Gorakhpur Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Gorakhpur Development Authority - GDA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date24 Jun 2023
Closing Date7 Jul 2023
Tender Amount₹ 5,19,15,484 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
from 1.5 to 3m depth (S.I.No-254)

583.69

79382

136

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.h (DSR-2.25)

1838.66

413201

224.73

... More
Plain Cement Concrete Work

-

-

-

... More
Concrete with 4.00cm (1½") gauge approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of materials, labour T&P etc. required for the proper completion of the work. (S.I.NO-281)

99.55

541054

5435

... More
Reinforced Cement Concrete Work

-

-

-

... More
All RCC work for foundation, pedestals & beams RCC upto plinth Lvl. (D.S.R. No-5.1.2)

474.62

3513113

7401.95

... More
All RCC work for column & wall RCC above plinth Lvl. (S.O.R. No-288)

29.18

261452

8960

... More
All RCC work for plinth beam , roof beam & slab etc. (D.S.R. No-5.3)

13.04

123698

9486.11

... More
Formwork

-

-

-

... More
Centering & shuttering work for foundation (D.S.R. No-5.9.1)

522.22

142315

272.52

... More
Centering & shuttering work for pedestal /column & wall (D.S.R. No-5.9.2)

915.21

542280

592.52

... More
Centering & shuttering work for plinth beam , roof beam & slab etc. (D.S.R. No-5.9.5)

1279.96

689079

538.36

... More
Reinforcement Steel

-

-

-

... More
Reinforcement steel for foundation raft/footing , pedestal /column & wall, beams , slab etc. (DSR-5.22.6)

62287.08

4941857

79.34

... More
Structural Steel

-

-

-

... More
Structural steel for columns, beams & truss sheds etc. (D.S.R. No-10.2)

95460.77

9457298

99.07

... More
Roof covering sheet (D.S.R. No-12.1.1)

1600.5

1870106

1168.45

... More
Wall covering sheet (D.S.R. No-12.1.1)

994.97

1162572

1168.45

... More
Masonary work

-

-

-

... More
In foundations upto plinth Lvl.

-

-

-

... More
for 115 thk. Brick work

-

-

-

... More
for 230 thk. Brick work (S.I.No-303)

364.13

1585786

4355

... More
In Superstructre above plinth Lvl.

-

-

-

... More
for 115 thk. Brick work (D.S.R. No-6.13.1)

139

128310

923.1

... More
for 230 thk. Brick work (D.S.R. No-6.3.1)

557.71

3963494

7106.73

... More
Plaster work

-

-

-

... More
All internal Plaster (DSR-13.4.1)

1732

470930

271.9

... More
All External Plaster (DSR-13.12)

3051.54

1247225

408.72

... More
Painting work

-

-

-

... More
for wall internal walls (DSR-13.41.1)

1732

249148

143.85

... More
For external wall (DSR-13.45.1)

3051.54

661604

216.81

... More
Flooring work

-

-

-

... More
For Rifle shooting & karate/ dance hall (DSR-11.4))

569.18

431142

757.48

... More
For badminton court

531.19

1363230

2566.37

... More
Providing and injecting chemical emulsion for preconstructional Anti Termite treatment. Rates as per quotation.

531.19

109796

206.7

... More
Providing and fixing Mapple wood flooring 21 mm thick etc completed, rates as per quotation.

531.19

2998301

5644.5

... More
Providing and fixing Net and pole movable etc completed, rates as per quotation.

8

190800

23850

... More
Providing laying and fixing YONEX Court mat AC 364 etc completed, rates as per quotation.

4

2035200

508800

... More
Providing and laying jogging track/running track 15 mm thick sytnthetic rubberized flooring and finishing the surface…

360

1436400

3990

... More
Providing and laying 13 mm thick running track system as per "IAAF World Atheletics standards " as per quatation…

360

1616400

4490

... More
For Admin block (DSR-11.41.4)

146.28

330352

2258.36

... More
For Toilet block (DSR-11.41.3)

60.16

75420

1253.67

... More
Ceiling work

-

-

-

... More
For Admin block

156.61

249467

1592.92

... More
For Toilet block

69.07

110022

1592.92

... More
Miscellaneous Items

-

-

-

... More
Doors & windows

-

-

-

... More
Entrance door for (1.8m X 2.4m)

