Ghaziabad Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Ghaziabad Development Authority - GDA Tender

Works
Building Construction
Eprocure
Opening Date2 May 2018
Closing Date16 May 2018
Tender Amount₹ 16,74,12,830 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of 120 Multistorey flats at Chandrasheela Apartments, Nehru Nagar-II Ghaziabad
Construction of 120 Multistorey flats at Chandrasheela Apartments, Nehru Nagar-II Ghaziabad
Construction of 120 Multistorey flats at Chandrasheela Apartments, Nehru Nagar-II Ghaziabad
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
g) Columns, Pillars, Piers, Abutments, Posts and Struts.Si No:5.9.6

2622.8

-

453.35

... More
g) Stairs, (excluding landings) except spiral-staircases.Si No:5.9.7

123.8

-

395.65

... More
h) Arches, domes, vaults up to 6 m spanSi No:5.9.9

5

-

1066.3

... More
i) Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.Si No:5.9.15

134.44

-

196.45

... More
J) Edges of slabs and breaks in floors and walls Under 20 cm wideSi No:5.9.16.1

986.1

-

116.4

... More
L) Weather shade, Chajjas, corbels etc., including edges.Si No:5.9.19

10

-

492.35

... More
m) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) 5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).Si No:5.11.1

55

-

159.05

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete all level. Thermo-Mechanically Treated bars.Si No:5.22.6

283020

-

68.1

... More
b) All works above plinth level upto floor V level. SI No 5.33.2

1158

-

7014.55

... More
Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/Cum).Si No:5.34.1

496.8

-

76.5

... More
Extra for R.C.C / B.M.C / R.MC.C. work above floor V level for each four floors or part thereof. Si No:5.38

1959.4

-

174.2

... More
Expansion Joint Providing & fixing 100mm thick shalitax board fixing to be expansion joint as per approved make and design etc. complete as per the direction of Engineer-in-charge.Si No:NSI

62.3

-

175

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self – centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge . (Material shall confirm to ASTM 6063.) Floor Joint of 100 mm gapSi No:5.44.1

121.2

-

6358.55

... More
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063.) Wall Joint of 100 mm gapSi No:5.45.1

86.6

-

5080.9

... More
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its omponents. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. Roof Joint of 100 mm gapSi No:5.46.1

98.7

-

6358.55

... More
Brick work with F.P.S. bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)Si No:NSI

209.8

-

5725

... More
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.Si No:NSI

236

-

265

... More
Half brick masonry with F.P.S. bricks of class designation 150 in foundation & plinth in. cement mortar 1:4 (1 cement : 4 coarse sand)Si No:NSI

21.3

-

625

... More
Half brick masonry with F.P.S. bricks of class designation 150 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand)Si No:NSI

7336

-

695

... More
Extra for half brick masonry in superstructure above floor V level, for every four floors or part thereof by mechanical means.Si No:NSI

10268.8

-

25

... More
MARBLE & GRANITE WORK Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade .Area of slab over 0.50 Sqm.( For Counter)Si No:8.2.2.2

290.5

-

3907.4

... More
Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. 8mm thick (mirror polished and machine cut edge) Granite stone of any colour and shadeSi No:7.38.1.1

185.72

-

1725

... More
Extra for providing edge moulding to 18mm thick marble stone counters, Vanities ect. Including machine polishing to edge to give high gloss finish ect. Complete as per design approved by Engineer - in Charge. Granite workSi No:8.3.2

417.1

-

230.55

... More
Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin baesd adhesive including cleaning etc. complete.Si No:8.4

417.1

-

247.4

... More
WOOD & PVC WORK Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.Si No:9.20.1

270.7

-

2606.45

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.Si No:9.21.1

1232.3

-

1909.55

... More
Window Shutter Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second class teak wood a) 30 mm thick shuttersSi No:9.5.1.2

703

-

2406.3

... More
b) Kiln seasoned and chemically treated hollock wood 30 mm thick shuttersSi No:9.5.2.2

1.4

-

1581

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)Si No:9.53

2220

-

117.35

... More
Approximate cost of ISI marked oxidized iron fitting with screws for door & windows etc. (for estimating purpose only) As Above item no 473 Aluminium Fitting ISI marked.Si No:4.74(P.W.D)

2773

-

340

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat . Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.Si No:9.121

10.4

-

482.2

... More
Providing and fixing to existing door frames. 30mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.Si No:9.122.2

5

-

2749.6

... More
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).Si No:9.136

10.4

-

1250.05

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-charge. With clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistanceSi No:9.138.1

10

-

27658.7

... More
Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ). Cylindrical LockSi No:NSI

872

-

1450

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete.Si No:10.25.1

150

-

73.5

... More
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.Si No:10.25.2

37998.8

-

90.1

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)Si No:10.15.1

18276.4

-

139.1

... More
Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)Si No:10.15.2

7560

-

130.4

... More
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 80 mmSi No:10.27.2

1123.2

-

70.75

... More
10 x 120 mmSi No:10.27.3

2131.2

-

86.75

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)Si No:10.11.1

4127.25

-

114.15

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panesSi No:10.30.1

635

-

764.45

... More
FLOORING WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)Si No:4.1.3

35

-

5466.3

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.Si No:11.6

76.23

-

377.25

... More
Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Makrana White second qualitySi No:11.23.1

1514.8

-

3360.45

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.Si No:11.26.1

933.9

-

1141.4

... More
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.Si No:11.27

5.6

-

1191.25

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm. including pointing in white cement mixed with pigment of matching shade complete.Si No:11.36

2788.3

-

836.65

... More
Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.Si No:11.4

2203.3

-

1009.6

... More
Providing & Laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer) with water absorption's less than 0.08% and confirming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc, complete. Size of Tile 60 x 60 cm Si No:11.41.2

6578.7

-

1405.95

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 ce ment : 3 fine sand) as per standard design : In 75x75 mm deep chaseSi No:12.21.1

285

-

143.1

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.Si No:12.22

32

-

186.65

... More
FINISHING WORK 12 mm cement plaster of mix : a) 1:4 (1 cement: 4 coarse sand) for wallsSi No:13.4.1

22066.5

-

172.3

... More
b) 1:4 (1 cement: 4 coarse sand)for ceilingSi No:13.4.1

10030.3

-

172.3

... More
15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)Si No:13.5.1

9179.1

-

200.05

... More
Add or deduct for plaster drip course/ groove in or moulding to R.C.C. projections.plastered surfaceSi No:5.3

5453

-

30.75

... More
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.Si No:13.22

39359.9

-

37.95

... More
Providing & Laying two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)Si No:NSI

32096.8

-

75

... More
Providing and applying one coats of cement paint, "SNOWCEM" of approved shade at all heights including necessary scaffolding, surface preparation, curing, etc., complete as per the specifications and the drawings.Si No:NSI

14109.6

-

35

... More
Extra for two coat.Si No:NSI

4566.4

-

20

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer.Si No:13.41.1

32096.8

-

89.7

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primerSi No:13.43.1

31732.6

-

35.85

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.Si No:13.45.1

9543.2

-

146.45

... More
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 Sqm. over an under coat of primer applied @0.75 ltr/ 10 Sqm. of approved brand or manufactureSi No:13.48.2

3006

-

88.2

... More
Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)Si No:13.50.1

3006

-

32.95

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new workSi No:13.61.1

1279.7

-

74.4

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : (i) Ist course of applying cement slurry @ 4.4 Kg/Sqm. mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per Sqm. of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to Each other with bitumen @ 1.7 Kg/Sqm..)Si No:22.3

2225

-

522.9

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/Sqm.. of cement admixed with water proofing compound conforming to IS. 2645 and a+C139 approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the With average thickness of 120mm and minimum thickness at khurra as 65 mm.Si No:22.7.1

793.98

-

1019.05

... More
Sunken area filling Supplying and stacking Over burnt (Jhama) brick aggregate 120 mm to 40 mm.Si No:16.3.4

518.3

-

657.1

... More
Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement:3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat ( item of laying brick tiles shall be paid for separately).Si No:22.15

1916.3

-

526.25

... More
(B) EXTERNAL DEVELOPMENT WORKS BOUNDARY WALL EARTH WORKS Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soils .Si No: 2.6.1

275.3

-

155.6

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). .Si No: 4.1.8

11.5

-

4301.15

... More
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) .Si No: 4.1.10

15.3

-

4004

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. .Si No: 5.9.1

254.9

-

196.45

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. .Si No: 5.9.2

142

-

360.8

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers .Si No: 5.9.5

257.5

-

332.15

... More
Columns, Pillars, Piers, Abutments, Posts and Struts. .Si No: 5.9.6

579.4

-

453.35

... More
Arches, domes, vaults up to 6 m span .Si No: 5.9.9

126.1

-

1066.3

... More
Thermo-Mechanically Treated bars. .Si No: 5.22.6

12954.1

-

68.1

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars. .Si No: 5.22A.6

10200

-

68.1

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. a) All works upto plinth level. .Si No: 5.33.1

100.5

-

6296.15

... More
b) All works above plinth level upto floor V level. .Si No: 5.33.2

68

-

7014.55

... More
Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). .Si No: 5.34.1

43.5

-

76.5

... More
Brick work with F.P.S. bricks of class designation 150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) .Si No: NSI

0.5

-

5050

... More
Brick work with F.P.S. bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) .Si No: NSI

143.1

-

5725

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. .Si No: 10.25.1

150

-

75.3

... More
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. .Si No: 10.25.2

1980

-

90.1

... More
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. .Si No: 16.19

935.5

-

70.9

... More
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) .Si No: 16.53

315

-

287.05

... More
Providing and applying 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand ) and a top layer 6 mm thick cement plaster 1 : 3 ( 1 cement : 3 coarse sand ) finished rough with sponge . .Si No: 13.12

889.5

-

258.9

... More
Add or deduct for plaster drip course/ groove in or moulding to R.C.C. projections.plastered surface .Si No: 5.3

250

-

30.75

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. .Si No: 13.21

150

-

50.65

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer. .Si No: 13.43.1

889.5

-

35.85

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. .Si No: 13.45.1

889.5

-

146.45

... More
Applying priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on Steel works .Si No: 13.50.3

66

-

27

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work .Si No: 13.61.1

66

-

74.4

... More
Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in- charge (payment for providing grooves shall be made separately). .Si No: 13.72

685.5

-

553.45

... More
Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 15 mm wide and 15 mm deep groove .Si No: 13.73.1

993.6

-

31.6

... More
ROAD, HORTICULTURE & LANDSCAPE Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soils Si No.: 2.6.1

1376

-

155.6

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. . Si No.: 2.25

176.8

-

112.4

... More
Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete Si No.: 2.27

192.4

-

910.25

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. Si No.: 2.31

39.9

-

642

... More
Carriage of materials by mechanical transport including loading, unloading and stacking Earth for 5km Si No.: 1.1.2

