C x 2.5 sq. mm. YWY Cable

18

3066

170.34

... More
4C x 2.5 sq. mm. YWY Cable

38

6472

170.34

... More
5C x 1.5 sq.mm. YWY Cable

10

1466

146.61

... More
10C x 1.5 sq.mm. YWY Cable

4

996

249.15

... More
CABLE TRAY

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

50

48220

964.41

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

45

32071

712.71

... More
150 mm width X 50 mm depth X 1.6 mm thickness

50

22161

443.22

... More
EARTHING

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

14

106055

7575.42

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

10

31805

3180.51

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

115

148038

1287.29

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

125

10911

87.29

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

100

2881

28.81

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

100

11525

115.25

... More
50 x 6 GI strips

200

37628

188.14

... More
INTERNAL WIRING

-

-

-

... More
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

51

31421

616.1

... More
Supply and wiring of submain with four no. 2.5 sq.mm. FR PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2mm thick) PVC conduit with two no. 1.5 sq.mm. FR PVC insulated 1100 V grade multistrand copper conductor as earth continuity wire drawn inside the conduit.

250

37077

148.31

... More
Wiring for Circuit / Submain wiring along with earth wire with the (2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire) sizes of FRLS insulated copper conductor, Single core cable in Surface / recessed medium class PVC Conduit as required.

165

19575

118.64

... More
Supply and fixing of 25 mm sizes of medium Class PVC Conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

165

10068

61.02

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

2

1325

662.71

... More
Supply and fixing of following size / modules, GI Box along with modular base & cover plate for modular switches in recess etc. as required. (For 15/16A and 5A/6A Switch & Socket)

-

-

-

... More
(a) 8 Module (125mm x 125mm)

15

3444

229.66

... More
(b) 3 Module (100mm x 75mm)

13

1894

145.76

... More
Supply and fixing of following Modular Switch / Socket on the modular plate & Switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
6 pin 15/16 Amp Socket outlet

28

3867

138.14

... More
15/16 Amp Switch

28

2705

96.61

... More
3 pin 5/6 Amp Socket outlet

15

1283

85.59

... More
5/6 Amp Switch

15

978

65.25

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

674

674.85

... More
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (Pump house & Panel room)

3

5481

1827.12

... More
Supplying and fixing TP sheet steel enclosure on surface/recess along with 16/25/32amps 415 volts “C” curve TP MCB complete with connections, testing and commissioning etc. as required. (For Ele. Hoist etc.)

3

2161

720.34

... More
INTERNAL LIGHT FIXTURES

-

-

-

... More
Supply and fixing of factory wired HPF industrial type fluorescent tube light fitting with vitreous enameled reflector suitable for 2X40 w fluorescent tube including tubes etc. on surface complete in all respects. Cat AA (seg.)

23

31868

1385.59

... More
Supply and fixing of factory wired, surface type mirror optic fittings made of pre anodized aluminium section with P2 / P5 louvers suitable for & with 2no.36 w CFL complete in all respect. Cat AA

2

9911

4955.93

... More
Supply and fixing of factory wired asymmetrical beamed integral flood light luminaires with die cast aluminium housing & A1 .reflector having built in control gear unit duly pre wired plate complete with ballast, ignitor ,capacitor for 1*150 w M.H. with lamp complete in all respect. Cat AA

4

19681

4920.34

... More
Supply and fixing of industrial bulk head fitting with polycarbonate base guard, prismatic reflector silicon gasket suitable for and with 1X18 w CFL complete in all respect. Cat A

2

1203

601.69

... More
380mm sweep 1400 R.P.M exhaust fan, capacitor type, having double ball bearing, M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC supply conforming to IS: 2312.Fan shall be painted with epoxy grey colour controlled by one 6 A flush type switch on board and 6A plug point near Ex. fan.