1

25000

25000

... More
Rolling shutter Door (3.00m X2.5m X 2 nos)

15

112500

7500

... More
W1 (1.2m X 1.5m)

2

14000

7000

1

7000

7000

4

28000

7000

... More
V (0.6m X 0.75m)

12

54000

4500

2

9000

4500

... More
D (1.2m X 2.4m)

3

48000

16000

... More
D1 (1.05m X 2.4m)

9

126000

14000

... More
D2 (0.9m X 2.1m)

2

24000

12000

... More
SANITARY FIXTURES

-

-

-

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.(D.S.R. No-17.78)

13

149978

11536.77

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (D.S.R. No-17.22A)

11

8627

784.29

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (Kitchen sink with drain board) (D.S.R. No-17.10)

-

-

-

... More
510x1040 mm bowl depth 250 mm (D.S.R. No-17.10.1.1)

1

5317

5317.21

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe (D.S.R. No-17.28)

-

-

-

... More
32 mm dia (D.S.R. No-17.28.2.1)

1

92

92.35

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points etc. of approved quality conforming to 15 MM Nominal Bore (IS:8931) (D.S.R. No-18.53)

53

23467

442.79

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (D.S.R. No-12.44)

56

2373

42.39

... More
WATER SUPPLY SYSTEM (INTERNAL & EXTERNAL)

-

-

-

... More
Providing and fixing G.I. pipes (Medium B class) complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall (For pipe exposed in ceiling shafts/terraces only)

-

-

-

... More
32 mm dia nominal bore

40

19950

498.76

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
15 mm nominal outer dia Pipes

40

15616

390.4

... More
20 mm nominal outer dia Pipes

60

27279

454.65

... More
25 mm nominal outer dia Pipes

100

55403

554.03

... More
SANITARY FIXTURES

-

-

-

... More
Providing and fixing Health Faucet assembly of approved make, ABS body with 1.2 m long SS flexible hose and wall hook etc. complete in all respects.

13

12051

927

... More
Providing and fixing of vitreous china white below counter oval /circular wash basin with CP brass waste assembly, wall flanges, Braided flexible pipe and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required complete in all respects..

-

-

-

... More
Wash basin with a 15 mm CP Brass single hole/lever basin mixer

11

59169

5379

... More
Providing and fixing C.P. brass sink mixer of approved make with single lever swivel spout table mount complete including cutting and making good the walls wherever required.

1

4433

4433

... More
Providing and fixing Stainless Steel (SS304) Convertible Ring Gratingof approved make & design with grating embedding and setting ring into the floor with cement mortar, complete in all respects. Round 127 mm (for drain pipe 100 mm)

25

13950

558

... More
SOIL, WASTE, VENT AND RAIN WATER PIPES & FITTINGS

-

-

-

... More
Providing, fixing, testing and commissioning of SWR TYPE -B Soil, Waste and Vent Pipes confirming to IS:13592-1992 along with all required fittings e.g. bends, junctions, cowls, offsets, reducers, access pieces,clamps etc. confirming to IS 14735, with or without access doors, jointing with approved solvent cement as per manufacturer recommendation, including cutting, fixing of pipe to wall/sunken floor/ceiling with clamps, chasing of brick/RCC structure and making good the same wherever required complete in all respects as per specifiction and direction of Engineer In Charge.

-

-

-

... More
110 mm outer dia

140

110740

791

... More
Providing , fixing,testing and commissioning of uPVC 6kg/cm2 pipe to IS:4985:2000 complete with all required fittings, clamps, jointing etc. including cutting, fixing of pipe to wall, ceiling/sunken floor etc. for Waste pipes, bath wastes, overflow, kitchen equipment waste connections and condensate drainage including cutting of brick/RCC wall wherever required and making good the same as, complete in all respect as per specifiction and direction of Engineer In Charge.

-

-

-

... More
40 mm outer dia

16

5872

367

... More
63 mm outer dia

40

20240

506

... More
Providing, fixing, jointing and testing of uPVC rain water pipes conforming to IS 4985 class III (6 kg/cm²) including injection moulded fittings like bends, tees, adopters etc. suitable for rubber ring jointing complete including jointing with rubber ring as per manufacturer recommendation and fixing to walls with clamps complete in all respects as per specifiction and direction of Engineer in Charge.

