Gorakhpur Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Gorakhpur Industrial Development Authority Tender
Electrical and Electronics
Eprocure
Opening Date16 Mar 2024
Closing Date22 Mar 2024
Tender Amount₹ 3,56,22,443
Costs
EMD
₹ 19,81,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UGIDA_918302_1Bid Award Id
ViewTender No
5672/ABHI.NI-6/GIDA/2023-24 DT. 15.03.2024Tender Authority
Gorakhpur Industrial Development Authority ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
S/o Aluminium Tape. CD-2019, A-20
12
4332
361
S/o Grouting of poles. uppcl.
12
10656
888
S/o Plinth of Poles. uppcl.
12
12120
1010
S/o MS Top Channel 125x65mmx2240 mm Long.CD 2021-22 A-4
12
10980
915
S/o MS Top Channel Clamp with nut bolt uppcl. CD2021-22 A-2
24
5112
213
S/o Dropper Chaneel 100x50x2600 mm.CD 2021-22 A-4 .
24
19752
823
S/o Dropper angle Clamp. uppcl.
48
5136
107
S/o Earth wire clamp. uppcl.
12
1488
124
S/F Aluminium bainding wire.(6mm dia.) C.D 2021-22 A-1/10
200
45200
226
S/o Nut bolt & washar. CD 2021-22 A-7
90
19440
216
Stay set complete (Stay rod 16x1800mm, Stay wire 5kg,Stay clamp, bolt and with grouting)
16
35680
2230
Danger board & barwed wire icluding jamper CD2021-22 A-4(1)
32
54464
1702
S/o 11 KV XLPE Cable 3x300 sq.mm SIR 2023-24 Sl No.12
5200
7763600
1493
S/o 11 KV Jointing kit (3x300 sqm.) outdoor SIR 2023-24 Sl.84
24
148248
6177
S/o Straight throught (3x300 sqm.) SIR 2023-24 Sl.84
5
54245
10849
S/o HDPE PIPES PE-80 PN-10 DN size 160 mm dia/ in 6mtr lenth. CD-2019 A-12A
2783
5215342
1874
S/F of brass nickle plated comperssion gland for PVC insulated & armoured served shealthed underground cable including rubber ring etc. complete in all respect. The amouring of the cable shall be properly connected with the earth as per direction of as per E/I. PS No. 503 (O) (o)120 sq.mm 3.5 core
96
23328
243
S/o LT XLPE Cable AL. 3.5X150 sqm. SIR 2023-24 Sl. 02
4500
2961000
658
Laying of 3x300 sq mm cable. Dublle Circuit layer CD 2021-22 A-10
4827
1206750
250
Laying of 3.5x150 sq mm cable. Dublle circuit layer CD 2021-22 A-10
4010
1002500
250
Earthing for feeder pilar Lt Main & outgoing panel.uppwd PS .725 A
30
193500
6450
Root marker DSR- 22- 7.9
10
5850
585
Supply, delivery, assembly, installation, testing and commissioning of 630 KVA. Copper wound Outdoor type distribution transformer. 11/0.433 KV, 3 Phase Double wound winding. Voltage ratio 11000/433-250 Volts, vector group Dyn 11. Air cooled with manually operated +5% and +10% off load Tap changer and complete with standard fitting & accessories as given in the specification and also confirming to IS: 1180 with first filling of the oil complete as required. (This includes oil testing transformer oil to be conducted in the event of unsatisfactory results of oil testing. (ABC, Crompton, Servokon, Kirlosker,schiender make) complete in all respect.as per the directions of the Engineer-in-charge. SIR 2023-24 Sl No-74
4
5849560
1462390
Plinth of Transformer for above 04 Nos. (Size- per plinth=3x3x1.5 cub.mtr). A-29, CD-2019
54
293112
5428
S/of Fencing of Transforme. (Size 4x4x2 cub.mtr.) CD-2019 A-29
128
370048
2891
S/F 11 KV H.T. feeder box. 2021-22 A-1
2
130000
65000
Grouting for above 11 KV H.T. feeder box.CD-2021-22 A-1
8
7536
942
S/o 11 KV TPMO Switch with fitting clamp. SIR 2023-24 Sl 92
4
30288
7572
S/o11 KV D.O.Fuse set with fixing clamps. 2023-24 Sl 93
4
13856
3464
Cartage and eraction charge @15% on item no 1 to 32
1
3866291
3866291.85
W/o Tranchless road Crosing and Cable ducking by HDD mathod 3 mtr below the ground suface (Duble Circuit.).As per rate noida authority.
600
3608400
6014
Supply, delivery, erection, testing & commissioning of cubicle type out-door weather proof main Feeder Pillar made of 3mm MS sheet of size 1500X1000X600mm water tight, dust & vermin proof with hinged door & locking arrangement on front & rear side, 2 nos locks, incoming & outgoing fuse carriers, cable entry, earthing strip, incorporating the following technical specifications with complete power coating: Single line diagram on main feeder pillar is to be painted showing feeding arrangement. (a) Incoming 1 No. - 400 Amp. SFU with HRC fuse links (b) Bus-bar 500V, 400Amp., TPN aluminium with insulation paint. Size 50X8 mm. (c) Outgoing 10 Nos. 150A TPN, 415V HRC fuse carriers with HRC fuse links (EE/GE, Siemens/L&T/C&S make.) As per drawing of feeder pillar enclosed. & The feeder pillar will be mounted on cement concrete foundation 1.24 (1) cement 2 coarsand graded stone aggregate 20 mm nominal size) of suitable size. The feeder will be manufactured by C.P.R.I approved as per E/I YEIDA AOR.
24
2372472
98853
Total (GST@18% Already included
-
35622442
-
Evaluation Notes How It Works ?