GAIL India Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

GAIL India Limited - GAIL Tender

Works
Energy, Oil and Gas
Solar Installation and Products
Electrical and Electronics
Eprocure
Opening Date2 Aug 2024
Closing Date26 Aug 2024
Tender Amount₹ 1,77,37,047 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Solar PV Modules- Mono crystalline (Min 500Wp) BIS certified for SPV array Min 3KWp (2X1500Wp) along with junction boxes as per specification and scope of work.

6

-

-

... More
Anodized AL/ Hot dipped Galvanized M-Steel structure as per specification and scope of work for SPV array Min 3KWp (2X1500 Wp) along with all required hardware, material & anchoring material etc.

6

-

-

... More
MPPT Solar Charger Min (Dual-2x60A ) @ 60V as per specification and scope of work with DC_DC Converter (48V+/-1% Regulated DC Output 1000W convertor with input variation of +/- 20%) and DCDB [48V] as per specification and scope of work.

6

-

-

... More
Ni-Cd Battery bank (Pocket Plate type) in (2x50%) arrangement, 26 KVAH @ 60V, (where KVAH = battery cell AH x 1.2 V x No. of cells) as per specification and scope of work. .

6

-

-

... More
Balance of System materials & equipments- 1) Interconnecting cables among arrays (solar grade), charge controller, battery bank, Grid charger, DCDBs, junction boxes etc including supply of all erection material & accessories like cable glands, cable tray, tinned-cu lugs etc as required. 2) Earthing and lightning protection system as required to complete the system. 3) Required material for Erection work, Civil & Other miscellaneous work

6

-

-

... More
DC-AC INVERTER (REFER SCOPE OF WORK FOR SUPPLY LOCATION)- Pure sine wave output inverter (dual redudant) for fire system having DC Input range (75-135V DC) and AC Output (230V AC +/-1%, 50 Hz +/- 1%), 500VA with over load, short circuit and over temp protection and with galvanic isolation as per specification with 04 nos of MCB output (6A) including supply of all interconnecting cables.

15

-

-

... More
GRID CHARGER FOR BATTERY BANK FOR FOR 200 WATT SYSTEM- Design, Detailed Engineering, Manufacturing, Inspection/FAT (Factory acceptance test), Supply, Transportation, loading/unloading, insurance, Storage at site of DSP based FCBC CHARGER (1x100%, single redudant, auto & manual operation of float & boost function) to charge the battery bank from grid supply, including commissioning spare excluding O&M spares as required, as per specifications, data sheet and instruction of Engineer-in-charge. The charger shall operate on the single phase with the input voltage supply of 415Vac, 3 Phase with Neutral, 50 Hz 330 ~ 460 Vac, 47 ~ 53 Hz. FCBC shall consist of three single phase chargers connected in parallel fed by R-Y-B phase respectively. The rating of FCBC shall be min 60V & 60 Amp, shall be calculated such that it can charge fully discharged complete battery bank at C10 rating.

6

-

-

... More
Total price for Part 1 (Supply) including all costs, freight, insurance till commissioning, GST etc.

-

-

-

... More
PART 2 - Site work -Installation, testing & commissioning- Loading/unloading at site, transportation, Installation, testing, commissioning and performance test at site (ODISHA/ WB/ANDHRA PRADESH)-

-

-

-

... More
SYSTEM-I- 200 WATT HYBRID SPV SYSTEM WITH 48 Hrs BACKUP FOR SV STATION WITH PCP STATIONS IN BIHAR /ASSAM STATE (REFER SCOPE OF WORK FOR LOCATION OF THE SYSTEM)-48 Hrs back up. Loading/unloading at site, Installation, testing, commissioning and performance test at site of complete Solar PV based Power source with two days autonomy for 200W DC load for twenty four hours operation per day operation (48 Hr back up) as per tender specification, data sheet, scope of work and block diagram enclosed including commissioning spares as required at each SV station. The system shall include following- (i) Ni-Cd (1.2V/Cell) Pocket Plate Battery Bank (60V DC) (ii) Solar PV array with junction boxes, Anodized AL/ Hot dipped Galvanized M-Steel structure (ii) DC-DC Converter( 48V +/-1% Regulated DC Output) (iii) Interconnecting cables among battery bank, Grid charger, junction boxes etc including laying & termination of all accessories like cable glands, cable tray, tinned-cu lugs etc as required. iv) Earthing and lightning protection system as required to complete the system. (vii) Erection materials & Other miscellaneous work Rating of SPV array, charge controller and battery bank shall be selected to meet the load requirement as specified above. However, each subsystem rating shall not be less than the value given below-

-

-

-

... More
Solar PV Modules- Mono crystalline (Min 500Wp) BIS certified for SPV array Min 3KWp (2X1500Wp) along with junction boxes as per specification and scope of work.

6

-

-

... More
Anodized AL/ Hot dipped Galvanized M-Steel structure as per specification and scope of work for SPV array Min 3KWp (2X1500 Wp) along with all required hardware, material & anchoring material etc.

6

-

-

... More
MPPT Solar Charger Min (Dual-2x60A ) @ 60V as per specification and scope of work with DC_DC Converter (48V+/-1% Regulated DC Output 1000W convertor with input variation of +/- 20%) and DCDB [48V] as per specification and scope of work.

6

-

-

... More
Ni-Cd Battery bank (Pocket Plate type) in (2x50%) arrangement, 26 KVAH @ 60V, (where KVAH = battery cell AH x 1.2 V x No. of cells) as per specification and scope of work. .

6

-

-

... More
Balance of System materials & equipments- 1) Interconnecting cables among arrays (solar grade), charge controller, battery bank, Grid charger, DCDBs, junction boxes etc including laying & termination of all erection material & accessories like cable glands, cable tray, tinned-cu lugs etc as required. 2) Earthing and lightning protection system as required to complete the system. 3) Required material for Erection work, Civil & Other miscellaneous work

6

-

-

... More
DC-AC INVERTER- Pure sine wave output inverter (dual redudant) for fire system having DC Input range (75-135V DC) and AC Output (230V AC +/-1%, 50 Hz +/- 1%), 500VA with over load, short circuit and over temp protection and with galvanic isolation as per specification with 04 nos of MCB output (6A) including layinig & termination of all interconnecting cables.

15

-

-

... More
GRID CHARGER FOR BATTERY BANK FOR FOR 200 WATT SYSTEM- Loading/unloading at site, Installation, testing, commissioning and performance test at site of DSP based FCBC CHARGER (1x100%, single redudant, auto & manual operation of float & boost function) to charge the battery bank from grid supply, including commissioning spare excluding O&M spares as required, as per specifications, data sheet and instruction of Engineer-in-charge. The charger shall operate on the single phase with the input voltage supply of 415Vac, 3 Phase with Neutral, 50 Hz 330 ~ 460 Vac, 47 ~ 53 Hz. FCBC shall consist of three single phase chargers connected in parallel fed by R-Y-B phase respectively. The rating of FCBC shall be min 60V & 60 Amp, shall be calculated such that it can charge fully discharged complete battery bank at C10 rating.

6

-

-

... More
Total price including all costs including GST for SiteWorks

-

-

-

... More
NOTE: 1. The offer shall be evaluated on package wise basis ( Supply + Site Works ). 2.State wise quantity distribution of each Part is indicated in MR. 3. The above shall be read in conjunction with notes of MR .

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.