Ghaziabad Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Ghaziabad Development Authority - GDA Tender

Works
Civil And Construction
Eprocure
Opening Date20 Nov 2020
Closing Date7 Dec 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
CONSTRUCTION OF PROPOSED OFFICE BUILDING FOR GDA AT MADHUBAN BAPUDHAM SCHEME GHAZIABAD
CONSTRUCTION OF PROPOSED OFFICE BUILDING FOR GHAZIABAD DEVELOPMENT AUTHORITY AT MADHUBAN BAPUDHAM SCHEME GHAZIABAD
CONSTRUCTION OF PROPOSED OFFICE BUILDING FOR GHAZIABAD DEVELOPMENT AUTHORITY AT MADHUBAN BAPUDHAM SCHEME GHAZIABAD
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials . All kinds of soil- 1.5-3.0M

29083

-

77.72

... More
Same as item 4 but 3.0-4.5M DEPTH

17089.5

-

155.43

... More
Same as item 4 but 4.5-6.0M DEPTH

4997

-

233.15

... More
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil

10800.2

-

20.93

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

23.85

-

7354.28

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

450.71

-

4977.3

... More
Centering and shuttering including strutting, propping, etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete

2025.26

-

244.88

... More
Centering and shuttering including strutting, propping, etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers.

63767.06

-

474.6

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

5815.97

-

523.81

... More
Centering and shuttering including strutting, propping, etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts

14903.29

-

630.76

... More
Centering and shuttering including strutting, propping, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform

40113.86

-

595.81

... More
Centering and shuttering including strutting, propping, etc. and removal of form for: Weather shade, Chajjas, corbels etc., including edges

508.48

-

659.17

... More
Centering and shuttering including strutting, propping, etc. and removal of form for:Stairs, (excluding landings) except spiral-staircases

774

-

535.03

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire in all levels including all wastage etc. complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.

2118760.24

-

71.78

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for\ reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level

16801.46

-

8426.93

... More
Same as above item no. 18 but for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.

3256.61

-

8668.46

... More
Add Extra for providing richer mixes at all floor levels.Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

1571.92

-

59.96

... More
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.40 mm thick

264.6

-

1143.18

... More
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).

592.93

-

195.45

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063).Floor Joint of 100 mm gap

488.52

-

4809.88

... More
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). Wall Joint of 100 mm gap all as per the manufactures design and as approved by Engineer -in- Charge.

504

-

4004.73

... More
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.)Roof Joint of 100 mm gap

111.94

-

4464.8

... More
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

3053.02

-

5705.77

... More
Same as above item 26 but for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.

1810.15

-

5909.22

... More
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

1071.89

-

7073.03

... More
Same as above item 28 but for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.

391.06

-

7276.48

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

477.62

-

2599.68

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

786

-

154.06

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm

131

-

221.07

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm

131

-

89.02

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm

131

-

77.37

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm

262

-

45.44

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

131

-

53.34

... More
Providing and fixing 2nd class teak wood lipping/ moulded beading or taj beading of size 18X5 mm fixed with wooden adhesive of approved quality and screws/nails on the edges of the Pre-laminated particle board as per direction of Engineer-in-charge.

207

-

67.79

... More
Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.

234.05

-

3380.29

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

619.65

-

584.47

... More
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets :20 mm dia (heavy type)

542

-

133.81

... More
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).

309.2

-

1300.68

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.

211.28

-

33868.04

... More
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.

100

-

6133.81

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

60.08

-

3806.87

... More
Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

230

-

112.62

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

126

-

148.08

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B Fixing with adjustable lugs with split end tail to each jamb

682.4

-

359.01

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

2573.1

-

494.71

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade.Area of slab over 0.50 sqm.

134.67

-

3445.37

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work

839

-

323.46

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

203

-

631.49

... More
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.

1130.86

-

316.37

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

254.1

-

2129

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

870.33

-

3031.81

... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

21750

-

677.01

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick (Kota Stone to be same shade and color)

553.14

-

1316.93

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

226.18

-

1556.1

... More
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.

1058.4

-

127.32

... More
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre.

534.24

-

28.46

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

3827.04

-

885.75

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

1141.75

-

796.85

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm

4003.29

-

1290.02

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

1200.99

-

1328.96

... More
Supply & Installation of CAMFLOOR Cementitious Core Raised Access Floor in size 600mm x 600mm x 35mm in BARE Finish at an elevation of 150mm FFH using GI Pedestals. (The Shade, pattern etc., to be approved by Architect & Engineer in charge). All complete as per approved drawing and direction of Engineer-in- charge .150 mm Finished Floor Height (FFH)

7725.65

-

3181.5

... More
Supply & Installation of CAMFLOOR Cementitious Core Raised Access Floor in size 600mm x 600mm x 35mm in Antistatic HPL Finish at an elevation of 450mm FFH using GI Pedestals & Crossbeams. (The Shade, pattern etc., to be approved by Architect & Engineer in charge) .All complete as per approved drawing and direction of Engineer-in- charge .450 mm Finished Floor Height (FFH).

809.73

-

2348

... More
Providing and fixing of 10 mm thick Laminated wooden flooring Classification of Use 23/32 (Heavy Domestic/General Commercial) with a Surface Abrasion Resistance of class AC4 (average 4500 cycles), Impact Resistance of IC2 (EN13329), Resistance to Cigarette Burn with a rating of 5 (EN 438-2:15), Swelling after 24 hrs in water of 15% (EN13329), Modulus of Rupture of 53.3 newton/mm2, Internal Bond 1.78 newton/mm2, Surface Soundness of 1.3 newton/mm2 (EN 13329:2000) with a 0.2mm thick wear layer on top of a High Density Fiber substrate core (density 850 Kg/M3) of plank size 1291 mm X 135 mm having Uni fit locking arrangement (lock strength 1000 lbs/ft) with an underlayment made of natural colour foam , with accessories like End profile, Transition profile, reducer, etc. complete. The rate includes cost of all materials, accessories, labour, HOM, etc., complete at all levels. (The Shade, pattern etc., to be approved by Engineer in charge) All complete as per approved drawing and direction of Engineer-in- charge .

5310.5

-

1212

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places

2503.2

-

3705.12

... More
Supply & fixing of first radiant/first line tufted 1/10” loop carpet tile100% PA6 solution dyed aquation backing back to back modified bitumen, 10% recycled content included,fire resistant EN-1350-1B,,S1,pile height Ca2.9 mm, total weight ca 4300 gm/m2,pile densityca 0.114gm/cm3,thermal resistant ISO8302.0.047m2 K/W,impact noise rating ISO10140(1000Hz) tile size should be (500 cm X 500 cm) duly installed on smooth and hard surface with company recommended adhesive. All complete as per approved drawing and direction of Engineer-in- charge .

4026.8

-

1515

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

82

-

209.81

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase

387

-

203.96

... More
Providing & Applying of complete cool coating system (IR Reflective coating) with SRI up to 109 Cement roofs with GREEN PRO CERTIFIED .All complete as per approved drawing and direction of Engineer-in- charge .

3295.07

-

358.5

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board

3649.26

-

1105.74

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece

5728.33

-

1417.77

... More
Providing & fixing Armstrong Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063. The baffle blade shall be in size of 100x25x3600mm in powder coated to Woodgrain finish – Red Oak & Cherry. The baffle blade shall be suspended using Slotted U-profile at on-center spacing in multiples of 25mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps. Installation of U-Grid:The U profile to be suspended at every 1200mm on-centre using 6mm threaded rod from the structural soffit using U-profile hanger. U-profile splice to be used to join more than one U profiles of length 3.75M. 1st U-Grid Channel must be no more than 400mm from the perimeter.Installation of Armstrong Baffles: Locate the slot for Baffle Hangers in U Profile section at 1200mm centres. Hangers are inserted into the slot, then rotated 90° and fixed into position by tightening the grub screw. Baffle to be lifted into position and hangers engage over lip of U-Grid Channel. Each Hanger to be secured into position by inserting the Locking Clip. When doing continuous installation, Baffles blades are to be connected at ends with Baffle Joiner, which are inserted into the top and bottom slots of the Baffle closed profile for alignment only. The bottom Joiner to be located first and fastened on one side only. The top Joiner to be fitted then and secured with grub screws on one side. Then the two Baffle sections shall be joined and the top Joiner is screw fastened on the 2nd Baffle profile.End Caps to be located by pushing the End Cap tongues into open Baffle slots.Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure. All complete as per approved drawing and direction of Engineer-in- charge .

1301.2

-

9393

... More
Supply and installation at sitwe of aluminium batten system in Size 50mm x 100mm installed at gapof 150mm C/C ( 100mm clear ) in choice of wooden shades of average 80mm micron along with corresponding accessories

403.2

-

13783

... More
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge

1501

-

1413.3

... More
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of ength 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge.With 16 mm thick beveled tegular mineral fibre Antimicrobial false ceiling tile confirming to ISO 5 (class 100 ) specifications

2142.8

-

1829.65

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)

14263.93

-

226.57

... More
15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)

13789.27

-

274.2

... More
6 mm cement plaster of mix ::3 (1 cement : 3 fine sand)

43821.04

-

195.45

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

60432.39

-

98.99

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer

42414.73

-

131.92

... More
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)

911.6

-

78.45

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work

250

-

104.5

... More
Add Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

500

-

51.37

... More
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

5117.42

-

56.7

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

8844

-

392.28

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

6907.68

-

469.7

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)

820.29

-

1114.51

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width

4422

-

68.3

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.

1141.75

-

400.28

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

3295.07

-

1202.29

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

23550

-

321.01

... More
Same as above item 95 For vertical surface two coats @ 0.70 kg per sqm

1800

-

416.48

... More
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately).

2447.42

-

1906.59

... More
Red sand stone - 30mm thick gang saw cut stoneExtra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of.

1719.02

-

111.46

... More
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring andshuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin- charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).

48960

-

157.63

... More
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.

4896

-

281.12

... More
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases.

2448

-

31.12

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporatingprinciples of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide awater tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.

4534.12

-

2535.51

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

4634.12

-

2794.83

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.

780.12

-

2719.31

... More
Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly oriented glass fibres distributed in a binder by awet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.

1006.82

-

1619.28

... More
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

1233.53

-

1829.39

... More
Providing & fixing acoustic insulation wall panel of size 2400x 1200x12mm using staple pine foe fixing onto a wooden frame work as shown in drawing and height as per elevation drawings. All complete as per approved drawing and direction of Engineer-in- charge .

800

-

2272.5

... More
Providing and fixing frame work out of 50mmx 50mm hardwood sections placed at 610mm centre to centre both ways with joints staggered to avoid through joints.The frame work to be adequately anchored in ceiling and onfloor /wall having additional framework members to hols elec boxes etc;treated with anti-termite and fire retardent paint viper or equiy frames etc.complete straight and curved. All complete as per approved drawing and direction of Engineer-in- charge .

954.54

-

2390.5

... More
Providing &fixing 12mm mdf ( internal partition board ) skin over hardwood /GI frame with screws of 25mm at @300 c/c. The edges to be finished smooth....flush or grooved as directed(frame work to be paid in respective item). All complete as per approved drawing and direction of Engineer-in- charge .

954.54

-

564.5

... More
Providing and fixing decorative high pressure laminated sheet of plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS:2046 type S, including cost of adhesive of approved quality.1.0 mm thick

754.54

-

616.96

... More
Providing and fixing 6mm thick lacquered glass of approved shade to GI/ hard wood framing over 6mm ply base complete in all respect.All complete as per approved drawing and direction of Engineer-in- charge .

850

-

4351.7

... More
Providing and fixing FRAMELESS GLASS INTERNAL PARTITIONS with 12mm thick clear toughened glass with division(opening for door in glass)as shown in drawing and height as per elevation drawings.with approved make S.S fittings of S.S -316 grade All the glass shall be fixed with S.S fittings to the adjoining members/glass/brick/wood/RCC with fixings clips including filling up necessary gaps at junction,top ,bottom, and sides with required weather silicon sealant.The complete installation of glazing shall be as per drawings or as directed by Engineer-in-charge and as per the site conditions.Minimum two rows of spider to be provided to every vertical support.All complete as per approved drawing and direction of Engineer-in- charge .

719.82

-

6748

... More
Supply & installation of glass partition with stainless steel fixtures shall be as per drawings along with approved grade of silicon sealant.The partition shall be aligned for the entire height and for the entire width by laser beam equipement to ensure 100percent 'x' axis and 'y' axis alignment .The complete design fixing details,spider fittings ,details design will be done as per approval of engineer -in charge.(The work is to be got executed by approved specialized agency approved by engineer in charge).All complete as per approved drawing and direction of Engineer-in- charge .

879.73

-

11406.5

... More
Providing and fixing USGBORAL System Components. This includes fixing of ST 50 Floor and Ceiling channel (0.5 mm thick, 50mm wide & having two flanges of 32mm each) to the RCC Floor and Slab with Approved Fasteners @ 600 mm Centers respectively. ST 50 Wall Studs (0.5 mm thick, 48 mm wide having one flange of 34mm another of 36 mm). These Wall studs are placed at 610 mm centers in Floor and Ceiling channel. One layer of 12.5mm thick USGBORAL Standard Gypsum plasterboards (Confirming to IS 2095: Part 1) is screw fixed vertically to either side of Ultraframe wall Studs with 25mm long USGBORAL Drywall Screws at 300mm centers. The screw fixing of Gypsum plasterboards to the metal framing at the periphery, openings and cut edges should be at 150mm centers. The horizontal & vertical joints of the Gypsum plasterboards on both sides of the metal framework must be staggered so as to avoid through and through joints. All joints to be taped & finished with 50mm wide USGBORAL Paper tape & All Purpose Joint compound. All complete as per approved drawing and direction of Engineer-in- charge .

1863.63

-

1222.5

... More
Exterior Design and Artwork-The exterior wall installation showcases a curated art composition that conveys brand and identity of GDA . Outline of Ghaziabad map fabricated metal sheet will be wrapped around hand beaten square metal crafted rods. The letters ‘ GDA’ will be finely cut in laser technique bringing in the refinement and quality. The installation would be brilliantly lit from the back giving a glowing effect to the entire composition and will become a highlight wall of the city instilling a sense of pride among its citizens. Total wall 1000 sq feet 20 *50 feet All complete as per approved drawing and direction of Engineer-in- charge . The letters will be crafted with hand beaten 16 gauge sheets and rods of iron finely crafted with an antique finish. Each letter approx. 10-12 ft in size. The installation will be subtly pitted and on distressed finish. Covered with raw beewax protective layer. Rich, lustrous, semi-transparent finish that highlights the character and elegance of the metal. Usage of sustainable and durable material. Installation area 800 sq feet All complete as per approved drawing and direction of Engineer-in- charge .

800

-

4418.7

... More
Exterior Design and Artwork-The exterior wall installation showcases a curated art composition that conveys brand and identity of GDA . Outline of Ghaziabad map fabricated metal sheet will be wrapped around hand beaten square metal crafted rods. The letters ‘ GDA’ will be finely cut in laser technique bringing in the refinement and quality. The installation would be brilliantly lit from the back giving a glowing effect to the entire composition and will become a highlight wall of the city instilling a sense of pride among its citizens. Total wall 1000 sq feet 20 *50 feet All complete as per approved drawing and direction of Engineer-in- charge . Birds sweeping into the sky from the water body. Birds fabricated from specialized hand crafted 1mm hand beaten metal sheet with fine quality paint and polish- Each bird will be fabricated with a specialized technique by trained artisan. 100 birds will be installed in a flight formation – welded together in an artistic way to represent the 100 wards of GDA within a setting of a reflective pool.400 sq feet All complete as per approved drawing and direction of Engineer-in- charge .

400

-

3798.5

... More
Exterior Design and Artwork-The exterior wall installation showcases a curated art composition that conveys brand and identity of GDA . Outline of Ghaziabad map fabricated metal sheet will be wrapped around hand beaten square metal crafted rods. The letters ‘ GDA’ will be finely cut in laser technique bringing in the refinement and quality. The installation would be brilliantly lit from the back giving a glowing effect to the entire composition and will become a highlight wall of the city instilling a sense of pride among its citizens. Total wall 1000 sq feet 20 *50 feet All complete as per approved drawing and direction of Engineer-in- charge . The Indian National Flag represents the Union of India, its National identity and pride. The wall of unity is a curated installation of 2 metal screen walls inscribed with versus of the national anthem. Fabricated from specialized hand crafted 18 gauge hand beaten metal sheets with fine quality paint and finish and beewax coated. The screens integrated with chakra installation of antique wood with specialized conservation treatment for outdoor durability.250 sq feet All complete as per approved drawing and direction of Engineer-in- charge .

250

-

4040

... More
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick flat

732

-

859.14

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

900

-

87.47

... More
Plumbing -Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade

25.99

-

2765.56

... More
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

5

-

4660.85

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

203

-

11908.92

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

191

-

2654.49

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

12

-

3785.94

... More
Providing and fixing stainless steel A ISI 304 (18/8) Kitchensink as per IS : 13983 with CI bracket and stainless steel plug 40 mm including painting of fittings and brackets ,cutting and making good the walls wherever required:Kitchen sink with drain board 510 x 1040 mm bowl depth 200 mm

16

-

4800.64

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

203

-

255.8

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

203

-

759.16

... More
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia

16

-

5255.85

... More
Providing and fixing toilet paper holder :C.P. brass

203

-

501.85

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

77

-

5943.86

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameter

5

-

130.59

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore

10

-

521.19

... More
Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length

609

-

68.39

... More
20mm nominal bore Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore.

10

-

360.17

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore.

10

-

531.98

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore

609

-

457.36

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe.32 mm dia

20

-

86.92

... More
same as above item but 40 mm dia

20

-

86.92

... More
Providing and Fixing 4-way concealed divertor with built-in NRV with divertor handle weight not to be less then 1.5 Kg

2

-

4948

... More
Providing and Fixing Over head shower 100 mm dia with Shower Arm complete as per instructions of the engineer-incharge

2

-

888

... More
Providing and Fixing CP Bath spout with wall flange complete as per instructions of the engineer-in-charge or as per equivalent make .

