Firozabad Shikohabad Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Firozabad Shikohabad Development Authority Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date26 Oct 2024
Closing Date11 Nov 2024
Tender Amount₹ 1,38,17,199 
Notes
Download

Costs

Summary

Supply And Fixing Of Street Lights With Tiranga Led On Pengu-sirsaganj Road Firozabad

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(B) 70 sqmm 3.5 CORE

150

870

130500

... More
Supply and Laying of 63 mm dia (OD- 63 MM & ID - 51 mm Nominal ) size DWC HDPE Pipe ISI Marked along with all accessories like socket , bend , couplers etc conforming to IS 14930 , Part II Complete with fitting and Cutting , Jointing etc direct in ground (75 cm below ground Level ) including Excavatin and refilling the trench but Excluding sand cushioning and protective covering etc complete as required .

3500

247

864500

... More
Supply and burrying of 75 mm Dia 3 Mtrs. Long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/Mtr) in the ratio of 3:1:1 (marconite : cement : water) on M.S. Rod wiih hole (16 mm diameter X3 Mtrs ) will be vertically installed for earthing with 1 Mtr G.I strip (25 mm X 2.5mm) connected with SS nut bolt. The earth electrode will be installed into the 100 mm pit up to 3000 mm depth. noraml soil will be used as backfill material. Make : As approved in U.P.P.W.D & C.P.R.I. Certified.

115

19700

2265500

... More
Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only . Incoming 100 Amp MCCB -1 No & Outgoning 63 Amp. MCCB-2 No & Cat. B. Pannel Cubicle Type.UP PWD SOR No. - 811-C-ii SOR -20.1.1a -ii

4

107768

431072

... More
Supply & Fixing of CCMS Panel with Software complete as per Direction of Engineer in Charge .

6

155000

930000

... More
Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge A. 35 sq.mm

664

31

20584

... More
B- 70 sq.mm

24

67

1608

... More
S/F of 6 Amp to 32 AMP DP MCB for Controlling of Street Light , including Cost of Din Mounting Rail , Connecting Strip , Earth Link etc Complete in all Respect

115

1150

132250

... More
Making Connection of Each Street Light by S/L 1.5 Sqmm FRLSH Copper wire from Pole Busbar Box to street Light Fitting Complete as per Direction of Engineer In Charge

115

615

70725

... More
Supply & Fixing of Radium Strip Green , Red and Yellow complete in all respect

115

300

34500

... More
Numbering of pole as per Direction of Engineer in Charge

115

200

23000

... More
Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect.

515

1110

571650

... More
Supply & Fixing of Tiranga Waterproof Light SMD 2835 120 LED 220 V Single Chip Strips Driver : Apra (30 M Per Pole x 160 No of Poles ) as approved by Engineer in Charge .

3450

219

755550



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.