GAIL India Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

GAIL India Limited - GAIL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Aug 2024
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, Testing & Commissioning of AIR TERMINATION ROD D 8mm L 2m , MATERIAL OF ROD: ALMgSi, CROSS SECTION: 50 SQ. MM, APPLICABLE STANDARD: EN 62561 . As per IEC Standard.

29

-

-

... More
Supply, Installation, Testing & Commissioning of Clamps and Other Accessories to Hold Air Termination Rod . As per IEC Standard.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Tripods for Supporting Tubes with side outlet . As per IEC Standard.

13

-

-

... More
Supply, Installation, Testing & Commissioning of Sets of Threaded Rods for Tripod . As per IEC Standard.

13

-

-

... More
Supply, Installation, Testing & Commissioning of Plastic support plate for concrete base. For protecting the roofing sheets under the concrete base(17 kg.). The Diameter Ø outside 370 mm, Diameter Ø inside 360 mm and Material EVA. . As per IEC Standard.

40

-

-

... More
Supply, Installation, Testing & Commissioning of Concrete base for air-termination rods, for self-supporting air-termination rods in the tripod. Support Wedge- Ø16 mm, Diameter- Ø 337 mm, Material- concrete, Material of wedge- StSt & Weight 17kg. . As per IEC Standard.

119

-

-

... More
Supply, Installation, Testing & Commissioning of Parallel clamp to connect D 8mm L 700mm air termination rod, Material - StSt, clamping range Rd / Rd 7-10 mm . As per IEC Standard.

62

-

-

... More
Supply, Installation, Testing & Commissioning of Wall mounting bracket for fixing supporting tubes (D50 mm) to the structure to be protected or the wall. . As per IEC Standard.

29

-

-

... More
Supply, Installation, Testing & Commissioning of Parallel clamp to connect D 8mm L 2 m air termination rod, Material - StSt, clamping range Rd / Rd 7-10 mm . As per IEC Standard.

43

-

-

... More
Supply, Installation, Testing & Commissioning of Clamp to connect Air termination rod on Side Wall, Material - StSt, clamping range of air termination rod- Rd 10-16mm . As per IEC Standard.

14

-

-

... More
Supply, Installation, Testing & Commissioning of Anchor Fastener -2 , Size-M10x50mm, Material-SS . As per Standard.

29

-

-

... More
Supply, Installation, Testing & Commissioning of Nut Bolt - 2 , Size-M8x50mm, Material-SS . As per Standard.

29

-

-

... More
Supply, Installation, Testing & Commissioning of FS Clamps (Air-termination Rod Clamps 16mm) for connecting air-termination rods to roof . As per IEC Standard.

8

-

-

... More
Supply, Installation, Testing & Commissioning of Roof/Down Conductor & Conductor Holder . As per IEC Standard.

-

-

-

... More
Supply, Installation, Testing & Commissioning of High-voltage-resistant insulated down conductor for keeping the separation distance of ≤ 75 cm to electrically conductive parts according to IEC/EN 62305-3. Material of conductor Cu, Material of insulation PE, Cross section of core (solid / stranded) 19 mm², Equivalent separation distance s (in air) ≤ 75 cm, Diameter Ø conductor 20 mm. . As per IEC Standard.

248

-

-

... More
Supply, Installation, Testing & Commissioning of Conductor holder with plastic base for installation of HVI Conductor on wall, Material- StSt, Conductor holder support Rd- 20/23 mm. . As per IEC Standard.

126

-

-

... More
Supply, Installation, Testing & Commissioning of accessories Screw and Gitty, Material SS (M5 x 50mm) . As per IEC Standard.

910

-

-

... More
Supply, Installation, Testing & Commissioning of Upper and Lower termination Connection elements for sealing the HVI long Conductor on both ends, for implementing the sealing end of the conductor in the supporting tube. . As per IEC Standard.