-

-

-

... More
110mm outer Dia

24

18024

751

... More
Providing & fixinguPVC Multi Floor Trap of self cleansing design with or without vent arm with provision for connecting pvc inlet fitting complete including cost of cutting and making good the walls and floors wherever required, complete as per direction of Engineer in Charge.110x75x50

16

3408

213

... More
Providing and fixing uPVC Floor Drain consisting of 110x63mm I elbow (grating and pipe to be paid separately), complete as per direction of Engineer in Charge.

9

1233

137

... More
Providing and fixing Nickle Bronze Clean Out plug(FCO & COP) with suitable insert keys for opening, male threaded joint with socket complete in all respects.100mm dia

8

8432

1054

... More
WATER SUPPLY SYSTEM (INTERNAL & EXTERNAL)

-

-

-

... More
Providing and fixing G.I. pipes (Medium B class) complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall (For pipe exposed in ceiling shafts/terraces only)

-

-

-

... More
80 mm dia nominal bore

170

285940

1682

... More
100 mm dia nominal bore

180

410580

2281

... More
Providing and fixing forged brass lever operated ball valve of approved make, full flow with forged brass ball (with hard chrome plated), PTFE Gland Packing and Seating, Test Pressure (Hydrostatic) :

-

-

-

... More
25mm dia

2

1880

940

... More
32mm dia

12

18108

1509

... More
WATER SUPPLY SYSTEM

-

-

-

... More
Providing and fixing G.I. pipes (Medium Class) complete with G.I. fittings including trenching and refilling etc. (External work) (D.S.R. No-18.12)

-

-

-

... More
20 mm dia nominal bore (D.S.R. No-18.12.2)

30

8372

279.07

... More
25 mm dia nominal bore (D.S.R. No-18.12.3)

40

14794

369.87

... More
32 mm dia nominal bore (D.S.R. No-18.12.4)

150

60687

404.58

... More
50 mm dia nominal bore (D.S.R. No-18.12.6)

100

57894

578.94

... More
Painting G.I. pipes and fittings with two coats of anti-corrosive

-

-

-

... More
bitumastic paint of approved quality :

-

-

-

... More
20 mm dia nominal bore

30

318

10.62

... More
25 mm dia nominal bore

40

540

13.5

... More
32 mm dia nominal bore

150

2442

16.28

... More
50 mm dia nominal bore

100

2235

22.35

... More
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :

-

-

-

... More
20 mm dia nominal bore

30

4243

141.46

... More
25 mm dia nominal bore

40

5808

145.22

... More
32 mm dia nominal bore

150

22347

148.98

... More
50 mm dia nominal bore

200

31310

156.55

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall (For pipe exposed in ceiling shafts/terraces only)

-

-

-

... More
25 mm dia nominal bore

15

6520

434.69

... More
40 mm dia nominal bore

10

6417

641.73

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore

2

1340

670

... More
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 20 mm nominal bore

2

615

307.88

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (D.S.R.18.33)

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (D.S.R.18.33.1)

6

53641

8940.27

... More
SEWERAGE & DRAINAGE

-

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : In all kind of soils

-

-

-

... More
Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia

350

129269

369.34

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (D.S.R. No-19.6)

-

-

-

... More
150 mm dia (D.S.R. No-19.6.2)

50

21818

436.37

... More
250 mm dia (D.S.R. No-19.6.3)

400

287132

717.83

... More
300 mm dia (D.S.R. No-19.6.4)

200

159654

798.27

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of RCC pipes including bed concrete as per standard design

-

-

-

... More
150 mm dia

50

30520

610.4

... More
250 mm dia

400

334124

835.31

... More
300 mm dia

200

192762

963.81

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

6

13454

2242.48

... More
Constructing brick masonry road gully chamber / Catch basin 50x45x60 cm (average depth 60 cm) with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

30

148392

4946.42

... More
Constructing brick masonry chamber for underground C.I. inspection chamber/ Manhole and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

3

19402

6467.39

... More
Extra for depth beyond 45 cm of brick masonry chamber :

-

-

-

... More
For 500x700 mm size

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

10899

5449.6

... More
Extra for depth for manholes :

-

-

-

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand),inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :

-

-

-

... More
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

10

105189

10518.98

... More
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

12366

6183.01

... More
including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter

4

2420

605.04

... More
RAIN WATER HARVESTING PIT

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. (All kinds of soil)

354

64360

181.81

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

296

66520

224.73

... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil

120

11097

92.48

... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

8

44786

5598.27

... More
Centering and shuttering including strutting, propping etc. and removalof form for

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete.

