Gliders India Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Gliders India Limited Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date30 Jan 2024
Closing DateCancelled
Tender Amount₹ 71,99,201
Costs
EMD
₹ 1,32,990Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GIL_183638_1Tender No
OPF/TE/EO(CW)/ IR/15/2023-24Tender Authority
Gliders India Limited ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT of Rewiring/ Modernization /Modification of Lab area at OPF Kanpur
Tender Documents of Rewiring/ Modernization /Modification of Lab area at OPF Kanpur
BOQ Items
Taking down cement plaster on brick wall of any description including raking out joints, hacking for key, scrubbing down with water etc.
100
-
-
Taking down existing wall panelling/false ceiling and similar work
520
-
-
(M&L ) Door closer Aluminium Die cast Body, hydraulically regulated designation No. 3 Universal type.
4
-
-
S/F 15 mm Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required. , heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge
35
-
-
(M&L) Brick work with sub class ‘B’ bricks straight or curved on plan exc. 6m mean radius with 1:6 cement mortar or as directed by EIC/SIC.
4.5
-
-
(M&L) cement concrete(1:2:4 ,40mm graded aggregated ) in surface channels and drains and mass concrete or as directed by EIC/SIC.
31.5
-
-
(M&L) RCC in column, pillars, posts and struts
3.5
-
-
(M&L)Mild steel bars 10mm dia and over, cut to length, bent to shap required, including rings, cranking bending spirally for hooping for columns,hooking ends and binding with and including milding steel wire or as per directive of EIC/SIC.
280
-
-
Anodised aluminium snap grid frame work for false ceiling all as specified
425
-
-
M&L 6mm thick Gypsum board ceiling both side laminated self imposed texture boards fixed to a snap grid made out of anodised aluminium T-sections (size of grid 605 mm x605mm) in ceiling complete all as specified and as directed. Note: The aluminium snap grid frame work shall be measured & paid for separately.
425
-
-
( M & L ) 3mm thick cement base wall care putty on wall and as directed by EIC/SIC.
100
-
-
(M&L) Preparation of old surfaces & apply two coats of oil bound distemper as directed by EIC/SIC.
100
-
-
( M & L ) Rendering 15 mm thick on fair faces of brick work or concrete surface with cement plaster 1 : 4, brushing neat cement slurry with 3.0kg of cement per sq. metreall as directed by EIC/SIC
200
-
-
Removing building materials etc to a distance of 1.0 Km or under, including loading, unloading and stacking at the destination.
20
-
-
Small partition work with Veneered decorative plywood 12 mm , grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work including all assessary/hardware
55
-
-
M/L Granite (of any type) 20mm thick , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete
120
-
-
Providing edge moulding to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete
200
-
-
Solid PVC /WPC Wall Lining consisting of 5mm thick wood grain single side prelam PVC sheet used instead of plain sheet and fixing at site as per requirement with provision of decorative laminate type 1 of surface finish 0.9 mm thick, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instruction
530.73
-
-
Providirg & Laying of special congxund for floor by surfee preparaion by cleaning / gnnding the surface to remove any dust, dirt and any loose material by means of blower / vaccume cleaner of soaked Oil by burning the floor only by applying covete primer with 3mm screed, applying top coat of self leveling Epxoxy Compound 2mm thick of approved colour by spike roller MYK Schomburg / Pedillte / Fosroc / ITW Devcon / Krayon corporation/Asian / Sakshi Chem Science Pvt. Ltd make or Equivalent. The construction ard expansion joints shall be filled with flexible sealing compound and made good before applying epoxy compound to avoid cracks etc. in future, all as specified & directed by Engg-In-charge.
400
-
-
(M&L) Preparation ( Rubbing down and stopping of existing distempered/ painted surfaces.of old plastered surfaces) of walls and applying two coats of coloured exterior acrylic water emulsion paint (1st quality) over and including 2.8 to 3 mm thick Birla white/JK white/Berger wall putty (to achieve smooth surfaces) and a coat of acrylic primer as specified and approved shade as per directed by SIC/EIC. Make: Apex Ultima (Asian) or All Guard Weather coat (Berger, Shalimar,Nerolac) or equivalent as per approved by SIC/EIC.