23

-

-

... More
Supply, Installation, Testing & Commissioning of 8mm Al Roof Conductor. Diameter Ø conductor- 8 mm, Crosssection- 50 mm2, Material- AlMgSi, Standard EN 62561-2 . As per IEC Standard.

584

-

-

... More
Supply, Installation, Testing & Commissioning of Roof conductor holder FB2 for flat roofs with concrete block C35/45 with double conductor holder Rd 8 mm fixed, Dimension 141 x 86 x 70 mm . As per IEC Standard.

14

-

-

... More
Supply, Installation, Testing & Commissioning of Roof Conductor holder StSt for Rd 8-10 mm H 20 mm with female thread M8 preassembled with plastic base . As per IEC Standard.

570

-

-

... More
Supply, Installation, Testing & Commissioning of 8mm Al Down Conductor. Diameter Ø conductor- 8 mm, Crosssection- 50 mm2, Material- AlMgSi, Standard EN 62561-2 . As per IEC Standard.

199

-

-

... More
Supply, Installation, Testing & Commissioning of Down Conductor holder StSt for Rd 8-10 mm H 20 mm with female thread M8 preassembled with plastic base . As per IEC Standard.

199

-

-

... More
Supply, Installation, Testing & Commissioning of Universal Connector for interconnecting roof conductor & down conductor, Material of clamp StSt, clamping range Rd 8-10 mm . As per IEC Standard.

58

-

-

... More
Supply, Installation, Testing & Commissioning of Pipe clamp D 27-168 mm (3/4-6") StSt with terminal clamp 1xRd 10 mm or 2xRd 6-8 mm for connecting metal railing with 8mm Al solid round conductor, EN 50164-1 . As per IEC Standard.

7

-

-

... More
Supply, Installation, Testing & Commissioning of Lightning strike counter for digital recording of impulse currents. The device is preferably installed on the down conductors of the lightning protection system. Operating current (8/20 μs): 1 kA, Max. discharge current (10/350 μs): 100 kA, clamping range of rod: 8- 10mm, clamping range of flat: 30mm, Degree of protection: IP 65 . As per IEC Standard.

7

-

-

... More
Supply, Installation, Testing & Commissioning of Earthing System. As per IEC Standard.

-

-

-

... More
Supply, Installation, Testing & Commissioning of 4 sq.mm cable for equipotential of HVI cable . As per IEC Standard.

158

-

-

... More
Supply, Installation, Testing & Commissioning of Pipe clamp D 16-168 mm (3/4-6") StSt with terminal clamp 1xRd 10 mm or 2xRd 6-8 mm for connecting metal railing with 8mm Al solid round conductor, EN 50164-1 . As per IEC Standard.

14

-

-

... More
Supply, Installation, Testing & Commissioning of 4 sq.mm cable lug . As per Standard.

46

-

-

... More
Supply, Installation, Testing & Commissioning of Busbar with accessories . As per IEC Standard.

7

-

-

... More
Supply, Installation, Testing & Commissioning of UNI Disconnecting Clamps with intermediate plate as test link for round and flat conductor of Material- StSt, Material thickness- 2.5 mm, with clamping range- Rd / Fl 8-10 / 30 mm & Complied as per Standard EN 62561-1/EN 50164-1 . As per IEC Standard.

37

-

-

... More
Supply, Installation, Testing & Commissioning of GI flat (25x6mm) Strip having width- 25mm, thickness- 6mm, Material- Hot dipped Galvanized Iron, Cross Section- 150 mm2, Coating thickness- Avg. 70 microns. & Complied as per IEC 62561-2 for termination of down conductor from test link to the earth pit termination clamp and Interconnection of the earth pit to form type B earthing. . As per IEC Standard.

1830

-

-

... More
Supply, Installation, Testing & Commissioning of GI strip holder- Insulated holder, Material of construction - Dow moulded compound, height 19mm, Slot Size- 25x6 mm. . As per IEC Standard.