19

5177

272.52

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

11

6517

592.52

... More
Suspended floors, roofs, landings, balconies and access platform

15

10175

678.36

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

11

5921

538.36

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.

494

39193

79.34

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum

4

30739

7684.78

... More
Providing and laying Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:

-

-

-

... More
Cement mortar 1:4 (1 cement : 4 coarse sand)

61

371506

6090.27

... More
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)

171

54673

319.73

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:

-

-

-

... More
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.

-

-

-

... More
(b) Laying brick bats with mortar using broken bricks/brick bat 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.

-

-

-

... More
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.

-

-

-

... More
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.

-

-

-

... More
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :

-

-

-

... More
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

15

20216

1347.74

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia

114

59729

523.94

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia

38

32012

842.43

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200mm nominal size dia

76

73932

972.79

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

8

9219

1152.48

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

8

9267

1158.41

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.

8

9267

1158.41

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

4

5236

1309.07

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring rojections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after

-

-

-

... More
fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

118

50865

431.06

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. H D - 20 Circular shape 560 mm internal diameter

4

5289

1322.3

... More
WATER SUPPLY SYSTEM

-

-

-

... More
Providing and Fixing HDPE Pipes (PE-100 grade) IS: 4984 of 10 Kg / cm2 including all fittings bends, junctions, tee, end cap etc. jointing as per manufacturer's instructions including trenching, refilling & testing of joints complete as per directions of the engineer-in-charge.( For IRRIGATION SYSTEM )

-

-

-

... More
25mm dia

50

10700

214

... More
32mm dia

10

2470

247

... More
40mm dia

100

29300

293

... More
50mm dia

100

36400

364

... More
Providing and fixing forged brass lever operated ball valve of approved make, full flow with forged brass ball (with hard chrome plated), PTFE Gland Packing and Seating, complete in all respect.

-

-

-

... More
25mm dia

15

14100

940

... More
50mm dia

2

6110

3055

... More
WATER SUPPLY PUMPS, EQUIPMENT & WATER TREATMENT UNIT

-

-

-

... More
Raw Water Pump

-

-

-

... More
Providing and fixing horizontal/ vertical monobloc pumping set with CI stage casing and SS-304 impellers with stainless steel SS-304 shaft with mechanical seal as per IEC standards and GJL250 cast iron suction & discharge casing connected to a TEFC induction motor suitable for 400/440 volts, 3 phase 50 cycles A.C. supply with suction/delivery header with valves/ NRV/Strainer/Flanges/Blank Flanges/Nuts bolts/Washers/gasket (matching with puddle flange of tanks/ pumps)/vibration elimination pads etc. including 150 mm dia pressure gauge gunmetal isolation cock, vibration eliminating pads under foundations all mounted on a c common base plate of 80x40 mm section bolted to cement concrete foundations complete with base and frame,nuts,bolts,washer and necessary RCC foundation as per requirement and each pump shall have following duty.

-

-

-

... More
No. of Pumps : 2 (1 Working + 1 Stand by ) Capacity : 200 lpm per pump (each) Head : 30m

1

175000

175000

... More
Pressure Filter (Domestic Water)

-

-

-

... More
Supply, Installation, Testing & Commissioning of Vertical self supporting dual media filter fabricated comprising 300 mm bed depth of graded sand gravel and 600 mm of bed depth of antracite and minimum 900 mm pre board, fabricated from high performance M.S. plate of minimum 10 mm thick for shell 12mm thick of dish end. Heaving perforated bed plate (14mm thick) collection system complete MS sheet as per IS: 2825, pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete.