962.5

-

153.07

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Si No.: 4.1.8

192.4

-

4301.15

... More
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) Si No.: 4.1.10

29.3

-

4004

... More
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. Si No.: 10.25.2

500

-

90.1

... More
12 mm cement plaster of mix : 1:4 (1 cement : 4 coarse sand) Si No.: 13.4.1

552.5

-

172.3

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres. Si No.: 16.1

1924

-

81.29

... More
Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Si No.: 16.7.1

250

-

124.3

... More
Construction of un-reinforced, dowel jointed, plain quality concrete of M-40 grade in road/pavement/taxi track etc. for all leads and lifts over a prepared sub base with 43 grade cement @ 360 kg. (minimum) per Cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, in transit mixture, laid with fully automatic slip form paver with electronic sensor with dowel bar and tie rod insertor, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing and as per direction of Engineer-in-charge (including all cost of form work, dowel bars and tie bars). Si No.: 16.93

182.5

-

2090.3

... More
Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats) Si No.: 16.47.1

750

-

109.3

... More
Making bell mouth opening/ entrance of size 100x50x50cm for drainage pipe under footpath including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) for shape of bell mouth including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete. Si No.: 16.49

250

-

1807.85

... More
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. Si No.: 16.42

301.4

-

5450.45

... More
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction and of approved size and design/ shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. Si No.: 16.68

707.2

-

602.2

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). Si No.: 16.69

12.8

-

5295.9

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 250 mm diameter S.W. pipe Si No.: 19.3.4

93.6

-

624.6

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe Si No.: 19.6.3

93.6

-

468.6

... More
Supplying and stacking of good earth at site including royalty and carriage upto 1 km (earth measured in stacks will be reduced by 20% for payment). Si No.: 23.2

962.5

-

308.35

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) Screened through sieve of I.S. designation 20mm Si No.: 23.4.1

962.5

-

167.6

... More
Mixing earth and sludge or manure in proportion specified or directed. Si No.: 23.9

1200

-

17.25

... More
Grassing with ‘Doob’ grass includ­ing watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately). In rows 5 cm apart in either direction. Si No.: 23.10.1

950

-

841.25

... More
Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid for separately). Si No.: 23.11

950

-

1626.75

... More
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked Si No.: 23.13

550

-

105.2

... More
GUARD ROOM Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soilsSi No. 2.6.1

19.81

-

155.6

... More
Supplying and filling in plinth with river sand under floors including, watering, ramming consolidating and dressing complete.Si No. 2.27

3.3

-

910.25

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).Si No. 4.1.8

3.11

-

4301.15

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.Si No. 5.9.1

13.37

-

196.45

... More
Columns, Pillars, Piers, Abutments, Posts and Struts.Si No. 5.9.6

4.05

-

453.35

... More
Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.Si No. 5.9.15

5.21

-

196.45

... More
Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12mm thick.Si No. 5.9.20

27.28

-

493.55

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12mm thick.Si No. 5.9.21

42.95

-

423.65

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars.Si No. 5.22.6

1472.7

-

68.1

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). a) All works upto plinth levelSi No. 5.33.1

4.42

-

6296.15

... More
b) All works above plinth level upto floor V levelSi No. 5.33.2

8.46

-

7014.55

... More
Brick work with F.P.S. bricks of class designation 150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)Si No. i

1

-

5050

... More
Brick work with F.P.S. bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)Si No. i

9.19

-

5725

... More
Half brick masonry with F.P.S. bricks of class designation 150 in foundation & plinth in. cement mortar 1:4 (1 cement : 4 coarse sand)Si No. i

1

-

625

... More
Half brick masonry with F.P.S. bricks of class designation 150 in superstructure above plinth level up to floor V level.cement mortar 1:4 (1 cement : 4 coarse sand)Si No. i

10

-

695

... More
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.Si No. 9.20.1

3.6

-

2606.45

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second class teak wood 30 mm thick shuttersSi No. 9.5.1.2

8.3

-

2406.3

... More
Approximate cost of ISI marked oxidized iron fitting with screws for door & windows etc. (for estimating purpose only) As Above item no 473 Aluminium Fitting ISI marked.Si No. 4.74(P.W.D)

11.87

-

340

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)Si No. 10.15.1

170.3

-

139.1

... More
Providing & Laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer) with water absorption's less than 0.08% and confirming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc, complete.Si No. 11.41Size of Tile 60 x 60 cm Si No. 11.41.2

17.2

-

1405.95

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chaseSi No. 12.21.1

24.8

-

143.1

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.Si No. 12.22

4

-

186.65

... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)Si No. 13.4.1

59.5

-

172.3

... More
15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)Si No. 13.5.1

64.3

-

200.05

... More
Providing & Laying two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)Si No. NSI

59.53

-

110

... More
New work (two or more coats) over and including priming Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade coat with cement primer.Si No. 13.41.1

59.53

-

89.7

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primerSi No. 13.43.1

59.53

-

35.85

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.Si No. 13.45.1

64.3

-

146.45

... More
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 Sqm. over an under coat of primer applied @0.75 ltr/ 10 Sqm. of approved brand or manufactureSi No. 13.48.2

23.75

-

88.2

... More
Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)Si No. 13.50.1

23.75

-

32.95

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new workSi No. 13.61.1

17.03

-

74.4

... More
Terrace Water Prooifng Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and a+C139 approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the With average thickness of 120mm and minimum thickness at khurra as 65 mm.Si No. 22.7.1

19.5

-

1019.05

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 560 mm internal diameterSi No: 19.19.3.1

2

-

1511.55

... More
Approximate cost of ISI marked oxidized iron fitting with screws for door & windows etc. (for estimating purpose only) As Above item no 473 Aluminium Fitting ISI marked.Si No: 4.74(P.W.D)

6.2

-

340

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required A) In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete.Si No: 10.25.1

50

-

75.3

... More
B) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.Si No: 10.25.2

273.7

-

90.1

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)Si No: 10.13.1

114.6

-

83.7

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal bracesSi No: 10.5.1

1.89

-

3073.85

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panesSi No: 10.30.1

4.3

-

764.45

... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.Si No: 11.4

44.5

-

535.25

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement 18 mm thickSi No: 11.6.1

3.7

-

377.25

... More
Extra for laying terrazo flooring on staircase treads not exceeding 30 cm in width, including cost of forming, nosing etc.Si No: 11.14

44.46

-

36.85

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge Si No: 11.36

180.7

-

836.65

... More
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, expect White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1: 4 (1 Cement : 4 Coarse sand ) including pointing the joints with white cement and matching pigments etc., complete.Si No: 11.38

26.4

-

904.45

... More
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.Si No: 12.2

26.4

-

487.85

... More
12 mm cement plaster of mix : A) 1:4 (1 cement: 4 coarse sand) for wallsSi No: 13.4.1

115.9

-

172.3

... More
B) 1:4 (1 cement: 4 coarse sand)for ceilingSi No: 13.4.1

65.96

-

172.3

... More
15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)Si No: 13.5.1

83.4

-

200.05

... More
Add or deduct for plaster drip course/ groove in or moulding to R.C.C. projections.plastered surfaceSi No: 5.3

32

-

30.75

... More
Providing & Laying two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)Si No: NSI

181.89

-

110

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer.Si No: 13.41.1

181.89

-

89.7

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)Si No: 13.46.1

83.4

-

90

... More
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufactureSi No: 13.48.2

3.78

-

88.2

... More
Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)Si No: 13.50.1

3.78

-

32.95

... More
Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) Two or more coats on new workSi No: 13.61.1

32.4

-

74.4

... More
Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement:3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat ( item of laying brick tiles shall be paid for separately).Si No: 22.15

26.4

-

526.25

... More
INTERNAL PLUMBING SANITARY INSTALLATIONS & C.P FITTINGS Providing and fixing white viterous china extended wall mounting water closed of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/d litres), including seat cover and cistern fitting, nuts, bolts and gasket etc complete. Si No: 17.78

240

-

10100.9

... More
40 mm dia Si No: 17.28.1.2

120

-

82.6

... More
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm Si No: 17.10.1.1

120

-

7052.15

... More
CP Brass fittings Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore Si No: 18.21.2.1

960

-

68.6

... More
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a) 110mm Si No: 12.43.2

1200

-

189.05

... More
Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) a) 110 mm dia Si No: DSR no.19.2.1

450

-

592.6

... More
b) 90 mm dia Si No: DSR no.19.2.1

1050

-

340

... More
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm Si No: 12.41.2

1350

-

231.65

... More
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend Si No: 12.42.5.2

35

-

161.55

... More
Shoe (Plain) 110 mm Shoe Si No: 12.42.6.2

35

-

295.1

... More
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm Si No: 12.43.2

796

-

189.05

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. Si No: 12.22

35

-

186.65

... More
Providing and fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Internal work (exposed on wall) a) 32mm dia nominal outer dia pipes Si No: 18.9.4

2000

-

262.35

... More
b) 25mm dia nominal outer dia pipes Si No: 18.9.3

650

-

209.5

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. a) 20mm dia nominal outer dia pipes Si No: 18.8.2

1715.4

-

296.4

... More
32mm dia nominal bore Si No: 18.10.4

250

-

343.2

... More
40mm dia nominal bore Si No: 18.10.5

30

-

425.65

... More
65mm dia nominal bore Si No: 18.12.7

450

-

524.25

... More
80mm dia nominal bore Si No: 18.12.8

25

-

637.05

... More
32mm dia nominal bore Si No: 18.38.4

250

-

17.7

... More
40mm dia nominal bore Si No: 18.38.5

30

-

21

... More
65mm dia nominal bore Si No: 18.40.7

450

-

17.45

... More
80mm dia nominal bore Si No: 18.40.8

25

-

20.25

... More
32mm dia nominal bore Si No: 18.46.4

90

-

240.75

... More
40mm dia nominal bore Si No: 18.46.5

10

-

16.25

... More
65mm dia nominal bore Si No: 18.46.7

150

-

636.3

... More
80mm dia nominal bore Si No: 18.46.8

8

-

729.25

... More
b) 32mm dia nominal bore Si No: 18.17.2

90

-

501.5

... More
d) 50mm dia nominal bore Si No: 18.17.4

8

-

750.75

... More
e) 65mm dia nominal bore Si No: 18.17.5

14

-

1287.75

... More
Providing and fixing in floor and wall face unplasticised Rigid PVC soil and waste water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110mm dia P.V.C. pipe Si No: NSR(AR-06)

2450

-

525

... More
b) 90mm dia P.V.C. pipe Si No: NSR(AR-06)