7

14836

2119.49

... More
1200mm sweep ceiling fan, capacitor type, having double ball bearing 450mm down rod, canopies, shackle, rubber bush, blades, electronic speed regulator, suitable to operate on 230V,50Hz AC supply conforming to IS: 374/1979.Fan shall be painted with white colour.

3

3775

1258.47

... More
EXTERNAL LIGHT FIXTURES

-

-

-

... More
Supply and fixing of factory wired asymmetrical beamed integral flood light luminaires with die cast aluminium housing & A1 .reflector having built in control gear unit duly pre wired plate complete with ballast, ignitor ,capacitor for 1*150W M.H. with lamp complete in all respect. Cat AA

8

36881

4610.17

... More
Supply & erection of Steel tubular single wing pole with 30cm around & 1/6 over all length of pole grouted with cement concrete in 1:3:6 (1 cement : 3 coarse sand : 6 stone ballast) including plinthing of pole & 15cm around & 30 cm above the ground level, plastering of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. required for proper completion of work as per direction of E/I. SOR-20 a) 410 SP-17, 8.5mtr., 92kg.

6

44745

7457.63

... More
Supply and fixing of factory wired sodium vapour lamp street light luminaries single piece cast “Aluminium” body suitable for 70w S.V. lamp including integral control gear, 70w S.V. lamp on G.I. pipe bracket complete in all respects on on pole.

6

21203

3533.9

... More
Supply and fixing of H.P.M.V. post top lantern, suitable for 80w M.V. lamp complete with control gear pole mounting box and 80 w M.V. lamps etc. complete in all respects. Cat AA (seg.)

2

5108

2554.24

... More
DIESEL GENERATOR WITH AMF PANEL SET

-

-

-

... More
SITC OF DIESEL GENERATOR WITH ENGINE, ALTERNATOR & DG CONTROLLER SET

-

-

-

... More
SITC of 500 KVA DG set or higher rating (as required to run complete working load of pumping station including lighting.) 415 V,50 Hz,3 Phase, 4 wire Diesel Generator (Engine, Alternator & DG Controller) Set. Diesel engine shall be complete with necessary controls and safety devices confirming to relevent ISS/BSS with latest amendements. Diesel Engine shall be suitable for continuous operation of generator set duty inclusive of fly wheel, air cleaner, radiator.fan with guard,fuel pump,fuel filter,Electronic governor,electrical starting system with starter,12 V battery, voltage regulator,instrument panel, Exhaust silencer, protections against low lubrication oil pressure,high water temperature.

-

-

-

... More
Alternator shall be 415V, 3 phase, 50 Hz, 4 wire, 0.8 power factor, self excited,self regulated,brushless type,drip proof confirming to IS:4722 with latest amendments. DG set shall comply latest emission norms of Ministry of Environment & Forest (MOEF) by Government of India, effective from July 2014. DG set engine shall be manufactured as per present CPCB norms. DG set rating shall be for prime rating power (PRP) in accordance with BS 5514 / IS / ISO. DG set shall meet all statutory / pollution control regulation requirement with all currently applicable statutory norms, regulations and safety codes of the latest applicable Indian Standards.

-

-

-

... More
The engine and alternator shall be coupled over a sturdy common base frame. Day fuel tank with necessary fuel to hoses the engine fule and complete in all respect as required. DG set shall be along with acoustic enclosure / canopy and suitable for outdoor mounting.

-

-

-

... More
SITC OF AMF PANEL

-

-

-

... More
Panel Board Encloser & Bus-Bar

-

-

-

... More
Supplying, Installation, Testing and Commissioning of Indoor floor mounted totally enclosed, compartmentalized, extendable type AMF Panel Board having 36 MVA, 50 kA breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with electrolytic grade high conductivity PVC sleeved aluminium (E91

-

-

-

... More
E) busbars, DMC/SMC busbar supports, suitable for 3 phase- neutral 415V, 50 HZ AC supply i/c providing and fixing the following switchgears mounted thereon complete with gaskets and interconnections, connections as per specifications complete as required. (The board shall be dust & vermin proof with degree of protection of IP 52 as per IS:12063, free standing type, mounted on base channel of MS Section not less than 100 mm X

-

-

-

... More
50 mm X 5 mm), Isolated cubical compartment for fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.0.8M length X 0.75M Min.Width X Maximum 2.3M Height with base channel)

-

-

-

... More
800A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (All bus bars shall be considering Maximum Current Density 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (1.50 Mtr.)