1200
-
-
S/F Chimney Auto Clean Wall and Ceiling Mounted , FILTERLESS TECHNOLOGY with a motion sensor. The combination of its beautiful appearance and toughened quality . MAXIMUM SUCTION CAPACITY Chimney comes With a suction capacity of 1500 cubic meters per hour, as it is less noisy, low on maintenance, and energy-efficient. with a baffle filter . OIL COLLECTOR, 3 LED lamps . HEAT AUTO-CLEAN TECHNOLOGY. Including Chimney Pipe (FLEXIBLE ALUMINIUM EXHAUST DUCT PIPE 10 Feet) 6 Inch Hose Pipe (7 m) for each.
3
-
-
S/F Sound proof KITCHEN SINK HEAVY-DUTY PREMIUM QUALITY CHROME MATT FINISH (24"×18"×10") including all accessories and fittings.
3
-
-
S/F Brass Automatic Touchless Sensor Faucet Tap (Chrome) Sense-One Pillar Tap Faucet including all accessories and fittings.
3
-
-
S/F Brass, Concealed Circular Body Diverter Full Set with Overhead Shower, Hand Shower and Bath Tub Spout (Chrome) Faucet Set
1
-
-
S/F of powder coating Aluminum doors/2-Track or 3-Track Aluminium sliding Window, Frame section weighing 0.85 to 1.1 Kg/m and shutters aluminum section weighing o.55Kg/m not more than 4 sqm , including half part with glazing , 4.8 mm thick first quality glasss necessary and half with Pre laminated board 12mm, interior grade both sides laminated joining cleats glazing clips riber neoprene packing handles 2 nos in each door/window hings, latches, tower bolts, door aldrops, door stopers, powder coating snap beading screws etc. complete all as specified.
100.8
-
-
Manufacturing, supplying and fixing retro reflective Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base
plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge.
2
-
-
Credit of old/un-usable Fals Celing / particle board panelling including grid any type and size.
520
-
-
Credit of existing steel window/Door
1880
-
-
Credit of old bricks
10
-
-
Credit of old brick bats
15
-
-
Taking down carefully copper /aluminium point wiring (light,socket or power) complete, including fixture and fitting such as switches,ceiling rose,pendants regulators, socket,light , fitting etc removing materials to store/em for keeping in safe custody for taking credit(credit of above items should be made as per conditions sepeatly) and making good disturbed surfaces of walls,floors etc.
250
-
-
(M&L)One light point or one fan point controlled by one switch with cable 1.5 sq mm size wiring with copper conductor cables FRLS pvc single core sheathed cable in PVC conduit. Wiring will be cancelled.
100
-
-
(M&L)One 3 pin socket outlet. 15 amps,independent,with cables 4 sq.mm size Wiring with copper conductor cables FRLS pvc single core sheathed cable in PVC In stove enamelled In PVC conduit
90
-
-
(M&L) Modular switch 1 way 6A, 1 module. Make : Indo Assian, L&T,Havells,Legrand
115
-
-
(M&L) Modular switch 1 way 16A, 1 module.Make : Indo Assian, L&T,Havells,Legrand
90
-
-
(S&F) Modular Socket 6A/16A - 2/3 pin combined, 2 module.Make : Indo Assian, L&T,Havells,Legrand
90
-
-
(M&L) Modular white cover plate wuth frame 3 Moduel (for 5/6+15/16 power point).Make : Indo Assian, L&T,Havells,Legrand
105
-
-
(M&L) Modular white cover plate wuth frame 6 Moduel (for lighting switch).Make : Indo Assian, L&T,Havells,Legrand
20
-
-
(M&L)Modular metal Flush box 3 module.Make : Indo Assian, L&T,Havells,Legrand.