-

-

-

... More
Each Filter

-

-

-

... More
Discharge : 10000 lph

-

-

-

... More
Filtration Rate : 16000 lit./m2/h

-

-

-

... More
Suggested dia app. : 0.9 m

1

155000

155000

... More
Vertical, inline multistage centrifugal pumping set with stainless steel SS-304 stage casing and SS-304 impellers with stainless steel SS-316L shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply No. of Pumps: 2 (1 Working + 1 Stand by)

-

-

-

... More
Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles. No. and capacity of Pressure Vessel – 1 Nos. x 200Ltrs

-

-

-

... More
Control Panel with programmable logic controller (PLC) for cyclic operation of pumps. Pump working sequence should change after every operation. Contractor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter. Control panel should also consist of cooling fan.

-

-

-

... More
Pressure switches bellow type fitted with micro switch and having maximum pressure and differential scale should confirming BS-6134 standards and IP55 protection class.

-

-

-

... More
Ball valves to be used should be Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement.

-

-

-

... More
Complete set including all necessary suction and delivery valves and accessories, including mild steel flanges with 3 mm thick rubber insertion, nuts, bolts and washers, Pot / Y Strainer on suction side as required, with the system to be mounted on a common base frame, and RCC foundations as per requirement. The following shall be the working duty.

-

-

-

... More
Capacity : app. 250 LPM

-

-

-

... More
Head : app. 50 M

1

225000

225000

... More
Providing and fixing automatic chemical dozing system consisting of electronic dosing pump with all accessories, suitable to doze chemical solution upto 1 ppm doze (of Sodium Hypo-chloride solution) to a filtered water flow of 10,000 lph. against a pressure of 50-60 psi complete with FRP moulded solution holding tank of min. 200 litre with all standard accessories.

1

85000

85000

... More
Providing and fixing compact monoblock dry motor submersible pumps for suitable rating, with non-clog free flow open impeller, minimum solid handling capacity of 46mm suitable for operation on 415 volts + 5% -15%, 50 C/s A.C three phase supply, speed 960/1440R&M including oil chamber, guide wire for lifting & lowering of pump, M.S. galvanized lifting chain, duck foot bend with following specifications:

-

-

-

... More
The above pump sets must be supplied complete with following accessories.

-

-

-

... More
(a) Complete piping 100mm dia delivery header upto termination of outside nearest catch basin as per enclosed tentative layout. (The pipe should be preferably CI LA/heavy duty G.I) -- 1 Set

-

-

-

... More
(b) 80mm dia Butterfly valve.-- 2 Nos

-

-

-

... More
(c) 80 mm dia reflux valve.-- 2 Nos

-

-

-

... More
(d) Necessary cables from pump set to starter panel (position of panel is near by sump).-- 1 Set

-

-

-

... More
(e) Electrical switch panel having all necessary accessories & safety devices of standard specifications. (Panels with sump pumps near each sump as per site conditions). --1 No.

-

-

-

... More
(f) Automatic built-up water level controller with necessary length of cable upto control/starter panel.

-

-

-

... More
(g) Arrangement of alternate switching mechanism for operational and standby pumps.

-

-

-

... More
(h) Arrangement of simultaneous start of both the pump at predetermined level with the indication of water level controller.

-

-

-

... More
For Pump room Drainage

-

-

-

... More
Discharge - max. 25 Cu.m/hr. (Each)

-

-

-

... More
Total head - 15 m

-

-

-

... More
(Complete set as above with 2 nos. pumps)

1

65000

65000

... More
ELECTRICAL SYSTEM

-

-

-

... More
Two (2) Nos. Auto Star Delta Starter for 15 HP motor. Each shall have Auto/ Manual selector switch, over load relay, single phasing preventor, ON/OFF/ Trip indication lamps, ON/OFF push Buttons, contactor and suitable No. of Potential free contacts for remote / local operations, indication & interlocking.(For Borewell Pumps)

-

-

-

... More
Spare N.O. - N.C. contacts for each starter - 3Set.

-

-

-

... More
G.I. strip 25 x 6 mm throughout the length of MCC.

-

-

-

... More
All internal wiring with colour coding from incoming mains to various switchgear, starter, meter, indicating lamp and bus bar.

-

-

-

... More
All starters shall be compatible for remote operation.All Switch gears offered must be compatible with the H.P. of the motors offered

-

-

-

... More
Automatic chemical doser of 1 No of aprox 0.2 to 1HP capacity interlocking with raw water pumps.