1050

-

420

... More
Providing & fixing PVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince) Si No: NSR(AR-03)

993

-

405

... More
Providing and fixing terminal guard. a) 110mm Si No: NSR(AR-04)

50

-

60

... More
Providing & fixing of medium class G.I.spout (Class B) up to 300 mm. length including cutting and making good the walls and floors etc. as required. Si No: NSR(AR-02)

350

-

235

... More
Providing and fixing clean out plug 160 mm dia. Si No: NSR(AR-01)

22

-

695

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. (a) 110mm bend Si No: NSR(AR-05)

290

-

170

... More
Coupler 110mm Si No:

1750

-

115

... More
Coupler 90mm Si No:

750

-

105

... More
Single tee with door 90x90x90 mm Si No:

48

-

195

... More
Single tee with door 110x110x110 mm Si No:

273

-

230

... More
Single tee with door 110x110x90 mm Si No:

240

-

205

... More
Single tee with door 160x160x110 mm Si No:

85

-

550

... More
Providing and fixing M.S. structural work fabricated from standard sections e.g. M.S. pipes, angles, channels, GI 'U' clamps including cutting to size, drilling, welding to insert plates or fixed to "HILTI"fasteners of required specification in RCC structural/masonry members as directed by Engineer-in-Charge including cutting and making good the walls and floors and painting with two coats of enamel paint over primer coat after rubbing and cleaning (for pipe supports, clamps, M.S. ladder and tank manholecovers, etc). wherever required after rubbing and cleaning. Si No: NSR

25

-

70

... More
Providing and fixing pvc Inlet fitting with 2 inlets 80 mm size fabricated from 110 mm dia PVC pipes(approx. length=150mm to 300mm) and fixed to PVC trap with joint and set in cement concrete as per standard drawing complete. Si No: NSR(AR-11)

432

-

620

... More
Providing C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. Si No: NSR(AR-12)

240

-

700

... More
Providing and fixing in floor and wall face unplasticised Rigid PVC soil and waste water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion with fittings etc complete 160mm dia Si No: NSR(AR-06)

500

-

905

... More
Providing & fixing forged brass pressure reducing valve with SS seal, metallic brass diaphram system suitable for controlling outlet pressure of water having inlet range of maximum 20 kg/cm2 and outlet range of 0.5-6 kg/cm2, complete with screwed ends as required. (make : ZOLOTO) 32 mm nominal bore Si No: NSR(AR-13)

60

-

6895

... More
Providing and fixing in position vent connection to water storage tanks comprising two elbows of 50 mm dia. And mosquito proof brass wire mesh fixing in frame and welded to upstand pipe complete as required. (Length of pipe involved shall be measured seperately under item piping). Si No: NSR(AR-07)

14

-

385

... More
Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset Model : STS 50/13 - F (1 working + 1 Standby) = 2 Set, Discharge in LPH : 6000-18000 LPH, Head in Mtrs. : 11 - 5 Mtr HP : 1.0 HP, Free Passage : 35 mm, Outlet : 50 mm, Price of Pumpset : 82278.00(2Set) Si No: NSR(QUO)

3

-

82278

... More
EXTERNAL WATER SUPPLY WORKS Providing and laying double flanged (Screwed/Welded) centrifugally (Spun) Ductile iron pipes of class K-9 conforming to IS 8329 a) 100mm dia Ductile iron double flangedSi No: 18.73.1

100

-

2564.75

... More
Supply CI specials such as Bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete. 10 % of above item Si No:

10

-

2564.75

... More
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter.Si No: 2.10.1.2

100

-

208.3

... More
Providing push-on-joints to centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket : 100mm dia pipesSi No: 18.70.1

30

-

61.85

... More
Provision of construction of 1:1.5:3 RCC thrust blocks for water hammer at bends of pipes.Si No: 5.1.2

0.5

-

6230.2

... More
Supply of reinforcement including cutting, bending etc. Si No: 5.22.3

40

-

68.1

... More
Providing and fixing C.I. Sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): a) 100mm diameter Si No: 18.31.1.2

3

-

3921.3

... More
Provding and fixing C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately.a) 50mm dia Si No: 18.59.1

1

-

4778.3

... More
DISTRIBUTION SYSTEM Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 80mm nominal bore.Si No: 18.12.8

25

-

637.05

... More
65mm nominal bore.Si No: 18.12.7

100

-

524.25

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 80mm nominal bore.Si No: 18.17.6

1

-

1920.6

... More
65mm nominal bore.Si No: 18.17.5

2

-

1287.75

... More
Constructing brick masonry chamber 900 x 900 x 1000 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement: 4 coarse sand) for Sluice Valve, with C.I.surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab with 1:2:4 mix (1 cement: 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design Si No: 18.34.1

3

-

11672.35

... More
Providing Fixing & Testing Commissioning of three phase 50 Hz Ac Vertical Inline multi stage hydro pneumatic pump system (2 working + 1 stand by) of WILO make along with common base frame and common header on delivery side with guage etc. Discharge : 17.5 M3/H, Head : 60 Mtr. KW : 5.5 KW, Control Panel of System Complete with software duly installed and reqired switchgear. Pressure Tank 440 Ltr. Solenoid Valve 65 mm of 10 Kg with low-high level controller and making of bypass arrangement including G.I. Pipe accessories. Isolation valve 65 mm Isolation valve 100 mm, Foot valve, Non return ValveG.I. Pipe for Common header and accessories, Guages & Electrical Pressure switchesSi No: MR

1

-

1278725

... More
CONSTRUCTION OF TUBE WELL PUMP ROOM Drilling of 500mm dia Bore by direct rotary percussion pnematic hydraulic jet machine Reverse rotary method as found suitable as per site a) 0.00 M to 60mSi No: MR

60

-

1125

... More
b) 60.00m to 90 m Si No: MR

30

-

1170

... More
c) 90.00m to 150mSi No: MR

60

-

1215

... More
Transportation of rig machine, air compressor O.P. Unit, pipes etc. complete Si No: MR

1

-

58500

... More
Water arrangement for drilling, O.P. Unit, pipes etc. complete. Si No: MR

1

-

31500

... More
(a)Supply of Tube Well assembly including all expenses complete upto site of work conforming IS : 6589, 3580/1976 etc. 300mm dia M.S. E.R.W. Blind pipe 8mm thickness complete. Si No.: MR

90

-

4544.04

... More
(b)300mm dia M.S. E.R.W. Slotted pipe 8mm thickness complete. Si No.: MR

60

-

4544.04

... More
(c)300mm dia Ring Si No.: MR

30

-

1530

... More
(d)300mm dia Socket for Johnson Screen Si No.: MR

10

-

5850

... More
(e)300mm dia Housing clamp. Si No.: MR

1

-

2250

... More
(f)300mm dia well cap Si No.: MR

1

-

1710

... More
(g)300mm dia M.S. Well Plug. Si No.: MR

1

-

1275

... More
(a)Lowering of Tube assembly as per direction of by E/I. complete. Lowring of 300mm dia M.S. Pipe Si No.: MR

90

-

225

... More
(b)Lowering of Johnson Screen Si No.: MR

60

-

180

... More
(c)Supply and Packing of 1.5mm to 4mm Size Pea gravel. Si No.: MR

30

-

2520

... More
(a)Devlopment of Tube Well by air compressure Development of Tube Well Si No.: MR

60

-

855

... More
(b)Development of Tube Well by O.P. Unit Si No.: MR

100

-

765

... More
Geophysical investigation of the acquifer by electrologing system with all tool and plant as necessary including submission of report in triplicate. Si No.: MR

1

-

27900

... More
Yield test for sand free discharge Si No.: MR

1

-

19800

... More
Collecting sample of water for bacteriological and chemical test as per S.I. 10500 Si No.: MR

1

-

18900

... More
S/Installation of submerssible type pump and motor 500 lpm discharge 60 m head three phase I.S.I. Mark Kirloskar, Pump etc. as approved by Engineer Incharge complete. Si No.: MR

1

-

90000

... More
S/F of 150mm dia column assembly indicating pipe, N.R.V. Sluice Valve all Specials etc. upto pump house complete. Si No.: MR

1

-

144000

... More
150mm dia M.S. Clamp Si No.: MR

1

-

450

... More
S/erection of electronic/electro mechanical type chlorinating plant of 100 litres capacity suitable to Inject Bleaching powder solution upto 10 Kg. / cm2 pressure complete in all respect including installation commission and testing etc. complete. Chlorinator plant include following- Pump : Pump should be a capacity of inject liter per Hr. of Bleahing powder solution in pipe line at pressure of 10 Kg/cm2 as per SI 5639, pump shall be capable to in fect required doseg bleaching powder solution in pipe line at apressume of 10 Kg/cm2 as per IS 5639 complete. Motor : 3 Phase 415 V50 Cycle/Sec. Starter : Automatic D.O.L. Type of suitable capacity. Power Wiring : 3 Phase of suitable size copper cable should be done from TPIC Switch Filter Reinforced Polymer Tank : 150lt. capacity of good quality reputed which make should be approved by E/I. Test Kit : One Packet size test kit to test the residual chlorine at the remote end. Si No.: MR

1

-

100000

... More
Suply installation testing and commissioning of electric panel board for tube well duly internally wired made of 14 S.W.G. Sheet with 2 coat of finish painting with powder coating and fitted with following. MR6.3 amp. TPN MCCB 0 to 500 Volts 90x96 sqmm V Meter with Selector 0 to 63 Amp. 96x96mm Sq. A meter with 100/5 Amps. 15 V ACL / CTS and Sector Switch (10 Set) Phase indicating lamps shall be protected by 2 amp. S.P. Mem (60 Set) (a) 100A TPN Al. Bus BarOut going with 2 Nos. suitable relating MPCB For 15 H.P.D.O.L. starter and outgoing feeder to tube well pump motor (including / no stand by) Each compartment contain auto / manual selector switch indicator push tollon lamps with MCB for ON/OFF/TRIP of Motor. Si No:

1

-

67500

... More
S/Installation 10 sqmm copper cable foS/Instllation 10sqmm copper cable for Ductable Pump complete. Si No.: MR

150

-

189

... More
SEWERAGE WORKS Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mm diameter Si No: 2.10.1.2

200

-

208.3

... More
1.50 m to 3.00 m depth Pipes 80 mm to 300 mm diameter Si No: 2.11

100

-

283.28

... More
Depth 1.5 to 3.00 meter Si No: 2.20.2

100

-

59.55

... More
b) 250 mm. dia. RCC Pipes Si No: 19.6.3

200

-

468.6

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design Si No: 19.3.2

200

-

456.45

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line Si No: 19.7.1.1

12

-

8507

... More
Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 Si No: 19.8.1.1

6

-

5638.2

... More
Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line Si No: 19.7.2.1

4

-

18304.45

... More
Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 Si No: 19.8.2.1

2

-

6753.65

... More
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. Si No: 19.16

32

-

311.6

... More
FIRE FIGHTING SYSTEM Supply & erection of ISI marked portable fire extinguishers, confirming to IS:15683, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions of Engineer-in-charge. (MAKE : Minimax / Cease Fire / Safex / Safeguard / UFS) Water a) CO2 gas cartridge type. 9 Lt.capacity (IS:940)

26

-

3450

... More
b) CO2 gas type. 4.5 kg. Capacity (IS:2878)

26

-

8165

... More
Supply & fixing of 4 nos. G.I. round bottom fire buckets of 9 liters capacity filled with sand including proper supporting / mounting arrangements in MS angle iron frame, painted by fire red colour over two coats of red oxide paint and written with white paint "FIRE" complete in all respects as per the directions of Engineer-in-charge.