2

-

1528

... More
Providing and Fixing CP auto push cock with CP Wall flange for Drinking water sink complete as per direction of the engineer-in-charge for drinking water

191

-

1602

... More
Providing and Fixing C.P. brass towel ring "Round" fixed to PVC cleats with C.P. brass screws including cutting and making good the walls wherever required

60

-

1247

... More
Providing and fixing soap dish of approved quality and colour complete as per direction of the engineer-in-charge

15

-

909

... More
Providing and fixing 600mm long CP Brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.

15

-

1412

... More
Providing and fixing C.P cast brass Double coat hook fixed to PVC cleats with C.P. brass screws complete as per instructions of the engineer-in-charge

203

-

530

... More
Providing and Fixing 12" long Hand rail (Grab bar) for Handicap Toilets with Stainless Steel Screws on wooden cleats complete as per instructions of the engineer-in-charge (As per approved make or equivalent) .

90

-

603

... More
Providing and Fixing C.P. Sliding Rail with stainless steel screws on plastic cleants complete in all respects as per the Engineer- In -charge

30

-

4349

... More
Providing and Fixing Geysers of 25 litre capacity of reputed make as specified in the recommended make list.

12

-

9475

... More
Providing and Fixing Hand dryer of reputed make as specified in the recommended make list.

12

-

10671

... More
Providing and Fixing Paper Despenser of reputed make as specified in the recommended make list.

12

-

8464

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

50

-

209.81

... More
Providing and fixing soil, waste and vent pipes : 100 mm dia.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

1813.88

-

904.19

... More
Providing and fixing soil, waste and vent pipes : 75 mm dia.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

1176

-

738.95

... More
Providing and fixing on wall face uplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with steel ring conforming to IS 5382 leaving 10 mm gap for thermal expansion (i) single socketed pipes.110 mm dia

873.6

-

262.25

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single pushfit Coupler110 mm

291

-

93.23

... More
Same as above item but Single tee with door110 x 110 x 110 mm

38

-

174.78

... More
Shoe (Plain)110 mm

28

-

97.83

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

42

-

40.62

... More
Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter :100 mm

896

-

108.75

... More
Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter 75 mm

392

-

67.4

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

53

-

471.63

... More
Providing and fixing plain bend of required degree.100 mm dia.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

355

-

295.65

... More
75 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

494

-

208.86

... More
Providing and fixing double equal plain junction of required degree.100x100x100x100 mm Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

5

-

617.74

... More
Providing and fixing single equal plain junction of required degree :100x100x100 mmHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

221

-

491.19

... More
75x75x75 mmHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

163

-

272.14

... More
Providing and fixing single unequal plain junction of required degree :100x100x75 mmHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

189

-

462.43

... More
Providing and fixing Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905 130 mm offsetsWith 100 mm dia

42

-

537.18

... More
same as above item but With 75 mm dia

11

-

381.4

... More
Providing and fixing terminal guard :100 mm dia.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

21

-

341.64

... More
Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm dia SS 304 grade coupling with EPDM rubber gasket

2375

-

347.4

... More
same as above item but 75 mm dia SS 304 grade coupling with EPDM rubber gasket

1411

-

312.37

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

189

-

652.21

... More
Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :100 mm dia

65

-

477.39

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall40 mm dia

286.5

-

549.86

... More
Same as above item but 50 mm dia

283.5

-

676.37

... More
Providing and Fixing G.I. Reducing elbow of 100 x 50 mm in cement concrete 1:2:4 at all levels for floor drains (exlcuding cost of grating) for connection to floor traps in sunken portions, complete as per drawings and as per approval of the engineer-in-charge.(GI Pipe for connecting elbow with floor trap shall be measured seperately )

189

-

465

... More
Providing and fixing G.I. Inlet fitting with maximum 3 inlets 32,40 & 50 mm size fabricated from 100 mm dia G.I. pipes and welded G.I. sockets as per site locations, fixed to C.I. Trap and set with proper sealing compound as per drawing complete as per approval of the engineer-in-charge.

189

-

531

... More
Providing and fixing cast brass Floor Clean Out plug with suitable insert keys for opening, male threaded joint with G.I. socket drip seal to soil pipe / waste pipe of C.I. pipe as required complete as per drawing, approved sample and direction by Engineer-in-charge:100 mm dia

76

-

646

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal outer dia Pipes

1014.3

-

352.18

... More
Same as above item but 20 mm nominal outer dia Pipes

1272.6

-

411.06

... More
Same as above item but 25 mm nominal outer dia Pipes

929.25

-

483.11

... More
Same as above item but 32 mm nominal outer dia Pipes

309.75

-

583.86

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work25 mm nominal outer dia Pipes

50

-

280.82

... More
Same as above item but 50 mm nominal outer dia Pipes

480

-

680.58

... More
Same as above item but 62.5 mm nominal inner dia Pipes

165

-

1334.51

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20mm nominal outer dia Pipes

268

-

263.88

... More
Same as above item but 25 mm nominal outer dia Pipes

529

-

317.4

... More
Same as above item but 32 mm nominal outer dia Pipes

529

-

413.13

... More
Same as above item but 40 mm nominal outer dia Pipes

693

-

557.6

... More
Same as above item but 50 mm nominal outer dia Pipes

693

-

776.74

... More
Same as above item but 65 mm nominal outer dia Pipes

236.5

-

2150

... More
Same as above item but 80 mm nominal outer dia Pipes

163

-

2956

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):20 mm nominal bore

21

-

395.63

... More
Same as above item but 25 mm nominal bore

93

-

427.4

... More
Same as above item but 32 mm nominal bore

83

-

499.7

... More
Same as above item but 40 mm nominal bore

38

-

583.22

... More
Same as above item but 50 mm nominal bore

38

-

747.25

... More
Same as above item but 65 mm nominal bore

17

-

1279.32

... More
Same as above item but 80 mm nominal bore

8

-

1906.72

... More
Providing & fixing dual flanged C.I. `Y' Strainer with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required.65 mm nominal bore

2

-

3615

... More
Supply, installation , testing & commissioning of Nytril Rubber Insulation and polyshield outer mechanical protection (comprising of wrapping with poly glass tape helically wound and subsequently applying 2 coats of polyshield material (resin & hardner) as per manufacturers specification) on Hot and chilled water supply lines having thermal conductivity .038 W/mok 0.212 BTU / (Hr-ft2-oF/inch) at an average temperature of 30oC ,temperature range of –40oC to 105oC,Density of material shall not be less than 0.06 gm/cm3, class O type, complete as per manufacturer recommendation.15 mm nominal outer dia Pipes

25

-

57

... More
Same as above item but 20 mm nominal outer dia Pipes

20

-

98

... More
Same as above item but 25 mm nominal outer dia Pipes

20

-

132

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

15

-

1360.43

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

1

-

7985.21

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.

125

-

216.9

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m All kinds of soil Pipes, cables etc, not exceeding 80 mm dia.

495

-

191.71

... More
same as above iten but Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

550

-

313.1

... More
same as above iten but Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

10

-

488.82

... More
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

550

-

397.64

... More
same as above iten but Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

15

-

620.81

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter

25

-

430.02

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5

16

-

1983.32

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. Pipe

150

-

397.7

... More
Same as above item but 250 mm dia. R.C.C. Pipe

400

-

648.6

... More
Same as above item but 300 mm dia. R.C.C. Pipe

265

-

742.48

... More
Same as above item but 450 mm dia. R.C.C. Pipe

125

-

1197.3

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

15

-

9375.04

... More
Same as above item but Extra for depth for manholes :Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

10

-

6450.31

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with SFRC cover and frame (heavy duty, HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

15

-

9489.43

... More
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5

10

-

5543.67

... More
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

20

-

18256.23

... More
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

18

-

7194.29

... More
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

5

-

39081.11

... More
Extra depth for circular type manhole 1.52 m internal dia (at bottom) upto 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

5

-

16776.39

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

180

-

398.08

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

10

-

4478.25

... More
Providing and executing 30 Cum. modular harvesting pit of polymer based modules (Honeycomb design on each plates) made up of 100% recycled polypropylene, capable of taking vehicular movement up-to at-least 40 tons. The pit shall be wrapped with geotextile fabric material to prevent soil insertion and effective insertion of sorrounding water. The Geotextile material shall be UV resistant, conforming to ASTM 154/EN 12224, non-woven geotextiles having thickness of 400 GSM, having minimum tear strength of 250 kg/cm2 as per ASTM D4533, width wise at-least 215 kg/cm2 as per ASTM D4533 having puncture strength of 1550 kg/cm2 as per ASTM D6241, having elongation at break of 57% plus as per ASTM D4595 in two layers, made out of long fibres to hold the modules including cutting, sizing, heat welding and needle punched for high porosity and proper percolation complete as per entire satisfaction of Engineers- in- charge. The cost shall be inclusive of all necessary excavation in all kind of soils, refilling, Boring upto aquifier and disposal of surplus earth with in the site or away from site as directed with out any extra cost, including required nos. 600 x 600 mm, Heavy Duty FRP Cover (Load bearing capacity of 12.5-20 tons). Depth shall be as per actual site condition and invert level. The item is iclusive of FRP based filter with diameter of 650 mm and height 1000 mm having inlet and outlet of required size with SS 304 mesh. Flow rate of filter should be at-least 40-45 KL/hr. FRP based RWH filters should be GRIHA and SVAGRIHA certified with valid certification on date. The product should be registered under GRIHA Criterions 21 &18 & SVAGRIHA Criterions 9.

4

-

560550

... More
Providing and Fixing NS 7 Grease Separator plant as per DIN EN 1825 / PDI certified recessed or floor mounted epoxy coated steel grease interceptor with gasketted solid steel cover, hex head centre bolts, removable baffle assembly, deep seal trap with clean out, no hub connections & external cast iron flow control fittings, with manhole cover, 1 set of operating keys, nominal connection size 75mm, odour proof sealed, with direct suction pipe, along with all necessary accessories and equipment complete including necessary foundations, civil works and finishing as per site requirements and as per instructions of the engineer in charge.This shall be provided with sediment bucket epoxy coated steel located inside the interceptor on inlet side, collects large food or other particles, to the extent possible, sediment should be strained or collected at the fixture prior to the grease interceptor, sediment entering the waste line is likely to clog the interceptor flow restrictor, slowing drainage, and causing backup difficulties, Heavy duty traffic cover rated 10,000 lbs. , flange and clamp device complete as required or approved by EIC/ manufacturer recomendations (Rate shall be for complete system including all necessary taxes, duties, levies etc.)

1

-

541756

... More
Supplying, installation, testing and commisioning of Single flap backwater valve for restricting the storm water to flow in the backward direction into the site pipelines, with two polymer flaps, installation area 650×300 mm, self-closing type, one of which can be locked by hand as an emergency closure. The Inlet/outlet for connection to PVC/HDPE pipe to be in accordance to EN 1566-1. The item is exclusive of any civil work and same shall be referred from the respective item description. For 300 mm diameter Pipe

2

-

80880

... More
same as above item but For 250 mm diameter Pipe

1

-

69326

... More
Supply, Installation, Testing & Commisioning of Reverse Osmosis unit of following capacity to treat the raw water having TDS 1200 ppm and reducing TDS to 100ppm and hardness less than 50 ppm or as per WHO standards. The operating voltage to 230 volt AC +/- 10%. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be to ANSI/NSF 61 Section 9. Contractor shall require to submit test report post installtion of RO plant and cost shall be inclusive of 15 days training to engineer incharge. 1. Pre and Post treatment Dosing System (each consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing speed & stroke control pump (1W + 1S) having variable flowrate of 0-6 lph. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary agitator, polypropylene piping, valves, strainers, low level switch(Range 0-600mm) and injection fittings.): a) Biocide dosing system for pre and Hypochlorite and soda ash post dosing and dosage rate 2-3 mg/l. b) Anti scalant dosing system for dosing downstream of MGF and ACF and dosage rate 5 mg/l. c) Acid dosing system in inlet of RO membrane and dosage rate 2 mg/l. d) SMBS dosing system for dechlorination at the inlet of RO membrane and dosage rate 5-10 mg/l. e) PH Correction Dosing system(NaOH) for maintaining the ph to drinking water standard. Dosage required will be 2 mg/l.2. Filtration System: a)Activated Carbon Filter with initial charge of pebbles, anthracite, media , connecting with multiport valve (for controlling all operations for rinsing, backwashing, service etc under automated system linked with differential pressure transmitter and differential guage), glycerine filled pressure gauge at inlet, outlet and back wash (each with isolation cock), complete as required including wiring and anunciation complete as required with SS 304 piping(paid separately) complete as required and all other accessories required to make the system complete as per the specifications. b) Water softener with brine tank (200 litre HDPE). c) CIP System. d) Raw water feed Pump.3. Reverse Osmosis System: a) High Pressure Pump(1W+1S): Vertical centrifugal Pump with low pressure switch for smooth operation, dry run protection of adequate capacity and head with SS AISI 304 stage casing, AISI SS 304 impellors, SS Suction chamber, SS 304 Pump shaft, steel base plate, carbon mechanical shaft seal and suction and discharge casing as per IEC standards, connected to TEFC Ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply with glycerin filled pressure gauge , vibration elimination pads, dry run protection etc. complete with base and frame, nuts and bolts. The pump should be rated at the premium efficiency rating of IE. The pump inclosure to be minimum IP 54 rated and insulation class to be F. b) Reverse Osmosis Block comprising of micron filter and membrane encased inside pressure vessels. the membrane to be thin film composite in spiral wound construction. Membrane material to be TFC Polyamide. RO Housing to FRP material with pressure rating of 250 psi. c) Ultraviolet Unit of required flow rate.Capacity: 1000 LPH

1

-

300000

... More
Supply, installation , testing & commissioning of Stainless Steel water tank with inner layer SS316 (0.8mm) + Outer Layer SS 304 (0.6mm) of specified thickness. The tank should be provided with inlet, outlet and vent/overflow connection, 75mm Puf Insulation , cover 450mm dia, Inlet connection of water tank shall be of 25mm nominal bore, overflow/vent - 25mm nominal bore and outlet connection at bottom of tank of 50mm nominal bore. Cost of tank shall be inclusive of Angle stiffeners, stand leg, SS flanges connecting from water treatment facility and distribution system complete as per approved specifications.Capacity: 3000 litre

1

-

145000

... More
Supply, Installation, Testing & Commisioning of Reverse Osmosis unit based water Purifier (wall mounted) of 50 LPH capacity to treat the raw water having TDS 1500 ppm and reducing TDS to 80ppm and hardness less than 50 ppm or as per WHO standards. The operating voltage to 230 volt AC +/- 10%. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be to ANSI/NSF 61 Section 9. Contractor shall require to submit test report post installtion of RO plant and cost shall be inclusive of 15 days training to engineer incharge.

4

-

35000

... More
Supply, installation , testing & commissioning of high efficiency Storage water cooler / Dispenser of follwing capacities with water at 15°C cooled from 40°C inlet water at 35°C ambient. Evaporator shall be high tank type and shall be encapsulated in insulation. R-404 refrigerant system shall be hermetically sealed and refrigerant shall be capillary tube controlled. An adjustable thermostat having an off position shall control refrigeration system. Cabinet shall be galvanized steel. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be to ANSI/NSF 61 Section 9. chiller should be single phase 220 V, 50 Hz, with cooling coil, heavy gauge galvanized steel complete as required including foundation, complete as required. Cooling capacity : 80 lts/hr. And storage capacity 120 lts

4

-

42000

... More
Supply, installation , testing & commissioning of high efficiency bottle filling and drinking water fountain, compling with ANSI 117.1 and ADA, of 8GPM capacities which will provide chilled water at 15°C cooled from 40°C inlet water at 45°C ambient. The bottle filling unit shall be with manual actuation. The unit shall be with anti-microbial compound that reduces the growth of micro-organisms and mildew to protect the surfaces from discoloration, odors and degradation. Basin shall be designed to eliminate splashing and standing water. Water saver bubblerwhich reduces waste water by 50% and shall have flexible guard and operate between 20 and 100 PSI. Cabinet finish shall be sandstone on galvanized steel or brushed stainless steel. Evaporator shall be high tank type and shall be encapsulated in insulation. R-134a refrigerant to be used. An adjustable thermostat having an off position shall control refrigeration system. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be to ANSI/NSF 61 Section 9. chiller should be single phase 220 V, 50 Hz, with cooling coil, heavy gauge galvanized steel complete as required including foundation, complete as required.

12

-

99330

... More
Supply, installation , testing & commissioning Single/multistage monoblock pumping set with stainless steel CI stage casing and SS-304 impellers with stainless steel shaft and suction & discharge casing as per IEC standards , connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply with glycerin filled pressure gauge and with gunmetal isolation valves, vibration elimination pads etc. complete with base and frame, nuts and bolts. All valves, RCC foundations and foundation bolts shall be paid seperately under relevant heads as per requirement and as per instructions . The vender shall submit performance curve and technical data sheet to the consultant prior to installation. The head versus discharge curve shall be on the rising side. including termination of cables on motor. Nos. of Pumps : 2Nos (1w+1s) : Filter Feed Pumps Flow Rate : 2.5 LPS Head : 30 mtr.

1

-

53122

... More
Same as above item but Nos. of Pumps : 2 Nos (1w+1s) : Domestic water Transfer Pumps Flow Rate : 3 LPS Head : 60 mtr.

1

-

148734

... More
Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage/sewage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries including float type level controllers, electrical control panels fabricated from 14 gauge CRCA sheet volt meter ammeter with selector switch, TPMCB, 5 VA CL : CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determind level. Nos. of Pumps : 2 Nos (1w+1s) : Plant Drainage Pumps Flow Rate : 5 LPS Head : 15 mtr.

1

-

125433

... More
Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage/sewage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries including float type level controllers, electrical control panels fabricated from 14 gauge CRCA sheet volt meter ammeter with selector switch, TPMCB, 5 VA CL : CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determind level. Nos. of Pumps : 2 Nos (1w+1s) : Basement Drainage Pumps Flow Rate : 5 LPS Head : 15 mtr.

12

-

125433

... More
Multigrade Filter: Supply, installation , testing & commissioning of MSEP filter complete with initial charge with pebbles, anthracite, media , connecting with multiport valve (for controlling all operations for rinsing, backwashing, service etc under automated system linked with differential pressure transmitter and differential guage), glycerine filled pressure gauge at inlet, outlet and back wash (each with isolation cock), complete as required with sand blasted inside and outside, finished with 6-8 mm thick epoxy lining reinforced and including wiring and anunciation complete as required(Thinner plate for shell and dished ends not acceptable) complete as required and all other accessories required to make the system complete as per the specifications. Filteration Rate 14000L/Sqm/Hr Test pressure 4.5 Kg/Sq.cm Working pressure 3.5 Kg/Sq.cm Maximum pressure 4 Kg/Sq.cm Media Depth to be minimum 150 mm coarse sand, 200mm fine sand and 200mm anthracite. Diameter- 900 mm

1

-

170000

... More
Activated Carbon Filter: Supply, installation , testing & commissioning of MSEP filter complete with initial charge with pebbles, anthracite, media , connecting with multiport valve (for controlling all operations for rinsing, backwashing, service etc under automated system linked with differential pressure transmitter and differential guage), glycerine filled pressure gauge at inlet, outlet and back wash (each with isolation cock), complete as required with sand blasted inside and outside, finished with 6-8 mm thick epoxy lining reinforced and including wiring and anunciation complete as required(Thinner plate for shell and dished ends not acceptable) complete as required and all other accessories required to make the system complete as per the specifications. Filteration Rate 14000L/Sqm/Hr Test pressure 4.5 Kg/Sq.cm Working pressure 3.5 Kg/Sq.cm Maximum pressure 4 Kg/Sq.cm Media Depth to be minimum 150 mm coarse sand, 200mm fine sand and 500mm activated carbon. Diameter- 900 mm

1

-

180000

... More
Supplying, installing, testing and commissioning of chlorine dosing system consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing pump having variable flowrate. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary agitator, polypropylene piping, valves, strainers, low level switch(Range 0-600mm) and injection fittings. The pump shall be speed & stroke control. (Pump to be with one working and one stand by assembly). Flow rate : 0-12 lph

1

-

24000

... More
Supplying, installing, testing and commissioning of PH Correction dosing system consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing pump having variable flowrate. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary agitator, polypropylene piping, valves, strainers, low level switch(Range 0-600mm) and injection fittings. The pump shall be speed & stroke control. (Pump to be with one working and one stand by assembly). Flow rate : 0-12 lph

1

-

24000

... More
Providing & fixing on line turbine type flow meter of following sizes with preamplifier & microprocessor based electronic flow meter mounted in plumbing plant room electrical control panel with the following features. Monitoring the total flow, Flow rate, high low arm batching and blending etc. Including electrical wiring from preamplifier to microprocessor based flow meter. Complete with all type of Plumbing & Electrical connections, accessories, wiring, conduits & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received on BAS. Flow Rate Range : upto 1000 LPM Temperature Range : upto 85 degree celcius. Pressure Range : upto 50 bar Material of construction: Stainless steel IP Rating: IP 67 for transmitter and IP 68 for senser. Accuracy : 1 % on positive and negative side.

1

-

34000

... More
Supplying, Installation, Testing and Commisioning of Water level indicators cum controllers of Stainless Steel Probe with Digital display panel for installation on storage tanks, and capable of providing 4 to 20 mA analog signal compatible with PLC signal inputs ( probe should be provided with 20m cable with no connection joints in single run) and complete as per working requirements . All analog output from probe should be indicated in digital output panel placed in MCC panel and wiring should be done for interlocking , auto start / stop of pump complete as per specifications and as required. Including annunciation and indication panel with interlocking arrangement complete in accordance to specification with level indicator (for Borewell line to raw tank and filter feed line to dom. tank , : High / Low Level Controller) etc with control cabling from field to MCC as required. Vender needs to submit IO summary prior to finalization for approval.

4

-

22000

... More
Supplying, Installation, Testing and Commisioning of online TDS meter suitable for fixing at domestic water treatment station for online monitoring of water quality and inlet and oulet, equipment shall be provided with Built-in non-volatile memory,local display, Automatic Temperature, Compensation, Password Protected, IP - 67 rating, measuring following range , including cable termination for controlling and alarming complete as per specifications ( cost of cabling and end termination shall be paid under relevant subhead) 0 to 3000 ppm

1

-

38000

... More
Supplying, Installation, Testing and Commisioning of online Ph meter suitable for fixing at domestic water treatment station for online monitoring of water ph level at outlet of treatment station, equipment shall be provided with Built-in non-volatile memory,local display, Automatic Temperature, Compensation, Password Protected, IP - 67 rating, measuring range 4 to 12 ph , including cable termination for controlling and alarming complete as per specifications ( cost of cabling and end termination shall be paid under relevant subhead). The meter to be set at a range of 6.5 to 8 ph level with automatic linkage with the ph correction dosing system to control ph level.

1

-

45000

... More
Supply, installation, testing and commissioning of the UV unit of flow rate 10000 LPH consisting of reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lampout alert, UV radiometer along with UV monitoring system and UV monitoring readout panel (Intensity monitor required which shows the life cycle remaining since commissioning, Lamp replacement indicator, lamp failure indicator etc.). The UV Dosage should be 30,000 uW – Sec / sq.cm. The lamps should be selected based upon the flow requirement of respective unit. The unit shall be complete with temperature safety control, lamp out alert circuit & UV radiometer with 4 – 20 mA output and auto cleaning feature. The treatment chamber shall be SS 316.

1

-

140000

... More
Supplying, Installation, Testing and Commissioning of diameter electronic water meter with direct reading dial in KL with all internal parts in gunmetal or brass, flanged distance piece for easy removal in future, strainer, 100mm dia Bourden type gylicerine filled pressure gauge and isolation cock complete in all respects. 65 mm dia water meter with 80 mm dia strainer

1

-

46000

... More
Supply, installation , testing & commissioning of 150 mm diameter mosquito proof brass overflow grating for underground/overhead water tanks.

6

-

1000

... More
Supply, installation , testing & commissioning of 150 mm diameter insect vermin -proof coupling to vent pipes of underground tank/overhead tank with threaded or flanged joints, including M.S. flanges, nuts, bolts, 3mm thick rubber insertions complete.

6

-

1000

... More
Supply, installation , testing & commissioning of 600 mm long MS hot dip galvanized Puddle Flange fabricated out of 6 mm thick MS plates of suitable size and IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 mm or wall thickness plus 200 mm on either side (which ever is more). 32 mm dia

6

-

650

... More
Same as above item but 50 mm dia

8

-

850

... More
Same as above item but 65 mm dia

8

-

980

... More
Same as above item but 80 mm dia

8

-

1350

... More
Same as above item but 100 mm dia

8

-

1600

... More
Same as above item but 150 mm dia

6

-

2000

... More
Same as above item but 200 mm dia

4

-

2600

... More
Designing, providing, installation, testing and commissioning of Sewage treatment plant (STP) with sewage handling capacity 50 m3 per day including all piping (PVC SH 40/80), valves, sleeves based on MBBR technology complete in all respects, including all equipments and consumable materials of STP and excluding construction of tanks in civil. The raw sewage collection sump with double bar SS screen shall be a part of the STP. The STP shall be designed as water retaining structures including necessary chemical dosing as required by the manufacturer's design. All the equipment, piping, pumps, blowers and electrical to be housed in a plant room , inlet, outlet overflow, vent, C.I. cover, drain channel , sump to house pumps. The design basis considered to size the treatment plant is as follows including as required in the specification etc. Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for the above mentioned component and additional component if so required for the complete working of the STP and got it approved by the Owner’s Architect / Project Manager / Consultants. Sewage from toilets and kitchen and Recycled Water coming out from STP would be resued for irrigation and flushing purposes. Following are the inlet and outlet parameters for the same:Inlet Parameters COD : 400-450 mg/l BOD : 300-350 mg/l TSS : 200-450 mg/l Oil & Grease : 50-140 mg/l pH : 6.5-8.5 Suspended Solids : 250 mg/lOutlet Parameters COD : 30 mg/l BOD : 10 mg/l TSS : 10 mg/l Oil & Grease : 5 mg/l pH : 6.5-7.5 NH4-N : 5 mg/l N-Total : 5 mg/l PO4-P : 2 mg/lCompartment Sizes shall be as below: Equilization Tank : 15 KL Aeration Tank : 40 KL Secondary Settling Tank : 5 sq. Mtr. Chlorine Contact Tank : 5 KL Sludge Holding Tank : 20 KL Clear water Tank : 50 KL Treated water Tank : 25 KLScreen Chamber/ Oil & Grease Trap : Providing & fixing screen chamber including 2 Nos. Stainless Steel Suitable Manually operated Bar Screen made of SS 304 in RCC screen channel of size 1200mm x 600mm having provision for lifting arrangement etc. complete as required. The gap between the bars to be kept as 25 mm in coarse side and 10 mm in fine side.

1

-

24000

... More
Air Blower :Supply, Installation, Testing & Commissioning of 2 Nos. (One working & one standby) twin Lobe VFD based Air Blower capable of delivering 60 M3/hour of free air each at 0.5 Kg/cm2 driven through ‘V’ belt or directly coupled through flexible coupling to a TEFC motor of suitable HP (Approve motor rating as per manufacture recommendation suitable for 415 + 10% volts, 3 phase, 50 cycle AC Supply. The Blower working shall be linked with the DO sensers in the equilization and aeration tanks. The DO sensers shall be located uniformily in the tanks(1 senser for each 50 KL capacity).

1

-

168000

... More
Oil Skimmer : Supply, Installation, Testing & Commissioning of mechanical belt type oil skimmer basin with MS housing with 200 liter HDPE tank for 1/2 Lph flow rate capacity complete in all respect.

1

-

52000

... More
Air Diffuser : Supply, installation, testing & commissioning of adequate capacities of EPDM air diffusers in Equalisation tank, Media tank, Aeration and sludge holding tank for providing aeration.

1

-

25000

... More
Piping/Valves & Accessories : Providing and fixing all piping (as described below) and isolation control valves, Check valves, multiport valves for making the system complete. SS 304 Submerged Air piping MS(Heavy Duty) Epoxy : Air piping & pumped effluent riser (non-submerged) PVC (10KG)piping : Pumped effluent (submerged) & tank overflow pipe line PVC (10KG)piping : Interconnecting pipe line after delivery header of pump/ filter. All valves to be metallic construction and rated for PN 16 rating. Forged brass ball valves and CI Butterfly, check valves, pressure guages etc.

1

-

128000

... More
Raw Sewage Handling Pump(Equilization Tank): Submersible Centrifugal pump - Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging pumps for sewage handling pump for raw sewage transfer from equalization tank to aeration tank complete with 1/3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries including pressure gauge, Ball valve/Butterfly valve/Non return valve lifting arrangement for the pump, valves, level controller, probes, cable, chain pulley arrangement for lifting and lowering of pumps etc provision of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determined level. (1W + 1S) Flow Rate : 2.5 M3/hr Head 15 m Solid Handling 35 - 40mm

1

-

74000

... More
Sludge Re-circulation Pump : Providing, fixing, testing & commissioning of 2 No (1W+1S)horizontal, non-clog centrifugal Sludge recirculation pump for the disposal of settled sludge from Secondary Settling tank to Aeration tank and Sludge Holding Tank. The pumps shall have CI casing, CI Impeller & SS shaft & sleeve with mechanical rotary shaft seal connected by a flexible tier type coupling to TEFC induction motor mounted on a common channel base-plate with coupling guard, pressure gauge with GM isolation cock on delivery line suitable vibration eliminator pads of approved design. Motor to be suitable for 220/415 volts,1/ 3 phase, 50Hz AC supply including all necessary piping, valves and other accessories complete as required. Contractor shall provide foundation bolts and drawings to civil vendor for installation of pumps.(1W + 1S) Flow Rate 1 M3/hr Head 15 m Solid Handling 35 - 40mm

1

-

74000

... More
Supply, installation , testing & commissioning Single/multistage monoblock pumping set with stainless steel CI stage casing and SS-304 impellers with stainless steel shaft and suction & discharge casing as per IEC standards , connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply with glycerin filled pressure gauge and with gunmetal isolation valves, vibration elimination pads etc. complete with base and frame, nuts and bolts. All valves, RCC foundations and foundation bolts shall be paid seperately under relevant heads as per requirement and as per instructions . The vender shall submit performance curve and technical data sheet to the consultant prior to installation. The head versus discharge curve shall be on the rising side. including termination of cables on motor. Nos. of Pumps : 2 Nos (1w+1s) : Filter Feed Pumps Flow Rate : 1.5 LPS Head : 30 mtr.

1

-

82000

... More
Nos. of Pumps : 2 Nos (1w+1s) : Flushing water Transfer Pumps Flow Rate : 2.5 LPS Head : 60 mtr.

1

-

162000

... More
Nos. of Pumps : 2 Nos (1w+1s) : Irrigation water Transfer Pumps Flow Rate : 4 LPS Head : 45 mtr.

1

-

180000

... More
Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage/sewage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries including float type level controllers, electrical control panels fabricated from 14 gauge CRCA sheet volt meter ammeter with selector switch, TPMCB, 5 VA CL : CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determind level. Nos. of Pumps : 2 Nos (1w+1s) : Sump Pumps Flow Rate : 4 LPS Head : 15 mtr.

1

-

152000

... More
Multigrade Filter: Supply, installation , testing & commissioning of MSEP filter complete with initial charge with pebbles, anthracite, media , connecting with multiport valve (for controlling all operations for rinsing, backwashing, service etc under automated system linked with differential pressure transmitter and differential guage), glycerine filled pressure gauge at inlet, outlet and back wash (each with isolation cock), complete as required with sand blasted inside and outside, finished with 6-8 mm thick epoxy lining reinforced and including wiring and anunciation complete as required(Thinner plate for shell and dished ends not acceptable) complete as required and all other accessories required to make the system complete as per the specifications. Filteration Rate 14000L/Sqm/Hr Test pressure 4.5 Kg/Sq.cm Working pressure 3.5 Kg/Sq.cm Maximum pressure 4 Kg/Sq.cm Media Depth to be minimum 150 mm coarse sand, 200mm fine sand and 200mm anthracite. Diameter- 700 mm

1

-

120000

... More
Activated Carbon Filter: Supply, installation , testing & commissioning of MSEP filter complete with initial charge with pebbles, anthracite, media , connecting with multiport valve (for controlling all operations for rinsing, backwashing, service etc under automated system linked with differential pressure transmitter and differential guage), glycerine filled pressure gauge at inlet, outlet and back wash (each with isolation cock), complete as required with sand blasted inside and outside, finished with 6-8 mm thick epoxy lining reinforced and including wiring and anunciation complete as required(Thinner plate for shell and dished ends not acceptable) complete as required and all other accessories required to make the system complete as per the specifications. Filteration Rate 14000L/Sqm/Hr Test pressure 4.5 Kg/Sq.cm Working pressure 3.5 Kg/Sq.cm Maximum pressure 4 Kg/Sq.cm Media Depth to be minimum 150 mm coarse sand, 200mm fine sand and 500mm activated carbon. Diameter- 700 mm

1

-

130000

... More
Supplying, installing, testing and commissioning of chlorine dosing system consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing pump having variable flowrate. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary agitator, polypropylene piping, valves, strainers, low level switch(Range 0-600mm) and injection fittings. The pump shall be speed & stroke control. (Pump to be with one working and one stand by assembly). Flow rate : 0-12 lph

1

-

24000

... More
Supplying, installing, testing and commissioning of PH Correction dosing system consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing pump having variable flowrate. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary agitator, polypropylene piping, valves, strainers, low level switch(Range 0-600mm) and injection fittings. The pump shall be speed & stroke control. (Pump to be with one working and one stand by assembly). Flow rate : 0-12 lph

1

-

24000

... More
Providing & fixing on line turbine type flow meter of following sizes with preamplifier & microprocessor based electronic flow meter mounted in plumbing plant room electrical control panel with the following features. Monitoring the total flow, Flow rate, high low arm batching and blending etc. Including electrical wiring from preamplifier to microprocessor based flow meter. Complete with all type of Plumbing & Electrical connections, accessories, wiring, conduits & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received on BAS. Flow Rate Range : upto 1000 LPM Temperature Range : upto 85 degree celcius. Pressure Range : upto 50 bar Material of construction: Stainless steel IP Rating: IP 67 for transmitter and IP 68 for senser. Accuracy : 1 % on positive and negative side.

2

-

35000

... More
Supplying, Installation, Testing and Commisioning of Water level indicators cum controllers of Stainless Steel Probe with Digital display panel for installation on storage tanks, and capable of providing 4 to 20 mA analog signal compatible with PLC signal inputs ( probe should be provided with 20m cable with no connection joints in single run) and complete as per working requirements . All analog output from probe should be indicated in digital output panel placed in MCC panel and wiring should be done for interlocking , auto start / stop of pump complete as per specifications and as required. Including annunciation and indication panel with interlocking arrangement complete in accordance to specification with level indicator (for Borewell line to raw tank and filter feed line to dom. tank , : High / Low Level Controller) etc with control cabling from field to MCC as required. Vender needs to submit IO summary prior to finalization for approval.

4

-

22000

... More
Supplying, Installation, Testing and Commisioning of online TDS meter suitable for fixing at domestic water treatment station for online monitoring of water quality and inlet and oulet, equipment shall be provided with Built-in non-volatile memory,local display, Automatic Temperature, Compensation, Password Protected, IP - 67 rating, measuring following range , including cable termination for controlling and alarming complete as per specifications ( cost of cabling and end termination shall be paid under relevant subhead) 0 to 3000 ppm

1

-

38000

... More
Supplying, Installation, Testing and Commisioning of online Ph meter suitable for fixing at domestic water treatment station for online monitoring of water ph level at outlet of treatment station, equipment shall be provided with Built-in non-volatile memory,local display, Automatic Temperature, Compensation, Password Protected, IP - 67 rating, measuring range 4 to 12 ph , including cable termination for controlling and alarming complete as per specifications ( cost of cabling and end termination shall be paid under relevant subhead). The meter to be set at a range of 6.5 to 8 ph level with automatic linkage with the ph correction dosing system to control ph level.

1

-

45000

... More
Tube Settler Media: Providing, fixing, testing and commissioning of PVC tube media including all fitting and accessories.

1

-

28000

... More
MBBR Reactor Media: Providing, testing and commissioning of MBBR Media (Transchip/Quachip media) in MBBR reactor including all fitting and accessories.Media surface 5500 sqm./m3

1

-

140000

... More
Sludge Dewatering System : Supply, installation, testing and commissioning of manually operated filter press of Suitable Capacity with CI frame, PP plates complete with filter cloth complete with Filter press feed pump (Screw Type) – 2 No. (1 working + 1 standby) with 1 No. standby stator, interconnecting piping complete as required.

1

-

124000

... More
Supply, installation, testing and commissioning of the UV unit of flow rate 7500 LPH consisting of reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lampout alert, UV radiometer along with UV monitoring system and UV monitoring readout panel (Intensity monitor required which shows the life cycle remaining since commissioning, Lamp replacement indicator, lamp failure indicator etc.). The UV Dosage should be 60,000 uW – Sec / sq.cm. The lamps should be selected based upon the flow requirement of respective unit. The unit shall be complete with temperature safety control, lamp out alert circuit & UV radiometer with 4 – 20 mA output and auto cleaning feature. The treatment chamber shall be SS 316.

1

-

168000

... More
Supply, installation, testing and commissioning of the UV unit of flow rate 15000 LPH consisting of reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lampout alert, UV radiometer along with UV monitoring system and UV monitoring readout panel (Intensity monitor required which shows the life cycle remaining since commissioning, Lamp replacement indicator, lamp failure indicator etc.). The UV Dosage should be 60,000 uW – Sec / sq.cm. The lamps should be selected based upon the flow requirement of respective unit. The unit shall be complete with temperature safety control, lamp out alert circuit & UV radiometer with 4 – 20 mA output and auto cleaning feature. The treatment chamber shall be SS 316.

1

-

280000

... More
Supply of MS hot dip galvanized puddle flanges in accordance to BS:10 table D as required to be provided (in the structural slab and wall) of various diameters. Puddle flanges shall be provided for all the structural component of the STP. The installation of the puddle flanges shall be carried out by the Civil contractor in accordance to the Civil GA drawing (to be prepared by the STP contractor) at the required levels & position; under the supervision of the STP contractor.

1

-

45000

... More
Supply of plastic manhole step/foot rest (@ 300 mm c/C) with polypropelene compound injection molded around 12 mm dia (Fe-415) steel reinforcing bar. Provision of the foot rest is envisaged in various tanks/ components of the STP for the purpose of accessability. The installation of the foot rest shall be done by the civil contractor as per civil GA drawing

20

-

500

... More
Approval from pollution board at initial & various other stages of works including preparation of report / drawings as per pollution board requirement, arrangement of raw sewage for testing & commissioning. Contractor shall include the cost of all chemicals (consumed during testing & commissioning and the cost of such items of works which are not explicitly mentioned above, but are mendatory to have pollution board approval.

1

-

24000

... More
Supplying, installing, testing and commissioning of Electronic ozonator 100-120 gram/hr. discharge capacity, completely in SS with electronic power supply invertor with latest ozone technology to generate high capacity ozone with minimum power consumption and minimum break down. The system to be with SS 316 electro polished ozone cell, SS 316 electro polished ozone injector(ejector) with SS 316 Non return valve, silicon / teflon tubing 1/4" x 5 meter. All contact parts to be either in SS 316 electro polished or teflon.

1

-

400000

... More
Control Panel: Design, Fabrication,Supply, Installation, Testing and Commissioning of following Wall mounted / Floor mounted(including base stand), 415V,3PH, 50Hz extensible and fully compartmentalized panels complying to IS 8623/93. The indoor panels shall be IP 42 and outdoor panels shall be IP 54 type.The Panel shall have proper space with required clearance for cables, incoming / outgoing switchgear, CTs, PTs, ammeter, Voltmeter, selector switches, Insulated and properly supported compartmentalized bus bars with heat shrinkable sleeves along with the other control circuit accessories within the panel and any other electrical component mentioned in the Panel SLD.The panel shall be fabricated out of CRCA not less than 2.0 mm thick for load bearing members and 1.6mm for the doors of LT panel.The Panel shall have seven tank pre treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having a paint thickness of 60 microns or as specified.The Panel shall be Dust/Vermin poof with earth studs as per the SLD and specifications, Panel should be BAS compatible.Notes: Necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also be included. All MCCBs shall be of 25 KA breaking capacity and suitable for motor duty application. All motor starter shall be provided with Automatic level controller. Adequate number of spares to be left in conjunction with the engineer in charge. Provision shall be made for providing potential free contacts to all pumps starters for connection to BAS.

1

-

280000

... More
Design, Fabrication,Supply, Installation, Testing and Commissioning of following Wall mounted / Floor mounted(including base stand), 415V,3PH, 50Hz extensible and fully compartmentalized panels complying to IS 8623/93. The indoor panels shall be IP 42 and outdoor panels shall be IP 54 type.The Panel shall have proper space with required clearance for cables, incoming / outgoing switchgear, CTs, PTs, ammeter, Voltmeter, selector switches, Insulated and properly supported compartmentalized bus bars with heat shrinkable sleeves along with the other control circuit accessories within the panel and any other electrical component mentioned in the Panel SLD.The panel shall be fabricated out of CRCA not less than 2.0 mm thick for load bearing members and 1.6mm for the doors of LT panel.The Panel shall have seven tank pre treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having a paint thickness of 60 microns or as specified.The Panel shall be Dust/Vermin poof with earth studs as per the SLD and specifications, Panel should be BAS compatible. Refer the SLD for relevant information. The item is inclusive of all electrical cables, cable trays, end terminations, earthing etc required to complete the job. Notes: 1. All the starter components should be from a single manufacturer and the starter components must be selected as per Type-II coordination of respective OEM. 2. Illuminated push button to be provided on starter feeders. 3. All control & power wiring from all components such as switchgears, meters, relays etc. shall be brought-out upto the terminal blocks inside cable alley.1 x Type 2 surge arrester with suitable Fuse. 1 x R,Y,B LED indication lamp with 2A control MCB 1 x 250 A, FP, 25kA, MCCB with LSIG protection 1 x On, Off, Trip indication 1 x ( Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of at least KWH/KVAH, V, A, PF with 5VA CTs of required ratio) Busbar : Suitable for 250A, 415V, FP, 25 kA/sec, Aluminium busbar. Outgoings : R,Y,B LED indication lamp with 2A control MCB for each outgoing 2 x 1.50 kW direct online starter, 4A TP 50kA, MPCB with OLR range 2.8-4A SPP, 16A delta contactor, with ammeter & ammeter selector switch, including start, stop, on, off, trip & auto/manual push buttons. 2 x 3.5 kW direct online starter, 8A TP 50kA, MPCB with OLR range 5.5-8A SPP, 16A delta contactor with ammeter & ammeter selector switch, including start, stop, on, off, trip & auto/manual push buttons. 20 x 16 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic based release. 2 x 25 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic based release. 3 x 40 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic based release.

1

-

486200

... More
Horticulture-Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).

1061.11

-

274.2

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation .75 mm

1029.9

-

197.5

... More
Fine dressing of the ground.

10403

-

1.9

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

3120.9

-

27.55

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

3120.9

-

27.56

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep

267

-

61.2

... More
Same as above item but Holes 60 cm dia, and 60 cm deep

3538

-

19.25

... More
Half brick circular tree guard in bricks, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses being in dry honey comb masonry as per design complete:With common burnt clay F.P.S. (non modular) bricks of class designation 5

267

-

1364

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)Trees Plant

267

-

3.75

... More
Same as above item but Shrubs Plant

3538

-

1.85

... More
Providing and displaying of Brassia Variegated having ht. 30 cm to 45 cm, well developed with fresh and healthy foliage in 25 cm size of Earthen pot /Plastic pot. & as per direction of the officer-in-charge.

99

-

114.14

... More
Providing and displaying of Croton Duck Foot (Elite) having ht. 60 cm to 75 cm with 4 to 5 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

49

-

309.98

... More
Providing and displaying of Raphis palm specimen having ht. 1.50 m to 1.65 m with 40 to 50 lush green suckers, well developed, fresh & healthy foliage leaves in 40 cm size of Earthen Pot/Chali/Tray & as per direction of the officer-in-charge.

53

-

509.71

... More
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

12

-

57.6

... More
Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

15

-

62.4

... More
Providing and stacking of Jacaranda mimosifolia of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

11

-

57.6

... More
Providing and stacking of Washingtonia filifea palm stem ht. 120-135 cm with 8-10 healthy leaves lush green leaves well developed in big size HDPE Bags as per direction of the officer-in-charge.

21

-

624

... More
Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.

7

-

216

... More
Providing and stacking of Hamelia patens of height 90-105 cm. bushy in big size HDPE bags as per direction of the officer-in-charge.

128

-

96

... More
Providing and stacking of Thevetia nerifolia of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm as per direction of the officer-in-charge.

250

-

43.2

... More
Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge.

3160

-

14.78

... More
Grassing with selection No. 1/ Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).With grass Turf

10403

-

6.95

... More
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.

10403

-

195

... More
Road Work -Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil

5791.29

-

79.56

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.

20761.09

-

71.78

... More
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.

150

-

1299.78

... More
Painting road surface marking with adequate Nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. New work (Two or more coats)

364.42

-

185.65

... More
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge

105

-

738.78

... More
Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

58.36

-

7200.95

... More
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).

692.04

-

7447.6

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

743.04

-

2164.46

... More
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin- charge.

457.66

-

3337.22

... More
Boundary wall -Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil

799.99

-

156.34

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

573.27

-

188.83

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)

57.32

-

4745.79

... More
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).

689.19

-

360.13

... More
Extra for providing and mixing water proofing material in cement concrete per 50 kg work in doses by weight of cement as per manufacturer's specification.

206.76

-

48.62

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete

353.43

-

244.88

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

1098.71

-

474.6

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

1032.98

-

630.76

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level

169.4

-

6875.26

... More
Same as above item but All works above plinth level upto floor V level

72.88

-

8081.89

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.

21665.65

-

71.78

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more.

9897.64

-

71.78

... More
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineerin- Charge. (The payment of RCC band and reinforcement shall be made for seperately).

466.53

-

5705.77

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

8192.4

-

87.47

... More
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm

1024.44

-

89.11

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)

2028.39

-

218.58

... More
15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand)

2028.39

-

264.7

... More
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)

1865.51

-

195.45

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers

409.78

-

51.37

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

5922.29

-

138.54

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

399.53

-

163.13

... More
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)

998.83

-

250

... More
Gate-Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

262.79

-

87.47

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1266.53

-

112.62

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

538.56

-

494.71

... More
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

120

-

72.09

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

122.64

-

152.3

... More
Guard room-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil

105.84

-

156.34

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

70.65

-

188.83

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

7.39

-

1679.03

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).

11.04

-

5380.93

... More
Same as above item but 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)

4.62

-

4745.79

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge.

23.18

-

7220.3

... More
Same as above item but All works above plinth level upto floor V level

20.29

-

8426.93

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete

38.4

-

244.88

... More
Same as above item but Columns, Pillars, Piers, Abutments, Posts and Struts

81.12

-

630.76

... More
Suspended floors, roofs, landings, balconies and access platform

74.56

-

595.81

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.

6575.62

-

71.78

... More
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

16.18

-

7073.03

... More
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineerin- Charge. (The payment of RCC band and reinforcement shall be made for seperately).

27.04

-

5705.77

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

42

-

584.47

... More
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames

12.6

-

2978.89

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

7.56

-

1621.99

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Fixing with adjustable lugs with split end tail to each jamb

20.8

-

382.01

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :

55.92

-

1316.93

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.18 mm thick.

7.94

-

1556.1

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.

5.76

-

796.85

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

25.5

-

885.75

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

4

-

209.81

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer

224.5

-

51.58

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats

224.5

-

70.41

... More
Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm)

191.88

-

78.45

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes110 mm diameter

12

-

262.25

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°110 mm bend

4

-

111.63

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm

12

-

248.28

... More
Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.

4

-

86.36

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lid

4

-

4419.32

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap

4

-

2020.2

... More
Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm.75 mm diameter (minimum wall thickness 3.2mm)

8

-

242.43

... More
Same as above item but 110 mm diameter (minimum wall thickness 3.2mm)

8

-

422.97

... More
Providing and fixing uPVC trap of self cleaning design complet. Including cost of cutting and making good the wall and floors.100 mm inlet and 75 mm outlet

4

-

459.94

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe40 mm dia

4

-

86.92

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

4

-

1103.03

... More
Providing and fixing toilet paper holder :Vitreous china

4

-

366.36

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

4

-

112.19

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25 mm nominal outer dia Pipes

24

-

317.4

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15 mm nominal outer dia Pipes

8

-

207.66

... More
Same as above item but 20 mm nominal outer dia .Pipes.

8

-

263.88

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

-

7.57

... More
Providing and fixing brass bib cock of approved quality :15 mm nominal bore

4

-

531.98

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893 115 mm nominal bore

4

-

457.36

... More
FIRE PROTECTION WORKS-Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads.2850 lpm at 88 m Head

2

-

387509.46

... More
same as above item but 2850 lpm at 56 m HeadNote: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point

1

-

345373.11

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.2850 lpm at 88 m Head

1

-

587306.57

... More
Same as above item but 2850 lpm at 56 m HeadNote: * The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point

1

-

525809.83

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered180 lpm at 88 m Head

2

-

108523.9

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)Horizontal type, multistage, centrifugal, split pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.900 lpm at 35 m Head

1

-

86783.01

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable foroperation on 415V, 3 phase, 50Hz Ac Supply wit enclosure protection class IP 42 as required :Incomings 800A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-800 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 1000AmpsOutgoings ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 setsJockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 setsDIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification.

1

-

494937.24

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.150 mm. Dia

395

-

2042.64

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia

10500

-

404.92

... More
Same as above item but 32 mm dia

4500

-

453.06

... More
Same as above item but 40 mm dia

3500

-

559.66

... More
Same as above item but 50 mm dia

2850

-

676.58

... More
Same as above item but 65 mm dia

2650

-

863.14

... More
Same as above item but 80 mm dia

2200

-

964.58

... More
Same as above item but 100 mm dia

1400

-

1288.69

... More
Same as above item but 150 mm dia

1350

-

1774.42

... More
Same as above item but 200 mm dia (wall thickness 6.3 mm)

50

-

2515.47

... More
Same as above item but 250 mm dia (wall thickness 6.3 mm)

15

-

3026.99

... More
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm

105

-

1398.73

... More
Same as above item but 150 mm

350

-

1950.65

... More
Supplying and fixing single headed internal hydrant valve with instantaneous unmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel

57

-

5147.01

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel

10

-

5147.01

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :40mm dia

10

-

3016.68

... More
Same as above item but 50 mm dia

10

-

3155.95

... More
Same as above item but 65 mm dia

10

-

3566.88

... More
Same as above item but 80 mm dia

15

-

4162.65

... More
Same as above item but 100 mm dia

15

-

5548.49

... More
Same as above item but 150 mm dia

20

-

7478.51

... More
Same as above item but 200 mm dia

5

-

12859.35

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :200 mm dia

3

-

33642.54

... More
Same as above item but 250 mm dia

2

-

39819.46

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

10

-

1109.87

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :65 mm dia

2

-

5393.74

... More
Same as above item but 100 mm dia

2

-

9315.68

... More
Same as above item but 150 mm dia

4

-

15110.9

... More
Same as above item but 250 mm dia

1

-

38756.02

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.80 mm dia

2

-

3931.4

... More
Same as above item but 100 mm dia

1

-

5545.05

... More
Same as above item but 150 mm dia

1

-

9163.51

... More
Same as above item but 200 mm dia

3

-

18958.05

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)

134

-

3811.9

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m

57

-

8676.07

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304)

67

-

1416.78

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :4 way - 150 mm dia M.S. Pipe

3

-

11882.74

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

2

-

15482.29

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler

1200

-

416.09

... More
Same as above item but Upright Sprinkler

2600

-

416.09

... More
Same as above item but Horizontal side wall sprinkler

150

-

497.76

... More
Same as above item but Concealed sprinkler

200

-

1201

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

42

-

1296.42

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.150mm dia

42

-

7624.66

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :150 mm dia

5

-

41177.79

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.700 mm

200

-

1152.85

... More
same as above item but 1200 mm

300

-

1403.89

... More
Supplying, installation, testing & commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required 80 mm dia

9

-

71323.93

... More
Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.

30

-

569.98

... More
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solenoid valve, weather proof operation on 24 volts DC supply complete as required.

9

-

6302.44

... More
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

1550

-

177.96

... More
Supplying, fixing, testing and commisioning of female screwed end Full bore lever operated Forged brass ball valve(PN 16) having forged brass stem, carbon steel nut, carbon steel washer, carbon steel lever, forged brass body and gland nut, PTFE gland packing and body seat ring, forged brass bonnet and ball with (threaded joints) complete as required with nuts, bolts, gaskets, washers, plastic sleeve over handle etc.. The body of the valve to be tested to a pressure of 24 Kg / sqcm and seat pressure to be 17.6 kg/sqcm for metal seated valves. 40 mm nominal bore

15

-

1027

... More
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner).Providing & fixing ISI marked portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres conforming to IS: 2878 with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets.

71

-

2310

... More
Providing & fixing ISI marked (IS:2878) portable CO2 type fire extinguisher type 4.5 kg capacity. Including valve, discharge hose of not less than 10 mm dia & 1 M long complete in all respects including initial filled with CO2 gas confirming to IS:307-1966 & filled to a filling rate of not more than 0.667 and wall suspension bracket.

71

-

4147

... More
Providing & fixing of ABC Type, Portable Fire Extinguisher, dry powder type (Gas Cartridge) conforming to IS: 15683 : 2006 with cylinder initially fully charged with dry powder, ISI marked confirming to IS:15683 : 2006 complete with standard discharge valve with tube, CI bracket for wall mounting.4 Kg

71

-

1207

... More
Same as above item but 9 Kg

10

-

1837

... More
Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and conforming to IS:910.9 Litres

10

-

2257

... More
Same as above item but 50 Litres (trolley mounted)

5

-

6562

... More
Electrical work-HT Equipments Sub station Eqpts Bus trunking Rising Mains 11 KV HT VCB SIX BREAKER EXTENDABLE BOTH SIDES PANEL BOARD (INDOOR TYPE) (2 INCOMMING + 1 BUS COUPLER + 3 OUTGOING)Supply, Installation, Testing & Commissioning of 11 KV Eight Breaker Vacuum Circuit Breaker Panel Board as 2 Incomming, 1 Bus Coupler & 5 Outgoing shall be metal clad floor mounting complete as per specification and as described.INCOMING PANEL - 2 NO. (Each outgoing feeder shall have following)630 A Vacuum circuit breaker of 31.5 KA RMS for 3 second ruputuring capacity for at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.3 No. Single Phase double core current transformer 200/5 Amp epoxy cast insulated class of insulation E.Core 1-15VA burden class 1.0 for metering.Core 2-15VA burden class 5P10 for protection.P.T's of 11KV/1.732, 110V/1.732, 100VA with suitable rating H.T. & L.T. fuse conforming to relevant IS Standards and complete as required.One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements. 1 No. Anti Pumping device.1 No. Circuit breaker control switch for electrical (T/N/C).1 No. limit switch for test & service position.1 No. Voltmeter (0-15KV) with selector switch. (96mm square)1 No. Ammeter (0-200Amp) with selector switch. (96mm square).1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories. 1 Set of following indicating lamps.Red, Yellow & Blue for phase indication.Amber for Trip indication.Red `ON' Green `OFF'Spring charge indication.Auto trip indication.1 No. hooter with hooter acceptance and reset push button.1 No. master trip relay. (Electromechanical Type )1 No.Trip ckt supervision relay. (Electromechanical Type ) 600A color coded heat shrinkable sleeved TP Copper busbar of 350 MVA fault rating.1 Set of fuses, ferrules, wiring etc. as required.1 Set of Power Pack 220 Volt A.C. / 24 Volt D.C. complete as required. Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.BUS COUPLER - 1 NO. 630 A Vacuum circuit breaker of 31.5 KA RMS for 3 second ruputuring capacity for at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following. Electrically operated, spring charged (release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication"OFF" push buttons for emergency trip (shrouded) test/service position limit switches with 6 NO/6 NC breaker auxilliary contacts in service position, 24 Volts DC shunt trip coil and strip heater to prevent moisture absorption. 1 Set of following indicating lamps.Red, Yellow & Blue for phase indication.Amber for Trip indication.Red `ON' Green `OFF'Spring charge indication.Spring charge indication.Auto trip indication.The two Incomer and Bus Coupler shall be electrically / mechanically interlockedOUTGOING PANEL - 3 NOS. (Each outgoing feeder shall have following)630 A Vacuum circuit breaker of 31.5 KA RMS for 3 second ruputuring capacity for at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.3 No. Single Phase double core current transformer 100/5 Amp epoxy cast insulated class of insulation E.Core 1-15VA burden class 1.0 for metering.Core 2-15VA burden class 5P10 for protection.One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements. 1 No. Anti Pumping device.1 No. Circuit breaker control switch for electrical (T/N/C).1 No. limit switch for test & service position.1 No. Voltmeter (0-15 KV) with selector switch. (96mm square)1 No. Ammeter (0-100 Amp) with selector switch. (96mm square).1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories. 1 Set of following indicating lamps.Red, Yellow & Blue for phase indication.Amber for Trip indication.Red `ON' Green `OFF'Spring charge indication.Auto trip indication.1 No. hooter with hooter acceptance and reset push button.1 No. master trip relay. ( Electromechanical Type) 1 No.Trip ckt supervision relay (Electromechanical Type) 1 Set of fuses, ferrules, wiring etc. as required.4 No. VAA33 auxiliary relay for transformer fault, alarm and trip.12 Annunciator window for all electrical and transformer fault.Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm. Cost of relays etc required at transformer shall be included in the cost of Panel.H.T. Panel describe as above

1

-

2400000

... More
1250 KVA, 11 KV/433V DRY TYPE TRANSFORMER-Supplying, Installation, Testing and Commissioning of Cast Resin Dry Type 1250 KVA, 11/0.433KV, 3 Phase, 50 Hz, Dyn11 vector group, copper wound, class F insulation associated with winding temperature indicator/controller actuated by means of resistance temperature detector embedded in LV windings, INDOOR TYPE transformer with approximately 6.5% impedance, tappings for off load operation on HV side in step of +/- 2.5%, +5.0% to -7.5%, having cable end boxes on HV side suitable for 3C x 240 sq. mm XLPE cable of 11 KV grade and 2500 A TPN Aluminium Bus Duct connection on LV side with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker for safety tripping, suitably mounted on M.S. channel i/c supplying and grouting of suitable M.S. channel with all accessories and confirming to IS 11171:1985 & as per specification attached complete in all respects as required at site. Transformer Losses shall be as per ECBC plus losses of latest ECBC Code-2017.1250 KVA 11/0.433KV Dry transformer with on load tap changer and RTCC Panel, conforming to losses of ECBC plus as per ECBC

3

-

2500000

... More
11 KV END TERMINATION:supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 sq. mm

10

-

10042.13

... More
11 KV H.T. CABLE:Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required.3C x 240 Sqmm, 11 KV XLPE

200

-

1115.5

... More
Laying of one number XLPE power cable of 33 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

160

-

414.37

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

25

-

96.29

... More
Laying of one number XLPE power cable of 33 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

40

-

99.72

... More
Supply of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant).4 core, 1.5 sq.mm.

500

-

84.7

... More
same as above item but 8 core, 1.5 sq.mm.

800

-

142.08

... More
same as above item but 12 core, 1.5 sq.mm.

1000

-

209.71

... More
Supplying, installation, including suspension, testing and commissioning of following capacity bus trunking with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections for use on, 3 phase, 4 wire, 415 V, 50 Hz, A.C. supply including jointing of sections, flexible joints, expansion joints, bends and earthing with 2 runs of galvanised iron strips, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.2000 A 50kA SC for 1 sec

200

-

19015.65

... More
Same as above item but Extra for providing weather proofing canopy and making item 8.1 IP 56 rated , suitable for outdoor use

80

-

3000

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm atnominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.400 A 50kA SC for 1 sec (UPS) ( 2 no rising mains for Block A )

56

-

10335.28

... More
same as above item but 800 A 50kA SC for 1 sec

56

-

13371.73

... More
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required63 A , 16 kA SC for 1 sec ( UPS Tap off: 18, )

18

-

5465.96

... More
Same as above item but 200 A 25kA SC for 1 sec ( L+P Panel tap off: 16 , solar power panels at block A terrace : 2 nos, , basement panels :4 nos)

22

-

6918.84

... More
Same as above item but 400 A, Isc= 35kA for 1 sec

2

-

8897.87

... More
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with rovision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required400 A 30kA SC for 1 sec

2

-

6281.81

... More
same as above item but 800 A 50kA SC for 1 sec

2

-

9471.29

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes cubicle panel, making connections, etc. as required.63 A, 16 kA,TPMCCB

18

-

3203.23

... More
same as above item but 200 A, 25 KA, TP MCCB

22

-

9416.27

... More
same as above item but 400 A, 35 KA,TPMCCB

2

-

18493.81

... More
same as above item but 800 A, 50 KA,TPMCCB

2

-

29105.06

... More
DG SETS-Design, Manufacturing, Testing at works, Supply, Installation, Testing & Commissioning of 'Silent Type' Diesel Generating Set along with having prime power rating 1000 KVA, 415 Volts at 1500RPM, 0.8 lagging Factor at 415 V suitable for 50 Hz, 3 phase system and for 0.85 load factor and consisting of the following:-Diesel EngineDiesel Engine 4 stroke radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 400C, 50% RH & at 1000 metre MSL and confirming to BS 5514, BS 649, is 10000, capable of taking 10% overloading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories.Engine Mounted Instrument Panel fitted with and having digital display for following:Start- stop switch with key.Water Temperature indicationLubrication Oil pressure indication Battery charging indication RPM indication Over Speed trip Indication Low lubrication oil trip indication Engine Hours Indication Alternator:Synchronous alternator rated at 1000 KVA, 415 Volts at 1500 RPM, 3 phase 50 Hz, AC Supply with 0.8 lagging power factor at 400C, 50% RH & at 1000 metre MSL. The alternator shall be having SPDB enclosure, brushless, continuous duty, self-excited and self-regulated through AVR confirming to IS:4722/ BS 2613 suitable for tropical conditions and with class- F insulation. Alternator shall have end termination of 2000A Aluminium Bus Duct.Base Frame & Foundation Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.Fuel Tank:Daily service fuel tank of 990 litres capacity, fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C pipes of suitable dia. Complete with valves level indication & accessories as required as per specifications.Exhaust System :Dry exhaust mainfold with hospital grade exhaust silencer.Starting System:24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with 2 Nos. of batteries (25 plates, 360 AH lead Acid type) as required as per specifications.Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per specifications.Cooling system : Remote Radiator ( mounted on roof of Canopy of DG set) including al interconnections, piping, valves, pumps etc as required Control wiring as required Auto operation /synchronization of DG sets providing PLC based controller etc for auto operation and synchronization of DG sets ( out put of Dg set to be directly fed to Main LT PaneL )

2

-

6350520

... More
EXHAUST PIPING Supply, Installation, Testing and Commissioning of following sizes MS exhaust piping heavy duty conforming to IS:3589 complete with all accessories such as bends, flanges, stainless steel flexible bellows etc. as required.300 mm dia MS pipe. (6.0 mm thick)

100

-

4530.61

... More
Supply & Fixing of Insulation of above pipe with 50 mm thick Loosely bound resin (LBR) mattress/ mineral wool/ Rockwool, density not less than 120 kg/m3 and aluminium cladding of 0.63 mm thick on exhaust pipe complete as per technical specification. 300 mm dia MS pipe.

100

-

3685.39

... More
Supply & Fixing of following size of Stainless Steel expansion bellows for DG Set exhaust pipe.300 mm

2

-

15443

... More
Providing and fixing of inspection window in D.G. Exhaust Pipe as per requirement of pollution control board.

2

-

5000

... More
Ddesign ,fabrrication, fixing/installation on existing wall/Rcc foundation MS structure ans required for support of Chimney or any other item , including primer, painting etc complete

2000

-

116

... More
UPS SYSTEM -Supply, Installation, Testing & Commissioing of 4*100 KVA UPS in paralleling mode at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet and MODBUS, Inbuilt input Isolation transformer as per specification given in the document with following broad features. THD(i) shall be less than 3% in the entire loading range.UPS shall carry design output at 40 deg.Shall have soft start and hold of for incoming supply.Invertor capability to supply 150% load for 5 sec. Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.)Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.4 sets of Battery shall be external type with rack and suitable for 15 minute backup on 100% load. Battery management kit shall be provided. In case of 25% load battery back up shall be available for 60 minutes.Suitable size of copper cable between UPS and battery bank shall be providedUPS shall be compatible for 4 nos unit of 100 KVA in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.

1

-

4627022.77

... More
LIFT SYSTEM-PASSENGER LIFT-Supplying, Installation, Testing & Commissioning of 20 Passenger (1360 Kg) Lifts (Gearless), MRL having contract speed of 1.0 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-Speed -- 1.0 MPS,Floors -- B+G+7,Travel -- 34 Mtrs Approx.Stops & door opening - -- 9 /1000 mm WideX 2100mm High. Controller: A.C. variable voltage & variable frequency drive.Automatic rescue device complete with dry maintenance free batteries as required. Operation: Microprocessor based single automatic push butt on/Duplex selective collective with / without attendant.Power-415 V, 3 phase, 50 Hz, 4 wires system.Type of doors(i) Car Power operated, architectural Stainless Steel (SS 304 Grade)(ii) Landing doors : architectural design Stainless Steel scratch resistant . (SS 304 Grade)Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.The Lift shall be provided with Brail System.Ceiling as per manufacturer's standards with Fan & LED Lights. On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.IP based CCTV interfaced to be provided.BMS interface for lift position & 3 way Intercom system.2 Hour Fire rated door. Manufacturer shall be submit the certificate alongwith supply of material from NABL approved Lab.Lift described as above

4

-

1968750

... More
PASSENGER cum Bed Lifts-Supplying, Installation, Testing & Commissioning of 20 Passenger (1360 Kg) Lifts (Gearless), MRL having contract speed of 0.75/1.0 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:- Speed Travel -- 34 Mtrs Approx. -- 1.0 MPS Floors -- B+G+7 Stops & door opening - -- 9 /1000 mm WideX 2100mm High Controller: A.C. variable voltage & variable frequency drive.Automatic rescue device complete with dry maintenance free batteries as required. Operation: Microprocessor based single automatic push button/Duplex selective collective with / without attendant.Power-415 V, 3 phase, 50 Hz, 4 wires system Type of doors (i) Car Power operated, architectural Stainless Steel (SS 304 Grade)(ii) Landing doors : architectural design Stainless Steel scratch resistant . (SS 304 Grade)Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.The Lift shall be provided with Brail System.Ceiling as per manufacturer's standards with Fan & LED Lights. On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.IP based CCTV interfaced to be provided.BMS interface for lift position & 3 way Intercom system.2 Hour Fire rated door. Manufacturer shall be submit the certificate alongwith supply of material from NABL approved Lab.Lift described as above

2

-

1968750

... More
Passenger Lift-Supplying, Installation, Testing & Commissioning of 1000 KG Passenger cum Goods lifts (Gearless), Machine Room Less having contract speed of 1.0 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-Speed -- 1.0 MPS Floors -- B+G+1Travel -- 8.5 Mtrs Approx.Stops & door opening - -- 3/1000 mm WideX 2100mm High Controller: A.C. variable voltage & variable frequency drive.Automatic rescue device complete with dry maintenance free batteries as required. Operation: Microprocessor based single automatic push button/Triplex / Quard selective collective with / without attendant.Power-415 V, 3 phase, 50 Hz, 4 wires system Type of doors (i) Car Power operated, architectural Stainless Steel (SS 304 Grade) (ii) Landing doors : architectural design Stainless Steel scratch resistant . (SS 304 Grade)Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.The Lift shall be provided with Brail System.Ceiling as per manufacturer's standards with Fan & LED Lights. On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.IP based CCTV interfaced to be provided.BMS interface for lift position & 3 way Intercom system.2 Hour Fire rated door. Manufacturer shall be submit the certificate alongwith supply of material from NABL approved Lab.Lift described as above

2

-

1744955.49

... More
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM-Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 20%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type.Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 325 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conditions. The solar panel shall be complience of IEC 61215, IEC 61730 certified by TUV Rheinland / UL. The solar panel shall be installed as per BOQ & detailed technical specification.

200

-

56000

... More
MS structure complete including structural design , grouting, welding, primer, painting etc as required at mumty level for mounting grid structure of Solar system at about 3 mtr height from terrace

10000

-

116

... More
Panels and DB-AIN L.T. /CAPACITOR PANEL - AS PER IEC 61435-Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & commissioning of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, compartmentlized, front operated, electrical panel fabricated from 2 mm thick M.S. Sheet as per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indication lamps, CT's, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 70 micron thickness. All the busbar joint shall be protected by clip on type sleeve. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have changeover facility & interlocking through PLC to achieve electrical interlocking, buscoupler switching, auto operation of incommer and bus coupler etc and having following incomming and outgoing Air Circuit Breakers, MCCB as per the drawing and specification. Fault level shall be 50 KA.(Each Incomming MCCB shall have microprocessor release and variable current setting from front, adjustable overcurrent, short circuit & earth fault protection, front extended lockable handle, pad lockable in off position, shrouding on incomer side, termination shall be suitable for aluminium bus bars / cables and as per specification.)INCOMING ( from 3 no Transformers, 2 No DG sets )5 No. 2000 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker microprocessor based releases for O/C,S/C & earth fault protection with instantaneous.BUSCOUPLER 2 Nos. 2000Amp FP Electrically operated horizontal drawout type Air Circuit Breaker as buscoupler with interlocking arrangement with incomers. (50 KA).2 Sets of ON/OFF indicating lamps with protection SP MCB's for bus coupler.BUSBARS 2500 Amp TPN busbars of aluminium alloy as per SLD.INSTRUMENTS-5 Nos. Digital Mutifunction V A VA KWH KVAH F Meter with CT's.5 Sets of phase indicating lights (RYB) with protection SP MCB's. (one set for each incoming breaker).5 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).5 Sets trip circuit healthy indicating lamp (one set for each incoming breaker).5 Sets auto trip indicating lamp (one set for each incoming breaker).5 Nos. master trip relay (one for each Incoming Breaker).5 Nos. 3 phase, over voltage & under voltage relay. (one for each Incoming Breaker).2 Nos. 3 phase, phase reversal relay with single phasing preventor.2 Nos. 12 window announciator with hooter, accept & reset push button. BATTERY & BATTERY CHARGER1 No. 24V, 72AH SMF Battery with suitable battery charger for control supply.ARRANGEMENT for AUTO OPERATION OF INCOMERS of Transformers and DG sets and BUSCOUPLER etc based upon availability of SEB supply and Load Auto changeover.Changeover of Incommer and Bus coupler.Interlocking.Necessary hardware shall be provided to achieve above functions including micro PLC with real time clock, digital inputs/outputs, MMI with 2 line display, power supply, auxillary relays, PB's indication etc. & software for the above.Automatic system shall be user friendly and shall have manual override.Operation logic, control & interlocking scheme shall be prepared by panel manufacturer with coordination of consultants.AUTO LOAD MANAGEMENT of OUTGOING FEEDERS HAVING EDO ACB, based upon availability of supply of transformers and DG set in operation Necessary hardware shall be provided to achieve above functions including micro PLC with real time clock, digital inputs/outputs, MMI with 2 line display, power supply, auxillary relays, PB's indication etc. & software for the above.Automatic system shall be user friendly and shall have manual override.Operation logic, control & interlocking scheme shall be prepared by panel manufacturer with coordination of consultants.OUTGOING All outgoing feeder shall be provide with ON / OFF / Trip indication lamp with protection MCB's & digital energy meter with dual RS 485 port.04 Nos 1000 A TP EDO Air Circuit Breaker with microprocessor based adjustable over current, short circuit, earth fault protections. ( for AC Plant, Rising mains 2 nos Block A, Spare 1)06 Nos 630 A TP EDO Air Circuit Breaker with microprocessor based adjustable over current, short circuit, earth fault protections. ( basement Ventilation: 2 Nos - one for GDA portion and another for rest area) ( Block B 1 no, Fire fighting: 1 , spare: 2no) 08 Nos 200A , 35 Ka TP+N Moulded Case Circuit Breaker with thermal magnetic based adjustable over current, short circuit. ( UPS-4 nos, , Lift Panel : 1, spare: 3 no)06 Nos 100A 35 Ka TP+N Moulded Case Circuit Breaker with thermal magnetic based adjustable over current, short circuit. 3 Phase Dual source Energy Meter (RS-485 communication port), required CT's, control wiring etc.( WTP, STP, Street light cum security rooms feeder pillars, temp connections etc) 300 KVAR CAPACITOR BANK PANEL - 03 SET. (EACH SET SHALL HAVE FOLLOWING)-Thyristor-based APFC panel for each transformer shall be provided. Capacitor bank of APFC panel should comprise of 10 KVAR, 15 KVAR, 25 KVAR and 50 KVAR Heavy-duty, MPP, 7% detuned reactor, 525 V, ISI marked capacitors of approved make. Each capacitor bank shall be protected through semiconductor fuse and MCB/MCCB of required rating switchgears. APFC panel shall be capable to keep the PF of the system within range of 0.98 Lead to 0.98 Lag.INCOMING 01 Nos 630 A TP MDO Air Circuit Breaker with microprocessor based adjustable over current, short circuit, earth fault protections.1 Nos. Digital VAF Meter having RS 485 port, with CT's.1 Sets of phase indicating lights (RYB) with protection MCB's.1 Sets breaker 'ON' & 'OFF' indicating lamp.12 Step Automatic Power Factor Correction relay (APFC relay).BUSBARS-800 Amp TPN busbars of aluminium alloy as per SLD.OUTGOING 04 Nos. 125 Amp TP MCCB (35 KA).03 Nos. 63 Amp TP MCCB (35 KA).03 Nos. 32 Amp TP MCCB (35 KA).04 Nos. capacitor duty contactor (one for each 50KVAR capacitor unit).03 Nos. capacitor duty contactor (one for each 25KVAR capacitor unit).02 Nos. capacitor duty contactor (one for each 10KVAR capacitor unit).01 Nos. capacitor duty contactor (one for each 5KVAR capacitor unit).04 Nos. 50 KVAR heavy duty Capacitor with 7% detuned reactor.03 Nos. 25 KVAR heavy duty Capacitor with 7% detuned reactor.02 Nos. 10 KVAR heavy duty Capacitor with 7% detuned reactor.01 Nos. 5 KVAR heavy duty Capacitor with 7% detuned reactor. 10 sets of push button stations Red and Green for manual operation of capacitor units with auto/manual selector switches.1 No. Indicating lamp for each 100 / 50 / 25 / 10 / 5 KVAR capacitor unit to indicate that the unit is 'ON'.1 No. Toggle switch for changing automatic to manual operation of capacitor units.Power factor meter.

1

-

5593280.22

... More
Main L.T. / Capacitor Panel Described as Above.Supply,Installation,Testing and Commissioning of MV cubical type Panel suitable for 415 Volt,3phase,4wire 50Hz AC supply system fabricated in compartmentalized from CRCA sheet steel not less than 2mm thick duly treated with 7 tanks process, powder coated with minimum 60 micron thickness of approved shade and oven dried . It will have a suitable MS base channel powder coated. The panel will be fabricated in transportable sections. The panel shall have a common copper earth bar of size 50 mm x 6 mm at the rear with 2 Nos. earth studs. The LT panel will have suitable arrangement for bus-ducting/ cable termination into various incoming/outgoing switchgear as required . Cable termination will be at suitable terminal block at top/bottom of the panel and from the terminal block to switch, connection will be made with solid insulated strip/PVC insulated copper conductor cable of required current rating as required. current density in bus bar not to exceed 160 amp/sqcm .The panel shall be complete with following switchgear and accessories i/c labelling ( font Size 3 ")Block B Main Panel at basementINCOMING 1 No. 630 Amp TP Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with Single Pole MCB.BUS BARS800 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 6 No. 200 Amp TPN MCCB 10 Ka ( for Basement, G , First, Terrace, spare)3 no 32 Amp TPN MCCB 10 Ka ( for lifts 2 no, spare-1 no) Panel described as above

1

-

302357.31

... More
L+P Panel Block B basement, G Floor, first Floor, terrace INCOMING 1 No. 200 Amp 35 Ka TP Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with Single Pole MCB.BUS BARS250 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.OUTGOING6 No. 100 Amp TPN MCCB 10 Ka6 No. 63 Amp TPN MCCB 10 Ka Panel described as above

4

-

140617.19

... More
Light+Power Panel (Typical) Block A , 2 nos at each Floor ic basement , fed from rising mains-INCOMING-1 No. 200 Amp 35 Ka TP+N Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with Single Pole MCB.BUS BARS 250 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.OUTGOING 4 No. 63 Amp TPN MCCB 10 KA ( for 2 no Power DB's, 1 for Ahu, 1 spare) 4 No. 40 Amp TPN MCCB 10 KA ( for 2 no Light DB's, 2 spare)

18

-

109366.63

... More
Terrace PANEL including Pressurization ( Block A at/near mumty) 1 No. 400 Amp 35 Ka TP+N Moulded Case Circuit Breaker.1 Set of phase indicating lamps with Single Pole MCB.BUS BARS-500 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING2 No. 100 Amp TPN MCCB 10 KA ( for Solar invertor, 1 spare) 4 No. 63 Amp TPN MCCB 10 KA ( for 2 no Power DB's, 2 spare)4 No. 40 Amp TPN MCCB 10 KA ( for 2 no Light DB's, 2 spare)8 No. 32 Amp TPN Motor Protection Circuit breaker with overload and Short circuit 10 KA ( for lift shaft, lift lobby and staircase pressurization fans, spares)8 No. DOL starter suitable for 3 phase motors upto 7.5 KW ( for lift shaft, lift lobby and staircase pressurization fans, spares), NO NC contacts etc as required for auto operation of Press fans

2

-

153052.24

... More
Terrace PANEL ( Block B at/near mumty)1 No. 200 Amp TP+N Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with Single Pole MCB.BUS BARS 250 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 2 No. 100 Amp TPN MCCB 10 KA ( for Solar invertor, 1 spare)4 No. 63 Amp TPN MCCB 10 KA ( for 2 no Power DB's, 2 spare)4 No. 40 Amp TPN MCCB 10 KA ( for 2 no Light DB's, 2 spare)

2

-

112886.95

... More
Basement MAIN VENTILATION PANEL-INCOMING-1 No. 630 Amp , 35 Ka TP+N Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with Single Pole MCB.BUS BARS 800 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 10 No. 100 Amp 35 Ka TPN MCCB 25 KA ( for 8 no Zonal Panels, 2 spare)

1

-

150811.56

... More
Plant rooms VENTILATION PANEL-INCOMING-1 No. 100 Amp TP+N Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with Single Pole MCB.BUS BARS 150 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 4 No. 20 Amp TPN MCCB 10 KA ( for 3 no Supply fans, 1 spare)4 no VFD's having THID not more than 30% , suitable for 3 phase fans upto 5 KW

2

-

123504.7

... More
LIFT PANEL-Block A -INCOMING 1 No. 200 Amp TP+N Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with Single Pole MCB.BUS BARS 250 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 8 No. 32 Amp TP+N Moulded Case Circuit Breaker.8 No. 40 Amp DP Miniature Circuit Breaker.

1

-

76918.51

... More
UPS supply INCOMING cum outgoing PANEL- ( for 4 x 100 KVA extendable to 6*100 KVA) INCOMING : extendable up to to 4 incomers in futures 4 No. 200 Amp 25 KaTP+N Moulded Case Circuit Breaker. 1 Set of phase indicating lamps with Single Pole MCB.BUS BARS 800 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 3 no 400 A MCCB ,25 Ka for Block A ( rising Mains UPS ,spare 1 no) 4 No. 63 Amp 10 Ka TP+N Moulded Case Circuit Breaker ( 3 no for Block B, spare 1 nos).

1

-

213339.57

... More
SUMP PUMP PANEL INCOMING 1 No. 100 Amp TP Moulded Case Circuit Breaker. (35 KA)1 Set of phase indicating lamps with Single Pole MCB.1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS 150 Amp TPN aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 9 No. 32 Amp TPN MCCB 10 KA Sump Pump Panel described as above

1

-

101929.86

... More
EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)-Supply, Installation, Testing & Commissioning of feeder pillar type totally enclosed free standing type moisture, dust, vermin & weather proof (IP-55) Floor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thick CRCA sheet complete with following equipments, including digital ammeter with inbuilt ammeter selector switch, digital voltmeter with inbuilt voltmeter selector switch, indicating lamps, CT's, internal wiring with suitable size wires / cable, interconnection, painting, MS Stand, RCC foundation etc complete as per specification & drawing. INCOMING 1 No. 63 Amp TP ( 35 KA Ics) Moulded Case Circuit Breaker.1 Set of phase indicating lamps with Protective SP MCB.1 Set 24 Hrs TSQ Timer1 Set 63 Amp, FP Contactor & A/M switch and Push Button.BUS BARS 100 Amp FP aluminium busbar.OUTGOING 4 No. 25 Amp DP MCB. 2 No. 40 Amp DP MCB.2 No. 40 Amp TPN MCB.Spare Blank compartment for future use: 1 NO Spare Blank compartment for future use: 1 NO

2

-

58934.62

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door

48

-

2637.55

... More
Supplying and fixing following way,single pole and neutral , sheet steel MCB DISTRIBUTION BOARD 240 volts on surface/ recess complete with, tinned copper bus bar, neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)12 way double door

6

-

1764.96

... More
Same as above item but 16 way, Double door

24

-

2108.84

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.up to 100 A, 16 KA,TPMCCB ( incomer/outgoings of VTPN DB or hor TP DB)

48

-

3203.23

... More
Supplying and fixing 5 amps to 32 amps, rating, 240/415 volts, 'C' Curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

768

-

171.08

... More
Same as above item but Double pole

6

-

477.99

... More
Supplying and fixing following rating double pole 240volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amp DP MCB

24

-

477.99

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A

24

-

2257.57

... More
Same as above item but 63 A

24

-

2387.38

... More
Supplying and fixing following rating double pole 240volts, Residual current Circuit Breaker ( RCCB ) , having sensitivity of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amp.DP RCCB

6

-

1656.64

... More
Same as above item but 63 amp DP RCCB

24

-

2269.6

... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.( at terrace mumty)

2

-

985.21

... More
WIRING AND ACCESSORIES ( STEEL CONDUIT SYSTEM)-Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe concealed in the wall, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect, as directed including matching colour wash.

1752

-

829

... More
Wiring point for fan / fesh air fan (light duty exhaust fan) with 1.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit concealed in the wall, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm thick phenolic laminated backelite sheet etc complete in all respect, including matching colour wash.

78

-

947

... More
Wiring point for exhaust fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit concealed in the wall, complete with 14 SWG copper earth continuity wire, GP Box , 15 A piano type switch and ceiling rose on 3 mm thick phenolic laminated backelite sheet etc. complete in all respect including mathcing colour wash.

72

-

1194

... More
Wiring point for call bell with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe concealed in the wall, complete with 14 SWG copper earth continuity wire and piano type bell push or 2 pin socket etc., complete in all respect including matching colour wash.

40

-

805

... More
Add for light / fan points with modular type switch in place of piano type switch.

1830

-

44

... More
Add for HPMV/Exhaust fan point with modular type switch in place of piano type switch.

72

-

47

... More
Add for Call bell point with modular type bell push in place of piano type bell push.

40

-

80

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

3000

-

345

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

1532

-

426

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.( For Car Charging in basement/ Split AC outlets)

400

-

549.35

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC copper conductor single core cable in surface/ recessed insulated steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(for power points )

72360

-

227.82

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(for power points )

60680

-

337

... More
Wiring for circuit/ submain wiring alongwith earth wire following sizes of FRLS PVC insulated copper conductor, single with the core cable in surface/ recessed steel conduit as required 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire ( for looped points or secondry points) ( for MCP and telephone jacks of FAS and for flow switches etc)

10545

-

178.82

... More
Same as above item but 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

5440

-

196.87

... More
Same as above item but 2 X 4 sq. mm + 1 X 4 sq. mm earth wire( for UPS DB)

60

-

226.1

... More
Same as above item but 2 x 10 sq. mm + 1 x 6 sq. mm earth wire ( for power DB)

720

-

366.23

... More
Same as above item but 4 x 6 sq. mm + 1 x 6 sq. mm earth wire

420

-

454.78

... More
Same as above item but 4 x 10 sq. mm + 2 x 6 sq. mm earth wire

420

-

576

... More
Supplying and fixing metal box ( modular) of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.100 mm X 100 mm X 60 mm deep( for TV, Tel, data sockets)

3060

-

137.55

... More
same as above item but 200 mm X 250 mm X 60 mm deep ( junction of Tv tel data at zones )( wiring and face plates for TV Telephone and DATA not considered in this estimate)

50

-

288

... More
Supplying and fixing of following sizes of medium class steel conduits along with accessories in surface/ recess including painting in case of surface conduit,or cutting the wall and making good the same in case of recessed conduit as required.20mm

40340

-

125.52

... More
Same as above item but 25mm ( For FAS, Telephone, CCTV DATA PA BMS system or any other purpose etc )

49110

-

141.85

... More
Supplying and fixing modular blanking plate ,on the existing modular plate & switch box excluding modular plate etc. as required.

20

-

27.51

... More
CABLES & CABLE TRAY-Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 6 sq. mm 3 core

3300

-

284

... More
Same as above item but 16 sq. mm 4 core

540

-

343

... More
Same as above item but 35 sq. mm 3-1/2 core

505

-

422

... More
Same as above item but 50 sq. mm 3-1/2 core

1410

-

492

... More
Same as above item but 120 sq. mm 3-1/2 core

765

-

824

... More
Same as above item but 240 sq. mm 3-1/2 core

3080

-

1379

... More
Deduct in item no. 501 (I) 501 (t) and 506 (a) to (f) when cables is passed through G.I./M.S. or Hume pipe in road crossing or along the wall. The cost of the G.I. pipe, hume pipe is to be extra when and where required.

6990

-

170

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

18788.67

-

121.22

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 x 6 sq. mm (19mm)

196

-

170.22

... More
Same as above item but 3½ X 35 sq. mm (32mm)

52

-

257.91

... More
Same as above item but3½ X 50 sq. mm (35mm)

56

-

282.84

... More
Same as above item but 3½ X 120 sq. mm (50mm)

66

-

477.13

... More
Same as above item but 3½ X 240 sq. mm (62mm)

62

-

695.5

... More
Same as above item but 4 X 16 sq. mm (28mm)

48

-

214.92

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm wide x 50 mm depth x 1.6 mm thickness.

200

-

514.96

... More
Same as above item but 150 mm wide x 50 mm depth x 1.6 mm thickness.

2000

-

553.65

... More
Same as above item but 300 mm wide x 50 mm depth x 1.6 mm thickness.

3000

-

752.24

... More
Same as above item but 450 mm wide x 50 mm depth x 2.0 mm thickness.

500

-

1042.81

... More
Same as above item but 600 mm width X 50 mm depth X 2.0 mm thickness

300

-

1415.06

... More
Same as above item but 750 mm width X 62.5 mm depth X 2.0 mm thickness

200

-

1787.31

... More
Same as above item but 900 mm width X 62.5 mm depth X 2.0 mm thickness

100

-

2067.57

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm wide x 50 mm depth x 1.6 mm thickness.

35

-

913.86

... More
Same as above item but 150 mm wide x 50 mm depth x 1.6 mm thickness.

55

-

1004.13

... More
Same as above item but 300 mm wide x 50 mm depth x 1.6 mm thickness.

45

-

1472.66

... More
Same as above item but 450 mm wide x 50 mm depth x 2.0 mm thickness.

25

-

2140.65

... More
Same as above item but 900 mm width X 62.5 mm depth X 2.0 mm thickness

15

-

4488.48

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm wide x 50 mm depth x 1.6 mm thickness.

15

-

1048.83

... More
Same as above item but 150 mm wide x 50 mm depth x 1.6 mm thickness.

25

-

1095.25

... More
Same as above item but 300 mm wide x 50 mm depth x 1.6 mm thickness.

25

-

1716.82

... More
Same as above item but 450 mm wide x 50 mm depth x 2.0 mm thickness.

10

-

2510.32

... More
Same as above item but 900 mm width X 62.5 mm depth X 2.0 mm thickness

5

-

5299.17

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm wide x 50 mm depth x 1.6 mm thickness.

5

-

1528.54

... More
Same as above item but 300 mm wide x 50 mm depth x 1.6 mm thickness.

25

-

2250.69

... More
Same as above item but 450 mm wide x 50 mm depth x 2.0 mm thickness.

35

-

2973.69

... More
Same as above item but 600 mm wide x 50 mm depth x 2.0 mm thickness.

2

-

4119.67

... More
Same as above item but 750 mm wide x 75 mm depth x 2.0 mm thickness.

5

-

5189.13

... More
Same as above item but 900 mm wide x 75 mm depth x 2.0 mm thickness.

3

-

6014.44

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)

200

-

179.68

... More
Same as above item but 120 mm dia (OD-120 mm & ID-103 mm nominal)

100

-

293.16

... More
Same as above item but 160 mm dia (OD-160 mm & ID-135 mm nominal)

40

-

393.74

... More
Same as above item but 200 mm dia (OD-200 mm & ID-175 mm nominal)

20

-

514.1

... More
LIGHT and fan FIXTURES including poles -Supply and fixing of Pendent mounting having 1' X 4' Size 36 to 46 Watt seamlessly intergrateds LED luminier with acrylic sheet diffuser and intergral electronic driver complete in all respects.CAT AA( for conference room etc)

100

-

4290

... More
Supply & Fixing of 20 Watt LED Surface Mounting weather proof Luminaire with PC Housing and opal finish cover confirming to IP 65 Complete in all respect.

338

-

2030

... More
Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.CAT AA

44

-

570

... More
Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.CAT AA

1500

-

3940

... More
Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.CAT AA

752

-

1150

... More
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 140 to 150 Watt. Confirming to IP 66 protection complete in all respect.CAT AA( at terrace and face light)

10

-

9540

... More
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 70 to 90 Watt. Confirming to IP 65 protection complete in all respect.CAT AA ( at terrace and face light)

18

-

5620

... More
Supply & Fixing of 20 Watt LED Surface Mounting weather proof Luminaire with PC Housing and opal finish cover confirming to IP 65 Complete in all respect.( to act as mirror Light)

140

-

2030

... More
Supplying and fixing PVC batten/ angle holder including connections etc. as required.

5

-

77.37

... More
Supply and fixing of door chime on polished MDFEG / Teak ply board including making connections etc. complete in all respect.

40

-

200

... More
Supply Installation testing and commissioning of BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

78

-

2190

... More
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.

40

-

16500

... More
Supply and installation of of GI POLE 3 Mtr high, bottom dia 135 mm , top dia 65 mm , 3 mm thick GI sheet of 65 micron, base plate 16 mm designed for 180 KM/hr wind speed , complete with CC foundation ,cable termination arrangements, earthing stud, 6 A SP MCB , 3*1.5 sqmm FRPVC insulated copper wiring from termination box to fitting etc as required

25

-

5219.78

... More
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect. CAT-AA

40

-

4680

... More
Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect. CAT-AA

25

-

7890

... More
Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. CAT-AA

40

-

3720

... More
Supply, Installing, Testing and Commissioning of 1400 rpm single phase Heavy Duty Exhaust fans Complete with Bird Screen & Gravity Shutter etc as required 300 mm Dia , 1500 cfm

72

-

2525.82

... More
Supply, Installing, Testing and Commissioning of single phase fresh air fans Complete with Bird Screen & Gravity Shutter 200 mm Dia , 250 cfm

4

-

1489

... More
Fire Alarm and PA SYSTEM-Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Ten Loop Panel.

2

-

391072.9

... More
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.

1

-

172066.71

... More
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.

1

-

93339.06

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.

1538.97

-

2446.7

... More
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.

20

-

2267.88

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

94

-

2800.03

... More
Supplying, installation, testing & commissioning of addressable fire control or monitoring module complete as required.

80

-

2570.5

... More
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.

36

-

6706.5

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

86

-

3317.57

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.

40

-

3003.78

... More
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.

6

-

4923.49

... More
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. Note: Fire survival cable for detectors considered note: Conduit and wiring for MCP and Fireman telephone considered in SH: Wiring

30

-

1364.34

... More
PA SYSTEM Supplying, installation, testing & commissioning of 1.5/3 W metal box ceiling/wall speakers complete as required.( 1.5 watt in corridors , 3 watt in basement)

178

-

1530

... More
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.

6

-

125326.69

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sqmm

5340

-

43.84

... More
speaker cable Two pair, 2-core, 1.5 sqmm

1780

-

73

... More
Safety items -Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

9

-

9100

... More
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.

9

-

11980

... More
Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge.

6

-

490

... More
Supply and erection of canopy type M.S.Structure made out of 40mm medium class M.S. pipe (Class-B), 25 x 25 x 3 mm angle iron frame work and 14 SWG GI Sheet. Structure shall be grouted in C.C. 1:2:4 foundation for hanging 4 Nos. 9 litre each fire fighting buckets including providing buckets with two coats of anticorrosive paints etc. complete as required.

2

-

5000

... More
Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.

2

-

305

... More
Supply and fixing of 600mmx 600mm size polished MDFEG / Teak ply cover fabricated from 19mm thick block board with one phase polished, fixed with 75mm hinges on to 65mm x 20mm size PMDFEG / Teak wood chowkhat including aluminium anodized handle of suitable size kunda, chhapka, etc. with all material labour T&P etc. required for proper completion of work.

2

-

940

... More
Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality.

2

-

2550

... More
Earthing and Lightning arrestor- Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

22

-

5343.88

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

10

-

10139.27

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

200

-

1052.27

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

440

-

415.23

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

200

-

867.43

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

440

-

177.1

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

800

-

31.81

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

20

-

1585.28

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

8

-

385.14

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

20

-

79.95

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

250

-

89.41

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

256

-

140.13

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

8

-

87.69

... More
HVAC - MACHINERY-Supplying, Installing, testing & Commissioning of Magnetic Bearing centrifigual water chilling machine having actual capacity of 982800 K.CAL/hour(325 TR) , suitable for operation on refrigerant 134a/ R 1233zde comprising of the following complete as per specification and as reqd.# Max IkW/ TR at design parameters shall be 0.63 , Minimum COP 6.5 at AHRI conditions, and max NPLV shall be 0.351 No.-Mag bearing Centrifugal type compressor open/semi hermatic complete with automatic capacity control, safety switches, speed increasing gears, forced feed lubrication system etc. as per specifications.The unit shall be designed to unload upto 20% of its rated capacity at Constant Condenser Water Entering Water Temperature. The compressor shall have mechanism for stable operation at part loads (either one of movable geometry diffuser/ variable geometry diffuser/ split ring diffuser/ hot gas bypass).CHILLER# Refrigerant : R-134a/ R 1233zde# EWT Chiller - 54 Deg F (12.2 C)# LWT Chiller - 44 Deg F (6.7 Deg C)# Chiller fouling factor -0.0005 (British Units)# Chilled water Circulation Rate: 2952 LPM (nominal) Max Pressure drop 10 mCONDENSOR# Condenser EWT - 90 Deg F( 32.2 Deg C)) / 97.5 Deg F ( 36.4 Deg C)LWT# Condenser fouling factor-0.001 (British Units)# Condensor water Circulation Rate: 4920 LPM (nominal) Max pressure drop 10 m1 No. Suitable capacity squirrel cage induction motor & efficiency class IE-3 suitable for operation on 415+10% volts, 50 HZ, A.C. Supply. (for open type compressor motor H.P. Shall be at least 10% higher than the compressor BHP requirement at full load). 1 No. IP 54 rated factory fitted unit mounted variable frequency drive with active harmonic filters to limit THID to 5% at equipment level and suitable for compressor motor complete with ammeter with CTs, overload protection ,under voltage protection, protection against phase reversal & independent single phase preventors , Copper cables between VFD drive and Chilling machineetc etc complete as requiredNecessary drive arrangement 1 Set- lubrication device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, automatic pressure regulating valve, oil heater, thermal switch etc. as per specifications.1 No - matching ASME U stamped shell and tube double pass water cooled condenser of M.S. shell and integrally fined copper tubes with 2 pass configuration 1 No. -matching ASME U stamped shell and tube double pass flooded type chiller for centrifugal type units of M.S.shell and copper tubes with 2 pass configuration 1 Lot- Refrigerant piping fittings,valves and accessories to inter connect compressor, condenser, chillers and expansion valve.1 Set - Microprocessor based control panel complete with accessories as per specifications.Lot - Refrigerant line accessories comprising of safety valves, angle valves, liquid line indications, liquid level control etc.lot- water flow switches at inlet and outlet of condenser and chiller, water drain and air purge valves wherever required.lot- flexible/victaulic make or equivalent coupling at the inlet and outlet piping connections of evaporator and condenser of chillers.Lot- Suction line and chiller insulation with minimum 19 mm thick polyvinyl nitrile rubber insulation duly insulated at manufacturer works finished with 0.633mm thick G.S.S. Cladding as required.Lot - Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with antivibration pads/springs.Lot-Initial/first charge of refrigerant gas and compressor oil pre charged at factory.Magnetising arrangement/VSD components including Capacitors and/or UPS shall have life of minimum 15 years ( 12 hours operation)Lot-RCC/Cement concrete foundation i/c necessary vibration isolation mountings for the chilling unit. Supplying, erection, testing and commissioning of condenser water pump set, capable of delivering 4920 LPM of water against 82 Ft.(25 mtr) head each comprising of the following and complete as per specifications and as required : 1 No. Horizontal End suction split casing type pump. 1 NO- Suitable HP, TEFC squirrel cage induction motor with class 'F' insulations & efficiency class IE-3, 1450 rpm synchronous speed , operating on 415 +10% volts ,3 phase , 50 Hz A.C.supply. 2 Nos- 150 mm dia dial type pressure guages.1 No electronic Differential Pressure Transmitter Lot- Mounting frame work with anti vibration pads.Min. pump efficiency at duty conditions shall be 75%pumps to be provided with separate IP 54 rated variable frequency drives ( to be mounted in existing Electrical Panel) with integrated input disconnect switch. Control panel should also consist of cooling fan. Lot- RCC/Cement concrete foundation for the pump unit.Note :The pump shall be selected suitably so as the flow is max 10% above the mentioned flow rate control with balancing valve fully open. Beyond that the impeller shall be modified suitably and then the balancing valves shall be used to reduce flow rate.

3

-

280000

... More
Supplying , erection, testing and commissioning of chilled water Primary pump set, capable of delivering 2952 LPM of water against a head of 33FT.(10mtr.) Each pump shall comprise of following as required as per specifications. 1 No. Horizontal End suction split casing type pump with Bronze impeller,SS shaft, CI body and mechanical seal. 1 NO- Suitable HP, TEFC squirrel cage induction motor with class 'F' insulations & efficiency class IE-3, 1450 rpm synchronous speed , operating on 415 +10% volts ,3 phase , 50 Hz A.C.supply. Lot-Expanded polystrene (T.F.Quality) insulations of not less than 50mm thick duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular section as per specifications. 2 Nos- 150 mm dia dial type pressure guages. 1 No electronic Differential Pressure Transmitter Lot- Mounting frame work with anti vibration pads. pumps to be provided with separate IP 54 rated variable frequency drives ( to be mounted in existing Electrical Panel) with integrated input disconnect switch. Control panel should also consist of cooling fan. Lot- RCC/Cement concrete foundation for the pump unit. Note :The pump shall be selected suitably so as the flow is max 10% above the mentioned flow rate control with balancing valve fully open. Beyond that the impeller shall be modified suitably and then the balancing valves shall be used to reduce flow rate. Min. pump efficiency at duty conditions shall be 75%

3

-

175000

... More
Supplying , erection, testing and commissioning of chilled water Secondary pump set, for Block A with VFD capable of delivering 4428 LPM of water against a head of 40 mtr .Each pump shall comprise of following as required as per specifications. (1W+1S)Two (2) No. Horizontal End suction split casing type pump with Bronze impeller,SS shaft, CI body and mechanical seal. Two (2) NO- Suitable HP, TEFC squirrel cage induction motor with class 'F' insulations & efficiency class IE-3, 1450 rpm synchronous speed , operating on 415 +10% volts ,3 phase , 50 Hz A.C.supply. All pumps to be provided with separate IP 54 rated variable frequency drives ( to be mounted in existing Electrical Panel) with integrated input disconnect switch. Control panel should also consist of cooling fan. Microprocessor based control panel shall have suitable hardware & software so that it can be integrated directly to Chiller Plant Manager with standard communication open protocol using backnet / Modbus as well as open IP. Variable secondary Panel should have a dedicated programmable logic controller with individual drive for each pump and with required no. of sensors and the entire unit has to be procured from the Pump manufacturer or their licenced partner/authorised oem to ensure the smooth operation of the system. The Programmable logic controller shall be able to control minimum 1 Pump and maximum of 3 Pumps, Automatic cascade control of pumps, automatic sequence change, Friction loss compensation, pump status shall be there. Display shall be graphical type with minimum 320 pixels X 240 Pixels VGA display with backlight.Drive should have rated input frequency 50 Hz and output frequency range of 0.5 to 132 Hz. An IP41/IP55 Nema Standard powder coated steel enclosure for Basement/Roof top, with sufficient capacity cooling fan and shall house all the electrical control components. Lot-Expanded polystrene (T.F.Quality) insulations of not less than 50mm thick duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular section as per specifications. 2 Nos- 150 mm dia dial type pressure guages. 2 sets of Electronic Differential Pressure Transmitters Lot- Mounting frame work with anti vibration pads. Lot- RCC/Cement concrete foundation for the pump unit. Note: Min. pump efficiency at duty conditions shall be 75%, Pump shall be suitable for both chilled water and hot water

1

-

750000

... More
Supplying , erection, testing and commissioning of chilled water Secondary pump set, for Block B with VFD capable of delivering 1476 LPM of water against a head of 30 mtr Each pump shall comprise of following as required as per specifications. (1W+1S) Two (2) No. Horizontal End suction split casing type pump with Bronze impeller,SS shaft, CI body and mechanical seal. Two (2) NO- Suitable HP, TEFC squirrel cage induction motor with class 'F' insulations & efficiency class IE-3, 1450 rpm synchronous speed , operating on 415 +10% volts ,3 phase , 50 Hz A.C.supply. All pumps to be provided with separate IP 54 rated variable frequency drives ( to be mounted in existing Electrical Panel) with integrated input disconnect switch. Control panel should also consist of cooling fan. Microprocessor based control panel shall have suitable hardware & software so that it can be integrated directly to Chiller Plant Manager with standard communication open protocol using backnet / Modbus as well as open IP. Variable secondary Panel should have a dedicated programmable logic controller with individual drive for each pump and with required no. of sensors and the entire unit has to be procured from the Pump manufacturer or their licenced partner/authorised oem to ensure the smooth operation of the system. The Programmable logic controller shall be able to control minimum 1 Pump and maximum of 3 Pumps, Automatic cascade control of pumps, automatic sequence change, Friction loss compensation, pump status shall be there. Display shall be graphical type with minimum 320 pixels X 240 Pixels VGA display with backlight.Drive should have rated input frequency 50 Hz and output frequency range of 0.5 to 132 Hz. An IP41/IP55 Nema Standard powder coated steel enclosure for Basement/Roof top, with sufficient capacity cooling fan and shall house all the electrical control components. Lot-Expanded polystrene (T.F.Quality) insulations of not less than 50mm thick duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular section as per specifications. 2 Nos- 150 mm dia dial type pressure guages. 2 sets of Electronic Differential Pressure Transmitters Lot- Mounting frame work with anti vibration pads. Lot- RCC/Cement concrete foundation for the pump unit. Note: Min. pump efficiency at duty conditions shall be 75%, Pump shall be suitable for both chilled water and hot water

1

-

750000

... More
Supplying , erection, testing and commissioning of Hot water pump set, capable of delivering 400USGPM(1512 LPM) of water against a head of 98 Ft.( 30 mtr) .Each pump shall comprise of following as required as per specifications. One (1) No. Horizontal End suction split casing type pump with Bronze impeller,SS shaft, CI body and mechanical seal. One (1) NO- Suitable HP, TEFC squirrel cage induction motor with class 'F' insulations & efficiency class IE-3, 1450 rpm synchronous speed , operating on 415 +10% volts ,3 phase , 50 Hz A.C.supply. All pumps to be provided with separate IP 54 rated variable frequency drives ( to be mounted in existing Electrical Panel) with integrated input disconnect switch. Control panel should also consist of cooling fan. Lot-Expanded polystrene (T.F.Quality) insulations of not less than 50mm thick duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular section as per specifications. 2 Nos- 150 mm dia dial type pressure guages. 1 No electronic Differential Pressure Transmitter Lot- Mounting frame work with anti vibration pads. Lot- RCC/Cement concrete foundation for the pump unit. Note: Min. pump efficiency at duty conditions shall be 75%, Pump shall be suitable for both chilled water and hot water

2

-

200000

... More
Supplying, installing, testing and commissioning of CTI CERTIFIED FRP Cooling tower of 400 TR ( 1209600 K.CAL/hr) heat rejection capicity with FRP Water basin , PVC Filling with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor of Efficiency class IE-3 , suction screen, make-up quick fill arrangement, overflow and drain connections with necessary valves and suitable inspection ladder made of Stainless Steel ,40 mm dia pipe, access arrangement for cooling tower interior, cement concrete foundation, steel/ mesonary supporting structure, anti-vibration mountings etc. complete as per specifications and as reqd. The cooling tower fan motor shall be EEF-1 Class rating .( Design parameters /specification/duty of cooling tower to match Condensor as above and as per CPWD Specifications)

3

-

620860.43

... More
HOT WATER GENERATOR-Supply, installation, testing and commissioning of package type Electric Hot Water Generator constructed out of MS sheet (as per specifications) having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with minimum75 mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminum cladding sheet. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in Six teps complete with manual/auto rotary switches.200 kW automatic Hot Water Generator as described abovea. Water ‘IN’ temperature : 110 deg F.b. Water ‘OUT’ temperature : 120 deg F c. Heater Bank to be provided with minimum 8 steps with auto operation.

2

-

221232.87

... More
Pressurised Expansion Tank with Air Separator -PN 16 rated Supply, Installation, Testing and commissioning of insulated closed chilled water expansion tank along with necessary accessories with Pressure Transmitter and interconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. synthetic rubber erc as required The tank shall have 50 MM system connection and 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank. The tank shall be fitted with lifting rings and a floor mounting pedestal/skirt for vertical installation. The tank must be constructed in accordance with IS- 2825-1969 suitable for 125 PSI working pressure. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system. The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panel IP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. Minimum tank capacity 2000 Liters. Chilled water closed vessel pressurized expansion tank as described above shall be duly insulated with minimum 38 mm thick closed cell nitrile rubber insulating material and cladded with aluminium Sheet of 20G.Microbubble /Centrifugal type PN -16 rated air separator with pot type strainer for flanged connection 150mm pipe line, automatic air purging arrangement etc. The design parameters for the air separator of efficiency 96-98 %. complete with super vent as required. and duly insulated with 38 mm thick closed cell nitrile rubber/snthetic rubber insulating material and cladded with aluminium Sheet of 20G. Proposed system shall comply to DBR & NIIT technical specification. Pressurisation unit complete with pumps, valves ,control panel etc as required a) For Chilled Water Circuit1 , Minimum 2000 Ltr expansion Tank Capacity with 300 mm dia Air Separator safe valve, Dirt separator with supervent & matching flanges , bolts, nuts & gasket without insulation valves & fitting.300mm dia Pressurisation unit complete with double pump IP55 comtrol panel with pressure transitter , flow meter , interconnecting piping & wiring

1

-

508449.15

... More
same as above item but a) For Chilled Water Circuit21 , Minimum 1500 Ltr expansion Tank Capacity with 200 mm dia Air Separator ( safe valve, Dirt separator with supervent & matching flanges , bolts, nuts & gasket without insulation valves & fitting.200mm dia Pressurisation unit complete with double pump IP55 comtrol panel with pressure transitter , flow meter , interconnecting piping & wiring )

1

-

410875.55

... More
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. Max KW CFM RD SP(mm) Filtration Std. 15300 CMH

12

-

222214.58

... More
Same as above item but 18700 CMH

4

-

259877.92

... More
Same as above item but 39100 CMH

2

-

410654.23

... More
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.150mm dia.

2

-

130143.57

... More
Same as above item but 80mm dia.

4

-

55150.45

... More
Same as above item but 65mm dia.

12

-

43333.05

... More
Same as above item but 50mm dia.

1

-

28068.26

... More
Supply, Installatlion, Testing & Commissioning of Chilled Water cylindrical Vertical Cooler unit for proving Chilled water in the Building , made from 2mm thick SS 3041 for following capacity , with SS 3041 seamless cooling coil of 16 Gauge thick pipe, with safeties and man hole , duly insulated with high density thermocol and cladded with 24 gauge SS 304 sheet with all controller such as 3-way temp. control valve with ball valve, thermostat (digital), vent valve & Float valve , mounting arrangement/MS frame complete as required , suitable for outdoor as per specifications attached.500 LPH, Cold water storage 700 ltr.

4

-

222214.58

... More
Supplying, installation, testing and commissioning of fan coil units having following capacities, ceiling/ wall mounted complete with copper tubes, chilled water cooling coils having aluminium fins and auxiliaries including ball valve set, insulation of drain pan, drain connections, blower, TEFC Slow speed (3 speeds) squirrel cage induction motor suitable for operation 230 volts, single phase, 50 Hz, A.C. SUPPLY.LOCATION. CFM RD Basement 600 3

2

-

25000

... More
Supply, installing, testing and commissioning of BEE: 5 - star efficiency class rated AIR COOLED SPLIT AIR CONDITIONING UNITS with R-32 / 410A refrigerant as described in specifications. The unit shall be complete with cabinet type fan coil unit and external condensing unit, complete in all respects, inclusive of 15Rmt. copper refrigerant piping, 10mt. GI condensate drain piping, valves and insulation. Quoted price shall include cost of wireless remote controller, cooling thermostat, wiring, control cooling and earthing. Unit shall be provided with auto timer setting. The unit capacities shall be as follows :1.5 TR Air Cooled Split Unit Ceiling Mounted Duct Type (Low Static)

2

-

43000

... More
same as above item but 2.0 TR Air Cooled Split Unit Ceiling Mounted Duct Type (Low Static)

2

-

50000

... More
HVAC PLUMBING-Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of Note: all fittings /joints at site work shall be done as per manufacturer's specifications/recommendations 400 mm dia and above.350 mm dia.(75 mm thick insulation)

30

-

7405.43

... More
same as above item but 300 mm dia.(75 mm thick insulation)

25

-

6426.24

... More
same as above item but 250mm dia.(75 mm thick insulation)

200

-

5371.39

... More
same as above item but 200mm dia (75 mm thick insulation)

160

-

4557.26

... More
same as above item but 150mm dia. (75 mm thick insulation)

40

-

2967.68

... More
same as above item but 80mm dia. (50mm thick insulation)

40

-

1727.99

... More
same as above item but 65mm dia.(50mm thick insulation)

140

-

1476.1

... More
same as above item but 25 mm dia (50mm thick insulation)

50

-

878.61

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauge in the chilled water plumbing duly insulated to the same specifications factorysite as the connected piping and adequately supported as per specifications.SITC of C.I. Butterfly valve (PN-16) with builtin measuring facility with CI body, Flange construction with EPDM coated disc with long pitch with protected out pipe insulation and PN 16 pressure rating for chilled/hot water circulation as specified.8 inch (200 mm) Ø

16

-

11036.8

... More
same as above item but 6 inch (150 mm) Ø

4

-

5636.18

... More
same as above item but 4 inch (100 mm) Ø

4

-

4443.78

... More
same as above item but 3 inch (80 mm) Ø

8

-

3173.14

... More
same as above item but 2.5 inch (65 mm)Ø

24

-

2953.92

... More
same as above item but 2 inch (50 mm) Ø

2

-

2722.66

... More
same as above item but 1.75 inch(40 mm) Ø

2

-

2514.61

... More
Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required.250mm dia.

2

-

58216.99

... More
same as above item but 200mm dia.

8

-

44528.03

... More
same as above item but 150mm dia.

4

-

34520.29

... More
SITC of Swing check valve,C.I double flap (PN-16) as per Specification.8 inch (200 mm) Ø

3

-

11609.35

... More
same as above item but 6 inch (150 mm) Ø

5

-

7132.05

... More
SITC of CI Flanged Balancing valve (PN-16) with builtin measuring facility as per Specification.8 inch (200 mm) Ø

2

-

45250.17

... More
same as above item but 6 inch (150 mm) Ø

5

-

22867.95

... More
same as above item but 4 inch (100 mm) Ø

4

-

13087.17

... More
same as above item but 3 inch (80 mm) Ø

4

-

8906.46

... More
SITC of C.I. Y-type strainer (PN-16) as per Specification.8 inch (200 mm) Ø

2

-

24821.18

... More
same as above item but 6 inch (150 mm) Ø

2

-

12687.41

... More
same as above item but 4 inch (100 mm) Ø

4

-

8443.09

... More
same as above item but 3 inch (80 mm) Ø

2

-

6123.62

... More
same as above item but 2.5 inch (65 mm)Ø

12

-

5336.14

... More
same as above item but 2 inch (50 mm) Ø

18

-

4326.86

... More
same as above item but 1.75 inch(40 mm) Ø

3

-

3064.82

... More
SITC of Flexible connections (PN-16) in piping as per Specification.10 inch (250 mm) Ø

26

-

12424.18

... More
same as above item but 8 inch (200 mm) Ø

4

-

7375.24

... More
same as above item but 6 inch (150 mm) Ø

18

-

5474.8

... More
SITC of water pressure guage (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) / (0-100) as required.

7

-

940.51

... More
SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5C least count, range 0-50 C. Brass oil filled thermowell of 1/2" size

7

-

822.73

... More
CONDENSOR PIPING AND VALVES WITHOUT INSULATION- Supplying, fixing, testing and commissioning of condenser water pipes of following sizes and materials along with necessary clamps, vibration isolators, and fitting such as bends, tees etc. but excluding strainer and gauges etc adequately supported on rigid supports etc as per specification and as required. 300mm dia.

250

-

4530.61

... More
same as above item but 250 mm dia

50

-

3783.53

... More
same as above item but 100mm dia.

50

-

1533.7

... More
SITC of Butterfly Valve (Complete with fittings, Nuts, Bolts & Gaskets (PN-16Rating).200mm dia.

12

-

9913.17

... More
same as above item but 150mm dia.

5

-

4678.47

... More
same as above item but 50mm dia.

4

-

2187.07

... More
same as above item but 40mm dia.

3

-

2050.38

... More
SITC of Flexible connections (PN-16) as per Specification.8 inch (200 mm) Ø

15

-

7375.24

... More
SITC of Pot strainer (PN-16) as per Specification. 10 inch (200 mm) Ø

3

-

30000

... More
SITC of water pressure guage (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) / (0-100) as required.

7

-

940.51

... More
SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5C least count, range 0-50 C. Brass oil filled thermowell of 1/2" size

7

-

822.73

... More
HVAC : DUCTING AND GRILLS-Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet

1500

-

845.08

... More
same as above item but Thickness 0.80 mm sheet

4000

-

992.09

... More
same as above item but Thickness 1.00 mm sheet

1000

-

1094.39

... More
same as above item but Thickness 1.25 mm sheet

200

-

1441.71

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet

50

-

809.83

... More
same as above item but Thickness 0.80 mm sheet

50

-

949.11

... More
same as above item but Thickness 1.00 mm sheet

200

-

1253.44

... More
same as above item but Thickness 1.25 mm sheet

100

-

1388.41

... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.

100

-

5588.03

... More
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room Damper

200

-

6835.45

... More
same as above item but Actuator

60

-

6843.19

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

200

-

7290.23

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

200

-

4734.35

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

200

-

9768.74

... More
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

200

-

6498.45

... More
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications.200 mm dia.

10

-

462.52

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper

100

-

8496.39

... More
samen as above item but Actuator

54

-

7919.53

... More
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.

5000

-

556.22

... More
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.

1440

-

979.2

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm

5000

-

599.21

... More
same as above item but 25mm

200

-

770.29

... More
HVAC ELECTRICAL PANELS- Supplying, installation, testing & commissioning of cubical type main MV panel board suitable for 3 phase, 415 V, 50 Hz and of 35 MVA rupturing caoacity at 415 volts, fabricated from minimum 2mm thick CRCA Sheet powder coated through seven tank process facility for pickling and degreasing complete with following mountings, inter connections etc as required (Main Electric Panel),AC Panel -(Location : Plant Room),Incomer (1 Nos.)-Each shall have following:1000A, 4P EDO type ACB (50 KA) with Microprocessor based release unit for short circuit, over current and earth fault protection with adjustable setting and each shall have following accessories:Multifunction Meter with RS 485 port to indicate V, I, p.f., KW, KWH, with CT's etc as required,LED type Phase indicating lamps and shall be protected by 2Amps MCBs,Bus Bar:1250 Amps TPN Aluminium busbars, colour coded with heat shrinkable insulation sleeves (after derating).Outgoing:All Outgoing MCCB shall be Ics=Icu ,thermal release and Shall have 25 KA breaking capacity .Three (3) Nos. 400 A TPN MCCB (for Chillers ).Two (2) Nos. 400 A TPN MCCB (for Hot water generators ),Three (3) Nos. 63A TPN MCCB (for Secondary chilled Water Pumps Block B),Two (2) Nos. 63 TPN MCCB (for Secondary chilled Water Pumps Block B).Necessary space/compartments for mounting VFD's and logic Controller i/c cut out for readings of VFD etc as required etc shall be provided in this panel itself.Three ( 3) sets each consisting of 100A 35 KA TPN MCCB , suitable VFD for the duty intended , potential free contacts for remote operation in each feeder and Auto Manual Selector Switch as required (for Condenser Water Pump).Three (3) sets each consisting of 100A TPN MCCB , suitable VFD for the duty intended , potential free contacts for remote operation in each feeder and Auto Manual Selector Switch as required (for Primary chilled Water Pump).Three (3) sets each consisting of . 100A TPN MCCB , suitable VFD for the duty intended , potential free contacts for remote operation in each feeder and Auto Manual Selector Switch as required (for Cooling tower fans).Two (2) sets each consisting of 63 A TPN MCCB ,Star/Delta starter with contactor O/L relay with single phase preventor suitable for 5 KW motor with ON/OFF / Trip indication lamps and push buttons, Digital ammeter with CTs and selector switch, potential free contacts for remote operation in each feeder and Auto Manual Selector Switch as required (for plant room ventilation).Two (2) sets each consisting of . 63 A TPN MCCB ,suitable VFD for intended duty , potential free contacts for remote operation in each feeder and Auto Manual Selector Switch as required (for Hot Water Pumps).1 No. 400A TPN MCCB.(Spare Feeder),1 No. 200A TPN MCCB.(Spare Feeder),2 No. 100A TPN MCCB.(Spare Feeder),2 No. 63A TPN MCCB.(Spare Feeder).PANEL AS ABOVE including design and as per actual requirement

1

-

949190.3

... More
AHU STARTER PANEL- AHU STARTER PANEL-Supplying, installation, testing and commissioning of MV panel board of cubical type, compartmentalised design fabricated from 2.0mm thick CRCA Sheet having necessary cable alleys, powder coated through seven- tank process facility for picking and degreasing, including connections and interconnections as per specifications (The integration of the VFD with fans will be included in this item) complete with following accessories as required. AHU PANEL TYPE A1, having VFD of 5.5 KW,Incomer: 100 A, TPN MCCB (25 KA),Metering:Multi function meter with RS 485 communication protocol and indicating V, I, Kw, KWH , with necesary CT's etc as required,Phase indicating lamps and shall be protected by 2Amps MCBs.Bus Bars:125Amps TPN Aluminium busbars, colour coded with heat shrinkable insulation sleeves (after derating).Outgoing:One (1) Nos. 40A 15 KA TP MCCB.One (1) No Variable Frequency Drive ( IP 54 rated Air cooled, with a provision of 24 V , 100 mA DC out, 2 Analog and 6 Digital INPUTs, 1 Analog and 1 Digital Output, 2 Relay outputs, 2 Modbus RTU etc, Adjustable at least from 20% to 100% variation, active harmonic filters to limit THID to 5% at equipment level ) suitable for 5.5 KW 3 phase AC Motor of AHU Blower i/c drive arrangement, complete with ammeter with CTs, overload protection ,under voltage protection, protection against phase reversal & independent single phase preventors etc complete as required. Two (2) Nos. 20A TP MCB (Spare).Six (2) Nos. 20A DP MCB (Spare).

12

-

49791.19

... More
same as abobe but AHU PANEL TYPE A2, having VFD of 11 KW .Incomer: 100 A, TPN MCCB (25 KA),Metering:Multi function meter with RS 485 communication protocol and indicating V, I, Kw, KWH , with necesary CT's etc as required,Phase indicating lamps and shall be protected by 2Amps MCBs.Bus Bars:125Amps TPN Aluminium busbars, colour coded with heat shrinkable insulation sleeves (after derating).Outgoing:One (1) Nos. 40A 15 KA TP MCCB ,One (1) No 11 KW Variable Frequency Drive ( IP 54 rated Air cooled, with a provision of 24 V , 100 mA DC out, 2 Analog and 6 Digital INPUTs, 1 Analog and 1 Digital Output, 2 Relay outputs, 2 Modbus RTU etc, Adjustable at least from 20% to 100% variation, active harmonic filters to limit THID to 5% at equipment level ) suitable for 11 KW 3 phase AC Motor of AHU Blower i/c drive arrangement, complete with ammeter with CTs, overload protection ,under voltage protection, protection against phase reversal & independent single phase preventors etc complete as required,Two (2) Nos. 20A TP MCB (Spare),Six (2) Nos. 20A DP MCB (Spare).

6

-

56760.19

... More
HVAC ELECTRICAL PANELS-ventilation-Supplying , installation,balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with meoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. As per approved drawing specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet

300

-

845.08

... More
same as above item but Thickness 0.80 mm sheet

300

-

992.09

... More
same as above item but Thickness 1.00 mm sheet

200

-

1094.39

... More
same as above item but Thickness 1.25 mm sheet

100

-

1441.71

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

30

-

7290.23

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

50

-

4734.35

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

10

-

9768.74

... More
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

10

-

6498.45

... More
Supplying and fixing of acoutic linning of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3 with 25*25 mm GI section of 1.25 mm thick at 600 mm c-to-c covered with hreinforced plastic tissue paper and 0.5 mm perforated Aluminium sheet fixed to inside surface of duct with cadmium plated nuts,bolt,stick pins , cold setting adhesive (CPRX compound ) etc complete as required and as per specification .

50

-

556.22

... More
Vane Axial Flow Fans: Normal duty.Supply, installation, testing and commissioning of Vane Axial flow fan , suitable for VFD operation. The fans should be AMCA certified for air performance & sound ratings and the fan should be selected for maximum efficiency.NOTES : Fans shall be UL listed/EN certified , suitable for 30mm static pressure and shall be supplied with Mounting Rails suitable for Ceiling hanging , flexible sleeve connections at one/both ends . Motor Efficiency Class IE2.Noise level to be measured at reverberant room conditions , at 1.5 Mtr distance from fan and shall be not more than as follows -up to 18000 cfm- 79 DB (A).18001 to 25000 cfm- 81 DB (A).Dia of outer casing of fan including its flanges/frame etc not to exceed : 1100 mm.Plant Room Ventilation Fresh air-16000 CFM

2

-

59210.75

... More
same as above item but PRESSURISATION FANS-14000 CFM for Staircase pressurisation (25mm Static Pressure.)

3

-

51108.22

... More
same as above item but 18000 CFM for Staircase and lift lobby pressurisation (25mm Static Pressure.)

5

-

59210.75

... More
same as above item but 8000 CFM for Lift well pressurisation (20mm Static Pressure)

7

-

38529.48

... More
Fire Rated Vane Axial Flow Fans.Supply, installation, testing and commissioning of Vane Axial flow fan suitable for VFD operation . The fans should be AMCA certified for air performance & sound ratings and the fan should be selected for maximum efficiency. The fan should be fire rated for a minimum of 250 Deg C for a minimum of 2 Hrs. NOTES : Fans shall be UL listed/EN certified , suitable for 30mm static pressure and shall be supplied with Mounting Rails suitable for Ceiling hanging , flexible sleeve connections at one/both ends . Motor Efficiency Class IE2.Noise level to be measured at reverberant room conditions , at 1.5 Mtr distance from fan and shall be not more than as follows.up to 18000 cfm- 79 DB (A).18001 to 25000 cfm- 81 DB (A).Dia of outer casing of fan including its flanges/frame etc not to exceed : 1100 mm.Plant Room Ventilation Fresh air-16000 CFM

2

-

59210.75

... More
same as above item but for other areas in basement exhaust-7500 cfm

2

-

43345.67

... More
same as above item but 11000 CFM

2

-

46688.66

... More
same as above item but 15000 CFM

2

-

59210.75

... More
same as above item but for other areas inFOR OTHER AREAS IN BASEMENT EXHAUST 7500 CFM

2

-

43345.67

... More
same as above item but 11000 CFM

2

-

46688.66

... More
same as above item but 15000 CFM

2

-

59210.75

... More
Supply, installation, testing and commissioning of CO Sensors complete as required as per site condition and providing control wiring, necessary controller and integration with VFD of Ventilation Panel for auto adjustment of no and speed of fan based upon CO level .

8

-

3901.31



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.