-

-

-

... More
Panel to be made according to actual rates of pumps/Nos of pump/Actual requirement.

-

-

-

... More
All MCB shall be motor duty (c curve) type & shall have minimum 10KA breaking capacity.

-

-

-

... More
(The shop drawing to be prepared and approved before fabrication)

1

125000

125000

... More
Supply, installation, testing and commissioning of motor pump controller cum water level indicating panel suitable for outdoor installation made out of 2mm thick CRCA sheet with epoxy coating including the following:

-

-

-

... More
Electronic water level controller working on magnetic type sensing probes.

-

-

-

... More
Electronic minimum 5-level Digital indicator with magnetic type sensing probes.

-

-

-

... More
Arrangement of alternate switching mechanism for operational and standby pumps.

-

-

-

... More
Water Level Indicators - Minimum 5 level Multi level Digital indicators with magnetic type sensor probes complete as per following details:-

-

-

-

... More
Note: The location of indication for domestic OHT in WTP area and for flushing OHT in STP area)

-

-

-

... More
Underground tanks

-

-

-

... More
(a) Raw Water Tanks

1

15000

15000

... More
(b) Domestic Water Tanks

1

15000

15000

... More
(c) Overhead Water Tanks (Domestic)

1

15000

15000

... More
Water Level Controllers - With electronic sensing probe complete in all respect as per the following details & functions. Tubewell Pumps (2W)

-

-

-

... More
To start at low level in R.W tanks, and to cut off at high level in raw water tanks. (Incl. High pressure trip, extra low level alarm & extra high level alarm). Raw Water Pumps (1 W + 1 S)

1

18000

18000

... More
To cut off at low level in raw water U.G tanks and to cut off at high level in U.G domestic water tanks. (Incl. High pressure trip, extra low level alarm & extra high level alarm). Domestic Water Pumps (1 W + 1 S)

1

18000

18000

... More
To cut off at low level in Domestic water U.G tanks and to cut off at specific high pressure in delivery line to over head tanks. (Incl. High pressure trip, extra low level alarm & extra high level alarm). Domestic Water Pumps (2 W + 1 S)

1

18000

18000

... More
Providing and fixing motorised butterfly/globe valve normally operated type suitable for 240V with working pressure rating of not less than 10 kg/cm2, with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessry cables, conduites etc complete.Rates include to make a provision with by pass arrangement for installing of motorised valve at over head tank level for inlet connection (Two nos. of union to be provided) for domestic & Flushing. 25 mm dia.

2

20000

10000

... More
Supply, installation, testing and commissioning of heavy duty copper armored cable 1.1KV grade including necessary support clamp at ceiling or excavation upto rquired depth & filling the same in trench. Protection cable covering 150mm alaround by sand and brick, jointing of existing cable of bore by weather proof junction box or any other arrangement as per site conditions.(From UGT to OHT)

-

-

-

... More
control cable 4 core 1.5 Sq.mm

50

2000

40

... More
G.I. earthing wire 8 gauge from all motor and M.C.C panel to be connected in as approved manner to the general earthing system complete.

25

1000

40

... More
Supply and laying of the following earthing strip clamped to walls / with cable tray with suitable clamps saddles and fixing bolts / in ground including the cost of digging and back filling complete as required with IS: 3043 : 1987

-

-

-

... More
25 mm x 3 mm G.I. Strip

50

7500

150

... More
FIRE PUMP & EQUIPMENT

-

-

-

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (Code No.4)

-

-

-

... More
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520

-

-

-

... More
b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.

-

-

-

... More
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
900 lpm at 35 m Head

1

75478

75478.76

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. (Code No.20)

1

15937

15937.17

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

1

1334

1334.51

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.

-

-

-

... More
100 mm dia

1

5707

5707.96

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia (Code No.7)

135

258930

1918

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required

-

-

-

... More
25 mm dia

8

3334

416.81

... More
50 mm dia

15

10446

696.46

... More
80 mm dia

3

2978

992.92

... More
100 mm dia

42

55715

1326.55

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.

-

-

-

... More
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585

-

-

-

... More
20 mm nominal internal dia gun metal globe valve & nozzle.

-

-

-

... More
Drum and brackets for fixing the equipmets on wall.