-

-

-

... More
DG Incomer Breaker, (Qty. 1 Set)

-

-

-

... More
4Pole ACB - 800A, 50 kA, with Micro Processor based releases (Overload, Short Circuit and earth fault protetive release) etc. - (1 Set)

-

-

-

... More
3-Phase Digital Type Multifunction Meter (96x96Sqmm.), Accuracy Class-1, suitable to measure A,V, P.F. & Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos.)

-

-

-

... More
3-Phase Digital Type Trivector / Energy Meter, Accuracy Class- 0.5S (For Active), suitable to measure kVA, kW, kWH, kVAr, kVArH, P.F. & Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos.)

-

-

-

... More
800/5A, Core-1 CL 0.5, 15VA for Metering - (3 Nos.)

-

-

-

... More
Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
Digital Voltmeter (0-500V) with control fuses. - (1 Nos.)

-

-

-

... More
Digital Ammeter (0-800A) with control fuses. - (1 Nos.)

-

-

-

... More
LED type Indication Lamp, 220VAC 22.5mm for On / Off / Trip / Spring charge - (4 Nos.)

-

-

-

... More
LED Indication Lamp, 220VAC 22.5mm for R,Y,B - (3 Nos.)

-

-

-

... More
LED Indication Lamp, 220VAC 22.5mm for Load ON, Control ON, Breaker ON & OFF - (4 Nos.)

-

-

-

... More
Push Button for Engine Start & Stop, Emergency Stop, ACB Trip & Closed, Hooter Accept - (6 Nos.)

-

-

-

... More
Selectro Switch for Ammeter, Voltmeter, Control Supply On&Off, Auto-Manual mode, Local-Rermote (PLC) mode. - (5 Nos.)

-

-

-

... More
Automatic Mains Failure (AMF) Digital Relay - (1 Nos.)

-

-

-

... More
Line Voltage Monitoring digital Relay - (1 Nos.)

-

-

-

... More
Fully Automatic Battery Charger - (1 Nos.)

-

-

-

... More
Digital type DC Voltmeter (0-50V) - (1 Nos.)

-

-

-

... More
Digital type DC Ammeter (0-10A) - (1 Nos.)

-

-

-

... More
DC Control HRC fuses with fuse base (6A) - (6 Nos.)

-

-

-

... More
DC Selectro Switch (For Battery Charger On&Off) - (1 Nos.)

-

-

-

... More
Miscellaneous accessories

-

-

-

... More
Terminals, Jumper wires, Control wiring, HRC fuse link with Control Fuse, MCBs, Auxiliary Realys, Auxiliary Contactors, Space heaters, Control transformer, Illumination lamps and all other required Panel Miscellaneous accessories etc. - (1 Lot)

-

-

-

... More
Provide minimum 4 Nos. or 20% spare terminals which ever is higher for control cables. - (1 Lot)

-

-

-

... More
Note: Auto-Manual selector switch and Local-Remote (PLC) selector switch shall be provided for each AMF Panel, when selected in Auto mode, the panel shall operate through AMF relay & in manual mode, the Panel shall operate through manually, in manual mode through local-remote selector switch, in local mode panel shall operate through Panel Push-Button and in remote mode, panel shall operate through PLC.