2

-

3079

... More
Supply, erection and testing of ISI marked ERW M.S. pipes (Class C - heavy duty) and specials etc. (as per IS:1239 for upto 150 mm dia and IS:3589 for 200 mm and above) for above ground laying for hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing / erection of pipes including specials i.e. bends, tees, reducers, flanges, expansion joints and bellows wherever required, washers, nuts, bolts etc. in proper position including all supports. jointing by welding, aligning the pipe line, painting with two primer coat by zinc chromate primer and two coats of synthetic enamel fire red colour, providing tapping for pressure gauges and for other instruments etc. Hydrostatic testing of system at 1.5 times of operating pressure or 15 kg / sq cm whichever is higher and as specified, flushing & cleaning by water etc. complete as per drawings & direction of the Engineer-in-charge. The pipes and accessories will be provided with all type of supports (Maximum Support spacing = up to 25 mm dia @ 2 m, 32 mm to 100 mm dia @ 2.5 m, 150 mm & above dia @ 3 m) by minimum 3 mm thick G.I. clevis / sprinkler hangers / clamps / Tie rod supports with G.I. nuts, bolts, anchor / dash fastner and washer for hydrant / sprinkler piping, for 150 mm dia pipe the support will be through 50x50x6 mm painted / pre galvanized MS angle iron along with G.I. U clamp, nuts, washers, anchor fasteners etc as the case may be. upto 40mm dia. pipe threaded fittings and threaded joints shall be provided and for 50mm dia & above pipes welded joints shall be used. The D.I. / Malleable Iron (IS : 1879) fittings shalll be heavy duty suitable to withstand at least a pressure of 150% of maximum working pressure with minimum of 15kg/cm2. (Pipe make : Jindal (Hissar) / Prakash Surya) (M.I. & D.I. Fitting make : UNIK / Jainsons) a) 25 NB (IS: 1239, 4.0 mm thick)

900

-

355

... More
b) 32 NB (IS: 1239, 4.0 mm thick)

450

-

430

... More
c) 40 NB (IS: 1239, 4.0 mm thick)

125

-

485

... More
d) 50 NB (IS: 1239, 4.5 mm thick)

25

-

649

... More
e) 65 NB (IS: 1239, 4.5 mm thick)

25

-

822

... More
f) 100 NB (IS: 1239, 5.4 mm thick)

80

-

1394

... More
g) 150 NB (IS: 1239, 5.4 mm thick)

125

-

2000

... More
Same as in item above but of G. I. Class B - medium duty for drainage pipe. 80 NB (IS: 1239, 4.0 mm thick)

25

-

1160

... More
a) Providing & fixing neoprene rubber double flanged rubber expansion joint (anti vibration bellow) of standard length as per manufacturers specifications. suitable for hydrostatic test pressure of 21 kg/sqcm including all necessary fittings i.e. rubber gasket, nuts, bolts, washers etc complete as required. (Make : Easyflex / Resistoflex / Kanwal / Precise) 80 mm dia.

2

-

4140

... More
b) 150 mm dia.

4

-

7130

... More
Supply & installation of ISI marked single headed 63 mm dia. Stainless steel Hydrant Valve (Type A) suitable for hydrostatic test pressure of 21 kg/sqcm, 80 mm dia flanged inlet with 63 mm female instantaneous outlet confirming to IS : 5290 on the fire wet riser/down comer, including making 80 NB pipe connection with riser, fixing the landing valves in proper positions, including supply of nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect as per directions of the Engineer-in-charge. (MAKE : Newage / Safeguard / Padmini / Getech)

30

-

10392

... More
a) Supply & fixing in position ISI marked cast iron double flanged butterfly valves as per IS:13095, (PN 16) with SS disc, shaft, seating rings, nitrile rubber lining, internal fastening, nuts, bolts including transporting to worksite, 3 mm thick rubber gaskets etc. including testing, Complete as per drawings & directions of the Engineer-in-charge. (MAKE : IVC / Venus / Audco / Advance / SKS / CRI / AIP) 100 MM NB

7

-

5635

... More
b) 150 MM NB

13

-

6026

... More
a) Supply & fixing in position cast iron body double flange dual plate wafer type check valve (NRV) (PN 16), with SS 304 plates, hinges, pins, springs, nitrile rubber lining, including transportation to worksite, supply & fixing SS nuts, SS bolts, 3 mm thick rubber gaskets, complete with testing as per direction of the Engineer - in - charge. (MAKE : IVC / Venus / Audco / Advance / SKS / CRI / AIP) 100 NB

3

-

11588

... More
b) 150 NB

3

-

9177

... More
a) Providing and fixing C I body flanged S S strainer fabricated out of 1.6 mm thick Stainless Steel 304 sheet with 3 mm dia hole, suitable for hydrostatic test pressure 16 kg/sqcm complete. (Make : Advance / Audco / SKS / AIP) 100 mm dia

2

-

9900

... More
b) 150 mm dia

1

-

13728

... More
Supply, fixing, testing & commissioning of 20 mm bore and 30 meter long hose (high pressure rubber braided hose pipe as per IS:444) and hose reel, (The complete assembly shall be capable of withstanding the hydrostatic test pressure 21 kg/sqcm), for first aid fire fighting conforming to IS : 884, with 180o full swing drum, fixing brackets, 5 mm dia shut off Stainless steel nozzle, connecting directly from the riser through 40 mm dia. MS (Class C) pipe with sockets, elbows, nipples, 40x20 mm reducer, 20 dia pipe, 20 mm dia. hand lever operated isolating ball valve, etc. including providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respects as per drawings and directions of Engineer-in-charge. (MAKE : Newage / Jayshree / Safeguard / Padmini / Getech)

30

-

12477

... More
Providing Stainless steel ISI marked 63 mm. dia. male Instantaneous pattern short branch pipes with 15 mm dia. Nozzle as per IS : 903, suitable for hydrostatic test pressure 21 kg/sqcm and suitable for interconnections to hose pipe coupling as required. (MAKE : Newage / Safeguard / Padmini / Getech)

30

-

3220

... More
Providing ISI marked RRL (IS : 636, type-A) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) suitable for hydrostatic test pressure 21 kg/sqcm, Stainless steel male and female coupling bound and rivetted to hose pipes with copper rivets and copper wire complete as required. (MAKE: Jayshree / Newage / Padmini / Safeguard / Getech)

60

-

7883

... More
Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. (MAKE : Newage / Safeguard / Padmini / Getech)

30

-

950

... More
80 mm dia

6

-

1089

... More
Providing & fixing 100 mm dia dial pressure gauge including making connections with MS pipe complete in all respects. (Make : H Guru / FIBIG)

4

-

920

... More
Providing & fixing UL listed water flow detectors / switches (Vane type) for sprinkler system, shall have sensitivity in the range of 4 to 10 US gallon per minute and static pressure rating of 450 PSI including accessories, junction box, suitable for indoor / outdoor mounting. The detector shall respond to water flow in the specified direction after a preset time delay that is field adjustable, complete as required suitable for fixing on fire pipe including connection for wiring. (Make : System sensor) for 150 mm diameter pipe

1

-

9500

... More
Supply & installation of cast iron body 4 way 63 mm dia male instantaneous inlet coupling complete with inbuilt NRV, cap and chain for fire brigade connection conforming to IS : 904 and making connection with fire fighting pipe or under ground water tank, completing the work in all respect as per the directions of the Engineer-in-charge. (MAKE : Newage / Safeguard / Padmini / Getech)

2

-

20500

... More
Providing and fixing of cast iron body 100 mm dia Draw out connection in Under ground water storage tank with heavy class MS suction pipe of required length, foot valve, suction coupling in conformity with local regulations complete in all respects. (MAKE : Newage / Safeguard / Padmini / Getech)

1

-

10350

... More
Supply, fixing, testing & commissioning of cast iron body and brass/bronze working parts, UL listed installation control valve assembly, suitable for hydrostatic test pressure 21 kg/sqcm, complete with Hydraulic Alarm motor & hydraulically driven mechanical gong bell to sound continuous alarm when sprinkler system activates, butterfly valve, alarm valve, test valve, pressure gauge, emergency releases, pressure switch, 50 mm dia drain valve, flanges, gasket etc. to complete the system as required, as per manufacturers specifications. (MAKE : HD / Tyco / Newage / Globe) 150 mm diameter

1

-

55200

... More
Providing, fixing, testing and commissioning of Sprinkler Annunciation panel for monitoring of required number of flow switches, fabricated out of 16 SWG CRCA sheet , powder coated in approved shade after 7 tank treatment process, with locking arrangement, audio / visual indication of fault and actuation of automatic sprinkler system. The panel shall have fault indication with audible alarm for each zone, indication of fire zone, fire / fault hooter, 2 nos 12 volts 24 AH emergency SMF battery with battery charger trickle cum boost to take complete load of panel and mains supply, indication of low battery voltage, monitoring open circuit, short circuit, earth fault in control cable between panel and flow switches etc. The panel should be suitable for interface for connection to building automation system including all accessories, control wiring complete in all respects as required. (Safeway / Agni Suraksha (ASES) / Daksh / Morley) 4-Zone annunciator panel

1

-

17250

... More
Supply and laying of ISI marked 2 x 1.5 sq mm armoured Copper conductor PVC insulated control cable as per IS 1554 or XPLE insulated as per IS 7098, PVC sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections complete in all respect including supply of clamps, lugs, tape etc complete upto the satisfaction of Engineer-in-charge. (Make : Universal (Satna) / CCI / Nicco / Finolex / Polycab / Skytone)

25

-

138

... More
a) Supply, fixing, testing & commisioning of C.P. bronze / gun metal Sprinklers as per IS : 9972, comprises of 15mm dia conventional pattern, 68oC, glass bulb type sprinklers, UL / FM listed / approved. The installation shall be complete as per the drawings with positioning of sprinklers as per final coordinated plan and requirement of IS : 15105, local fire service & Engineer-in-charge. (MAKE : HD / Tyco / Globe / Newage)Upright sprinkler, Pendant sprinkler

246

-

529

... More
b) Horizontal side wall mounted sprinkler

10

-

1265

... More
Providing and fixing standard fire hose cabinet door frame (900 mm x 1650 mm ) suitable to fit in the duct made of not less than 16 SWG MS sheet having full fronted glass hinged door (5 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words "FIRE HOSE" to be painted on the box.