132

-

-

... More
Supply, Installation, Testing & Commissioning of Copper bonded rod with Low carbon steel, high tensile strength copper bonded rod with min 250 microns of copper plating, UL listed. Diameter- 17.2 mm, Length- 3 meters, Material- Copper Bonded, Coating thickness- 250 microns, min, Approvals- Tested acc. IEC / EN 62561-2, UL 467. . As per IEC Standard.

68

-

-

... More
Supply, Installation, Testing & Commissioning of 22.6kg backfilled compound, - Graphite based backfill compound having low resisitvity, does not decay or leachout, moisture retention capacity 10-15%, shall be tested for thermal stability for temp range -60 to +60 degree C, shall have sulphure content less than 0.04% shall have resistivity of 0.08 ohm or less, ROHS certified, to fill the bore area around the rod. . As per IEC Standard.

68

-

-

... More
Supply, Installation, Testing & Commissioning of SS 316 grade Termination clamp to terminate the load on earth electrode for termination, Material of construction - 316 grade stainless steel, Dimension - 160x35x3 mm . As per IEC Standard.

68

-

-

... More
Supply, Installation, Testing & Commissioning of Poly plastic pit cover of material- Polymer Body & Cover, Product Code- HEP, Dimensions- 308 mm (L) x 308 mm (W) X 214 mm (H), Weight 2.5 kg (5.50 LBS). . As per IEC Standard.

70

-

-

... More
Supply, Installation, Testing & Commissioning of Universal Connector for interconnecting roof conductor & down conductor, Material of clamp StSt, clamping range Rd 8-10 mm . As per IEC Standard.

62

-

-

... More
Supply, Installation, Testing & Commissioning of UNI disconnecting clamp with intermediate plate for round and flat conductor, Material StSt, clamping range Rd / Fl 8-10 / 30 mm, EN 50164-1 . As per IEC Standard.

31

-

-

... More
Supply, Installation, Testing & Commissioning of Internal Protection System (SPD’s) . As per IEC Standard.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Lightning current & Surge Protection Device at mains LT panel (3 phase, 415 V) for (L-N) Single-pole combined lightning current and surge arrester, Type 1 SPD. . As per IEC Standard.

170

-

-

... More
Supply, Installation, Testing & Commissioning of Lightning current & Surge Protection Device at mains LT panel (3 phase, 415 V) for (N-PE) Single-pole combined lightning current arrester, Type 1 SPD. . As per IEC Standard.

59

-

-

... More
Supply, Installation, Testing & Commissioning of Combined lightning current and surge arrester for use in single phase TT and TN system at mains LT panel (1 phase, 230 V), Type 1 + 2 SPD (If Breaker Rating 250 A) . As per IEC Standard.

17

-

-

... More
Supply, Installation, Testing & Commissioning of For 48 V DC Supply: Coordinated and modular single-pole spark-gap-based lightning current arrester for d.c. applications from 12 to 60 volts; with remote signalling contact for monitoring device (floating changeover contact). Type 1 SPD (If Breaker Rating 250 A) . As per IEC Standard.

28

-

-

... More
Supply, Installation, Testing & Commissioning of Arrester for CCTV, Data Networks and Ethernet Applications, Universal arrester for Industrial Ethernet, Power over Ethernet (IEEE 802.3 compliant up to PoE++ / 4PPoE) and similar applications in structured cabling systems according to class E up to 250 MHz. Protection of all pairs by powerful gas discharge tubes. DIN rail mounted adapter type with sockets, for protecting four pairs of data network interfaces via RJ45 sockets, for single-user application or application in 19 inch cabinets, space-saving. Max. continuous operating voltage (d.c.) (Uc ): 48V RJ 45 Connection or Ethernet Cable . As per IEC Standard.

186

-

-

... More
Supply, Installation, Testing & Commissioning of Modular and pluggable four-pole surge arrester with integrated Advanced Circuit Interruption (ACI) switch / spark gap for TT and TN-S systems (3+1 configuration); FM version with floating remote signaling contact, Type 2 SPD according to EN 61643-11 (no external backup fuse required) . As per IEC Standard.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Multi-purpose surge arrester consisting of a base element and a plug-in protection module, high discharge capacity due to heavy-duty zinc oxide varistor, high reliability due to "Thermo Dynamic Control" SPD monitoring device (for 24V DC and 48V DC) . As per IEC Standard.