1

4147428

4147428.81

... More
SAFETY ACCESSORIES

-

-

-

... More
Supply and fixing of fire extinguisher, dry chemical type 5.00 kg. Capacity (ISI mark) completes with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

5

16042

3208.47

... More
Providing and fixing H.T. danger notice plate of 250mmX200mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

371

123.73

... More
Providing and fixing M.V. danger notice plate of 200mmX150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

450

112.71

... More
Supply and fixing of shock treatment chart(prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.

2

345

172.88

... More
Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in- charge.

5

1135

227.12

... More
Supply and layfing of 1800mmX900mmX12mm thick chequered rubber matting of tested quality.

13

24336

1872.03

... More
Supply and fixing of 20 W fluorescent lamp operated emergency light with maintenance free battery for 3 hours opeation during mains power failure.

3

5827

1942.37

... More
First Aid box.

2

449

224.58

... More
11 kV Rubber Hand Gloves

2

422

211.02

... More
STRUCTURE STEEL

-

-

-

... More
Supply & Installation of Structure Steel required for support structure of equipments, LCS, cable, cable tray & earthing etc. for support on floor / wall / beam / brackets etc. including required welding/ cutting/ grinding shall be done to complete the job.

750

54660

72.88

... More
INSTRUMENT WORK

-

-

-

... More
PRESSURE MEASURMENT SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning of

-

-

-

... More
Pressure transmitter with indicator & all accessories

-

-

-

... More
at delivery of each Pump and common header.

-

-

-

... More
Range : 0 - 10 kg / sq.cm.

6

379586

63264.41

... More
PRESSURE GUAGE

-

-

-

... More
Supply, installation, testing & commissioning of

-

-

-

... More
Bourdan pressure guage having 150 mm dial with

-

-

-

... More
necessary S.S.cock at delivery line of each Pump.

-

-

-

... More
Range : 0 - 10 kg / sq.cm.

5

16453

3290.68

... More
PRESSURE SWITCH

-

-

-

... More
Supply, installation, testing & commissioning of

-

-

-

... More
Pressure switch at delivery line of each Pump.

-

-

-

... More
Range : 0 - 10 kg / sq.cm.(Adjustable type)

5

33665

6733.05

... More
FLOW MEASURING SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of

-

-

-

... More
Electromagnetic type flow meter with indiactor, transmitter and totaliser with all accessories and,

-

-

-

... More
hardwares, etc.complete in all respects.

-

-

-

... More
Size : 500 for manifold size 700 mm of R16 Header

1

369239

369239.83

... More
LEVEL MEASURING SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning

-

-

-

... More
Ultrasonic type Level transmitter with indicator and all

-

-

-

... More
required accessories & hardwares, etc. complete in

-

-

-

... More
all respects.

-

-

-

... More
Range : 0 - 6 Mtrs. Supply, installation, testing & commissioning of Float

1

114502

114502.54

... More
& Board type level indicator with all accessories.

-

-

-

... More
Range : 0 - 6 Mtrs. Supply, installation, testing & commissioning of Float

1

18852

18852.54

... More
type level switch with all accessories for Dry run

-

-

-

... More
protection of pumps. Range : 0 - 10 Mtrs.

1

5418

5418.64

... More
FRC ANALYZER Supply, installation, testing & commissioning of Amperometric type Free Chlorine Analyzer complete with transmitter, sensor, sensor cable, Sensor mounting assembly , accessories, hardware,consumables, etc. complete in all respects. Measuring Range : 0 - 5 mg/L

1

315699

315699.15

... More
PLC / SCADA FOR CONTROL ROOM

-

-

-

... More
Supply, installation, testing and commissioning of PLC-SCADA system including Instrument control Panel, PC based HMI along with 19" colour LCD Screen, Required programming / SCADA/Application Software, A3 Size Laser Printer, GSM-GPRS / Broadband based communication for Remote Data Transmission, Min. 1 kVA UPS (with 30 min backup alongwith suitable rating SMF batteries & battery charger and all other accessories as per standard), etc. complete in all respects and as per specifications. PLC shall have I/O count of 60 DI / 24 DO / 12 AI / 0AO.