28

-

6325

... More
Providing and fixing standard fire hose cabinet (900 mm x 1800 mm x 450 mm) indoor type suitable for accomodating internal hydrant, hose reel made of not less than 16 SWG MS sheet having full fronted glass hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos. 15 meter long fire hose pipes, 30 meter long hose reel, branch pipe and hydrant valve as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on suitable raised platform. The words "FIRE HOSE" to be painted on the box.

2

-

9775

... More
Supply, Fixing, Testing & Commissioning of fire authority approved electrical motor driven fire pump, suitable for automatic operation consisting of following : (Main Pump for hydrant and sprinkler system) (MAKE : Kirloskar / Mather + Platt)(a) Horizontally mounted, multi stage, split casing Centrifugal fire pump with operating speed not exceeding 1500 rpm, as per IS:1520 complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 35 meter at the highest and farthest outlet at the specified flow complete with necessary strainers, 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm including bypass arrangement for periodic testing of the working of the pumpset as well as testing of automation with required length and size of MS pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately balanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Squirrel cage, TEFC induction motor as per IS : 325, suitable for 415 V +/- 10%, 3 Phase, synchronous speed 1500 rpm, IP 55 protection and class 'F' insulation, vaccume impregnated windings with heat and moisture resisting varnish for the above pump and flexible coupling with the pump. The motor shall be rated for continuous duty and shall have HP rating necessary to drive the pump at 150% of it's rated discharge at 65% of rated head.(c) Common bed plate of fabricated mild steel channel or cast iron type, coupling, coupling guard ets as required.(d) Suitable vibration clamping arrangement as required. with foundation bolts, anti vibration pads, washers etc. (e) Pressure switch for automatic operation of motor including necessary wiring upto control panel.(f) Necessary Priming arrangement (if required) for the pump including priming tank of suitable capacity, piping of medium class GI pipe, valves, connection etc. complete.Discharge : 1620 liter per minuteHead : 88 meter

1

-

300000

... More
Supply, Fixing, Testing & Commissioning of fire authority approved Diesel Engine driven Fire Pump, suitable for automatic operation consisting of following : (Stand by pump). (Make : Kirloskar / Mather+Platt with Kirlosker / Cummins engine)(a) Horizontally mounted, multi stage, split casing Centrifugal fire pump with operating speed not exceeding 1500 rpm, as per IS:1520 complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 35 meter at the highest and farthest outlet at the specified flow complete with necessary strainers, 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm including bypass arrangement for periodic testing of the working of the pumpset as well as testing of automation with required length and size of MS pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately balanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Water cooled Diesel engine developing suitable BHP for the above pump set, 1500 RPM including engine control panel with manual and automatic starting mechanism, auto/manual selector switch, 3 attemt starting device, timers, relays, push buttons, start/stop in manual mode, 2 nos. SMF lead acid batteries of 12 / 24 V & of 180 AH capacity, battery charger unit with boost & trickle charger, selector switch, 3 mm thick welded steel fabricated Diesel tank for two hours capacity complete with inlet and outlet connections, fuel tubings to the engine of MS C clas, fuel filter, fuel lift pump, oil level indication gauge, residential exhaust silencer, fly wheel, air intake manifold, air cleaner, radiator, radiator fan, lub. oil pressure gauge, filter, cooling water temperature gauge and all other accessories required to complete the system. The diesel engine shall be rated for continuous duty and shall have BHP rating necessary to drive the pump at 150% of it's rated discharge at 65% of rated head.(c) Diesel engine Exhaust system of required length of Class `B' MS pipe of suitable diameter with bends, expansion joints including providing suitable supporting arrangements at suitable intervals, with glass wool insulation 50 mm thick on all sides of exhaust pipe and silencer, with chicken mesh wrapping and 1 mm thick aluminium sheet cladding complete as required. (d) Supply, installation, testing and commissioning of AMF autostart complete with necessary relays like no volt relay, over voltage and low voltage relays, contactors, timer, pressure switch etc. as required for the auto start of the diesel engine in case of power failure complete with all accessories, wiring & cabling including connection to diesel engine complete as required all in conformity with the local Fire regulations. The diesel engine driven fire pump will start automatically in the event of pressure drop beyond preset limit or on mains failure or failure of electric driven pumps to start.(e) Common bed plate of fabricated mild steel channel or cast iron type, coupling, coupling guard ets as required.(f) Suitable vibration clamping arrangement as required. with foundation bolts, anti vibration pads, washers etc. (Civil work shall be excluded from Vendor scope)(g) Pressure switch for automatic operation of motor including necessary wiring upto control panel.(h) Necessary Priming arrangement (if required) for the pump including priming tank of suitable capacity, piping of medium class GI pipe, valves, connection etc. complete.Discharge : 1620 liter per minuteHead : 88 meter

1

-

488750

... More
Supply, Fixing, Testing & Commissioning of fire authority approved electrical motor driven fire pump, suitable for automatic operation consisting of following : (JOCKEY PUMP). (MAKE : Kirloskar/Mather + Platt)(a) Horizontally mounted, end suction type, Centrifugal fire pump with operating speed of 2900 rpm, as per IS:1520 complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 35 meter at the highest and farthest outlet at the specified flow complete with necessary strainers , 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm including bypass arrangement for periodic testing of the working of the pumpset as well as testing of automation with required length and size of MS pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately balanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Squirrel cage, TEFC induction motor as per IS : 325, suitable for 415 V +/- 10%, 3 Phase, synchronous speed 2900 rpm, IP 55 protection and class 'F' insulation, vaccume impregnated windings with heat and moisture resisting varnish for the above pump and flexible coupling with the pump. The motor shall be rated for continuous duty and shall have HP rating necessary to drive the pump at 150% of it's rated discharge at 65% of rated head.(c) Common bed plate of fabricated mild steel channel or cast iron type, coupling, coupling guard ets as required.(d) Suitable vibration clamping arrangement as required. with foundation bolts, anti vibration pads, washers etc. (Civil work shall be excluded from Vendor scope)(e) Pressure switchs (for both upper and lower levels) for automatic operation of motor including necessary wiring upto control panel.(f) Necessary Priming arrangement (if required) for the pump including priming tank of suitable capacity, piping of medium class GI pipe, valves, connection etc. complete.Discharge : 180 liter per minuteHead : 88 meter

1

-

120750

... More
Design, manufacture, supply, storing, inspection, handling, assembling, installation in correct alignment, position, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type Electrical Control Panel for fire fighting pumps, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable required. All Outgoiung MCCB's shall be microprocessor based, motor protection category, current limiting type. All MCCB's shall be Ics = 100% Icu, with rotary handle. All TP MCCB shall be with heavy duty solid isolable neutral link. The panel shall be provided with suitable relays including contactors, star-delta / DOL starters for all pumps as applicable, 3 nos. phase indicating lamps, ammeter, voltmeter, selector switches, CT's, PT's, protective fuses, indicating lights for incoming and outgoing feeders, 1 Set of indication lamps for mains ON/OFF/Trip conditions, auxillary switches, dry suction cut off, single phase preventer etc. The under voltage release and no volt coil shall not be provided in the MCCB's.The panel shall be provided with interlocking arrangement between electric motor driven and diesel engine driven pumps so that only one pump can operate at one time and in case of any failure in electric motor driven pump the diesel engine driven pump shall operate automatically. The system controller should be capable to control operation of various pumps in sequence as per standards consisting of relays, timers, sensors, annunciation window for fault indication complete in all respects.Provisions shall be made for providing potential free contacts to all pump starters for connection to building automation system / Fire alarm control panel. The rates shall include necessary interconnecting armoured copper control cables of suitable sizes within the panel and from panel to various motors and engines, pressure switches, level switches of water tanks, cable trays etc required to complete the entire installation upto the satisfaction of engg-in-charge.The fault withstanding capacity of panel shall be 35 KA rms for 1 sec.Following Fire fighting pumps shall have to be controlled - 1 set of Electric motor driven hydrant pump1 set of diesel engine driven stand by pump1 set of electric motor driven jockey pump (Switchgears Make : ABB / L&T / Siemens / Schneider / Legrand)(Panel Make : Tricolite / Advance (Delhi) / Ambit / Adlec / Mile stone / ASES (Agni Suraksha)Incomer : 200 AMP FP MCCB (35 KA) with flush mounting square CT operated ammeter with selector switch, Voltmeter with selector switch, protective fuses and phase indicating lamps.Bus Bar : 200 AMP TPN, 415 volt, 3 phase, 4 wire, 50 HZ electrolitic high conductivity Copper with SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clips on shrouds for joints. The current density of copper bus bar shall not exceed 1.25 amp/sqmm.Outgoings : 1 nos. 160 AMP TPN MCCB (35 KA) with star delta starter of suitable HP for main fire pump with over load protection, single phase preventor complete for automatic operation, selector switch for local/remote, auto/manual/off operation, with CT operated ammeter with selector switch and indication lamps for "On" "Off" and "Trip" mounted on the cubicle door.1 nos. 63 AMP TPN MCCB (35 KA) with star delta starter of suitable HP for jockey pump with over load protection, single phase preventor complete for automatic operation, selector switch for local/remote, auto/manual/off operation, with CT operated ammeter with selector switch and indication lamps for "On" "Off" and "Trip" mounted on the cubicle door.1 nos. 32 AMP TPN MCB (10 KA) as spare1 nos. 32 AMP TPN MCB (10 KA) as spare1 nos. 32 AMP TPN MCB (10 KA) as spare

1

-

230000

... More
a) Providing and laying of ISI marked Aluminium conductor, XLPE insulated, armoured, served, sheathed Cable 1100 V grade with terminal joints by palm or pin type cable sockets (lugs), insulating with tapes, double compression type brass and nickle plated compression glands. On surface, the cable run shall be on MS cable trey or fixed on M.S. clamps etc.of suitable size or as directed by engineer-in- charge, complete in all respects. The armouring shall be properly connected with the earth conductor by clamps etc. (Make : Universal (Satna) / CCI / Nicco / Finolex / Polycab / Skytone / RR) 10 sqmm 4 core

25

-

285

... More
b) 50 sqmm 3 1/2 core

25

-

460

... More
a) Supply and erection of Perforated type cable trays made out of prefabricated Galvanized sheet steel including tees, bends, crossings, reducers, couplings to be laid in cable trenches, over head on wall or hanged from ceiling including all neccessary supports, brackets at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts & bolts complete in all respects. The support for 300mm wide cable tray will be by 32 x 32 x 5 mm MS angle, for 150mm wide cable tray will be by 25 x 25 x 4 mm MS angle. 300 mm (W) X 35 mm (H) X 1.5 mm (T)

10

-

860

... More
b) 150 mm (W) X 35 mm (H) X 1.5 mm (T)

10

-

625

... More
Supply & burrying of 600mmx600mmx6mm G.I. plate, vertically for earthing with its top at least 3m below ground level complete 20mm dia. G.I.pipe and funnel for watering and 300mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer-in-charge complete in all respect .

2

-

5570

... More
Supply & Fixing of 32mm x 6 mm G.I. strip for earthing purpose to be laid on surface or below ground as required at site.

25

-

150

... More
FIRE DETECTION AND ALARM SYSTEM Providing, fixing, testing and commissioning of UL / FM / EN / VDS listed / approved conventional automatic fire Alarm detectors - (MAKE : System Sensor / Apollo / Edward / Bosch) (a) Optical/Photoelectric type smoke detectors of photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LED's) "Blink - green" in stand by and "Steady - red" in alarm complete in all respects with base as required.

34

-

2777

... More
(b) Fixed cum rate of rise temprature type heat detectors, 12 / 24 volt D.C., visual alarm indicators (LED's) "Blink - green" in stand by and "Steady - red" in alarm complete in all respects with base as required.

4

-

2777

... More
Providing, fixing, testing and commissioning of resettable type manual call points break glass type housed in sheet steel / Polymer housing in surface/recess including making connections with wires complete in all respects and as per specifications. The manual call point should have an indicator, which should "blink" in stand by condition. (Make : Agni Suraksha (ASES), Safeway, Honeywell)

30

-

805

... More
Providing, fixing, testing and commissioning of electronic hooters with LMT (hooters shall also be able to work as public address system sounders) housed in sheet steel / Polymer housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete in all respects and as per specifications. (Make : Agni Suraksha (ASES), Safeway, Honeywell)

30

-

2300

... More
Providing,fixing,testing and commissioning of response indicators with dual LED suitable for operation on 12/24 volts D.C., sheet steel / Polymer housing suitable for surface/recess mounting including making connections with wires complete in all respects. (Make : Agni Suraksha (ASES), Safeway, Honeywell)

30

-

170

... More
Providing, fixing, testing and commissioning of fire alarm main control and indicating panel, conventional microprocessor based (fire and fault indication only to be repeated to the fire repeater panel through NO / NC) to monitor all detectors / devices / zones as per the case, pulser, timer for dual stage alarm facility complete with indicators, floor selector switches, stand by SMF lead acid battery (suitable for 48 hours normal operation & after that min. 30 minutes for full load operation), battery charger unit with boost & trickle charger, battery box, connections to building automation system / Fire fighting pump panel etc. complete in all respect and as per specifications and requirements. The panel shall have facility of automatic dialling to 5 telephone numbers in case of alarm. The main control panel should give a distinct visual signal of the isolation of zone from the local indication panel. If all the zones at the local panel are isolated or if the fuse of the LCP gets blown, it should result in an open circuit fault indication at the Main Panel. Each zone should have provision of activation of hooter. (Make : Agni Suraksha (ASES), Safeway, Honeywell) 16-Zone main control panel

2

-

95000

... More
Providing, installing, testing and commissioning of repeater panel suitable for common fire / fault indication of main Fire Alarm panels with sounder, stand by SMF lead acid battery, battery charger, battery box, LCD alpha numeric character display with accept / reset buttons for alarm. The panel shall be connected to the main fire alarm panel. (Make : Agni Suraksha (ASES), Safeway, Honeywell) 4-Zone repeater panel

1

-

20000

... More
Supplying, receiving, storing, handling, fixing of PVC insulated Copper Conductor Armoured Cable (Make : Polycab/Rallision/Skytone 2x1.5 sqmm

750

-

138

... More
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 300 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. (Make : Glow light / Legrand / Autoglow / Pierlite / Agni Suraksha-ASES)

30

-

800

... More
RAIN WATER HARVESTING Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depthPipes 80 mm to 300 mm diameter1.50 m to 3.00 m depth Si No: 2.10.1.2

285

-

208.3

... More
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. A) 250 mm. dia. RCC Pipes Si No: 19.6.3

75

-

468.6

... More
b) 300 mm. dia. RCC Pipes Si No: 19.6.4

225

-

506.35

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design Si No: 19.3.2

300

-

456.45

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line Si No: 19.7.1.1

19

-

8507

... More
Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 Si No: 19.8.1.1

9

-

5638.2

... More
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. Si No: 19.16

38

-

311.6

... More
a) Inside size 60x60 cm & 90 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. Si No: A.R.08

30

-

6500

... More
DESILTING CHAMBER Earth work In excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as per as 10 sq.m on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil Si No: 2.6.1

9

-

155.6

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering , lead up to 50 m and lift up to 1.5m. Si No: 2.25

10.6

-

112.4

... More
Extra for every additional lift of 1.5 m or part there of in: All kinds of soil. Si No: 2.26.1

13.8

-

46.25

... More
Providing and laying in position cement cncrete of specified grade excluding the cost of centring and shuttering - all work upto plinth level. 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Si No: 4.1.8

1.8

-

4301.15

... More
1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 40 mm nominal size) Si No: 4.1.4

0.1

-

5335.25

... More
Centring and shuttering including strutting, proppintg etc. and removal of form for: Suspended floors,roofs, landings, balconies and access platform. Si No: 5.9.3

4

-

401.65

... More
Edges of slabs and breaks in floors and walls,Under 20 cm wide Si No: 5.9.16.1

12

-

116.4

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo Mechanically Treated bars. Si No: 5.22.6

212

-

68.1

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements excluding the cost of centring, shuttering, l finishing and reinforcement. including Admixtures in recomended proportions. (as per IS 9103) to accelerate, retard setting of concrete improve work ability without impairing strength and durability as per directio of Engineer in charge M-25 grade reinforced cement concrete. by using 410kg. of cement per cum. of concrete. All work up to floor V level Si No: 5.33

1.8

-

6296.15

... More
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) Si No: 6.1.1

15.7

-

4918.65

... More
12 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand). Si No: 13.1.1

39.6

-

163.35

... More
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete: 200 mm diameter Si No: 19.1.3

6

-

462.15

... More
Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. In all kind of soil upto 1.5m depth Si No: 2.6.1

29.4

-

155.6

... More
In all kind of soil upto 1.5m to 3.0m. depth Si No: 2.6.1&2.26

29.4

-

201.85

... More
In all kind of soil upto 3.0m to 4.5m. depth Si No: 2.6.1&2.26

29.4

-

248.1

... More
Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. Si No: 4.1.3

1.9

-

5466.3

... More
Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. Si No: 6.1.1

39.8

-

4918.65

... More
Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. Si No: 5.3

2.7

-

6778.2

... More
Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. Si No: 5.22.1

320

-

64.95

... More
15mm cement plaster on rough side of single or half brick wall mix 1:4 (1 cement : 4 coarse sand) Si No: 13.5.1

92.4

-

200.05

... More
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar Si No: 19.15.1

24

-

275.5

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter Si No: 19.19.2.2

4

-

909.25

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually. Si No: 24.1.1.1

50

-

407.1

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia Si No: 24.4.2

50

-

528.95

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Si No: 24.5

4.9

-

504.15

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Si No: 24.6

4.9

-

910.65

... More
Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. Si No: 24.7

4.9

-

852.6

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. Si No: 24.8

2

-

987.85

... More
Constructing brick masonry open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: Drain 300 wide average. Depth 45 cm with R.C.C. Slab Si No: A.R.09

300

-

3280

... More
Drain 450 wide average. Depth 45 cm with R.C.C. Slab Si No: A.R.10

75

-

3650

... More
ELECTRICAL WORKS Wiring points for light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.

2604

-

446

... More
Same as item No.(1) but for two way light Points.

32

-

579

... More
Same as item No.(1) but for fan and light duty exhaust fan.

1014

-

530

... More
Same as item No.(1) but for 5 Amp plug point

1100

-

240

... More
Same as item No.(1) but for call bell point , Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points.

120

-

417

... More
Addition for light / fan points with modular type switch in place of piono type switch.

3618

-

109

... More
Addition for 2 way light points with modular type switch in place of piono type switch.

32

-

198

... More
Addition for plug points with modular type switch in place of piono type switch.

1100

-

188

... More
Addition for call bell points with modular type switch in place of piono type switch.

120

-

122

... More
Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor : cable as earth contunity wire etc. complete in all respects.

11070

-

132

... More
Supply and wiring of submain 2 number 6 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FR PVC insulated multistranded copper conductor : cable as earth contunity wire etc. complete in all respects.

6210

-

184

... More
Supply and wiring of submain 2 number 16 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 10.0 sqmm FR PVC insulated multistranded copper conductor : cable as earth contunity wire etc. complete in all respects.

60

-

415

... More
Supply and wiring of submain 4 number 6 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduit along with two numbers 4sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.

3450

-

415

... More
Supply and wiring of submain 4 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduit along with two numbers 6 sqmm FR PVC insulated multistranded copper conductor : cable as earth contunity wire etc. complete in all respects.

175

-

504

... More
Supply and wiring of submain 4 number 16 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 40mm dia PVC conduit along with two numbers 10 sqmm FR PVC insulated multistranded copper conductor : cable as earth contunity wire etc. complete in all respects.

30

-

824

... More
Supply fixing and concealing of 20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . ( for Telephone/ TV points)

7000

-

44

... More
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.

10

-

118

... More
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring : conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.

254

-

112

... More
Supply & fixing of ceiling fitting fixed on matching M.D.F.E.G. Board base including connections with existing outlet. The base of ceiling fitting shall be fabircated from 22 gauge CRCA sheet in square shape finished with black matt surface complete with 3mm thick export quality acrylic moulded cover and heavy duty brass holder of Kinial/or any other approved make complete in all respects Category A

204

-

517

... More
a) Supply & fixing of factory wired, Box/ Channel type T-5 energy saver with powder coated reflector & with end cover for following fluorescent tube including tubes etc. complete as required. 1 x 28 Watt.

188

-

1890

... More
b) 2 x 28 Watt.

4

-

2861

... More
S/F of water tight, oblong bulk head fitting of approved make omplete with prismatic glass holder, rubber gasket, G.I. guard etc. complete in all respects.