-

-

-

... More
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m

3

22335

7445.13

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

3

15894

5298.23

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)

6

23543

3923.89

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)

3

4375

1458.41

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with Matching flanges, nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
80 mm dia

3

12854

4284.96

... More
100 mm dia

5

28557

5711.5

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with Matching flanges,rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
100 mm dia

1

9589

9589.38

... More
Providing and fixing in position the industrial type pressure gauges (Dial Size: 100mm,/150mm.with gun metal / brass valves,with suitable range complete as required

4

3872

968.14

... More
Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

4

34090

8522.7

... More
FIRE HYDRANT SYSTEM

-

-

-

... More
Providing & Fixing of standard Fireman's Axe with heavy insulated handle.

3

1428

476

... More
Providing & Fixing of weather proof standard Fire hose cabinet (900 mm x 600 mm x 300 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner. (For Internal hydrant system)

3

28854

9618

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body,squeeze lever discharge valve fitted with internal discharge tube, ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge with CO2 gas conforming to IS : 307-1996.

-

-

-

... More
Capacity 4.5 kg. I.S.I. Marked. (IS : 15683 : 2006)

6

37056

6176

... More
Providing and fixing ABC stored pressure dry chemical powder (mono ammonium phosphate) Fire Extinguisher IS : 15683 latest revision manufacturer and of CRCA sheet in welded construction, finish with High quality epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzle, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases).

-

-

-

... More
Capacity 6 Kg (IS : 15683 : 2006)

2

4340

2170

... More
Providing and fixing water Co2(ISI marked) extinguishers including all accessories as per IS specification with wall bracket with rawl plug

-

-

-

... More
Capacity 9 LTR. I.S.I. Marked. (IS : 15683 : 2006)

6

16026

2671

... More
ELECTRIC CONTROL PANEL FOR TERRACE PUMP

-

-

-

... More
Supply, installation, testing and commissioning of Control Panel having suitable rating DOL starters for Terrace Fire Pumps (1W+1S) as per technical specification of the following capacity and should have auto operation interlock with the pumps.

-

-

-

... More
Control Panel for Terrace Fire Pump (On Terrace)

1

41728

41728

... More
Supply, installation, testing and commissioning of DOL starters for Terrace Fire Pumps as per technical specification of the following capacity suitable for manual operation of pumps from ground floor.

-

-

-

... More
DOL Starter for Terrace Fire Pump (12.0 KW) (On Ground Floor)

1

8397

8397

... More
Supply, installation, testing and commissioning of following size of cable

-

-

-

... More
4 core 16 Sq mm XLPE (Aluminum Armoured cables for power cabling)

100

23130

231.3

... More
2 core 4 Sq mm XLPE (Aluminum un Armoured cables for control cabling)

100

5470

54.7

... More
Electrical Work:

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
12 way, Double door(D.S.R. No-2.3.3)

5

10243

2048.67

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) (D.S.R. No-2.4)

-

-

-

... More
6 way Double door (D.S.R. No-2.4.2)

6

26410

4401.77

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (D.S.R. No-2.12)

-

-

-

... More
40 amps (D.S.R. No-2.12.1)

5

1880

376.11

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(D.S.R. No-2.13)

-

-

-

... More
63 amps (D.S.R. No-2.13.2)

6

5490

915.04

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(D.S.R. No-2.10)

-

-

-

... More
Single pole (D.S.R. No-2.10.1)

90

20389

226.55

... More
Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required. (D.S.R. No-2.14)

-

-

-

... More
63 amps (D.S.R. No-2.14.3)

18

43359

2408.85

... More
40amps (D.S.R. No-2.14.2)

1

2338

2338.05

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.

-

-

-

... More
Group – C

75

97367

1298.23

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group – C

40

30371

759.29

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

650

134023

206.19

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

200

48672

243.36

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

150

44337

295.58

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

-

-

-

... More
2 X 10 sq. mm + 1 X 6 sq. mm earth wire

100

50442

504.42

... More
2 X 16 sq. mm + 1 X 6 sq. mm earth wire

-

-

-

... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

50

18141

362.83

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

100

66726

667.26

... More
4 x 10 sq.mm + 2 x 6 sq.mm. earth wire

250

222345

889.38

... More
4 x 16 sq.mm + 2 x 6 sq.mm. earth wire

-

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in residential buildings).