1

847838

847838.98

... More
INSTRUMENT CABLES

-

-

-

... More
Supply, laying, testing and commissioning of Instrument Cables including termination & Trays

-

-

-

... More
3C X 2.5 sq.mm YWY Power cable

225

47859

212.71

... More
1P X 1.5 sq.mm Cu. Conductor,armoured ,overall & individual shieldedSignal cable

700

132286

188.98

... More
2C X 1.5 sq.mmCu. Conductor,armoured ,overall shielded Control cable

450

83898

186.44

... More
10C X 1.5 sq.mmCu. Conductor,armoured ,overall shielded Control cable

450

127372

283.05

... More
INSTRUMENT CABLE TRAY

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

30

11669

388.98

... More
200 mm width X 50 mm depth X 1.6 mm thickness

40

21694

542.37

... More
CABLE END TERMINATION AND CONNECTION :

-

-

-

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed copper conductor cable of 1.1kV grade as required.

-

-

-

... More
POWER CABLE

-

-

-

... More
3C x 2.5 sq.mm

6

971

161.86

... More
CONTROL CABLE

-

-

-

... More
2C x 1.5 sq.mm

12

1728

144.07

... More
10C x 1.5 sq.mm

24

6793

283.05

... More
SIGNAL CABLE

-

-

-

... More
1P x 1.5 sq.mm.

18

3401

188.98

... More
GIS MAPPING AND APPLICATION DEVELOPMENT FOR WATER SUPPLYSYSTEM

-

-

-

... More
Procurement of Geo eye1 (90 days archive), standard 0.5 mt. resolution, multispectral 8 band, Color, satellite image

225

943857

4194.92

... More
Create and develop new vector map (1:1000 scale). Identify the gaps in Land base Data from Satellite Image and arrange/capture the missing (gap) Land base features from the field etc. Including digitization of geometry (line, point and polygon) of the Land base features.

225

1321398

5872.88

... More
Capture position on ground using DGPS with required accuracy for all land base features including features like road, divider, drainage, Bridge, Canal, Landmark, Railway Track, over ground utilities, Electric HT line etc. verification of all digitised features with real ground and create GDB (Geo- Database) using GIS

225

1321398

5872.88

... More
Capture (set geometry to the correct geographic position in the existing data/map) all water supply pipeline network and associated line i.e. Transmission mains, Distribution main, Service line, valve chamber, scour valve, air valve, major pipe junctions etc. (all details required for hydraulic modelling ) positions on ground using DGPS with the desired accuracy. Integration of spatial and non-spatial data, create GDB (Geo- Database) using GIS and Schema compatible Creating grid of TBM with triangulation with minimum observation of 2 hrs for main TBM grid and using final results of post processing software output.

190

3188135

16779.66

... More
Carryout filed survey for latest position of all civil structures related to water supply system i.e. intake structure, water treatment plant, water distribution station, pumping station, over head tank, under ground tank using DGPS with required accuracy, Integration of spatial and nonspatial data, create GDB (Geo-Database) using GIS.

250

1468220

5872.88

... More
Digitise drawing available with client or create as built drawing of civil, electrical, mechanical works for intake structure, water treatment plant, water distribution station, pumping station etc. and create GDB (geo database) using GIS.

150

2516949

16779.66

... More
Capturing location of all water meter using DGPS with required accuracy , create GDB (Geo- Database) using GIS (for revenue modelling)

1500

6292380

4194.92

... More
Application Development of water distribution management system for water supply (Schema) on GIS platform (OGC compliance) and integration with SCADA system scope cover integration from staring point to end user point (i.e. from intake point to distribution centre, flow meter/water meter)

225

1887711

8389.83

... More
Supply of software Arc 10.2, Arc facility manager and required supporting hardware (server)

1

4614406

4614406.78

... More
Labour Cess will be paid extra as per applicable

-

-

-

... More
GST will be paid extra as per applicable

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.