106
-
-
(M&L)One 3 pin 5 amps socket outlet independent but below the switch board of light points in the same vertical plane, with cables. 2.5 sq mm size. with copper conductor cables FRLS pvc single core sheated cable in PVC conduit. Wiring will be cancelled.
15
-
-
(S&F) MODULAR SOCKET, 6A - 2/3 pin combined 2 module, Make: Indo Assian, Havells, Legrand,Anchor, L&T
15
-
-
( Supply & Fixing )Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps. Make: Legrand,Standard,Havell's,L&T,Hager.
20
-
-
(S&F)Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required 2x6.0 sq. mm +
1x4.0 sq. mm earth wire in PVC conduit conceled wiring.
300
-
-
( Supply & Fixing ) Sheet metal enclosure for DB's when MCB to be used,triple pole & neutral,12way ,double door type for light circuit & power socket. Make:Legrands,Siemens,Havell's,Standard,Hager, L&T,Indo Assian.( fixing of MCB DB will be concealed on wall]or as directed by SIS/EIC.(for Light+power scoket+3 phase machine)
6
-
-
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.(i) SP 5 To 32 AMP Make: Legrands,Schnieder Electric,Standard,Hager,Indo Assian.
144
-
-
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
TPN 40 To 100 AMP. Make: Legrand,Siemens,Schnieder electric,Standard,Hager,Indo Assian.
21
-
-
(Supply & Fixing)Isolator Four pole 100 amp for each MCB TPN DBs. Make : Indo Assian, Legrand,Hager,L&T,Standard.
6
-
-
(S&F)Sheet meetal Enclosures for DBs when MCBs to be used single pole & neutral double door 4 way with 200 amps rated bus bar( for 3 phase machines & Acs 11Tr each).Make : Indo Assian, Legrand,Hager,L&T,Standard.
12
-
-
(M&L) ceiling rose ,3 phase/PVC/Polycarbonate ,isolated body. Make: Indo Assian,Anchor,L&T,Cona.
240
-
-
(S&F)Wiring for circuit/submain wiring alongwith earth wire with the 2x2.5 sqmm+1x2.5 sqmm earth wire of FR PVC insulated copper conductor ,single core cable in surface/recesse as required inPVC conduit.concelled wiring.
300
-
-
(S&F) Wiring for circuit/submain wiring alongwith earth wire with the 2x4 sqmm+1x2.5 sqmm earth wire of FR PVC insulated copper conductor ,single core cable in surface/recesse as required in PVC conduit. Concelled wiring.
300
-
-
Cuting holes in brick walls built in cement mortar .exe one brick but not exe two brick.
49
-
-
(M&L) XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core for feediong supply to all MCB TPN DBs & 03 SPB 4 Way DB.Make: Finolex,KEI,Gloster.
250
-
-
(M&L) XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sq. mm 3.5 core from old sub station to lab LT panel.(2 length cable of 300 sqmm).Make: Finolex,KEI,Gloster.
360
-
-
Cutting chases for PVC conduits wiring/cables and sinking's for boxes and making goog to wall ,floors etc in case of recessed or concealed conduit wiring of light & power circuit.
1697
-
-
(M&L)Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, but using galvanised iron strip 25×4mm as earthing lead.
2
-
-
Excavating in trenches ,n exc 1.5 m wide and n exc 1.5 m depth for foundation, etc or for shafts,wells,cesspits,manholes pier holes, etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out.(hard/dense soil) for earth pit.
7
-
-
Returning,filling in,including spreding,leveing,watering and well raming in layers not exc 25 cm.(hard/dense soil) for earthing system.
2
-
-
M & L Galvanised Steel tubes,medium grade, galvanised with all fittings fixed complete to walls and ceiling or laid in floors, bore of tube 25mm .
4
-
-
(supply &fixing) Earth pit making with earth pit cover
2
-
-
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete..MAKE: PHILIPS / CROMPTON / C&S /HAVELLS / BAJAJ / SYSKA / WIPRO.