40

16884

422.12

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

15

7778

518.58

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

7

10041

1434.51

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton

1240

366519

295.58

... More
SUB-HEAD III - FANS & LIGHT FIXTURES:

-

-

-

... More
Supply, Installation, Testing & Commissioning of recess mounted round LED luminaire 9 watt, made of die cast aluminium alloy body having white powder coating with high Translucent Frosted PS/PMMA diffuser for homogeneous light distribution. Fixture should have minimum efficacy at System level (Not Chip Level) ≥110 lumens/watt and a minimum system lumen output of 900lumens

35

30886

882.48

... More
Supply, Installation, Testing & Commissioning of recess mounted round LED luminaire 18 watt, made of die cast aluminium alloy body having white powder coating with high Translucent Frosted PS/PMMA diffuser for homogeneous light distribution. Fixture should have minimum efficacy at System level (Not Chip Level) ≥110 lumens/watt and a minimum system lumen output of 1800lumens

50

96034

1920.68

... More
Supply, Installation, Testing & Commissioning of recess mounted round LED luminaire 36 watt,(2'x2') made of die cast aluminium alloy body having white powder coating with high Translucent Frosted PS/PMMA diffuser for homogeneous light distribution. Fixture should have minimum efficacy at System level (Not Chip Level) ≥110 lumens/watt and a minimum system lumen output of 3600lumens

30

98110

3270.35

... More
Supply, Installation, Testing & Commissioning of 300mm sweep dia Exhaust fan

6

10278

1713.04

... More
MAIN PANEL OUTDOOR TYPE

-

-

-

... More
INCOMER (From 100KVA Transformer)

-

-

-

... More
1 No. 200amps 4P MCCB(16KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.

-

-

-

... More
One Nos. 315A 4P contactor

-

-

-

... More
METERING & INDICATION for each Incomer

-

-

-

... More
1 set of R,Y,B phase indicating lamps

-

-

-

... More
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port.

-

-

-

... More
Sets of 315/5A, CL-1, 15VA CTs for measuring.

-

-

-

... More
Sets of phase indicating lamp with 2A control MCBs.

-

-

-

... More
Master trip relay separately, ALSTOM make

-

-

-

... More
Trip circuit supervision relay separately, ALSTOM make

-

-

-

... More
INCOMER (From 62.5KVA D.G)

-

-

-

... More
1 No. 125amps 4P MCCB(16KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications.

-

-

-

... More
One Nos. 200A 4P contactor

-

-

-

... More
AMF PANEL INCLUDED

-

-

-

... More
METERING & INDICATION for each Incomer

-

-

-

... More
1 set of R,Y,B phase indicating lamps

-

-

-

... More
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port.

-

-

-

... More
Sets of 315/5A, CL-1, 15VA CTs for measuring.

-

-

-

... More
Sets of phase indicating lamp with 2A control MCBs.

-

-

-

... More
Master trip relay separately, ALSTOM make

-

-

-

... More
Trip circuit supervision relay separately, ALSTOM make

-

-

-

... More
The panel shall be SCADA compatible, which means vendor has to consider necessary hardware (that is FRTU with power supply unit & accessories) for communication of Circuit breakers, protection relay and Multi-function meter through interfacing signals, and serial communication and these feedbacks should be duly wired at FRTU.

-

-

-

... More
The FRTU shall be installed within the panel itself along with a dual SIM 4G router, MAESTRO/TELTONIKA make

-

-

-

... More
FPI with SCADA contacts to be considered at incomer

-

-

-

... More
BUS-BAR

-

-

-

... More
400A TPN Aluminium Bus Bar with colour coded PVC Sleeves

-

-

-

... More
OUTGOINGS

-

-

-

... More
1 No. 100 amps 4P MCCB(21KA)

-

-

-

... More
5 No. 63 amps 4P MCCB(10KA)

-

-

-

... More
8 No. 63 amps 4P MCB(10KA)

-

-

-

... More
5 No. 40 amps 4P MCB(10KA)

-

-

-

... More
as described above fully auto on off main Panel

-

-

-

... More
MAIN PANEL as described above

1

789729

789729.29



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.