18

-

-

... More
Supply, Installation, Testing & Commissioning of Universal single-pole surge arrester consisting of a base part and a plug-in protection module, Powerful d.c. switching device DCD, can be used without additional backup fuse. (for 220V DC) . As per IEC Standard.

19

-

-

... More
Supply, Installation, Testing & Commissioning of Modular combined lightning current and surge arrester for use in single phase TT system at mains LT panel (1 phase, 230 V) . As per IEC Standard.

24

-

-

... More
Supply, Installation, Testing & Commissioning of Modular Surge Arrester with integrated backup fuses for TT and TN-S system (3 phase, 415V) . As per IEC Standard.

4

-

-

... More
Supply, Installation, Testing & Commissioning of Serial Surge protector RS-232, underwriters laboratories (UL) listed. With DIN rail mounting kit, Operating temperature -10 to 70 degree C . As per IEC Standard.

14

-

-

... More
Supply, Installation, Testing & Commissioning of Serial Surge protector RS-485, underwriters laboratories (UL) listed. With DIN rail mounting kit, Operating temperature -10 to 70 degree C . As per IEC Standard.

14

-

-

... More
Supply, Installation, Testing & Commissioning of SPD FOR PLC SUPPLY . As per IEC Standard.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Space-saving combined lightning current and surge arrester module with Life Check feature for protecting four single lines sharing a common reference potential as well as unbalanced interfaces, for 24 V DC . As per IEC Standard. Along with Supply, Installation, Testing & Commissioning of Base part as a very space-saving and universal four pole feedthrough terminal for the insertion of a protection module without signal disconnection if the protection module is removed . As per IEC Standard.

17

-

-

... More
Supply, Installation, Testing & Commissioning of SPDs FOR FIELD DEVICES/EQUPMENTS (PRESSURE & TEMPERATURE TRANSMITTERS etc.) . As per IEC Standard.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Surge arrester with a low-capacitance protective circuit for protecting intrinsically safe measuring circuits and bus systems, meets FISCO requirements. Insulation strength 500 V to earth. (For Parallel Connection ½ NTP thread) For 24 V DC Supply (for PTs) . As per IEC Standard.

53

-

-

... More
Supply, Installation, Testing & Commissioning of Surge arrester with low-capacitance protective circuit for protecting intrinsically safe measuring circuits and bus systems, meets FISCO requirements. Insulation strength 500 V to earth. (For Series Connection ½ NTP thread) For 24 V DC Supply (for TTs) . As per IEC Standard.

24

-

-

... More
Supply, Installation, Testing & Commissioning of SPD’s FOR TELEPHONE LINE PROTECTION . As per IEC Standard.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Lightning current carrying DRL plug-in SPD block (10 pairs) for almost all applications. Expandable to a combined lightning current and surge arrester by means of a DRL protective plug. The integrated disconnection block contacts allow testing, measuring and patching with plugged-in protection.The three-pole gas discharge tubes have a fail-safe function with visual fault indicator. . As per IEC Standard. Along with Supply, Installation, Testing & Commissioning of Snap-on earthing frame for earthing and installation of max 10 DRL protection modules. Plugs into a 10-pair disconnection block or DRL plug- in SPD block. As per IEC Standard.

73

-

-

... More
Supply, Installation, Testing & Commissioning of Protective plug (one pair), energy-coordinated with DRL plug-in SPD block, for use as single-stage protective device for terminal equipment. Low voltage protection level line and integrated overcurrent protection for ADSL, ISDN Uk0 or a/b lines. To be mounted into EF 10 DRL. Installation recommended only in combination with DRL plug-in SPD block. As per IEC Standard.

732

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.