94
-
-
M & L Galvanised Steel tubes,medium grade, galvanised with all fittings fixed complete to walls and ceiling or laid in floors, bore of tube 100mm for road crossing or as per direction of SIE/EIC.
5
-
-
[M&L] Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chase or buried in groun or drawn in conduit/pipe or fixed to pole or nay other indicated sitiation for loof earthing etc as required 4mm dia galvanised iron or steel wire.
250
-
-
Supply & installation,commissioiing, testing of LT panel hut type floor mounted , water proof ,double door with lock and key arrangment & body earth arrangement consisitng of 14 SWG MS sheet, duly pianted with grey colour & consisitng with following acessories with wirirng / connection :- (i) suitable rating TPN aluminium bus bar having good conductivity , (ii) Digital ampermeter Qty=01 no with suitable CTs(1 set),(ii) KVAH,KWH,P.F,KVA indicated digital meter, =01 No,(iii) Frquency meter =01 no (iv) Digital Voltmeter ,Qty=1 Nos . (v) Three pahse R Y B indicating lamps =1 set (vi) 01 No .For main control.(i) 1 nos ,800 amps four pole MCCB ,415 volts,breaking capapcity 50kA,make :L&T,Hager,Indo assian,Legrand,Siemens,Schnieder Electric. For outgoing circuit (ii) 06 Nos 150/160 amp MCCB 4 pole for outgoing to TPN DBs make :L&T,Hager,Indo assian,Legrand,Siemens,Schnieder Electric (iii) 01 Nos 200 amp MCCB 4 pole, (iv) 03 Nos 125 Amp 4 pole MCCB for 03 Nos 11 TR , make :L&T,Hager,Indo assian,Legrand,Siemens,Schnieder Electric for outgoing to ist floor LT Panel. (v) provision of incoming cable &outgoing cable entry and connection through suitable lug & glands. this LT panel will be installed outside or as per direction of SIC/EIC.
1
-
-
Rough excavation not execeeding 1.5 meter deep & gatting out (hard/dense soil/road)
68
-
-
Returning filling including spradng ,leveling ,watering and well ramming in lays not exe 25 cm (hard/dense soi)
43
-
-
Material & labour sand filling under floor or in foundation including watering and consolidation
17
-
-
Making /repairing of road/floor with cmment concerte type B2 1:2:4 ,40 mm graded aggregate after filling sol in cable trench.
2.7
-
-
Material and laying of bricks ,sub class B ,old size brick laid dry continuos over the sand layer properly.
39.1
-
-
Credit of dismentaled electrical copper cable scrape any size.
30
-
-
Credit of dismentalled alluminium cable /wire scrap any size.
500
-
-
Credit of dismetalled Switch, sockets, AC boxes & DBs, Main Switches.Except all type LED lights.
200
-
-
Indoor/Outdoor Machine1 Air-Conditioning System with Ceiling suspended Ductable units along with associated works:
High Static Ducatable Inverter Heating Cooling ceiling mounted unit with independent circuit energy efficienct scroll compressor with 410 gas filled Capacity-11 TR (including all taxes GST @28 % )
3
-
-
Installation /Commissioning work (Including all taxes GST @18% ):
Ducting Tata/ Sail / including Duct support, angle frame, nut bolt etc, 24 G, 22 G. Acoustic lining of duct with 13 MM open cell nitrile rubber insulation with suitable adhesive from inside of duct. Thermal duct insulation with 9 mm NITRILE shet with factory laminated metpet cladding. Suction and discharge 16/18G copper piping of required size from indoor to outdoor unit with Insulation 9 mm Electrical work and associated cabling
4CX 5mm
1C X 1.5 mm
8SWG earthing wire
You have to provide us with the required incomer power and earthing along with main switch at outdoor panel. Rates are included with required control panel
Initial Nitroget testing, ref. 410 gar charging, commissioning
(including all taxes GST etc )
V.I. Pads
Canvass Connection
MS Fabricated outdoor stand
Voltage stablizers, if required to botain voltage as under: 415V +/- %, Three Phas, 50 Cycles
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements