If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Food Corporation Of India - FCI Tender

Works
Electrical and Electronics
Eprocure
Opening Date22 Jan 2025
Closing Date1 Feb 2025
Tender Amount₹ 14,15,715 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Alternator: One number synchronous alternator rated at 40 kVA, 415 volts at 1500 rpm, 3 phase, 50 Hz. AC supply with 0.8 lagging power factor at 40ºC, 50% RH and at 1000 Metre MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited (AREP Based) and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class H insulation

-

-

-

... More
Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channeld with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(Price of foundation needs to be quoted seperately at sr. no. 07)

-

-

-

... More
Fuel tank:In built daily service fuel tank as pe manufactures specification complete with all stndard accessories and fuel piping between fuel tank and diesel engine, complete with valves, levelindicator and accessories as required as per specification attached.

-

-

-

... More
Exhaust system:Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor

-

-

-

... More
Starting System:12V/24V DC starting system comprising of starter motor, voltage regulator and arrangement for initial excitation, complete with required nos of suitable batteries as required and as per specification.

-

-

-

... More
Acoustic Enclosure:Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air in to the atmosphere as per specification attached.

-

-

-

... More
Remote monitoring system : The DG set should have provision of remote monitoring system available from the make same as Alternator,AMF,Engine which share real time genset information and location service which can be accessed via Mobile or Desktop

-

-

-

... More
AMF Panel: Supplying, installation, testing and commissioning of automatic mains failure control including auto By pass panel of 16 SWG CRCA sheet with suitable rating of copper/ aluminium bus bar as approved by Engineer in Charge, suitable for 40 KVA silent type DG site complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF Panel to diesel Engine and else where if required all complete and inter locking including the following

1

-

-

... More
80 Amps. (minimum) Four pole MCCB, with rotary operating mechanism with phase barriers - 2 nos. (For mains and alternator) or as per manufacturers requirement or as per directions of engineer-in-charge.

-

-

-

... More
100 Amps (minimum) , FP power contactor - 2 sets (For mains and alternator) with interlocking arrangement or as per manufacturers requirement or as per directions of engineer-in-charge.

-

-

-

... More
Micro processor based automatic mains failure function unit for emergency and stand by power supply system having under voltage, over voltage and single phasing protection and other standard features - 1 no.

-

-

-

... More
Micro processor based IDMT relay for three phase over current + earth fault - 1 set.

-

-

-

... More
Energy analyser unit to indicate, current, voltage, frequency, power factor and kWh

-

-

-

... More
Phase indication lamps for DISCOM and Generator - 1 Set

-

-

-

... More
Emergency trip switch, Auto/Manual/Off selector switch, trickle/boost charger switch and SMPS battery charger unit complete with transformer, rectifier, DC Voltmeter and ammeter, off and boost and current adjustment etc. - 1 Set

-

-

-

... More
Bakelite HRC fuses/ MCB and control wiring for the entire system - 1 Set

-

-

-

... More
Indicating lamps for load on mains and load on set - 1 Set

-

-

-

... More
Fuse for instruments - 1 Set

-

-

-

... More
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.

4

-

-

... More
Supplying and laying 25 mm X 5 mm G.l strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm)

40

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

12

-

-

... More
Providing foundation and platform for the Rated capacity Silent type DG set (As per item No.1 ) so as to place the DG Set conforming to specifcation including earth work, exacavation, ramming, providing foundation for plinth with mix of 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size derived from natural sources), including centring & shuttering, brick work with common burnt clay FPS (non modular) bricks with Cement mortar , Steel reinforcement for R.C.C. work,foundation work, cement plaster work, as per attached drawing and as per directions of engineer-in-charge.

1

-

-

... More
Providing and fixing precoated galvanised iron profile sheets of total thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with zinc coating complete upto any pitch in horizontal/ vertical or curved surfaces with Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. with mild steel round holding down bolts with nuts and washer plates complete as per requirement for the Rated capacity Silent type DG set (As per item No.1 ) as per direction of engineer-in-charge.

1

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

11.25

-

-

... More
Supplying of XLPE Armoured cable with aluminium conductor of 1.1 KV grade conforming to IS:7098 (Part- I) 1988 with up to date ammendments of the following size as required. 3.5 x 70 sq. mm

27

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm

17

-

-

... More
Laying of one no. PVC insulated, PVC Sheathed XLPE/ power cable of 1.1 KV grade on wall Surface etc. as reqd. (clamped with 25/40X3mm MS flat clamp) Above 35 sq.mm and upto 95 sq.mm

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38m)

4

-

-

... More
Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.