56

-

316

... More
a) Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work. 600x480x200 mm. size

153

-

433

... More
b) 480x480x200 mm. size

14

-

334

... More
a) Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followed by two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work. 600x480x200 mm. size

153

-

1319

... More
b) 480x480x200 mm. size

14

-

1199

... More
a) Supply and fixing of flush/surface mounting distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. 4 Way SPN

12

-

1129

... More
b) 12 Way SPN

2

-

1691

... More
c) 6 Way TPN

125

-

3376

... More
Supply and fixing of 240 volts 'L' series miniature circuit breaker 6 Amp. To 32 Amp. (10 K A ) in existing MCB, DB complete with connections as required. 6 - 32 amps. (Legrand Lexic)

1448

-

210

... More
a) Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 16 Amp. DP MCB (10 KA) (Legrand Lexic )

12

-

635

... More
b) 63 Amp. DP MCB (10 KA) (Legrand Lexic )

2

-

1019

... More
c) 32 Amp. 4P MCB (10 KA) (Legrand Lexic )

120

-

1367

... More
d) 40 Amp. 4P MCB (10 KA) (Legrand Lexic )

5

-

2011

... More
Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T & P etc required for proper completion of work.

650

-

552

... More
Supply & fixing of Sheet Steel Enclosure Surface/ Flush Mounting fitted With 20/32 Amp. 2Pin and earth metal clad scraping earth plug and socket complete in all respects as per direction and satisfaction of engineer-in-charge.

360

-

664

... More
Supply and fixing Single Pole MCBS Blanking Plate complete in all respects.

1116

-

7

... More
Supply and burying of 40 mm dia x 4.5 metres long G.I Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG G.I wire in G.I Pipe up to appron ( and from appron to switch board the cost of G.I wire and pipe will be extra) upto switch board, 30 cm square C.I box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of Engineer in charge complete in all respects as per drawing.

7

-

3357

... More
Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.

12

-

4339

... More
Supply and burying of 600mm X 600mm X 3 mm copper Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I pipe and funnel for watering and one earthing lead of one no. 8 SWG copper wire in 15 mm dia G.I pipe up to switch board ( from appron to switch board the cost of G.I pipe and copper wire will be extra) 30 cm square C.I frame with hinged cover masonry housing alternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of Engineer in charge complete in all respects.

4

-

8720

... More
Supply and burying earth electrode for lighting conductor of 600mm*600m*6.0mm G.I plate vertically for earthing with its top at least 3 meters below ground level complete with 20mm dia G.I pipe for watering funnel, 30cm square C.I frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects.

6

-

3748

... More
Supply and fixing of horizontal air termination (roof condutor) of 25mm*3mm G.I strip, G.I clamps on surface complete in all respects as approved by Engineer-in-charge.

350

-

137

... More
Supply and fixing of vertical air termination final rod comprising of 300mm long x 25 dia. Copper rod with one pointed prong and 100mm dia x 3 mm thick base plate etc. complete in all respects.

2

-

1155

... More
Supply and fixing of vertical down conductor of 32mm x 6mm G.I. strip etc. on approved clamp on surface for lightning conductor complete in all respect.(for five and above storeyed building)

315

-

242

... More
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.

375

-

75

... More
Supply and Laying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects..

70

-

896

... More
Supply and fixing of testing joint of G.I. strip 32mm x 6mm and 150mm long with G.I. bolts and nut etc. complete in all respects.

46

-

48

... More
Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.

120

-

144

... More
Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side.

160

-

154

... More
Supply and Laying of 40mm X 5 mm G.I strip from earth electrode directly in the ground as required complete in all respects including testing joint of G.I strip 40mm x 5 mm and 150mm long with G.I bolts and nuts etc. complete in all respects

105

-

182

... More
a) Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.as per direction of Engineer-Incharge.complete in all respect The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 300 sqmm 3.5 core

490

-

2124

... More
b)185 sqmm 3.5 core

315

-

1428

... More
c) 70 sqmm 3.5 core

50

-

730

... More
d) 50 sqmm 3.5 core

250

-

595

... More
e) 35 sqmm 3.5 core

385

-

408

... More
f) 16 sqmm 4 core

405

-

345

... More
g) 10 sqmm 4 core

140

-

296

... More
h) 10 sqmm 2 core

280

-

252

... More
i) 6 sqmm 2 core

210

-

239

... More
a) Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. 300 sqmm 3.5 core

12

-

429

... More
b)185 sqmm 3.5 core

14

-

281

... More
c) 70 sqmm 3.5 core

2

-

151

... More
d) 50 sqmm 3.5 core

4

-

151

... More
e) 35 sqmm 3.5 core

50

-

139

... More
f) 16 sqmm 4 core

14

-

90

... More
g) 10 sqmm 4 core

24

-

72

... More
Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 300 Sq.mm

36

-

486

... More
b)185 Sq.mm

42

-

256

... More
c)150 Sq.mm

12

-

178

... More
d)95 Sq.mm

14

-

109

... More
e)70 Sq.mm

6

-

80

... More
f)50 Sq.mm

12

-

51

... More
g)35 Sq.mm

2

-

29

... More
h)25 Sq.mm

4

-

26

... More
i)16 Sq.mm

56

-

19

... More
k)10 Sq.mm

96

-

18

... More
46Supply and Fixing of H.P.S.V. post top lantern, integral with control gearetc suitable for 70 watt Sodium Vapour lamp complete with 70 watt S.V. lamo etc. complete in all respect

27

-

3403

... More
a)S/F of M.S. pipe (Class 'B'- IS : 1239) pole suitable for fixing 70 watt. HPSV post top including 4 pole cable junction box with 5 Amp. rewireable fuse fitting and 5 Amp. switch on laminated cover and M.S. box complete with water tight cover including Masonary/PCC (1:3:6) work for erecting the pole and 450x450x450mm base above ground and 2x4sqmm Aluminium wire from cable box to lamp for connection including painting the pole by an approved shade on primer coats and necessary reducers on thetop of pole for fixing of post top lantern. The work shall be complete as required up to the satisfaction of Engg.-in-Charge. 65mm dia 4m long (3m above ground and 1 m below ground).

27

-

2155

... More
48Supplying and Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.

4

-

281

... More
49Supplying & Laying of 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality

8

-

2319

... More
50Supply and fixing danger board fabricated from 10 gauge MS sheet as per IE Rules

4

-

62

... More
51S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T & P for proper completion of work.

4

-

218

... More
52Supply and fixing of fire extinguisher, ABC Type 4.00 kg. caoacity (ISI Marked : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

4

-

8032

... More
a)Supply and laying of 3 core standered Aluminium conductor XLPE (Crosslinked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part II with latest amendments) II KV grade at a depth of 900 mm below ground level over cushion of 100 mm thick fine river sand all around and protected with well brunt bricks on sides and on top put across. The armouring of cable shal be properly connected with earth conductor by clamps etc. 240 sq. mm 3 core

75

-

2255

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 240 sq. mm.

4

-

7007

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 240 sq. mm.

1

-

9400

... More
Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mmMain L.T. Panel Incoming :One (1) No 1250 Amp. 4 pole ACB of 50 KA Breaking capacity MDO Type Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-1250A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar :One (1) No. 1250 A, TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.630 Amps TP MCCB of 36 KA (Ics=Icu) Breaking Capacity - 1 No.400 Amps TP MCCB of 36 KA (Ics=Icu) Breaking Capacity - 2 No.320Amps TP MCCB of 36 KA (Ics=Icu) Breaking Capacity-2 No.200Amps TP MCCB of 36 KA (Ics=Icu) Breaking Capacity-1 No.63Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity-1 No.Three Phase Energy Meter-1 No.630 Amps TP MCCB of 36 KA (Ics=Icu) Breaking Capacity - 1 No. Spare400 Amps TP MCCB of 36 KA (Ics=Icu) Breaking Capacity- 1No. Spare 320 Amps TP MCCB of 36 KA (Ics=Icu) Breaking Capacity- 1No. Spare

1

-

516100

... More
Common Services Panel Incoming :One (1) No 320 Amp. 4P MCCB of 36 KA Breaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-320A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar :One (1) No. 320 Amp.TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.125Amps TP MCCB of 36 KA (Ics=Icu) Breaking Capacity-2 No.100Amps TP MCCB of 25 KA (Ics=Icu) Breaking Capacity-1 No.63 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 3 No40 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 1 No125Amps TP MCCB of 36 KA (Ics=Icu) Breaking Capacity- 1 No Spare100Amps TP MCCB of 25 KA (Ics=Icu) Breaking Capacity- 1 No Spare63 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 1 No Spare

1

-

126600

... More
Elevator Panel 1 & 2Incoming :One (1) No 125 Amp. TPN MCCBMetering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-125A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar :One (1) No. 200 A, TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.63 Amps TP MCCB of 25 KA (Ics=Icu) Breaking Capacity 2 No63 Amps DP MCB of 10 KA (Ics=Icu) Breaking Capacity 1 No 63 Amps TP MCCB of 25 KA (Ics=Icu) Breaking Capacity 1 No Spare63 Amps DP MCB of 10 KA (Ics=Icu) Breaking Capacity 1 No Spare

2

-

64600

... More
CAPACITOR PANEL SITC APFC Panel of 150 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static 12.5,25 , 50 KVAR capacitors (without oil) in tier formation complete with following TPNMCCB as incomer of the panel, 8 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated.Incoming400 Amps., 35 KA (ICS = 100% ICU) breaking capacity, 415 Volt, TPN MCCB with continuously adjustable thermal magnetic release - 1 Nos.OUT GOING a) 40 Amps., 10 KA (ICS = 100% ICU) breaking capacity, 415 Volt, TPN MCB with continuously adjustable thermal magnetic release - 4Nos.b) 63 Amps., 10 KA (ICS = 100% ICU) breaking capacity, 415 Volt, TPN MCB with continuously adjustable thermal magnetic release - 2 Nos.c) 160 Amps., 25KA (ICS = 100% ICU) breaking capacity, 415 Volt, TPN MCCB with continuously adjustable thermal magnetic release - 1No.

1

-

168177

... More
STREET FEEDER PILLER Supplying assembling erecting connecting, testing and commissioning of sizes of 3.15mm thick sheet metal enclosed outdoor type feeder pillars with water proof dust and vermin proof hinged and lockable doors including rain protection cover complete with interconnections, with aluminium wire, tapes, bonding to earth and painting complete as required. The feeder pillar shall consist of MCCB as incoming and MCB as outgoing. (Note : This panel shall be a FRONT operated, with cable entry from the top/bottom. The fault with standing capacity shall be 25 KA. Earth busbar shall be part of the L.T. Panel). INCOMING1No. Of 63 Amps TPN MCB of 10 KA service breaking capacity and 63 Amp trip setting.BUS BAR1 Set of 63 Amps TPN Aluminium Bus Bars of suitable length and of cross section . Bus bar shall be insulated by heat shrinkable sleaves & clip on shrouds for joints. Bus bar shall be designed to with stand a fault level of 10 KA at 415 volts.3Nos. Phase indicating lamp each lamp shall have one toggle switch .OUTCOMING32Amp DP MCB (10kA) - 4 Nos. 32Amp DP MCB (10kA) - 2 No Spare

1

-

45000

... More
MAIN DISTRIBUTION BOARD a) Supplying, installation, testing and commissioning of surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly phosphatized and powder painted, inclusive of 100 Amps tinned copper busbar, common neutral link, earth bar, din bar for mounting MCB's, detachable gland/ knock out plate, and with 100 Amps, MCCB as incomer interconnection between incomer MCCB and busbars of following ways :MAIN DISTRIBUTION BOARD-1(Ist to XIIth Floor)4Way Vertical Type Distribution BoardIncomer :-100Amp. TPN. MCCB Outgoing32Amp. TP. MCB -6 Nos.

12

-

26000

... More
b) MAIN DISTRIBUTION BOARD-2(Ist to XIIth Floor)4Way Vertical Type Distribution BoardIncomer :-100Amp. TPN. MCCB Outgoing32Amp. TP. MCB -4 Nos.

12

-

23700

... More
c) MAIN DISTRIBUTION BOARD-1(Stilt Floor)4Way Vertical Type Distribution BoardIncomer :-63Amp. TPN. MCB Outgoing40Amp. TP. MCB -2 Nos.

1

-

16600

... More
d) MAIN DISTRIBUTION BOARD-1(Basement Floor)4Way Vertical Type Distribution BoardIncomer :-100Amp. TPN. MCCB Outgoing40Amp. TP. MCB -2 Nos.

1

-

24500

... More
e) EM. MAIN DISTRIBUTION BOARD(Corridor Lighting)12Way Vertical Type Distribution BoardIncomer :-40Amp. TPN. MCB Outgoing16 Amp. DP. MCB -12 Nos.

1

-

21600

... More
f) EM. MAIN DISTRIBUTION BOARD(Flats-Ist to XIIth Floor) 12Way Vertical Type Distribution Board Incomer :-40Amp. TPN. MCB Outgoing 16 Amp. DP. MCB -10 Nos.

12

-

20100

... More
Supply and erection of TPN Rising Mains complete with top end cover plate etc. on angle iron wall brackets,complete in all respects. 315 Amps

67

-

8258

... More
400 Amps

67

-

9512

... More
600 Amps

25

-

13182

... More
Supply and erection of 32 TPN tap off box on rising mains complete with HRC fuses etc. complete in all respects.

12

-

4683

... More
Supply and erection of 100 TPN tap off box on rising mains complete with HRC fuses etc. complete in all respects.

24

-

8658

... More
Supply and erection of incoming adopter box for Mounting 315 Amps TPN CFS Unit including connectors of required capacity on to the rising mains complete in all respects.

1

-

7592

... More
Supply and erection of incoming adopter box for Mounting 400 Amps TPN CFS Unit including connectors of required capacity on to the rising mains complete in all respects.

1

-

9000

... More
Supply and erection of incoming adopter box for Mounting 400 Amps TPN CFS Unit including connectors of required capacity on to the rising mains complete in all respects.

1

-

12285

... More
S/F MODULAR BOXES, BASE & COVER PLATE :- Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm)

572

-

159

... More
a) S/F MODULAR TYPE SWITCH / SOCKET :- Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket outlet

284

-

92

... More
b) TV antenna socket outlet

288

-

94

... More
Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair

2450

-

17

... More
Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

2600

-

23

... More
Providing & Fixing of G. I. TV / Tel junction Box suitable for modular plate type switches (Approx size : 200 x 75 x 50 mm) complete in all respect with cover plate, grid plate, screws, blank plates etc as required. (Make : same as selected modular swith make)

240

-

500

... More
S/f of 10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same

24

-

5000

... More
600mm width X 50mm depth X2mm thickness

60

-

1338

... More
Electronic Energy Meters and Revenue Collection System Supply, installation, testing and commissioning of 3 phase, 4 wire, 50 Hz, dual register, pre paid type electronic energy meters (As per IS : 15884 - 2010) and revenue collection system with key pad technology along with home display / freedom units having LCD display, lithium battery with inbuilt facility of tripping and resetting of over loading in case of D G power at preset level, provision of change of tarrif as per customer's requirements and as per manufacturers specifications. The Meter should have inbuild disconnect switches as per BIS requirement with over load and low balance alarm facility. The cost will also include common meter reading instrument. The meter should be capable for full or partial backup,. For freedom units the 3 pair flat telephone cable shall run from meter to each unit. The system will include Supply, installation, testing and commissioning of DG sensing switch mode power supply unit with discrimination receivers for sensing of DG (SMPS and necessary lengths of PVC insulated armoured copper conductor 2x2.5 sq mm control wiring for DG power registration in electronic meters. The control wiring shall run between D G panel to each block seperately. The control wiring shall be connected to each meter. OR, Supply, installation, testing and commissioning of mains sensing power line carrier based source discrimination receivers of sensing of mains of suitable MVA rating. (LINE INJECTOR) The system will include necessary vending software and data base designing, one set of Intel Core 2 Duo level or higher PC with 1 GB RAM and 500 GB HDD of HP/Dell/Samsung make with laser printer and token printer with serial port, UPS of 500 VA with 20 minute back up complete in all respects for full functioning of system and ready for collection of revenues. The charges will include for necessary training of vending system to operator and customers. (Meter & system Make : Secure-Liberty) .

120

-

12150

... More
Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cutting and making good the walls & floors as per requirement. 150mm

30

-

650

... More
Supply and erection of AC 1200/1400 mm Sweep, 230/250 Volts, 50 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required

10

-

1950

... More
S/f of Automatic Changeover cum circuit Breaker (Single Phase) with load ristriction of 1Kw on generator supply & auto reset facility conplete on all request.

120

-

2100

... More
TRANSFORMER (750 KVA )Supply, storing, inspection, handling, assembling, installing in correct alligned position effecting proper connections, testing & commissioning of Outdoor mounted type 11KV/433V Transfomer (as per IS: 2026), 3 phase, 5% impedance at 75 degree C, Dyn 11 vector group, 50 cycles, (ONAN) oil immersed naturally cooled, step down, double copper wound, continuous duty, temperature rise 50/55 degree C and other standard accessories as required including followings:a) Cable Termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side.b) Cable Termination box with disconnecting facility for required nos. LT cable at LT side.c) Off Load Changer +5 % To - 10% @ 2.5 %d) Bi directional rollerse) Oil Conservator with drain valvef) earthing terminals.g) double diaphragm explosion venth) Radiator with top & bottom shut off valve.i) First filling of oil including make up fill.j) Silica gel breather with oil seal.k) Rating and Diagram plate.l) Air release plug.m) Buchhotz relay with alarm & shut off valve.n) Winding temperature indicator (WT1) with alarmo) Oil temperature indicator (OTI) with alarmp) Magenalic oil level gauge.r) Marshalling box.The work shall be complete in all respects up to the satisfaction of Engg-in-charge.750 KVA

1

-

1077761

... More
H.T. PANEL (11KV) ( LOCATED IN METER ROOM) Design, manufacturing, testing at works, supply of HT Panel as per specification and comprising of the following :- INCOMER/OUTGOING PANEL 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, vertical isolation,vermin proof,fully interlocked horizontal drawout type having double isolation. Manually and motor operated, spring charged( release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indicator. 630 amp air insulated but encapsulated,PVC insulated Copper bus bars. C.T. chamber with C.T.'s 75/5. 15 VA burden for protection (class 5P 10). Following protection shall be provided: 1 Nos IDMT relay with instantaneous 2 nos. over currrent (50, 50 N) element and 1 no. instantaneous earth fault element(50-50N).(O/C setting 50%-200% and E/F setting 20%-80%) All wiring necessary for the above including inter-connections. The size of the conductor should not be less than 2.5 sq. mm. Copper wire where required. Test terminal block, fuses/2A SPMCB , circuit labels,set of phase, indication lamps etc. as per standard practise as under. Red - Breaker close (ON) Green - Breaker open (OFF) Amber - auto trip Clear - trip circuit healthy white - 3 nos. one per phase Blue spring charged Control :- T-N-C (Trip, Neutral. Close) breaker control switch with indication arrangement. Terminal boxes with single gland trifucating cable box suitable for 11 KV Aluminium XLPE (E) cable of size 3C x 240 Sq. mm. for incoming/outgoing breaker. HT Danger Plate.(as per IS specification) 2 Runs of 65 X 8 mm earth bus shall be provided for the full length of the panel. Power Pack, Battery power pack shall be rated for minimum five (5) trippings. For DC power one no. source selector switch to be incorporated i.e. one source from power pack and other from outside. Necessary D.C. supply healthy indication lamp (White Colour), switch with alarm. Surge supressor as required. DC Voltmeter, 0-30 Volt, Digital type. HT Panel switchboard complete with all interconnections, labels, wiring etc, complete as described above in item nos.A and B and as per specifications.

1

-

418455

... More
(a) Supply and Installation of 125 KVA, 415 Volts DG Set with AMF Control Panel comprising of Cummins make engine model 6BTAA5.9G3 developing 154 BHP Coupled to 125KVA, 415V, Stamford make alternator mounted on a common base frame, complete with Manual Control Panel(b) Fuel tank (Inbuilt)(b)  Batteries & Leads.(c)   Residential Silencer.(d)  First fill of lube oil.(e) AVM Pads.(f) Acoustic enclosure Note : Foundation work for Diesel Generator is not included in Electrical works it will come on Civil work.(b) Fuel tank (Inbuilt)(b)  Batteries & Leads.(c)   Residential Silencer.(d)  First fill of lube oil.(e) AVM Pads.(f) Acoustic enclosure Note : Foundation work for Diesel Generator is not included in Electrical works it will come on Civil work.

1

-

1128414

... More
Lift Design supply, install resting & commissioning 10 passenger lift, speed 1.5meter/sec. lift with single speed motor 415 vo;ts, 3 phase. AC 50 Hz supply floor with AC carable voltage & variable freqency drive (VVVF drive) complete with all standard assessories, simplex autometic & manual dual controlled operation with/without attendent, centre opening door drive (electric motor driven machenism), sliding stainless steel doors, (ARD) system, 3D infra red sensor in full height of door & built in announcing system without handset (04 Nos. one each in car, machine room & near Ground floor landing door) complete all as specifiedof CPWD approved make.

4

-

2720000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.